Emerald 61059 Selectis User manual

Type
User manual

Emerald 61059 Selectis is a versatile alternating pressure pump and mattress system designed to manage pressure ulcers, enhance patient comfort, and assist in pain management under medical supervision. Its key features include:

  • Pressure Relief: Alternating pressure mode ensures regular pressure redistribution, reducing the risk of pressure sores.

  • Static Mode: Provides continuous, static pressure for added stability and support.

  • Max Firm Mode: Quickly inflates the mattress to maximum firmness, facilitating nursing and caregiving procedures.

  • Seat Inflate Mode: Inflates specific sections of the mattress for comfortable seating positions.

Emerald 61059 Selectis is a versatile alternating pressure pump and mattress system designed to manage pressure ulcers, enhance patient comfort, and assist in pain management under medical supervision. Its key features include:

  • Pressure Relief: Alternating pressure mode ensures regular pressure redistribution, reducing the risk of pressure sores.

  • Static Mode: Provides continuous, static pressure for added stability and support.

  • Max Firm Mode: Quickly inflates the mattress to maximum firmness, facilitating nursing and caregiving procedures.

  • Seat Inflate Mode: Inflates specific sections of the mattress for comfortable seating positions.

www.emeraldsupply.net
SELECTIS ALTERNATING PRESSURE PUMP AND MATTRESS
USER MANUAL

Tel: (888) 363-5563
Email:info@emeraldsupply.net
Model 61059
Important Safeguards
1
Pump
The funcons of the Serenty Elite pump are described below. Please refer to the
below gures.
Power Switch(1)
The switch is at the right side of the pump.
Turn ON/OFF the power and press Power buton on the panel,the pump will
start/stop operaton.
Press Cycle Time(2)
The cycle me is selectable from the panel.
The cycle me value can be either 10, 15, 20, or 25 minutes.
Press Pressure Range(3)
20mmHg~55mmHg is oered from the panel, providing op ns of pressure
value by easy press.
Alarm Mute (4)
The audible/visible alarm turns on aer 1 minute when low pressure,power
failure or alternate failure.
To mute the audible alarm, press the Alarm Mute buton. The visible alarm
indicator will ash l problem solved.
Re-press the Alarm Mute buton to reac ate the alarm.
Alternate mode(5)
Press to set the air matress in alternate mode.
Statc mode(6)
Press to set the air matress in statc mode.
Max Firm(7)
Press to set the air matress in quick inaaon mode, which facilitates nursing
and caring.
Seat Inate (8)
Press to set the air matress in seat inate+ alternate or seat inate+statc
mode, pressure value will increase by 5mmHg, which facilitates sea g.
Under max rm mode, because the pressure is already set at the largest
value, no more 5mmHg will be increased.
Lock buton (9)
The panel will automacaly lock in 5 minutes without opera n.
Press the lock buton and hold for 3 seconds,to lock or unlock the panel.
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
5 6 7 8
9
Matress
Elite
Intended Use
The Selecs Serenity Elite pump and maress are intended to reduce the incidence of
pressure ulcers while opmizing paent comfort. It also provides the following:
Individual home care seng and long-term care
Pain management as prescribed by a physician
Product Funcons
4 5
Place pump on horizontal surface or hang it by means of the hook.
Open maess on the bed. Secure it with end aps or straps.
Connect air feed tubes to air outlet on the maess and pump, ensuring that the
tubes are notkinkedor twisted. Allow space for bed rails to drop freely.
Turn on the power. Aer a beep sound, the pump will begin the operaton.
The pump will enter statc mode initally when the power is turned on. The cycle
me is set at the 1st LED (10 min.), and the pressure level is set at the 3rd LED
(30±2mmHg).First it will inate the maess to 10-15±
2 mmHg and then enter
alternate mode.
During normal opera n, the pump will monitor pressure changes. If the pressure
is below a user-dened pressure level, the pump will automacaly start to inate
the maess.The pump will stop when the user-dened pressure level is reached.
The rst inlaon of new maess: the alarm func n (visible and audible alarm)
will actvate if matress is not inated completely within 40 minutes.
During pump is running, low pressure alarm will actvate within 1 minute aer air
tubes are disconnected or air cells are broken.
If there should be power failure,for example caused by power cord unplugged or
power owhen pump is working,the audible alarm will be actvated and power
failure indicator will ash.When power is back,pump will automatcally start
working.
If the matress stops alternatng or alternate abnormally,the audible alarm will be
actvated and alternate failure indicator will ash.
For nursing and caring convenience,press the max firm buon to automacaly
inate the maesses to the maximum level (55mmHg) for about 20 minutes. The
pressure will return to alternate mode aer 20 minutes.
Installaon & Operang Instrucons Environment Requirements
·Operaton Temperature: 50~95(10~35)
·Storage Temperature: 5~122(-15~50)
·Operaton Humidity: 20%~80% non-condensing
·Storage Humidity: 10%~90% non-condensing
Cleaning Guidelines
·Can be cleaned by disinfectant soluon
·Do not immerse the pump in water
·Do not heat or steam in autoclave
·The matress and cover are aerated unl they are fully dry
Maintenance
General
Check the power cord and plug to see if there are abrasions or excessive wear.
Check the maress cover for signs of wear or damage. Ensure the maress cover and tubes
are connected together correctly.
Plug in the pump unit and check the airow from the hose connecon port. The airflow should
alternate between ports every half-cycle me.
Check the air hoses to see if there are any kinks or breaks. For replacement, please contact
your local agent or dealer.
Make sure the maress tube is well connected.
Check the pump unit and make sure both power indicators are o when the switch is turned
off.
Low pressure
Examine if there is any air leakage between the pump and the maress connecons or from the air
maress tubes:
Check connectors between the air maress and pump. If there is any disconnecon, please
reconnect it.
Check the CPR Valves. Ensure their outlets are sealed.
Check the air-connecng tubes. Ensure each single cell is not broken.
Set the pressure at Max firm.Keep the tubes fully inflated and inspect for air leakage.
Check if there is any air leakage from cells. Ensure no leakage occurs. If any leakage occurs,
please contact your local agent or dealer.
·
·
·
·
·
·
·
·
·
·
·
Matress
Item: Seren Elite- 61059
Size:80"(L) x 36" (W) x8"(H)
Top cover: Quilted bi-elastc cover with
zipper
Air cells:Nylon PVC
(8 cell on cell constructon with 5 upper
layer alternatng and 3 lower layer statc)
Base: Nylon /PVC 840D
20 air cells
CPR valve for emergency procedures
Transport functon
Quick connectors
Pillow on
Pump
Item: Serenity Elite
Power supply: 120V 60Hz 1A
Air output: 8 litermin.
Pressure range: 20 mmHg 55 mmHg
Cycle 10/15/20/25 min.
Max rm mode
Alarm:Low pressure/Power failure/
Alternate failure
Alternate/Statc /Seat inate mode
Size:31cm(L) x 12.5cm(W) x 21cm(H)
Weight: 2.5 kg
Technical Specic
6 7
""
"
-
/
/,
Tel: (888) 363-5563
Email: info@emeraldsupply.net
www.emeraldsupply.net
2
2
s
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Emerald 61059 Selectis User manual

Type
User manual

Emerald 61059 Selectis is a versatile alternating pressure pump and mattress system designed to manage pressure ulcers, enhance patient comfort, and assist in pain management under medical supervision. Its key features include:

  • Pressure Relief: Alternating pressure mode ensures regular pressure redistribution, reducing the risk of pressure sores.

  • Static Mode: Provides continuous, static pressure for added stability and support.

  • Max Firm Mode: Quickly inflates the mattress to maximum firmness, facilitating nursing and caregiving procedures.

  • Seat Inflate Mode: Inflates specific sections of the mattress for comfortable seating positions.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI