HOW TO POSITION AND PROGRAM THE FLASH PROGRAMMER 2S
PRODUCT FUNCTIONS
Centralised programming for two heating zones
using two temperature modes:
- Comfort temperature
- Reduced temperature
Manual override function in comfort and reduced mode for each room.
PRINCIPLE OF OPERATION
Convectors equipped with a suitable electromechanical thermostat:
Reduced temperature obtained by supplying a resistance, which overrides the sensing element of the
thermostat.
Convectors equipped with a suitable electronic thermostat:
Reduced temperature achieved by delivering an alternating signal (coding adopted by all designers since
January 1994)
TECHNICAL CHARACTERISTICS
Time switch: Electronic clock with day and week programs.
Power backup: By lithium battery, backup guarantee for a total of 3 years minimum against mains failure
(battery life: 10 years)
Program increments: 1 minute
Number of zones: 2
Total maximum current rating: 0.5A
Dimensions: 167mm x 84mm x 44mm
INSTALLATION
1 Unscrew the time switch fixing
screw
2 Separate the base plate from
the casing using a screwdriver
3 Surface-Mounted base with 2off
screw fixings Ø3mm maximum
4 Electrical connections (see page 2)
IMPORTANT Insert the flying
lead from the display panel into the
socket on the circuit board as shown
5 Put outer casing back on
6 Put back in and tighten the
time switch fixing screw
1
CONNECTING THE PILOT WIRE
Whether mechanical or electronic, regardless of make, since January 1997, the reduced mode of a thermostat
which can be programmed via pilot wire, is achieved by transmission of an alternation signal via the pilot wire
ELECTRICAL CONNECTIONS
FOR PILOT WIRE CONVECTOR HEATERS
1. All types of convectors since 1994:
The pilot wire carries the live current to the convector Inputs: connect neutral to L1 and “Live” to L2
2. Convectors before January 1994:
Check the convector instructions or if you have none, consult the manufacturer. In certain cases, the pilot
wire carries the neutral current to the convector inputs. In this event, connect neutral to L2 and “Live” to L1.
2
USER GUIDE
HOW TO PROGRAM AND USE THE FLASH PROGRAMMER 2S
WHY A PROGRAMMER
FOR GREATER CONTROL OF YOUR COMFORT:
- The temperature you need at a time that suits you.
FOR GREATER CONTROL OVER YOUR ENERGY COSTS:
- Slightly lowering the temperature during the night or when you are not at home can achieve
substantial savings.
PRINCIPLE OF OPERATION
FLASH PROGRAMMER 2S ALLOWS YOU TO PROGRAM TWO HEATING ZONES
Example:
- Day zone for the dining room, living room etc
- Night zone for the bedroom etc
THE TIMES YOU PROGRAM FOR EACH ZONE DEFINE THE COMFORT HEATING TIMES AND THE
REDUCED HEATING TIMES
Comfort Temperature
: The temperature you want in the house when you are at home, which can be set
Individually for each room.
Reduced Temperature : The temperature you want in the house when you are away or at night
MANUAL OPERATION FOR EACH INDIVIDUAL ZONE 1 AND 2
PROGRAMMING
The dual zone time switch allows you to program 20 comfort or reduced switching times spread anywhere over
the two zones.
e.g. 12 switching times for zone 1 and 8 for zone 2.
Each switching time can be applied to one or several days of the week.
e.g. comfort mode from Monday to Friday at 7.00 represents one switching time. You now have 19 left.
3
4
BEFORE PROGRAMMING YOUR FLASH PROGRAMMER 2S
TAKE TIME TO WRITE YOUR PROGRAM IN THE TABLES BELOW
ZONE 1 (The first lines are filled with an example)
ZONE 1 C1 Times Mon 1 Tue 2 Wed 3 Thu 4 Fri 5 Sat 6 Sun 7
Comfort
Example
07:00
Reduced
Example
08:00
Comfort :
Reduced :
Comfort :
Reduced :
Comfort :
Reduced :
Comfort :
Reduced :
Comfort :
Reduced :
ZONE 2 (The first lines are filled with an example)
ZONE 2 C2 Times Mon 1 Tue 2 Wed 3 Thu 4 Fri 5 Sat 6 Sun 7
Comfort
Example
20:00
Reduced
Example
23:00
Comfort :
Reduced :
Comfort :
Reduced :
Comfort :
Reduced :
Comfort :
Reduced :
Comfort :
Reduced :
1. SETTING THE TIME
2. PROGRAMMING
5
3. AUTO MODE
4. CHECKING SWITCHING TIMES
6
5. MODIFYING OR CANCELLING SWITCHING TIMES
7
6. PERMANENTLY OVERRIDING “TIMER” MODE
7. TEMPORARILY OVERRIDING “TIMER” MODE (HOLIDAYS etc)
APPLIED ENERGY PRODUCTS LIMITED
MORLEY WAY, PETERBOROUGH PE2 9JJ
TEL +44 (0) 01733 456789 / FAX: +44 (0) 01733 310606
Website: www.creda-heating.co.uk
(Leaflet No. 22671AA Revision. A)
8
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

FLASH Flash 2S Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI