Optimus AX-DVF2 User manual

  • Hello! I am an AI chatbot trained to assist you with the Optimus AX-DVF2 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INSTALLATION MANUAL
JD-003 2711
PRECAUTION
AXDVF2AL AXDVF4AL
2-4 BUTTON ANTIVANDAL FLUSH MOUNT VIDEO DOOR STATION
WITH ACCESSIBILITY
INSTRUCTION
Audio/vidéo Door Station connect with CAT5e/6 to an AX Control Unit
Wiring Distance: 300 m in CAT5 (24AWG) between Door Station and the AX Control Unit + 4*0,8mm² wire for power supply
and Door Realease
General
Prohibitions
Prohibitions to dismantle
the unit
General Precautions
Prohibitions to subject
the unit to water
CAUTION
(Negligence could result in injury to people or damage to property)
WARNING
(Negligence could result in death or serious injury)
1. The unit must be installed and wired by a qualified
technician.
2. Do not dismantle or alter the unit. Fire or electric shock
could result.
1. Do not install or make any wire terminations while power
supply is plugged in. It can cause electrical shock or damage to
the unit.
2. When mounting the unit on a wall, install the unit in a
convenient location, but not where it could be jarred or
bumped. Injury could result.
3. Before turning on power, make sure wires are not crossed or
shorted. Fire or electric shock could result.
4. Do not install the unit in any of the following locations. Fire,
electric shock, or unit trouble could result.
* Places under direct sunlight or near heating equipment that
varies in temperature.
* Places subject to dust, oil, chemicals, hydrogen sulfi de (hot
spring).
* Places subject to moisture and humidity extremes, such as
bathrooms, cellars, greenhouses, etc.
* Places where the temperature is low, such as inside a
refrigerated area or in front of an air conditioner.
* Places subject to steam or smoke (near heating or cooking
surfaces).
* Where noise generating devices such as dimmer switches or
inverter electrical appliances are closeby.
1. The unit will not work during power failure.
3. Keep the unit away from radio or TV sets.
4. Keep the intercom wires more than 30cm (12'') away
from AC 100-240V wiring. AC induced noise and/or unit
malfunction could
result.
5. For the wiring, use CAT5 wire.
GENERAL PRECAUTION
- 1 -
The Door station must be mounted on the Wall
1. Unscrew the panel.
2. Disconnect the conector who link the Front Panel to the Back Box.
3. Place the Back Box on the Wall.
4. Wired your Door Station.
5. Reconnect the connector from the Front Panel to the Back Box.
6. Screw the Front Panel.
1. Insert the Openning Tool on the left of the Name Plate (G).
2. Push on the Tool.
3. Name Plate is Open. Change the Name.
MOUNTING
Openning Tool
Installation Manual
Tool
AXDVF2AL
or
AXDVF4AL
Dimensions (mm)
Back Box:
375×130×65
405
150
- Name Change-
Openning Tool
Open
Name Plate
Name Plate
Openning Tool
(G)
AXDVF2AL or AXDVF4AL
- 2 -
External Power Supply 24VDC
(consumption: 15mA initial state , 30mA in emission, 60mA in door release)
Dry contact closure on P P terminal. A shunt on these 2 terminal activate the relay(the shunt is provide by the AX Control Unit)
AXDEL Door Release Contact on RCT terminal :
- normaly closed (NC) on R
- common on C
- normaly open(NO) on T
Loan Breaking capacity : 4A over 24VDC. Maximum voltage: 24VDC
Note : To take account of the programming, position switches and make a stop-start.
- The Language will be set with the position of SW1-2-3
- The emission of the messages can be set with the SW4 position. To enable it, put SW4 into the ON position
Language SW1 SW2 SW3
French ON ON ON SW4
English OFF ON ON OFF
Dutch ON OFF ON ON
Spanish OFF OFF ON
German ON ON OFF
Italian OFF ON OFF
TECHNICAL PRECAUTION
WIRING SCHEMATIC
SYNTHESIS MODULE
Message inhibited
Message emited
AIPHONE S.A.S.
Wiring Distance:300 meters max between Door Station et AX Control Unit(AX084C,AX248C).
For the other Technical precautions please see the AX Installation Manual(AX084C,AX248C).
AXDVF
D
CEV0901A
PCB for AXDVF2/4
AX-DV
D1
D2
D3
D4
AX084C
AX248C
AX320C
Dn
Dn
Dn
Dn
AXDEL
+24V
-24V
+
-
P
P
T
C
R
+
-
PS2420D
AXDVF2AL, AXDVF4AL
L
L
- The openning delay can be set from 1s to 20s with the POT potentiometer
- 3 -
WARANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a
period of two years after delivery to the ultimate user and will repair free of charge or replace at no charge,should it become defective upon
which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision
whether there is a defect in materials and/or workmanship;and whether or not the product is within the warranty. This warranty shall not
apply to any Aiphone product which has been subject to misuse,neglect ,accident,or to use in violation of instructions furnished,nor
extended to units which have been repaired or altered outside of the factory.This warranty does not cover batteries or damage caused by
batteries used in connection with the unit.This warranty covers bench repairs only,and any repairs must be made at the shop or place
designated in writing by Aiphone.Aiphone will not be responsible for any costs incurred involving on site service calls. .
AIPHONE S.A.S.
LISSES EVRY
Printed in France
- 4 -
/