V-ZUG 002 Installation guide

Category
Cookers
Type
Installation guide

This manual is also suitable for

Installation instructions
Induction glass ceramic hob
With normal mounting frame
J488.113-2
20.1.09 ITH
1
These installation instructions apply to the models: 488 (GK46TIC), 489 (GK46TIVC), 002 (GK46TIASC)
Identification plate
The identification plate is next to the connection plate.
A Affix the second identification plate (enclosed) in an accessible position behind the front
of the fitted cabinet beneath the appliance.
A Information on the necessary mains voltage, type of current and fuse protection is to be obtained from the identification plate.
A The appliance is equipped with a mains cable that should be connected to a distribution box by the customer.
A If an oven is installed beneath the appliance, we recommend placing the distribution box behind the base. A cut-out can be made
in the rear wall for the cables.
Error message U400
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order
specified.
Validity
General notes
If fitting in flammable material, the guidelines and standards for low voltage installations and for the fire protection must be strict-
ly observed.
Accessories
Designation Article no.
Ventilation protective plate set
For niche width 550–600 mm
For niche width 825–900 mm
H6.2122
H6.2123
Electrical connections
Electrical connections must be carried out by trained electricians in accordance with the guidelines and standards for low volt-
age installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. A
mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and socket
devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching are per-
missible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and fault-
free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should al-
ways be checked.
Incorrect connection:
A pole conductor was connected to the connecting terminal for neutral conductors.
Quickly disconnect the appliance from the mains!
Connection plate
Identification plate
600/550
900
Installation pipe
Distribution box
Clamp
400 V 2N~
230 V~
AUS / NZ
PE/ green/yellow
N blue
L1 brown
L2 black
PE/ green/yellow
N blue
L1 brown
Installation instructions
Induction glass ceramic hob
With normal mounting frame
J488.113-2
20.1.09 ITH
2
Indications
The work surface has to be flat to ensure that the appliance is adequately sealed against liquids.
In order to guarantee good ventilation, there needs to be a space of at least 2 cm height beneath the appliance.
If the depth of the work surface is 30 mm, you can place an oven with 762 mm height directly underneath the appliance, exception:
M-SL[P].
It is to possible install an oven in the short mounting forms 55-600, 60-600, 55-381 or 60-381 beneath the appliance if you use a
ventilation grille set (oven accessories).
Installing
1. Cut out mounting cut-out precisely.
2. Carefully place the appliance in the mounting cut-out and press against the work surface with sufficient overlap.
Cool air supply if installed over a drawer or cabinet
In order to guarantee good ventilation, there needs to be a space of at least 2 cm height beneath the appliance.
With a protective plate beneath the ventilator
If necessary, a protective plate (see «Accessories») can be fitted above the drawer.
Installation
The layout of the cooking zones on the integrated hob may differ from the illustrated hob!
GK46TIC GK46TIVC, GK46TIASC
514
774
750 ±1
514
584
560 ±1
min. 30
min. 30
600/550
900
600
600
600/550
900
min. 50
490 ±1
min. 50
490 ±1
52.6
from level
For symmetrical fitting,
it is not necessary to
cut out the side walls.
aim for
max. R10
aim for
max. R10
52.6
from level
min. 5
max. 75
==
min. 15
min. 55
min. 70
min. 30
600/550
==
min. 240 min. 245
Drawer Centre of fan
Air gap over the entire cabinet element width
min. 25 cm²
Necessary space for the ventilation
below the worktop required
min. 5
==
~10
min. 70
52.6
15
Middle of angle
Drawer
Centre of fan
(17.4)
Warning:
Do not place mains cable in the
area of the protective plate
Air gap over the entire cabinet element width
min. 25 cm²
  • Page 1 1
  • Page 2 2

V-ZUG 002 Installation guide

Category
Cookers
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI