Figure 1 - Locating Vent Pipe
Figure 2 - Adjusting the Height of the Termination
INSTALLATION INSTRUCTIONS FOR MODEL RF-58 FLAT ROOF FLASHING
FOR USE WITH 5/8'' DIRECT VENT PIPE
VENT PIPE
ROOF
FLASHING
STORM COLLAR
MODEL SC-58
VERTICAL
TERMINATION
MODEL VT-58
Must be 24" (610 mm)
Minimum Distance from
Top of Wall to Vent Intake
If less than 10’
(3.1 Meters) Distance
to Wall or Parapet
VENT PIPE
FIRESTOP
MODEL FP-58
ROOFING
NAILS
12" (305 mm)
Minimum Distance
above Roof Line
10’ (3.1 Meters)
Minimum Distance
to Wall or Parapet
10 "
3
/
4
(273 mm)
Cutout
Size
10 "
3
/
4
(273 mm)
Cutout
Size
Vent components must be installed by a qualied service
agency in accordance with these instructions and the
product installation guide.
These instructions are included as part of the appliance installation
instructions. Read the entire product installation guides completely
before installing this roof ashing.
CAUTION: When mounting this venting component do
not modify or substitute any parts provided. Do not deform
or penetrate the inner gas vent pipe when mounting.
Parts included with this kit:
Part No. Description Qty.
108074-01
118071-01
Tools Required:
• Roof Nails or Staples
• RTV Silicone Sealant Grey/Black
• Rubberized Mastic or Flashing Compound
• Tape Ruler or Ruled Level
• Plumb Line and Cut Marker
• Hammer or Nail Gun
• Saws-All or Recipricating Saw
• Framing or Bracing Material (Construction Grade)
FLASHING INSTALLATION
1. Plumb and locate the knockout area for the vent pipe follow the
product installation manual and all local codes for proper vent
location and height.
2. If this is a retro-installation, remove any roof rock or other materi-
als down to the underlayment away to at least 15 inches from
the center of the vent pipe location.
Note: If this is a non-combustible roof (i.e. corregated metal or
sheet rock) a restop at roof grade may not be required. However a
1 inch clearance to combustible wood framing and insulation must
be maintained.
3. Cut a 10-3/4'' X 10-3/4'' square knockout and frame the restop
to the dimensions shown in Figure 1. (8-1/2'' round hole, when
installing through a non-combustible roof).
4. Install the vent pipe through the restop or roof opening to the
required height.
5. Loose t the ashing assembly assembly with storm collar and
termination to ensure proper height. See Figure 2.
1
1
Instruction Sheet
Roof Flashing Assembly