MARK-10 ESM301(L)-001 travel indication retrofit User guide

Type
User guide

MARK-10 ESM301(L)-001 travel indication retrofit provides precise linear travel measurement capabilities to your existing test stand, allowing for accurate displacement monitoring during force testing applications. With its easy installation process, this retrofit option seamlessly integrates with your test stand, enhancing its functionality and versatility. The linear encoder technology ensures high-resolution measurement, enabling detailed and reliable data acquisition.

MARK-10 ESM301(L)-001 travel indication retrofit provides precise linear travel measurement capabilities to your existing test stand, allowing for accurate displacement monitoring during force testing applications. With its easy installation process, this retrofit option seamlessly integrates with your test stand, enhancing its functionality and versatility. The linear encoder technology ensures high-resolution measurement, enabling detailed and reliable data acquisition.

Mark-10 Corporation
11 Dixon Avenue, Copiague, NY 11726 USA
Tel: +1 631 842 9200
Fax: +1 631 842 9201
www.mark-10.com
We make a measurable difference in force and torque measurement
ESM301(L)-001 TRAVEL INDICATION OPTION
RETROFIT INSTALLATION INSTRUCTIONS
1. Loosen and remove the limit switch positioning screws, as shown below:
2.
Remove both sheet metal covers from the test stand by loosening the four screws on
each side, as shown below:
Mark-10 Corporation
11 Dixon Avenue, Copiague, NY 11726 USA
Tel: +1 631 842 9200
Fax: +1 631 842 9201
www.mark-10.com
We make a measurable difference in force and torque measurement
3. Remove the left side support plate by loosening the four Allen screws, as shown below:
4. Remove the limit switch support plate by loosening the four Allen screws, as shown
below:
Mark-10 Corporation
11 Dixon Avenue, Copiague, NY 11726 USA
Tel: +1 631 842 9200
Fax: +1 631 842 9201
www.mark-10.com
We make a measurable difference in force and torque measurement
5. Move the crosshead down to its lowest position on the test stand.
6. Position the test stand on its right side.
Mark-10 Corporation
11 Dixon Avenue, Copiague, NY 11726 USA
Tel: +1 631 842 9200
Fax: +1 631 842 9201
www.mark-10.com
We make a measurable difference in force and torque measurement
7. Note the three holes that are to be utilized for attaching the linear encoder.
8. Position the linear encoder on the linear displacement strip, at the end of the support
plate, as shown below:
Linear encoder
Displacement strip
Support plate
Mark-10 Corporation
11 Dixon Avenue, Copiague, NY 11726 USA
Tel: +1 631 842 9200
Fax: +1 631 842 9201
www.mark-10.com
We make a measurable difference in force and torque measurement
9. Place the linear travel displacement support plate onto the test stand, as shown in the
following images:
Mark-10 Corporation
11 Dixon Avenue, Copiague, NY 11726 USA
Tel: +1 631 842 9200
Fax: +1 631 842 9201
www.mark-10.com
We make a measurable difference in force and torque measurement
10. Install the linear travel displacement support plate with four Allen screws, as shown
below:
11. Install the encoder with the three supplied screws (two flat screws, one Phillips screw),
through the clearance holes in the support plate, as shown below:
Mark-10 Corporation
11 Dixon Avenue, Copiague, NY 11726 USA
Tel: +1 631 842 9200
Fax: +1 631 842 9201
www.mark-10.com
We make a measurable difference in force and torque measurement
12. Place the test stand upright and position the crosshead approximately 3 - 5 inches
(75 – 125 mm) above the base, as shown below:
3 – 5 inches
(75 – 125 mm)
13. Before re-installing the limit switch support plate, be sure to position the limit switches at
their furthest allowable extremes, as shown below:
Mark-10 Corporation
11 Dixon Avenue, Copiague, NY 11726 USA
Tel: +1 631 842 9200
Fax: +1 631 842 9201
www.mark-10.com
We make a measurable difference in force and torque measurement
14. Re-install the limit switch support plate.
15. Re-install the sheet metal covers.
Mark-10 Corporation
11 Dixon Avenue, Copiague, NY 11726 USA
Tel: +1 631 842 9200
Fax: +1 631 842 9201
www.mark-10.com
We make a measurable difference in force and torque measurement
16. Re-install the limit switch positioning screws.
17. Connect the coiled encoder cable between the mini-USB connector adjacent to the
linear encoder and the appropriate port in the rear of the test stand controller, as shown
below. ESM301(L)-001 installation is now complete.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

MARK-10 ESM301(L)-001 travel indication retrofit User guide

Type
User guide

MARK-10 ESM301(L)-001 travel indication retrofit provides precise linear travel measurement capabilities to your existing test stand, allowing for accurate displacement monitoring during force testing applications. With its easy installation process, this retrofit option seamlessly integrates with your test stand, enhancing its functionality and versatility. The linear encoder technology ensures high-resolution measurement, enabling detailed and reliable data acquisition.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI