THEPRODUCTSDESCRIBEDHEREINARESUBJECT
TOTHEJABSCOONEYEARLIMITEDWARRANTY,WHICH
ISAVAILABLEFORYOURINSPECTIONUPONREQUEST.
SERVICE AND MAINTENANCE
UseonlygenuineJabscoreplacementparts.Insurepoweris
removed from pump before service. Drain supply tank and/
or pump system dry before disconnecting liquid fittings.
Periodically clean PUMPGUARD strainers. Keep spare part
kits on hand. Adhere to a preventive maintenance schedule
andreplace‘ware’partsbeforetheendoftheirservicelife.
DISSASSEMBLY
Refertoexplodedview.
PRESSURE SENSOR OR PRESSURE SWITCH Remove
coverinitem1.OnVSDmodels,removeclipandunplugpres-
suresensor.Ondemandmodels,disconnectwireleadsfrom
terminals. Remove two mounting screws to release sensor/
switchhousinganddiaphragminfigure1.
UPPER HOUSINGRemovefourpumpheadscrewstorelease
upperhousing,item1.Inspectbackflowvalveinsensorport
for debris. Clean if necessary. Install new sealing ferrules in
upperhousingbeforere-assembly.
CHECK VALVE ASSEMBLYRemoveo-ringandcheckvalve
assemblyitem2frompumphead.Valvesshouldbecleanand
resilient.Replaceifnecessary.Alwaysreplaceo-ringseal.
LOWER HOUSING ASSEMBLYRemovesetscrewitem4in
cam bearingassembly frommotor shaft usingan 1/8” Allen
wrench.Toaccesssetscrew,removerubberplugfromaccess
hole inlower housing and rotate the lower housing until the
access hole and set screw are inalignment. Always replace
complete lower housing assemblyincluding diaphragm, pis-
tons,andcambearingassembly.
RE-ASSEMBLY Re-assemble in reverse order. Rotate each
screwcounterclockwiseandthenclockwiseduringassembly
toinsurethatself-tappingscrewsengageintooriginalthreads.
Note: cutting new threads will diminish the strength of the
threadengagement.Insurethesetscrewinitem3isaligned
withindentationonmotorshaft.Tightensetscrewto35in-lbs
of torque. Tightenfour piston screwsto 18in-lbs of torque.
Tightenfourpumpheadscrewsto30in-lbsoftorque.Sensor/
switch screws should be hand tight. Do not over tighten.
TROUBLESHOOTING CHART
PROBLEM/CAUSE SOLUTION
FAILURETOPRIMEORPUMP
•Debrisincheckvalveassembly Cleancheckvalveassembly
•Airleakinsuctionline Tightenallfittingsandclamps
•Restrictedsuctionline Cleanstrainerorremovekinkinsuctiontube
•Supplytankisempty Fillsupplytank
•Ruptureddiaphragm Replacelowerhousingassembly
MOTORFAILSTORUN
•Pumpcircuithasnopower Checkmainswitch,wire,fuseorbreaker
•Looseorcorrodedwireconnection Fixorreplacewireconnections
•Blownfuseoropencircuitbreaker Determinecause,resetbreakerorreplacefuse
•Openthermalprotectorinmotor Turnpowerswitchoff,allowmotortocool
•Defectivemotor,drive,orsensor Replacedefectivecomponent
PUMPFAILSTOTURNOFF
•Supplytankisempty Fillsupplytank
•Debrisincheckvalveassembly Cleanorreplacecheckvalveassembly
•Nobatteryincircuit Installbattery,replaceVSDmotor
•Leakingdischargeline Tightenorreplaceleakingfittingorpipe
•Leakingdiaphragmorpumphead Replacelowerhousingassembly
LOWFLOWORPRESSURE
•Blockedinletstrainer Cleanstrainer
•Blockedwaterfilter Replacefilterelement
•Undersizedplumbingorverylongruns Increaseplumbingto3/4”insidediameter
•Defectivemotor,drive,orsensor Replacedefectivecomponent
Jabsco is a trademark of Xylem Inc. or one of its subsidiaries.
© 2012 Xylem, Inc. 43000-0869 Rev C 6/12
www.xylemflowcontrol.com
Jabsco, 1 Kondelin Road, Cape Ann Industrial Park, Gloucester, MA 01930
Tel: +1 978 281 0440 Fax: +1 978 283 2619
Jabsco, Bingley Road, Hoddesdon, Hertfordshire, EN11 0BU
Tel: +44 (0) 1992 450 145 Fax: +44 (0) 1992 467 132
NHK Jabsco Co Ltd, 3-21-10, Shin - Yokohama Kohoku-ku, Yokohama 222
Tel: +81 (0) 45 475 8906 Fax: +81 (0) 45 475 8908
Jabsco GmbH, Oststraße 28, 22844 Norderstedt
Tel: +49 (0) 40 53 53 73 0 Fax: +49 (0) 49 53 53 73 11
Jabsco Italia, s.r.l., Via Tommaseo, 6, 20059 Vimercate, Milano
Tel: +39 039 685 2323 Fax: +39 039 666 307
USA
UK
JAPAN
GERMANY
ITALY