Taylor Technologies K-8027AB Owner's manual

Type
Owner's manual

Taylor Technologies K-8027AB is a pH 6.5-8.5 (with Acid & Base Demand) reagent pack, formulated for exclusive use with Taylor's TTi® Colorimeter. It allows for precise pH measurement and adjustment in various water types, including potable water, recreational water, and wastewater. The pack includes three reagents (A, B, C) for testing pH and determining acid or base demand, enabling users to make informed decisions about pH adjustment. The estimated detection limit is 6.50 pH units, providing accurate readings within a specific range.

Taylor Technologies K-8027AB is a pH 6.5-8.5 (with Acid & Base Demand) reagent pack, formulated for exclusive use with Taylor's TTi® Colorimeter. It allows for precise pH measurement and adjustment in various water types, including potable water, recreational water, and wastewater. The pack includes three reagents (A, B, C) for testing pH and determining acid or base demand, enabling users to make informed decisions about pH adjustment. The estimated detection limit is 6.50 pH units, providing accurate readings within a specific range.

pH 6.5-8.5 (with Acid & Base Demand)
Range(s): 6.50-8.50
Colorimeter Series
Instruction #5859
Procedure
Note: When testing multiple samples simultaneously, a
separate sample cell with an unreacted sample of the
water tested must be used to zero the colorimeter.
Please note that varying the test procedure from the
original can affect the precision of the test.
1. Turn on the Colorimeter.
2. Select a test menu (ALL TESTS, RECENT TESTS, or
FAVORITES) containing pH 6.5-8.5 using .
3. Select pH 6.5-8.5 using  ; then press ENTER .
4. Rinseandll25mmsamplecellto10mLmarkwith
sample; then cap.
5. Insert sample cell into sample cell compartment. Align
marksperUsersManual.
6. Select ZERO using ; then press ENTER . Zero
will be displayed.
7. Remove sample cell from sample cell compartment;
then remove cap.
8. Add0.5mLpH6.5-8.5-ReagentA;thencapandswirl
to mix thoroughly.
9. Insert sample cell into sample cell compartment. Align
marks.
10. SelectREADusing; then press ENTER . The
instrument will read the sample and the result will be
displayed.
11. ToLOWERpHseeAcidDemandTest.ToRAISEpH
seeBaseDemandTest.
AcidDemandTest
1. UsetreatedsamplefrompHTest.
2. Add 1 drop pH 6.5-8.5 - Reagent B to sample cell.
Cap and swirl to mix.
3. Insert sample cell into sample cell compartment. Align
marks.
4. Press ENTER . The result will be displayed.
5. Continue adding Reagent B dropwise until desired pH
is reached.
6. Record number of drops dispensed and refer to Acid
DemandTreatmentTableforcorrectamountofmuri-
atic acid to add to lower pH.
BaseDemandTest
1. UsetreatedsamplefrompHTest.
2. Add 1 drop pH 6.5-8.5 - Reagent C to sample cell.
Cap and swirl to mix.
3. Insert sample cell into sample cell compartment. Align
marks.
4. Press ENTER . The result will be displayed.
5. Continue adding Reagent C dropwise until desired pH
is reached.
6. Record number of drops dispensed and refer to Base
DemandTreatmentTableforcorrectamountofsoda
ash to add to raise pH.
(over)
Instruction #5859
Treatment
Tables
ACID DEMAND TREATMENT TABLE
ToDecreasepHUsingMuriaticAcid(20°Baumé/31.45%HCl)
Volume of Water - U.S. Gallons/Liters
DropsofpH6.5-8.5-
Reagent B
400gallons/
2,000liters
1,000gallons/
4,000liters
5,000gallons/
20,000liters
10,000gallons/
40,000liters
20,000gallons/
80,000liters
50,000gallons/
100,000liters
100,000gallons/
400,000liters
1 drop
0.37oz/
14.3 mL
0.92oz/
28.6 mL
4.58oz/
143 mL
9.16oz/
286 mL
1.15pt/
573 mL
1.43qt/
716 mL
2.86qt/
2.86 L
2 drops
0.73oz/
28.6 mL
1.83oz/
57.3 mL
9.16oz/
286 mL
1.15pt/
573 mL
1.15qt/
1.15 L
2.86qt/
1.43 L
1.43gal/
5.74 L
3 drops
1.10oz/
43.0mL
2.75oz/
85.9 mL
13.7oz/
430mL
1.72pt/
859 mL
1.72qt/
1.72 L
1.07gal/
215 L
2.15gal/
8.59 L
4 drops
1.47oz/
57.3 mL
3.67oz/
115 mL
1.15pt/
573 mL
1.15qt/
1.15 L
2.29qt/
2.29 L
1.43gal/
2.86 L
2.86gal/
11.5 L
5 drops
1.83oz/
71.6 mL
4.58oz/
143 mL
1.43pt/
716 mL
1.43qt/
1.43 L
2.86qt/
2.86 L
1.79gal/
3.58 L
3.58gal/
14.3 L
6 drops
2.20oz/
85.9 mL
5.50oz/
172 mL
1.72pt/
859 mL
1.72qt/
1.72 L
3.44qt/
3.44 L
2.15gal/
4.30L
4.30gal/
17.2 L
7 drops
2.57oz/
100mL
6.41oz/
200mL
1.00qt/
1.00L
2.00qt/
2.00L
1.00gal/
4.01L
2.51gal/
5.01L
5.01gal/
20.0L
8 drops
2.93oz/
115 mL
7.33oz/
229 mL
1.15qt/
1.15 L
2.29qt/
2.29 L
1.15gal/
4.58 L
2.86gal/
5.73 L
5.73gal/
22.9 L
9 drops
3.30oz/
129 mL
8.25oz/
258 mL
1.29qt/
1.29 L
2.58qt/
2.58 L
1.29gal/
5.15 L
3.22gal/
6.44 L
6.44gal/
25.8 L
10drops
3.67oz/
143 mL
9.16oz/
286 mL
1.43qt/
1.43 L
2.86qt/
2.86 L
1.43gal/
5.73 L
3.58gal/
7.16 L
7.16gal/
28.6 L
(next page)
Instruction #5859
Treatment
Tables
BASE DEMAND TREATMENT TABLE
ToIncreasepHUsingSodaAsh(SodiumCarbonate,100%)
Volume of Water - U.S. Gallons/Liters
DropsofpH6.5-8.5-
Reagent C
400gallons/
2,000liters
1,000gallons/
4,000liters
5,000gallons/
20,000liters
10,000gallons/
40,000liters
20,000gallons/
80,000liters
50,000gallons/
100,000liters
100,000gallons/
400,000liters
1 drop
0.21oz/
7.68 g
0.51oz/
15.4 g
2.56oz/
76.8 g
5.13oz/
154 g
10.3oz/
307g
1.60lb/
384 g
3.20lb/
1.54kg
2 drops
0.41oz/
15.4 g
1.03oz/
30.7g
5.13oz/
154 g
10.3oz/
307g
1.28lb/
614 g
3.20lb/
768 g
6.41lb/
3.07kg
3 drops
0.62oz/
23.0g
1.54oz/
46.1 g
7.69oz/
230g
15.4oz/
461 g
1.92lb/
922 g
4.81lb/
1.15kg
9.61lb/
4.61kg
4 drops
0.82oz/
30.7g
2.05oz/
61.4 g
10.3oz/
307g
1.28lb/
614 g
2.50lb/
1.23kg
6.41lb/
1.54kg
12.8lb/
6.14kg
5 drops
1.03oz/
38.4 g
2.56oz/
76.8 g
12.8oz/
384 g
1.60lb/
768 g
3.20lb/
1.54kg
8.01lb/
1.92kg
16.0lb/
7.68kg
6 drops
1.23oz/
46.1 g
3.08oz/
92.2 g
15.4oz/
461 g
1.92lb/
922 g
3.85lb/
1.84kg
9.61lb/
2.30kg
19.2lb/
9.22kg
7 drops
1.44oz/
53.8 g
3.59oz/
108g
1.12lb/
538 g
2.24lb/
1.08kg
4.49lb/
2.15kg
11.2lb/
2.69kg
22.4lb/
10.8kg
8 drops
1.64oz/
61.4 g
4.10oz/
123 g
1.28lb/
614 g
2.56lb/
1.23kg
5.13lb/
2.46kg
12.8lb/
3.07kg
25.6lb/
12.3kg
9 drops
1.85oz/
69.1 g
4.61oz/
138 g
1.44lb/
691 g
2.88lb/
1.38kg
5.77lb/
2.76kg
14.4lb/
3.46kg
28.8lb/
13.8kg
10drops
2.05oz/
76.8 g
5.13oz/
154 g
1.60lb/
768 g
3.20lb/
1.54kg
6.40lb/
3.07kg
16.0lb/
3.84kg
32.0lb/
15.4kg
(over)
Ordering Info
Reagent Pack
K-8027AB pH6.5-8.5(withAcid&BaseDemand)
FormulatedforexclusiveusewithTaylorsTTi
®
Colorimeter.
Reagent Pack Components
R-8027A pH6.5-8.5-ReagentA
R-8027B pH6.5-8.5-ReagentB
R-8027C pH6.5-8.5-ReagentC
Instruction #5859
Application
Potable Water, Recreational Water, and Wastewater
Test Method
Phenol Red
Phenolredhasaworkingrangeofapproximately6.50–8.50.Awatersampleatthelowendwillturnyellowwhentreatedwithphenolred.Thecolorwillgraduallytransitiontoadark
reddish-purpleasthesample’spHincreasesto8.50.
6.50pHunits
Estimated
Detection Limit
Precision
UsingasinglelotofreagentandastandardsolutionofpH7.50,anindividualanalystobtainedastandarddeviationwiththeinstrumentof±0.10pHunits.
Interferences
Alkalinity,Total(CaCO
3
)<60ppm–negativeinterference
Alkalinity,Total(CaCO
3
)>180ppm–positiveinterference
The following analytes were tested to the levels listed and
foundnottocauseanyinterferenceuptothespeciedvalues:
Biguanide(asproduct)–50ppm
Bromine–10ppm
Chlorine–10ppm
Copper–0.5ppm
CyanuricAcid–200ppm
Hardness, Calcium (CaCO
3
)–1000ppm
09/16
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548)•410-472-4340
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Taylor Technologies K-8027AB Owner's manual

Type
Owner's manual

Taylor Technologies K-8027AB is a pH 6.5-8.5 (with Acid & Base Demand) reagent pack, formulated for exclusive use with Taylor's TTi® Colorimeter. It allows for precise pH measurement and adjustment in various water types, including potable water, recreational water, and wastewater. The pack includes three reagents (A, B, C) for testing pH and determining acid or base demand, enabling users to make informed decisions about pH adjustment. The estimated detection limit is 6.50 pH units, providing accurate readings within a specific range.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI