  • Hello! I am an AI chatbot trained to assist you with the Paradyne COMSPHERE 3610 Release note. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
16800-A2-GK66-20 October 1996
TM
COMSPHERE 6800 Series Network Management System
3800
Plus,
3821
Plus
, 3821
Plus
/3825
Plus
Release 4.0, 3610/3611 ISDN DBM, 3610/3611
V.34 DBM, 3600 R3.5 DSUs, and 392x R3.1 Modems Release Notes
Document Number 6800-A2-GK66-20
October 1996
Overview
This document describes information for the 3821Plus modems, 3821Plus/3825Plus Release 4.0 modems, and the
two 3610/3611 DBMs (ISDN and V.34), plus information on the Synchronous Data Compression feature in
support of the 3800Plus R3.0 release. These release notes also have been updated to include support for the
3600 R3.5 and 392x R3.1 device releases.
NOTE
Although this document contains information on the V.34 DBM, this card
may not be available at the time of the release of this document. Please
contact your sales representative for more information.
2
October 1996 6800-A2-GK66-20
Release Notes Summary
In the COMSPHERE 6800 Series Network Management System Communications Products Support Command
Reference Manual (6800-A2-GB31-10), the following commands are new or enhanced:
Call Detail Display (cded)
Call Duration Distribution (cdud)
Call Occurrence Distribution (cod)
Call Test (ct)*
Change Address (cha)
Change Options (cho)
Change SPID (chspid)*
Change Telephone Number (chtn)
Configuration Change Notification (ccn)
Daily Historical Utilization (dhu)
Display Options (dso)
Display SPID (dsspid)*
Display Telephone Number (dstn)
Download Device Firmware (dndf)
Identity (id)
Manage Call Statistics (mcs)
Reset Device (rs)*
In the COMSPHERE 6800 Series Network Management System Users/System Administrators Guide
(6800-A2-GE26-10), Table 5-2 is updated to include new alarms. Table A-1 in Appendix A is changed to reflect
the new device number 3821.
In the COMSPHERE 6800 Series Network Management System Command Quick Reference Guide
(6800-A2-GB15-10), two new menu items are added to the DDD Service Restoration menu to support the SPID
commands. The DDD Device Control menu and the DSU Device Control menu were both updated with one
menu item to support the Reset Device (rs) command. The DDD Circuit Test menu was updated with one menu
item to support the Call Test (ct) command.
In the COMSPHERE 6800 Series Network Management System Communications Products Support
Configuration Guide (6800-A2-GB20-10), two new commands added to Table 1-2.
In the COMSPHERE 6800 Series Network Management System Core Command Reference Manual
(6800-A2-GB30-10), new values are added to the Access module id field of the crdp, dldp, dsdp, and eddp
commands.
*Call Test (ct) and Reset Device (rs) are new commands. Change SPID (chspid) and Display SPID (dsspid) are new
commands from an earlier release.
36800-A2-GK66-20 October 1996
COMSPHERE 6800 Network Management System
Communications Products Support Command
Reference Manual (6800-A2-GB31-10)
The changes, modifications, or additions to the commands in this manual are described on the following pages.
Call Test (ct)
Change Address (cha)
Change Options (cho)
Change SPID (chspid)
Change Telephone Number (chtn)
Configuration Change Notification (ccn)
Display Options (dso)
Display SPID (dsspid)
Display Telephone Number (dstn)
Download Device Firmware (dndf)
Identity (id)
Reset Device (rs)
The Call Statistics application functionality now supports 3821Plus modems in the same capacity that is currently
being provided for the 3800 Series modems. The following is a list of commands that are provided in this
application and are affected:
Call Detail Display (cded)
Call Duration Distribution (cdud)
Call Occurrence Distribution (cod)
Daily Historical Utilization (dhu)
Manage Call Statistics (mcs)
56800-A2-GK66-20 October 1996
Call Test (ct)
The Call Test (ct) command performs dial test for the 3600 Series R3.5 DSUs. This command can be scheduled
and the destination for results can be specified.
The input screen contains the following fields.
Device
This field specifies the device to be tested.
Test Type
This field indicates the kind of dial test to be performed. Currently, the field only accepts dial tone so it
cannot be changed.
The results screen provides the information resulting from the test:
Call Test passed
Call Test failed – No dial tone
76800-A2-GK66-20 October 1996
Change Address (cha)
This command is supported for 3821Plus modems.
96800-A2-GK66-20 October 1996
Change Options/Display Options (cho/dso) Commands
The following changes and additions apply to both the Change Options (cho) and Display Options (dso)
commands in support of 3821Plus modems.
The SECURITY Configuration Set screen contains one new field: Callback security. The values are
disable and enable. This field is displayed as a protected field for the standalone (3825), but as a required
field for the carrier-mounted cards (3821).
The following changes and additions apply to both the Change Options (cho) and Display Options (dso)
commands in support of 3600 Series R3.5 DSUs.
The GENERAL screen has a new field, Power on selftest, which accepts the following values: enable and
disable.
The DSU Configuration Set screen’s Aggregate switch field name is changed to Network int switch.
The DBM Configuration Set screen’s Fallback rate 1 (Kbps) and Fallback rate 2 (Kbps) fields no longer
accept disable. The Standby test field name is changed to Backup timer.
The MUX Configuration Set screen’s Bridge rate field accepts the following new values: 16.8, 24.0, 28.8,
and 64.
The following changes and additions apply to both the Change Options (cho) and Display Options (dso)
commands in support of 3610/3611 DSUs.
The DSU Configuration Set screen’s Aggregate switch field is changed to reflect the following values:
switched, disabled, and forced-on.
The DBM Configuration Set screen contains five new fields: Fallback, Switch type, Fallback
rate 1 (Kbps), Fallback rate 2 (Kbps), and Standby test. A pop-up menu is available listing all valid
selections. The DBM rate (Kbps) field contains the new values of 7.2, 16.8, 19.2, 21.6, 24.0, 26.4, 28.8,
and 64. The Single rate field with the values yes and no only displays if the DBM is a 12K or 14.4K DBM.
The DBM Diagnostic Configuration Set screen contains four new fields: DBM diag choice at FB1, DBM
SC speed at FB1, DBM diag choice at FB2, and DBM SC speed at FB2. A pop-up menu is available
listing all valid selections.
The Port Configuration Set screen for Single Port DSUs contains two new fields: Port rate at FB1 and
Port rate at FB2. A pop-up menu is available listing all valid selections. The DSU port rate field contains
new values. The new selection set is disable, 1.2, 2.4, 4.8, 7.2, 9.6, 12, 14.4, 16.8, 19.2, 38.4, 48, 56, 64, 2,
4, 8.4, 18, 32, 28.8, 4.4, 9.2, 18.8, 21.6, 24.0, 26.4. The DBM port rate field contains new values. The new
selection set is disable, 1.2, 2.4, 4.8, 7.2, 9.6, 12, 14.4, 16.8, 19.2, 2, 4, 8.4, 18, 32, 38.4, 48, 56, 28.8, 4.4,
9.2, 18.8, 21.6, 24.0, 26.4, 64.
The Port n (n=1–6) Configuration Set screen for the multiplexers contains one new field: DCE type which
accepts two values: analog and digital. (If the FEP port x/y sharing fields (x=1, 3, 5; y=2, 4, 6) in the
second page of MUX configuration set screen is disabled, the DCE type fields under the related ports will
be filtered. For example, if the field FEP port 1/2 sharing is disabled, then DCE type fields under Port 1
and Port 2 configuration set screens will be filtered.)
The Port Speeds Configuration Set screen for multiplexers contains selections for Port 1 through Port 6.
The new selection set for DDS rate (Kbps) is disable, 1.2, 2.4, 4.8, 7.2, 9.6, 12, 14.4, 16.8, 19.2, 38.4, 48,
56, 64, 2, 4, 8.4, 18, 32, 28.8, 4.4, 9.2, 18.8, 21.6, 24.0, 26.4. The new selection set for DDD rate (Kbps) is
disable, 1.2, 2.4, 4.8, 7.2, 9.6, 12, 14.4, 16.8, 19.2, 2, 4, 8.4, 18, 32, 38.4, 48, 56, 28.8, 4.4, 9.2, 18.8, 21.6,
24.0, 26.4, 64.
10
October 1996 6800-A2-GK66-20
The Fallback Speeds Configuration Set screen for multiplexers contains selections for Port 1 through
Port 6. The new selection set for FB1 rate (Kbps) is disable, 1.2, 2.4, 4.8, 7.2, 9.6, 12, 14.4, 16.8, 19.2, 2,
4, 8.4, 18, 32, 38.4, 48, 56, 28.8, 4.4, 9.2, 18.8, 21.6, 24.0, 26.4. The new selection set for FB2 rate (Kbps)
is disable, 1.2, 2.4, 4.8, 7.2, 9.6, 12, 14.4, 16.8, 19.2, 2, 4, 8.4, 18, 4.4, 9.2, 18.8, 21.6, 24.0. The following
new options have single fields: FB1 underspeed which accepts 1, 2, 3, 4, 5, 6, and disable; FB2
underspeed which accepts 1, 2, 3, 4, 5, 6, and disable.
The following changes and additions apply to both the Change Options (cho) and Display Options (dso)
commands in support of 392x modems.
The DTE INTERFACE Configuration Set screen contains two new values for the Async DTE rate field:
76800 and 115200. A pop-up menu is available listing all valid selections. The new field Sync DTE rate
contains the values 115200, 76800, 57600, 38400, 28800, 19200, 14400, 9600, 4800, 2400, and 1200.
The LEASED LINE Configuration Set screen contains a new value for the Auto dial backup field:
circular. A pop-up menu is available listing valid selections. Two new fields were added: 2 sec LSD hold
which contains the values disable and enable; and TMp TxPreValue which contains the values 0, 1, 2, 3,
4, 5, 6, 7, 8, 9, A, B, C, D, E, F.
The V42/MNP/BUFFER Configuration Set screen contains five new fields: Sync Compression mode,
Sync flow control, SDC negotiation, SDC idle fill, and SDC bit encoding. The values for the Sync
compression mode field are directMode and HDLC/SDLC. The values for the Sync flow control field
are none, Tx Clock and CTS_Sync. The values for the SDC negotiation field are LAPM_Buffer,
LAPM_Discon. The values for the SDC idle fill field are DirectMode and Mark_Fill. The values for
SDC bit encoding field are NRZ and NRZI.
The MISC Configuration Set screen contains the new field Mixed trib F/W with the values of yes and no.
The new COMMON MUX Configuration Set Screen contains four new fields: Port 1 DTE alarm mask,
Port 2 DTE alarm mask, Port 3 DTE alarm mask, and the Port 4 DTE alarm mask. These fields
contain the values disable and enable.
The following changes and additions apply to both the Change Options (cho) and Display Options (dso)
commands in support of 392x R3.1 modems.
The DTE INTERFACE Configuration Set screen has new selections added to the Sync DTE rate field.
The updated selection set for this field consists of the values 128000, 115200, 112000, 96000, 76800,
72000, 64000, 57600, 56000, 48000, 38400, 28800, 19200, 14400, 9600, 4800, 2400, and 1200. Two new
fields were added: DTE alarm mask which contains the values disable and enable; and Port4 external
alarm which contains the values disable, enableLow, and enableHigh.
The DIAL LINE Configuration Set screen has a name change for an existing field. The V32bis autorate
(dial) field is changed to autorate. The selection set for the autorate field was updated to accept the values
enable, disable, strt 48, strt 96, and fast. Two new fields were added: V34 symbol rate which contains
the values automatic, 3429L, 3429H, 3200L, 3200H, 3000L, 3000H, 2800L, 2800H, 2743L, 2743H,
2400L, and 2400H; and V34 precoder which contains the values enable and disable.
The LEASED LINE Configuration Set screen has a name change for an existing field. The V32bis
autorate (leased) field is changed to autorate. The selection set for the autorate field was updated to
accept values enable, disable, and fast.
The SECURITY Configuration Set screen contains the new field Special security with the values of
disable, RmtAccPsw, and ClbkDirNum. (RmtAccPsw means Remote Access Password and ClbkDirNum
means Callback Directory Number.)
116800-A2-GK66-20 October 1996
The following changes and additions apply to both the Change Options (cho) and Display Options (dso)
commands in support of 3800Plus R3.0 modems.
The DTE INTERFACE Configuration Set screen contains the new field Sync DTE rate. The values for
this field are 128000, 115200, 112000, 96000, 76800, 72000, 64000, 57600, 56000, 48000, 38400, 28800,
19200, 14400, 9600, 4800, 2400, and 1200.
The DTE DIALER Configuration Set Screen has a new value range for the AT escape char field: 1–255.
The V42/MNP/BUFFER Configuration Set screen contains seven new fields: Sync Compression mode,
SDC negotiation, SDC idle fill, SDC bit encoding, Sync DTE CRC, Sync flow control, and SDC delay
min. The values for the Sync compression mode field are directMode and HDLC/SDLC. The values for
the SDC negotiation field are LAPM_Buffer, LAPM_Discon. The values for the SDC idle fill field are
Flag_Fill and Mark_Fill. The values for SDC bit encoding field are NRZ and NRZI. The values for the
Sync DTE CRC field are Ignore and CRC16. The values for the Sync flow control field are none, Tx
Clock and CTS_Sync. The values for the SDC delay min field are Off and Rx Clock.
136800-A2-GK66-20 October 1996
Change SPID (chspid)
The new Change SPID (chspid) command supports 3610/3611 DSUs.
The following field appears on page 1 of the Change SPID input form.
Device
This field specifies the device whose SPID numbers are to be changed. Standard addressing format applies.
The following fields appear on page 2 of the Change SPID input form.
SPID number at B1
This field specifies the SPID number at B1. A valid SPID number consists of the ASCII characters 0–9 with
a length of 3–20. If the field is left blank, the SPID will be removed.
SPID number at B2
This field specifies the SPID number at B2. A valid SPID number consists of the ASCII characters 0–9 with
a length of 3–20. If the field is left blank, the SPID will be removed.
Set CCN event
This field specifies whether to set the CCN event.
The Change SPID results form lists device information for the specified device and redisplays the SPID numbers
specified by the user.
156800-A2-GK66-20 October 1996
Change/Display Telephone Number (chtn/dstn) Commands
This command was changed to support two local phone numbers for ISDN DBMs (ISDN DBM and DBM-I).
The new fields are as follows:
Local number 1
For the first local telephone number, this field accepts 36 characters with the same character set as the
non-ISDN DBM single local number.
Local number 2
For the second local telephone number, this field accepts 36 characters with the same character set as the
non-ISDN DBM single local number.
The phone number format (one local phone number) for non-ISDN DBM devices did not change.
176800-A2-GK66-20 October 1996
Configuration Change Notification (ccn)
A ccn event message was added for the Change SPID (chspid) command when the ccn command is used to
display the configuration events. In the description of the Configuration Change Notification results screen in the
manual, add change SPID to the CATEGORY list and add display SPID to the UPDATE COMMAND list.
196800-A2-GK66-20 October 1996
Device Health and Status (dhs)
The Expanded Status field for 3600 Series R3.5 DSUs can now display the following facility alarms.
facility alarm – rate conflict alarm
facility alarm – cross pair detection alarm
facility alarm – secondary channel conflict
facility alarm – no sync
216800-A2-GK66-20 October 1996
Display SPID (dsspid)
The new Display SPID (dsspid) command supports 3610/3611 DSUs. The input form contains the following
field:
Device
This field specifies the device(s) for which the SPID numbers are to display.
The Display SPID results form lists device information for each specified device.
236800-A2-GK66-20 October 1996
Download Device Firmware (dndf)
This command supports 3821Plus modems. The valid selections for the Type of download field are ddd remote
and ddd local.
NOTE
If the user is experiencing failure in the Broadcast Download process, turn
off channel polling and increase the timeout interval (2 seconds is
recommended) by performing the following steps:
1. Enter the Edit Alert Monitoring State
(edams)
command.
2. On the
edams
screen, select the channel where the 3821
Plus
modems
receiving download data are connected.
3. To the channel selected in Step 2, set the Alert Monitoring State field to
off and the Timeout Interval (Sec) field to 2.
4. Click on Go to execute the
edams
command.
256800-A2-GK66-20 October 1996
Identity (id)
The results form now displays 3821 with ddd Service class in the Model field in support of 3821Plus modems.
The following new values appear in the Facility restoral option field in support of 3610/3611 DSUs.
ISDN DBM
V.34 DBM
DBM-I (ISDN DBM)
DBM-F (V.34 DBM)
The new country code Czech Republic is supported in the Modem strapping field for 392x modems.
A new field is valid, Special Functions with the option XLOOP, to support the 3610 and 3611 Release 3.3c
DSUs.
The feature SDC (Synchronous Data Compression) displays in the Installed Features field when the 3800Plus
Release 3.0 is installed.
The following Country Codes are supported in the Modem strapping field for 3821Plus/3825Plus modems.
North America Spain
Generic Austria
Japan Denmark
UK Sweden
Italy Norway
Germany Finland
Belgium Cyprus
Australia Portugal
New Zealand Singapore
France Malaysia
Switzerland Turkey
Netherlands
276800-A2-GK66-20 October 1996
Reset Device (rs)
The Reset Device (rs) command allows users to reset the 3600 Series R3.5 DSUs. This command can be
scheduled and the destination for results can be specified.
The input screen contains the following field.
Device(s)
This field specifies the device(s) to be reset.
The results are sent before the reset occurs.
296800-A2-GK66-20 October 1996
COMSPHERE 6800 Network Management System
Communications Products Support Configuration Guide
(6800-A2-GB20-10)
The changes or modifications to the commands in this guide are described as follows.
Table 2-1 is updated to include two new commands.
Command
Command
Abbreviation
APL/DDD/DDS Disruptive Usage
Call Test
ct
DDD No Used to perform dial
tests for 3600 Series
DSUs.
Reset Device
rs
DDS Yes Used to reset
3600 Series DSUs.
316800-A2-GK66-20 October 1996
COMSPHERE 6800 Network Management System Users/System
Administrators Guide (6800-A2-GE26-10)
The changes or modifications to the commands in this guide are described as follows.
Table 5-2 is updated with two alerts added to the Alert Group apl-terminal. The Alert Type ela has a textual
display of “External alarm A” and Alert Type elb has a textual display of “External alarm B.” Both alerts have a
priority of 1.
336800-A2-GK66-20 October 1996
COMSPHERE 6800 Network Management System Command
Quick Reference Guide (6800-A2-GB15-10)
The modifications in this guide are described as follows.
The DDD Service Restoration Menu was updated to include the following additional menu items:
5) chspid – Change SPID
6) dsspid – Display SPID
The DDD Device Control menu was updated to include the following additional menu item:
5) rs – Reset Device
The DSU Device Control menu was updated to include the following additional menu item:
4) rs – Reset Device
The DDD Circuit Tests menu was updated to include the following additional menu item:
3) ct – Call Test
356800-A2-GK66-20 October 1996
COMSPHERE 6800 Network Management System Core
Command Reference Manual (6800-A2-GB30-10)
The changes or modifications to the commands in this manual are described as follows.
Create Device Profile (crdp)/Delete Device Profile(dldp)/
Display Device Profile (dsdp)/Edit Device Profile (eddp)
The Access module id field of the Create Device Profile (crdp), Delete Device Profile (dldp), Display Device
Profile (dsdp), and the Edit Device Profile (eddp) commands now accepts the following values for Sequoia
applications:
Sequoia Sequoia application present.
TDM CCA/Sequoia Time Division Multiplexer Circuit Card and Sequoia application present.
TDM CCA/CBrdg-S Time Division Multiplexer Circuit Card, Central Site Digital Bridge and
Sequoia application present.
MCMP CCA/
Sequoia
Multichannel Multipoint Circuit Card and Sequoia application present.
MCMP
CCA:CBrdg-S
Multichannel Multipoint Circuit Card, Central Site Digital Bridge and Sequoia
application present.
V.35/232 TDM CCA/
Sequoia
V.35/232 Time Division Multiplexer Circuit Card and Sequoia application
present.
V.35/232 TDM
CCA/CBrdg-S
V.35/232 Time Division Multiplexer Circuit Card, Central Site Digital Bridge
and Sequoia application present.
V.35/232 MCMP
CCA/Sequoia
Multichannel Multipoint Circuit Card and Sequoia application present.
V.35/232 MCMP
CCA/CBrdg-S
Multichannel Multipoint Circuit Card, Central Site Digital Bridge, and Sequoia
application present.
2-p Flex TDM CCA/
Sequoia
Time Division Multiplexer Circuit Card and Sequoia application present.
2-p Flex TDM
CCA/CBrdg-S
Time Division Multiplexer Circuit Card, Central Site Digital Bridge, and
Sequoia application present.
2-p Flex MCMP
CCA/Sequoia
Multichannel Multipoint Circuit Card and Sequoia application present.
2-p Flex MCMP
CCA/CBrdg-S
Multichannel Multipoint Circuit Card, Central Site Digital Bridge, and Sequoia
application present.
4-p Flex TDM
CCA/Sequoia
Time Division Multiplexer Circuit Card and Sequoia application present.
4-p Flex TDM
CCA/CBrdg-S
Time Division Multiplexer Circuit Card, Central Site Digital Bridge, and
Sequoia application present.
4-p Flex MCMP
CCA/Sequoia
Multichannel Multipoint Circuit Card and Sequoia application present.
4-p Flex MCMP
CCA/CBrdg-S
Multichannel Multipoint Circuit Card, Central Site Digital Bridge, and Sequoia
application present.
6-p Flex TDM CCA/
Sequoia
Time Division Multiplexer Circuit Card and Sequoia application present.
/