English
7 EN
TECHNICAL PROG.
KEY MENU
Self. learning
CONFIGURATION
TESTING
5. Self. learning - Clone
CONFIGURATION
Bolierpress. 1.3bar
LowpowerNO
Sensitivity level 2
MEASURING UNIT
Drying 05.0s
Boiler pressure -indicatesthepressureoftheboiler;0.6to1.6bar
(9to23psi)
Low power - YES/NO
Sensitivity level - indicatesthedegreeofsensitivityofthelevelprobe,
which then operates the lling of the boiler with water. For safety
reasons, automatic level control of the boiler is disabled when the
boilerresistanceisturnedoff.
-Note:setavalueof1ifthemachineisinstalledwithveryconductive
water.
-Note:setavalueof3ifthewaterusedisnotveryconductive(verysoft).
MEASURING UNIT–includes2sub-menus
Temperature–canbesetto°CCelsiuscentigradeor°FFahrenheit
degrees.
Pressure–canbesettobarorpsi.
Drying - wafer dryingtime from0 to5 withsteps of0.1 seconds“if
Dryingkitispresent”.
Time check - viewdispensingtimeonthedisplay:YES/NO
Buzzer-enables/disablesallaudiblesignalswhenkeysarepressedor
messagesaredisplayed:YES/NO.
Customer programming - customerprogramming:YES/NO
Block programming - blockprogramming:YES/NO.Whenthisfunction
is activated (YES), the programming keypad can only be used by
accessingthetechnicalmenu
Stop dispensing: enabled - YES/NO.
YES:eachdispensingkeyperformsstart/stop.
Thismeansthatpressingthesamebuttonduringdispensinginterruptsit
Payment system – permits conguration of payment system, when
connected.
WASHING OPTIONS - See paragraph “Washing options” on the
followingpages.
RESIN regeneration - includestheresinregenerationsettings:litres
ofresin(from0.1lto25l),hardness(from0to45°F).
CONFIGURATION
Paym. system NO
WASHING OPTIONS
Resin regeneration
MAINTENANCE
DATA IN/OUT
CONFIGURATION
Time check NO
buzzerSI
Custumerprog. SI
progr.block NO
DispensingStop NO
6. Conguration menu
Press the key .
Placethecuporcupsunderneaththelter-holdernozzlesandpressthe
keytobeprogrammed,holdinguntil
thedesiredlevelisreachedinthecuporcups.
Duringthisphase,thevalueoftheimpulsesofthevolumetricdosingdevice
(toprightonthedisplay)isincreased;whenthekeyisreleased,
thevaluereachedisstoredandappearsonthedisplay.
Thisfunction allows coffeedose settingsof the right groupto be
copiedtoallothergroups.
CLONE FUNCTION
Attheendoftheprocess,allthegroupswillhavethesamesettings.
Onceprogrammingoftherightgroupiscomplete,pushOK.