Marco Ecoboiler PB5 Installation guide

Type
Installation guide

This manual is also suitable for

INSTRUCTIONS FOR MODELS
ECOBOILER T2
(P/N: 1000672 and 1000672#)
ECOBOILER T5
(P/N: 1000660 and 1000660#)
ECOBOILER T10
(P/N: 1000661 and 1000661#)
ECOBOILER PB5
(P/N: 1000665 and 1000665#)
ECOBOILER PB10
(P/N: 1000666 and 1000666#)
(Where # is a suffix of one or more letters except US models )
Page 2. Instruction for use in English
Page 5. Instruction for use in French
Page 9. Instruction for use in German
Page 13. Instruction for use in Russian
Permissible mains inlet water pressure:
Minimum 100kPa / 0.1MPa / 1bar / 14.5psi
Maximum 1000kPa / 1MPa / 10bar / 145psi
Marco Beverage Systems Limited.
63d Heather Road,
Sandyford Industrial Estate,
Dublin 18.
Marco Beverage Systems Limited.
Shire House, Strixton Manor,
Strixton, Wellingborough, Northants,
NN29 7PA
Ireland Tel: 00353 (0) 1 295 2674
Ireland Fax: 00353 (0) 1 295 3715
UK Tel: 0044 (0) 1933 666 488
UK Fax: 0044 (0) 1933 666 968
www.marcobeveragesystems.com email: [email protected]
SAFETY:
This appliance must be earthed. If the moulded plug supplied is not used then ensure that
the green/yellow cable is connected to a suitable earth.
Risk of flooding. The hose supplied with this unit is non-toxic food quality tested to 190psi.
However, a hose is not a permanent connection. It is, therefore, advisable to switch off
boiler and close the stopcock valve when boiler is not in use, e.g. overnight, weekends etc.
Risk of scalding. Beware of accidentally operating the water draw off tap or push button
especially when cleaning the front of the boiler.
The utmost care has been taken in the manufacture and testing of this unit. Failure to
install, maintain and / or operate this boiler according to the manufacturer’s instructions
may result in conditions that can cause injury or damage to property. If in any doubt about
the serviceability of the boiler always contact the manufacturer or your own supplier for
advice.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
In the event any wires are damaged, such wires can only be replaced by experts or
professional after service staff from the manufacturer, after service department or similar
function departments.
INSTALLATION DETAILS:
General installation:
To be installed in locations where temperatures are between 5°C and 35°
Ensure that the appliance is placed on a flat horizontal surface.
Ensure that the appliance is installed where it can be observed by trained
personnel.
Electrical installation:
Electrical specification: 2.8kW 200-230Vac 50Hz
A moulded 13A plug is factory fitted. A suitable 13A outlet is all that is required.
For 200V installation ensure appropriate connection to suitable supply.
Plumbing installation procedure:
Mains water pressure required (limits): 14.5-145psi (100-1000kPa)
Fit a stop Valve on a cold-water line and attach a 3/4" BSP male fitting,
(e.g. 3/4" x 1/2" 311 or washing machine type stop valve).
Where a flexible hose is to be used in the installation please use the new hose set supplied.
Do not use old flexible hose sets for the instillation of this appliance.
Connect straight tailpiece of the hose to the stop valve fitting. Make sure that the pre-attached
sealing washer is fitted.
Turn on the water to flush any impurities, dust etc from the inlet hose and water pipe. Allow
several gallons through.
Connect right-angled tailpiece of the hose to the inlet valve of the boiler (again 3/4" BSP).
Make sure the sealing washer is fitted here also.
Turn on water and check for leaks.
NOTE: Using a non-food grade hose (e.g. a washing machine hose) will usually result in off
tastes & smells in the water and can possibly be toxic.
Operating boiler for the first time:
Check that all installation procedures have been carried out.
Ensure water valve is on.
Plug boiler into 13A socket and press power button on the front of the machine marked
‘Power’. Refer to Figure 1.
NOTE: On a 2L or 5L machine the ‘Power’ button light also acts as the “Ready/Status” indicator.
The “power on” light will glow green and the machine will fill to a safe level, above the
elements, before heating.
The “Ready/Status” light will cycle two red flashes while the machine is filling to the safe level.
After this amount of water has heated to about 96ºC the boiler will draw more water in until the
temperature drops by 1 or 2 degrees. The boiler will then heat again. This heat fill cycle
continues until the boiler is full.
On a 2L or 5L machine, whilst the machine is above the safe level and filling, the
“Ready/Status” light will glow orange.
On a 10L machine, whilst the machine is above the safe level and filling, the “Ready/Status”
light will remain blank.
The “Ready/Status” light will glow green when the machine is both full and up to normal
operating temperature. For 2L allow approx. 10minutes. for 5L allow approx. 15 minutes and
for 10L machines allow approx 30 minutes.
The boiler is now ready for use.
2L & 5L Display 10L Display
Figure 1: Machine User Interface
NOTE: Because the boiler is electronically controlled no priming is necessary.
The element cannot switch on until a safe level of water is reached.
ECO Mode Operation:
All ECO Boilers use high grade insulation and it is applied to give a significant energy usage
improvement over a standard water boiler.
The 10L ECO Boiler variants also incorporate a ½ tank ‘ECO mode’ function.
To enable the ‘ECO Mode’ press the button located below the ‘Ready’ indicator so that the leaf
symbol illuminates green.
This mode saves energy by minimising the energy wasted during machine down-time.
NOTE: The ECO mode is most effective in installations where the machine has a regular ‘off’
period.
To achieve the most benefit from the energy saving ‘ECO Mode’ on your ECO boiler unit (10L
variants only), the following method should be employed:
o Towards the end of the boilers operating period for a given day, switch the machine to
ECO Mode. Whilst maintaining water at 96
o
C, the machine tank will slowly drop to half
full, where it will remain.
o At the end of the machines operating period it should be turned ‘off’.
o During the ‘off’ period as there is less water in the tank there will be less energy lost to
the surrounding environment resulting in an energy saving.
To disable simply press the ‘ECO Mode’ button again so that the leaf symbol is not illuminated.
Power
Button
Ready/Status
Indicator
Ecomode
Button
TROUBLESHOOTING:
The Ready/Status light signals various errors or problems. A cycle of red flashes indicates an error.
The number of flashes in a cycle corresponds to the symptom in the table below:
Status/Diagnostic light guide:
Symptom
Action required
Water level below elements. Normal
when machine first fills.
Check water pressure , if this is OK then call
service agent.
Temperature sensor failure (o/c)
Call service agent
Water not heating
Call service agent
Temperature sensor failure (s/c)
Call service agent
Machine not filling
Check water pressure, if OK then call service
agent.
MAINTENANCE:
This machine has been designed to give many years of trouble-free service.
The only regular maintenance required is occasional de-scaling.
Descaling Procedure:
Isolate machine from power supply.
Isolate machine from water supply.
ALLOW TO COOL COMPLETELY!
Drain water from machine.
Remove all lids.
Remove as much scale as possible by hand, paying particular attention to level probes
(White plastic with steel tab). Be very careful not to damage any attachments.
Use ScaleKleen, Marco part No. 8000270 or similar. Follow instructions carefully.
Thoroughly clean and flush the machine before re-use.
Follow installation and first-time operation instructions.
CLEANING:
The exterior of these machines may be cleaned with a damp cloth and a light detergent. Do not use
abrasive cloths or creams, as this will spoil the finish of the machine. Do not use a water jet or spray.
NOTE: Beware of accidentally operating the draw off tap or push button when cleaning the front of
the machine.
LIMESCALE:
In common with all water boiler manufacturers, service calls resulting from limescale are not covered
by warranty. Fitting a scale reducer is recommended, especially in hard water areas. This can reduce
the build-up of scale but may not stop it altogether. The frequency that descaling is required depends
on the local water supply; hard water areas need more attention. Descaling of the machine should
ideally be carried out by qualified service personnel.
INSTRUCTIONS POUR MODÈLES
ECOBOILER T2
(N/P: 1000672 and 1000672#)
ECOBOILER T5
(N/P: 1000660 and 1000660#)
ECOBOILER T10
(N/P: 1000661 and 1000661#)
ECOBOILER PB5
(N/P: 1000665 and 1000665#)
ECOBOILER PB10
(N/P: 1000666 and 1000666#)
(Où # est un suffixe constitué d'une ou plusieurs lettres, sauf pour les modèles des États-Unis)
Pression d'aspiration principale autorisée:
Minimum 100 kPa / 0,1MPa / 1 bar / 14,5 psi
Maximum 1000 kPa / 1 MPa / 10 bar / 145 psi
Marco Beverage Systems Limited.
63d Heather Road,
Sandyford Industrial Estate,
Dublin 18.
Marco Beverage Systems Limited.
Shire House, Strixton Manor,
Strixton, Wellingborough, Northants,
NN29 7PA
Irlande Tél : 00353 (0) 1 295 2674
Irlande Fax : 00353 (0) 1 295 3715
Royaume-Uni Tél : 0044 (0) 1933 666
488
Royaume-Uni Fax : 0044 (0) 1933 666
968
www.marcobeveragesystems.com
ANLEITUNG FÜR DIE MODELLE
ECOBOILER T2
(Teilenr: 1000672 und 1000672#)
ECOBOILER T5
(Teilenr: 1000660 und 1000660#)
ECOBOILER T10
(Teilenr: 1000661 und 1000661#)
ECOBOILER PB5
(Teilenr: 1000665 und 1000665#)
ECOBOILER PB10
(Teilenr: 1000666 und 1000666#)
(Wobei # ein aus einem oder zwei Buchstaben bestehendes Suffix ist, ausgenommen Modelle für
USA)
Zulässiger Eingangswasserdruck:
Minimum: 100 kPa / 0,1 MPa / 1 bar / 14,5 psi
Maximum: 1000 kPa / 1 MPa / 10 bar / 145 psi
Marco Beverage Systems Limited.
63d Heather Road,
Sandyford Industrial Estate,
Dublin 18.
Marco Beverage Systems Limited.
Shire House, Strixton Manor,
Strixton, Wellingborough, Northants,
NN29 7PA
Irland Tel : 00353 (0) 1 295 2674
Irland Fax : 00353 (0) 1 295 3715
Vereinigtes Königreich Tel : 0044 (0)
1933 666 488
Vereinigtes Königreich Fax: 0044 (0)
1933 666 968
www.marcobeveragesystems.com
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ДЛЯ МОДЕЛЕЙ
ECOBOILER T2
(н/д: 1000672 and 1000672#)
ECOBOILER T5
(н/д: 1000660 and 1000660#)
ECOBOILER T10
(н/д: 1000661 and 1000661#)
ECOBOILER PB5
(н/д: 1000665 and 1000665#)
ECOBOILER PB10
(н/д: 1000666 and 1000666#)
(# окончание из одной или нескольких букв, за исключением моделей для США)
Допустимое гидравл. давление в системе водоснабжения на входе:
мин. 100 кПА/0,1 МПа/1 бар/14,5 фунта/кв. дюйм
макс. 1000 кПА/1 МПа/10 бар/145 фунтов/кв. Дюйм
Marco Beverage Systems Limited.
63d Heather Road,
Sandyford Industrial Estate,
Dublin 18.
Marco Beverage Systems Limited.
Shire House, Strixton Manor,
Strixton, Wellingborough, Northants,
NN29 7PA
Тел. в Ирландии : 00353 (0) 1 295
2674
Факс в Ирландии : 00353 (0) 1 295
3715
Тел. в Великобритании : 0044 (0) 1933
666 488
Факс в Великобритании : 0044 (0) 1933
666 968
www.marcobeveragesystems.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17

Marco Ecoboiler PB5 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI