Safety 7 MAXXfl o EVO
2.2.4 HEATER INSTALLATION AND MAINTENANCE
This heater has been designed for use with G20 (natural gas) and G31 (liquefi ed propane gas) and
is manufactured to give an effi cient, safe and long service life. To ensure continued trouble-free op-
eration of this heater at maximum effi ciency, it is essential that correct installation, commissioning,
operation and service procedures are carried out strictly in accordance with the instructions given
in this manual.
Only original parts and accessories from the manufacturer may be used on this heater. Using non-
approved parts may compromise the safety of the heater and invalidate any warranty.
In the event of failure and/or suspected faulty functioning of the heater. Switch off the heater and
contact a suitable qualifi ed technician. Do not attempt to make any repairs yourself, unless you are
suitably qualifi ed and competent to do so.
2.3 REGULATIONS AND STANDARDS
This heater must be installed in accordance with relevant Standard Specifi cations, Codes of Practice and cur-
rent Building Regulations, together with any special regional requirements of the Local Authorities, Gas under-
taking and Insurance Regulations for the Electrical Equipment of Buildings. The installation of this heater must
be in accordance with the relevant requirements of:
• Health and safety at work act 1974
• Building regulations 2010
• Electricity at work regulations 1989
• Management of health and safety at work regulations 1998
• Manual handling regulations 1992
• Model water byelaws 1986
• BS 7671 - Requirements for electrical installations, IEE wiring, regulations
• BS 6644 - Specifi cation for the installation of Gas fi red hot water boilers for rated inputs between 70kW
(net) and 1.8 MW
• BS 7074-2 - Applications selection and Installation of expansion vessels and ancillary equipment for sealed
water systems.
• BS 6880:1 Code of practice for low temperature hot water heating systems of output greater than 45kW.
• BS 6880:2 Code of practice for low temperature hot water heating systems of output greater than 45kW.
• BS 6880:3 Code of practice for low temperature hot water heating systems of output greater than 45kW.
• CP 342:2 Code of practice for centralised hot water supply. Buildings other than individual dwellings.
• IM/11 - Flues for commercial and Industrial Gas Fired Boilers and Air Heaters
• IGE/UP/1 - Soundness Testing and Purging Procedure for Non Domestic Installations
• IGE/UP/2 - Gas Installation Pipe work, Boosters and Compressors for Industrial and Commercial Premises
• IGE/UP/10 - Installation of fl ued gas appliances in industrial and commercial premises.
• IGE/UP/16 - Design for Natural Gas installations on industrial and commercial premises with respect to
hazardous area classifi cation and preparation of risk assessments
These manufacturer’s notes must not be taken in any way as over-riding statutory
obligations.