Moen 900-006 Specification

Type
Specification

This manual is also suitable for

Specifications
DESCRIPTION
· Smart home water monitoring and leak detection system
OPERATION
· Remote, automatic, and manual water on/o (shut-o ) capability
· WiFi enabled device for smartphone connectivity
· Smartphone app available for iOS and Android that provides the following:
•Proactive maintenance alerts (i.e. leak alert, pressure alerts, etc.)
•Remote water control and shut-o
•Set water consumption goals and monitor water usage
•Set system modes (home, away, sleep)
•See real-time  ow, pressure, and temperature readings
•Run manual leak detection tests “Health Tests”
· Works with Amazon Alexa, Google Assistant, IFTTT and Control4
FLOW
· Maximum operating pressure of 175 psi
STANDARDS
· Third party certi ed to standard IAPMO IGC 349 and all applicable standards listed therein
· Third party certi ed to standards UL1951, CSA C22.2 no. 14 and no. 68 and all applicable standards listed therein
· Third party certi ed to standards NSF 61/9 and NSF 372 and all applicable standards listed therein
· Conformant to FCC part 15 Class C
· Conformant to Innovation, Science and Economic Development Canada (ISED) RSS-247
WARRANTY
· Flo Technologies warrants that the product will be free from defects in materials and workmanship for a
period of one (1) year from the date of delivery following the original retail purchase
· Extended product warranty available through FloProtect plan
Visit www.support.meet o.com for complete details and limitations
Installation Notes:
· Install product following the installation guide
· Must be installed on accessible main water supply line (cold water line) that is 0.75 inch diameter
(can be installed on 1.25 inch diameter or smaller)
· Must be installed after water meter, water shut-o , and pressure regulating valve (if applicable)
· Power supply and device must not be installed where the ambient temperature can exceed
140 deg F (60 deg C) or below 32 deg F (0 deg C)
· Requires electrical outlet (100-240VAC-50/60 Hz) with continuous power within 6 feet of device
· Requires WiFI network (WLAN connectivity/IEEE 802.11bgn, 2.4 GHz range)
· Smartphone (iPhone or Android) with installed app required
For Well Pump System Installations:
· When installed on well or irrigation water service lines, the device should be placed after (downstream)
of all treatment and  ltration components to avoid debris interference. It should also be installed after
the well pump and water storage tank. If it is necessary to install the device prior to a water  ltration
system, a wye strainer with a 100 mesh or  ner screen and blow-down port is required to catch any
sediment or particles from the ground source or casing. The mesh screen in the strainer may require
periodic maintenance.
Flo by Moen™
Smart Home Water Monitoring
and Leak Detection System
Model: 900-001
FOR MORE INFORMATION CALL: 1-800-BUY-MOEN
www.moen.com
CRITICAL DIMENSIONS
(DO NOT SCALE)
Rev. 12/20
Included with product: 3/4" inch-NPT threaded brass tailpieces (x2),
AC adapter (12 VDC, 100-240VAC-50/60 Hz) with 10' cable (x1),
spare o-rings (x2), installation spacer (x1), 5/16" hex key (x1)
10' AC Adapter
(included)
Power
Input
Water
Flow
Direction
Backup
Shuto
Installation Spacer (included)
SECTION B-B
SCALE 1 : 1
SECTION C-C
SCALE 1 : 1
B B
C
C
DRAWN BY
JAS
APPROVED
HH
3/11/2019
3/11/2019
SIZE SCALE
DWG NO
430-00023
REV
SHEET
1
OF
1
DATE
FLOTECHNOLOGIES, INC.
TITLE
UNION TAILPIECE - NPT
A
B
MATERIAL
LF BRASS - GB HSi75-3
FINISH / POST-TREATMENT
PROPRIETARY AND CONFIDENTIAL
The information contained in this document is the sole property of
Flo Technologies, Inc. Any reproduction or redistribution without
the written permission of Flo Technologies is prohibited.
UNLESS NOTED OTHERWISE
1. ALL DIMENSIONS ARE IN mm
2. DEFAULT TOLERANCING:
BASIC VALUE TOLERANCE
X±0.50
.X ±0.25
.XX ±0.13
ANGLES: ±1/2°
SURFACE FINISH: 1.6 μm Ra
CONCENTRICITY: .25 mm TIR
DATE
1 : 1
30.5
26.9
32.28
32.03
Ø
16.3
2.4
3.5
3/4 - 14 NPT
L1, L3 GAUGING COMPLIANCE REQUIRED
30.5
R.38
NOTES:
1. WETTED COMPONENT - NSF 61 SECTION 8 APPLICATION.
SUBSTITUTION OF SUPPLIER, ALLOY OR PROCESS PROHIBITED WITHOUT FLO ENGINEERING OFFICIAL APPROVAL.
2. MANUFACTURING PROCESS:
MACHINED FORGING. DO NOT DIRECTLY MACHINE FROM EXTRUDED OR CONTINUOUS CAST ROD BLANKS.
THIS IS IMPORTANT TO ACHIEVE UNIFORM GRAIN STRUCTURE FOR BEST MECHANICAL PROPERTIES.
3. CERTIFICATION OF CORROSION RESISTIANCE:
FINISHED COMPONENT SHALL MEET TYPE 2 DR CLASSIFICATION CRITERIA WHEN TESTED PER AUSTRALIAN STANDARD AS 2345.
FINISHED COMPONENT SHALL NOT SHOW FORMATION OF STRESS CRACKS WHEN TESTED PER ASTM B858 WHEN TESTED WITH ASTM B16.22
COMPLIANT, UNS C12200 ALLOY PIPE PLUGS INSTALLED. PLUG SHALL HAVE 1 TO 2 WRAPS OF TEFLON SEALING TAPE. PLUG SHALL BE
INSTALLED TWO FULL TURNS PAST HAND TIGHT.
4. PART MUST BE CLEAN AND FREE OF OIL.
5. UNLESS SPECIFIED OTHERWISE, BREAK ALL CORNERS. NO BURRS PERMISSIBLE.
6. ROD CHEMICAL COMPOSITION:
35.03
34.83 32.28
32.00
(
)
REVISION HISTORY
REV DESCRIPTION BY DATE APPROVED
ANEW PART ISSUE JAS 3/11/2019 HH
Chemical Composition (%)
Alloy Cd Cu* Fe Mn Ni** PPb Si Sn Zn
HSi75-3 0.01 max 73.0-77.0 0.10 max .10 max .10 max .04 - .15 .10 max 2.7 - 3.4 .20 max remainder
* Cu value includes Ag. Cu + Sum of Named Elements 99.5% minimum
** Ni value includes Co
45°
45°
45°
TYP
32.28
32.00
R5
Tailpieces (Included)
SECTION B-B
SCALE 1 : 1
SECTION C-C
SCALE 1 : 1
B B
C
C
DRAWN BY
JAS
APPROVED
HH
3/11/2019
3/11/2019
SIZE SCALE
DWG NO
430-00023
REV
SHEET
1
OF
1
DATE
FLOTECHNOLOGIES, INC.
TITLE
UNION TAILPIECE - NPT
A
B
MATERIAL
LF BRASS - GB HSi75-3
FINISH / POST-TREATMENT
PROPRIETARY AND CONFIDENTIAL
The information contained in this document is the sole property of
Flo Technologies, Inc. Any reproduction or redistribution without
the written permission of Flo Technologies is prohibited.
UNLESS NOTED OTHERWISE
1. ALL DIMENSIONS ARE IN mm
2. DEFAULT TOLERANCING:
BASIC VALUE TOLERANCE
X±0.50
.X ±0.25
.XX ±0.13
ANGLES: ±1/2°
SURFACE FINISH: 1.6 μm Ra
CONCENTRICITY: .25 mm TIR
DATE
1 : 1
30.5
26.9
32.28
32.03
Ø
16.3
2.4
3.5
3/4 - 14 NPT
L1, L3 GAUGING COMPLIANCE REQUIRED
30.5
R.38
NOTES:
1. WETTED COMPONENT - NSF 61 SECTION 8 APPLICATION.
SUBSTITUTION OF SUPPLIER, ALLOY OR PROCESS PROHIBITED WITHOUT FLO ENGINEERING OFFICIAL APPROVAL.
2. MANUFACTURING PROCESS:
MACHINED FORGING. DO NOT DIRECTLY MACHINE FROM EXTRUDED OR CONTINUOUS CAST ROD BLANKS.
THIS IS IMPORTANT TO ACHIEVE UNIFORM GRAIN STRUCTURE FOR BEST MECHANICAL PROPERTIES.
3. CERTIFICATION OF CORROSION RESISTIANCE:
FINISHED COMPONENT SHALL MEET TYPE 2 DR CLASSIFICATION CRITERIA WHEN TESTED PER AUSTRALIAN STANDARD AS 2345.
FINISHED COMPONENT SHALL NOT SHOW FORMATION OF STRESS CRACKS WHEN TESTED PER ASTM B858 WHEN TESTED WITH ASTM B16.22
COMPLIANT, UNS C12200 ALLOY PIPE PLUGS INSTALLED. PLUG SHALL HAVE 1 TO 2 WRAPS OF TEFLON SEALING TAPE. PLUG SHALL BE
INSTALLED TWO FULL TURNS PAST HAND TIGHT.
4. PART MUST BE CLEAN AND FREE OF OIL.
5. UNLESS SPECIFIED OTHERWISE, BREAK ALL CORNERS. NO BURRS PERMISSIBLE.
6. ROD CHEMICAL COMPOSITION:
35.03
34.83 32.28
32.00
(
)
REVISION HISTORY
REV DESCRIPTION BY DATE APPROVED
ANEW PART ISSUE JAS 3/11/2019 HH
Chemical Composition (%)
Alloy Cd Cu* Fe Mn Ni** PPb Si Sn Zn
HSi75-3 0.01 max 73.0-77.0 0.10 max .10 max .10 max .04 - .15 .10 max 2.7 - 3.4 .20 max remainder
* Cu value includes Ag. Cu + Sum of Named Elements 99.5% minimum
** Ni value includes Co
45°
45°
45°
TYP
32.28
32.00
R5
0.75 in
NPT
  • Page 1 1

Moen 900-006 Specification

Type
Specification
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI