Davey 62101 Operating instructions

Type
Operating instructions

This manual is also suitable for

Please pass on these instructions on to the operator of this equipment.
Electric Pumps
Models: 60061R, 6200, 6210, 6220, 6230
Installation and Operating
Instructions
Dynaflo
®
Prior to using this pump you must ensure that:
The pump is installed in a safe and dry environment
The pump enclosure has adequate drainage in the event of leakage
Any transport plugs are removed
The pipe-work is correctly sealed and supported
The pump is primed correctly
The power supply is correctly connected
All steps have been taken for safe operation
Appropriate details for all of these items are contained in the following Installation and
Operating Instructions. Read these in their entirety before switching on this pump. If you
are uncertain as to any of these Installation and Operating Instructions please contact your
Davey Dealer or the appropriate Davey ofce as listed on the back of this document.
WARNING: Failure to follow these instructions and comply with all applicable codes may cause
serious bodily injury and/or property damage.
WARNING: Some insects, such as small ants, nd electrical devices
attractive for various reasons. If your pump enclosure is susceptible to
insect infestation you should implement a suitable pest control plan.
2
Read all instructions before Installing your
new Dynao Pump
1. INTRODUCTION
These instructions have been prepared to
acquaint you with the correct method of installing
and operating your Dynao pump. We urge you
to study this publication carefully and follow its
recommendations. In the event of installation
difculties or the need for further advice you
should contact the Davey Dealer from whom you
purchased the unit.
Should you be unable to obtain the required advice
or resolve any problems through your local Davey
Dealer, please contact the Davey Customer Service
Centre. Contact details for these Ofces are shown
at the back of these instructions.
For suitability of Dynao for pumping liquids other than
water, consult the Davey Customer Service Centre.
2. HOUSING YOUR Dynao
As the pump is an electrical apparatus it must
be protected from the weather, at the same time
adequate ventilation must be provided for the motor.
Do not enclose the pump in such a manner that a
“hotbox” condition is created. Ventilation should be
provided near the top of any enclosure to prevent a
“buildup” of condensation.
Your Dynao should be mounted on a rm base
high enough to prevent any surface water that may
accumulate from coming into contact with the unit.
Positioning of the unit should allow the nameplate
to be easily read and provide adequate access for
service purposes.
Failure to adequately house your Dynao, as
outlined above, will render your guarantee void.
3. SUCTION LIFT
For best performance and easiest priming, site the
pump as close to the water source as possible.
Optimum performance will be achieved on suction
heads (including friction) up to 4.5m (15 feet). The
maximum practical suction head (including friction)
for this type of pump is 7.5m (25 feet).
4. DELIVERY HEAD
Care should be taken to ensure that the combined
suction and delivery head (including pipe friction) of
the installed pump does not exceed the total head
shown in the pump performance tables against the
required capacity.
Never run this pump without
discharge ow for more than a few
minutes, as the water will heat and
cause damage to the pump or pipe
lines not covered by guarantee.
5. FOOT VALVE - CHECK VALVE
IMPORTANT: For installations which
may allow water to run back through
the pump after switching off (eg
overhead tank lling), a check valve
(non-return valve) must be installed
at the pump outlet to prevent water
cascading back through pump.
6. SUCTION PIPING
Suction lift is made up of the actual vertical height
from the water level below the pump to the pump
inlet port, plus the friction in the suction piping
and ttings. For best performance and easiest
priming situate the pump as close to the water
source as possible.
Suction piping should be laid so there is a constant
rise from the water source to the pump. Any high
spots will cause air pockets to form and reduce the
efciency of the system.
Do not allow the suction pipe to
lay in exposed sunlight if possible
as the water inside will heat up
during periods when the pump is
not operating. This will reduce the
suction capacity of the pump during
initial starting.
To reduce pipe friction and maximise ow we
recommend the use of pipe with equal or larger
diameter than the inlet on your pump. For detailed
recommendations regarding long suctions, please
contact your Davey Dealer or the Davey Customer
Service Centre on 1300 367 866.
NOTE: Suction leaks are THE biggest
cause of operating difculties and are
hard to detect because the problem
is air leaking INTO the pipe and
there may be no external sign of the
leak. It is essential that all suction
connections are completely sealed,
using thread sealing tape only.
Do NOT screw connections too far into the pump’s
suction and delivery ports. Do not exceed tightening
force of 60ft lb (8.2kgm). i.e. 60lb force at the end of
1 foot wrench (25kg at 30 cm).
7. DELIVERY PIPING
Friction in the delivery increases the head on
the pump and so reduces capacity and pressure
available at the delivery point. To minimise
performance losses we recommend the use of
larger diameter pipe. For more detailed advice
concerning delivery heads and delivery piping,
please consult your local Davey Dealer or the
Davey Customer Service Centre on 1300 367 866.
3
8. POWER CONNECTION
In accordance with AS 3350.2.41 we
are obliged to inform you that this
pump is not to be used by children or
inrm persons and must not be used
as a toy by children.
The electrical connections and
checks must be made by a
qualied electrician and comply
with applicable local standards.
NOTE:
1. Ensure motor is connected
to power supply specied
on nameplate.
2. Avoid long extension leads as
they can cause substantial voltage
drop and operating problems.
3. Although the Davey Dynao electric
motor is specically engineered
to perform on a range of power
supply voltages, malfunctions
or failure caused by adverse
voltage supply conditions are
not covered under guarantee.
Single Phase
The single phase Models 6200, 6210 & 6220,
are supplied with a 10 amp plug or a special
15 amp power plug which may only be used
with the appropriate 10 or 15 amp 220/250V
power outlet (15 amp power outlets are usually
specially provided by an electrician).
Always ensure that the earth conductor in
the lead is connected to a good earth.
The Dynao single phase pump motor is
designed and manufactured by Davey specially
for this particular pump. It has no switch gear
as this motor is the P.S.C. type. The capacitor
is located inside the capacitor cover.
The Davey single phase pump motor is tted
with an inbuilt automatic reset thermal overload.
This overload is designed to protect the motor
from an overloading condition. Constant stopping
and starting of the motor by this overload would
indicate a problem to be rectied before use:
e.g. low voltage at pump (below 216 volts),
excessive ambient temperatures (above 45°C).
WARNING: Automatic reset thermal
overloads will allow the pump to restart
without warning. Always disconnect
the pump motor from the electrical
supply before maintenance or repairs.
The single phase Dynao 6220 may
also be wired to a nominal 480V power
supply, but must be reconnected at
the terminals under the motor end
cap/terminal cover, and wire in with
a contactor. In addition, the overload
tted to the pump is only suitable for
220/250V, and must be exchanged for
the 480V overload supplied.
480V OVERLOAD (where applicable)
This 240/480V single phase motor is
factory connected for use on nominal
240V AC power supply. When the
units are to be reconnected to suit a
nominal 480V supply, overload P/No.
48154 must be tted into the motor
endshield in place of standard overload.
Reconnection for 480V must be carried
out by an authorised electrician as per
wiring diagram.
Three Phase
Three phase models are designed for connection
to a nominal 415V power supply, but must be wired
with a contactor with ‘quicktrip’ overloads set at 5.2
amps for Model 6220, and 7 amps for Model 6230.
Davey recommend the use of overloads which
also have the ability to detect “single phasing” or
“dropped phase” conditions in the power supply.
Three phase Dynao models have been designed
to allow for connection either side of the Capacitor
Cover (marked “A” in gure one) on the motor.
(NOTE: Three phase motors do not have
capacitors tted in the Capacitor Cover).
This is achieved by way of either of the two
19mm access holes (marked “B” in gure one).
The access holes are designed to accept most
standard cable grommets. The unused hole can
be sealed by inserting the plug enclosed with the
pump. To connect a three phase Dynao pump
start by removing the Terminal Cover (“C”).
4
A short four core ex (“D”) is tted from the motor
terminals (“E”). This lead is inserted through the
Blanking Grommet (“F”). Pressure switch or other
control leads (“G”) can be tted as well. Incoming
power (“H”) can be tted through the preferred
access hole, and terminated as shown in Figure
Three. A termination kit is available if required.
Insert the Blanking Grommet (“F”)
into the Capacitor Cover (“A”).
Fix the short lead (“D”) into the path
provided in the non-drive endshield and
replace the Terminal Cover (“C”).
IMPORTANT NOTE: - THREE
PHASE MODELS ONLY
Before nalising wiring connections,
check that motor rotates in direction
of arrow (clockwise when shaft is
viewed from wiring connection end).
To alter rotation, change any two
power leads at motor terminals.
When the unit is connected and operating the
phase balance should be checked. This should be
within 5% variation. “Rolling” the leads may help
to improve a small unbalance, but major phase
unbalance will usually be attributable to an input
power unbalance. This must be addressed before
the pump is used.
Power connections and wiring
must be carried out by an
Authorised Electrician. Means of
disconnection must be incorporated
in the xed wiring, in accordance
with local wiring rules.
9. PRIMING AND OPERATION
The pump body and suction line should be
lled by pouring water into the priming plug
hole adjacent to the outlet. Screw on the
priming plug, close the discharge valve two
thirds and switch pump on. Gradually open
the discharge valve and the pipeline lls.
In high suction lift conditions, the pump may
make a noise similar to it pumping sand or
gravel; this will usually be cavitation occurring.
Reduce ow until the cavitation noise stops.
Once the discharge pipeline lls you can open
the valve. If the cavitation noise returns, close
the discharge valve slightly until it stops.
In the case of installations where there is a positive
suction pressure (ooded suction) remove the
pump’s priming plug and slowly open the gate valve
in the suction piping to allow water to enter the
pump from the suction line until all air is expelled.
Replace the priming plug and fully open the gate
valve in the suction line and switch the pump on.
Prime should be established almost immediately,
however, it may be necessary to re-prime several
times on some installations before fully established
optimum pump performance is obtained.
Do not run pump dry or allow to
run continuously in a loss of prime
condition.
If this pump is allowed to pump water
containing sand or other abrasive
material, the effective life of the pump
will be shortened.
If pump runs but will not pump water, check for the
following:
1. Suction line and pump body not lled with water.
2. Leaking foot valve.
3. Air leaks in suction lines.
4. Air trapped in suction line (even on ooded
suction) possibly when there is an uneven rise in
the piping from water to pump (eliminate “humps
and hollows”).
NOTE: Prior to commencing
ANY maintenance on your
Dynao pump ensure that the
pump motor is disconnected
from the electrical supply.
5
10. TROUBLE SHOOTING
A. If Motor Runs but Pump Does Not Deliver
Water or Flow Rate is Reduced
One or more of the following may be the cause:-
1. Pump not primed:
Refer Instructions on Priming and Operation.
2. Leaks in piping or from seal:
Check suction piping and repair any leaks. A
leaking seal may also prevent pump operating.
3. Low water level:
Foot valve (entry) out of water or suction lift too
great because of reduced water level. Extend
piping and/or re-site pump closer to the water.
4. Total pump delivery head too great:
Calculate total pump head and check against
pump’s published performance. Reduce head,
use larger pipe or use higher head pump.
5. Piping or pump blocked:
Check both piping and pump internals
and unblock as required. Special attention
should be paid to inspecting the internals
of the impeller for blockages.
6. Defective valves:
Check that foot valve can open and valves
in piping will allow water to pass (are they
installed in the correct direction?) Repair
or replace any defective valves.
7. Incorrect direction of rotation - 3 phase models:
Check that impeller rotates in an anti-clockwise
direction when viewed from suction end.
To change direction of rotation
for 3 phase models, swap any
two power leads at motor - refer
“Power Connection Instructions”.
B. If Motor Fails to Run
One or more of the following may be the cause:-
1. Pump not connected:
Check power point with portable appliance
to ensure power is available. Check
fuses and main power supply switch.
2. Voltage too low:
Remove any long extension leads and try
pump again. Eliminate long leads or replace
with heavier, higher capacity leads.
3. Overload tripped:
Allow motor to cool and overload
will re-set. Determine the cause of
overload tripping and rectify.
4. Motor not free to turn:
Remove end cap/terminal cover, and
using a correctly sized (16mm) socket
spanner on end of shaft, check that motor
shaft is free to turn. If not free, remove
pump body and rectify cause of binding.
5. Internal motor fault:
Have unit checked by your local Davey Dealer.
11. SPARE PARTS
When ordering spare parts it is essential
to give both pump model and motor type
numbers from nameplate as well as the
full description on part required.
*NOTE: For protection, the Davey
pump motor is tted with an
automatic reset thermal overload,
constant tripping of this overload
indicates a problem e.g. low voltage
at pump, excessive temperature
(above 50°C) in pump enclosure.
Warning: Automatic reset thermal
overloads will allow the pump
to restart without warning.
Always disconnect the pump
motor from the electrical supply
before maintenance or repairs.
WARNING: When servicing
or attending pump, always
ensure power is switched off
and lead unplugged. Electrical
connections should be serviced
only by qualied persons.
Care should also be taken when
servicing or disassembling pump
to avoid possible injury from hot
pressurised water. Unplug pump,
relieve pressure by opening a tap on
the discharge side of the pump and
allow any hot water in the pump to
cool before attempting to dismantle.
IMPORTANT: DO NOT USE
petroleum based uids or solvents
(e.g. Oils, Kerosene, Turpentine,
Thinners, etc) on the plastic pump
components or seal components.
WARNING: Do not use hydrocarbon
based or hydrocarbon propelled
sprays around the electrical
components of this pump.
6
* A Quick Reference Guide is included with the product when purchased new, for detailed instructions please visit daveywater.com,
scan the QR code on the Quick Reference Guide / Davey product label (if applicable) or contact your local Davey Office.
® Davey is a trademark of Davey Water Products Pty Ltd. © Davey Water Products Pty Ltd 2020.
Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517
NORTH AMERICA
Ph: 1-877-885-0585
AUSTRALIA
Head Offi ce
6 Lakeview Drive,
Scoresby, Australia 3179
Ph: 1300 232 839
Fax: 1300 369 119
Email: sales@davey.com.au
daveywater.com
NEW ZEALAND
7 Rockridge Avenue,
Penrose, Auckland 1061
Ph: 0800 654 333
Fax: 0800 654 334
EUROPE
ZAC des Gaulnes
355 Avenue Henri Schneider
69330 Meyzieu, France
Ph: +33 (0) 4 72 13 95 07
Fax: +33 (0) 4 72 33 64 57
Email: info@daveyeurope.eu
MIDDLE EAST
Ph: +971 50 6368764
Fax: +971 6 5730472
P/N 48294-12
Davey Warranty
Davey Water Products Pty Ltd (Davey) warrants all products
sold will be (under normal use and service) free of defects in
material and workmanship for a minimum period of one (1)
year from the date of original purchase by the customer as
marked on the invoice, for specic warranty periods for all
Davey products visit daveywater.com.
This warranty does not cover normal wear and tear or apply
to a product that has:
been subject to misuse, neglect, negligence, damage or
accident
been used, operated or maintained other than in
accordance with Daveys instructions
not been installed in accordance with the Installation
Instructions or by suitably qualied personnel
• been modied or altered from original specications or
in any way not approved by Davey
had repairs attempted or made by other than Davey or
its authorised dealers
been subject to abnormal conditions such as incorrect
voltage supply, lightning or high voltage spikes, or
damages from electrolytic action, cavitation, sand,
corrosive, saline or abrasive liquids,
The Davey warranty does not cover replacement of
any product consumables or defects in products and
components that have been supplied to Davey by third
parties (however Davey will provide reasonable assistance to
obtain the benet of any third-party warranty).
To make a warranty claim:
If the product is suspected of being defective, stop
using it and contact the original place of purchase.
Alternatively, phone Davey Customer Service or send a
letter to Davey as per the contact details below
Provide evidence or proof of date of original purchase
If requested, return the product and/or provide further
information with respect to the claim. Returning the
product to the place of purchase is at your cost and is
your responsibility.
The warranty claim will be assessed by Davey on the
basis of their product knowledge and reasonable
judgement and will be accepted if:
o a relevant defect is found
o the warranty claim is made during the relevant
warranty period; and
o none of the excluded conditions listed above apply
• The customer will be notied of the warranty decision
in writing and if found to be invalid the customer must
organise collection of the product at their expense or
authorise its disposal.
If the claim is found to be valid Davey will, at its option, repair
or replace the product free of charge.
The Davey warranty is in addition to rights provided by
local consumer law. You are entitled to a replacement or
refund for a major failure and compensation for any other
reasonably foreseeable loss or damage. You are also entitled
to have the goods repaired or replaced if the goods fail to be
of acceptable quality and the failure does not amount to a
major failure.
For any internet connected products the consumer is
responsible for ensuring a stable internet connection. In
the event of a network failure the consumer will need to
address the concern with the service provider. Use of an App
is not a substitute for the User’s own vigilance in ensuring
the product is working to expectation. Use of a Smart
Product App is at the User’s own risk. To the fullest extent
permitted by law Davey disclaims any warranties regarding
the accuracy, completeness or reliability of App data. Davey
is not responsible for any direct or indirect loss, damage
or costs to the User arising from its reliance on internet
connectivity. The User indemnies Davey against any claims
or legal actions from them or others relying on internet
connectivity or App data may bring in this regard.
Products presented for repair may be replaced by
refurbished products of the same type rather than being
repaired. Refurbished parts may be used to repair the
products. The repair of your products may result in the loss
of any user-generated data. Please ensure that you have
made a copy of any data saved on your products.
To the fullest extent permitted by law or statute, Davey shall
not be liable for any loss of prots or any consequential,
indirect or special loss, damage or injury of any kind
whatsoever arising directly or indirectly from Davey
products. This limitation does not apply to any liability of
Davey for failure to comply with a consumer guarantee
applicable to your Davey product under local laws and does
not aect any rights or remedies that may be available to
you under local laws.
For a complete list of Davey Dealers visit our website
(daveywater.com) or call:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Davey 62101 Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI