V-ZUG 68A Installation guide

Category
Kitchen & houseware accessories
Type
Installation guide

V-ZUG 68A combi-steam cooker offers a range of features for preparing delicious meals. With its steam function, you can gently cook vegetables, fish, and meat while preserving their nutrients and flavors. The hot air mode allows you to roast and bake dishes, while the combination of steam and hot air ensures crispy results. The appliance also features various automatic programs for easy and convenient cooking.

V-ZUG 68A combi-steam cooker offers a range of features for preparing delicious meals. With its steam function, you can gently cook vegetables, fish, and meat while preserving their nutrients and flavors. The hot air mode allows you to roast and bake dishes, while the combination of steam and hot air ensures crispy results. The appliance also features various automatic programs for easy and convenient cooking.

Installation instructions
Combi-steam cooker with fixed water mains connection
Construction type 60-450
J68A.113-1
13.12.11 WIMA
1
These installation instructions apply to the model:
Identification plate
Open the appliance door. The type plate is located on the left-hand edge protector (see figure).
Connection plate
The connection plate is on the connection cable.
Refer to the identification plate for specifications for the required mains voltage, current type and fuses.
Application height of the appliance: up to max. 2000 m above sea level
Mains cable
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order
specified.
The unpacked appliance has sharp edges. It is advisable to wear gloves to reduce risk of injury.
Lift the appliance carefully out of the box. Only lift the appliance using the handles at the side, otherwise there is a risk that the
individual parts of the appliance will be crushed. The appliance must never be transported upside down.
Validity
Combi-steam cooker:
68A
General notes
If fitting in flammable material, the guidelines and standards for low voltage installations and for the fire protection must be
strictly observed.
Electrical connections
Electrical connections must made by trained electricians in accordance with the guidelines and standards for low voltage
installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should
always be checked.
230V~ 16A
400V2N~ 10A
L2 black
L1 brown
N blue
yellow/green
N blue
L1 brown + black
yellow/green
Installation instructions
Combi-steam cooker with fixed water mains connection
Construction type 60-450
J68A.113-1
13.12.11 WIMA
2
Dimension drawing
* or min. 555, depending on installation combination
Space requirement
Installation
=
=
50
346
(567)
454
596
548
~85˚
min. 575*
600
560–568
20
~45
548
X
450
Detail X
450
Niche
454
Appliance
min. 40
min. 40
min. 40
Installation instructions
Combi-steam cooker with fixed water mains connection
Construction type 60-450
J68A.113-1
13.12.11 WIMA
3
Installation combination
Installation
1. Check that the installation surface is absolutely level using the spirit level.
2. Place the appliance in front of the niche and connect the mains cable according to the connection plate.
3. Connect reinforced hose and drain hose to the appliance.
4. Guide the drain hose round the screw connection of the fixed mains water connection and connect up according to the drawing
below.
5. Slide the appliance into the niche carefully until it is flush with the front of the cabinets, making sure that the mains cable and hoses
do not get bent or caught up. Any bent hoses must be replaced. Pull the hoses continuously.
6. Open the appliance door and secure the appliance from the front at the sides with 4 enclosed screws.
7. Check the alignment of the appliance; the decoration should not touch.
8. Connect the customer's water connections and check for leaks.
For an installation depth of less than 575 mm, we recommend installing the appliance underneath other appliances for reasons
of space.
For installing with a second appliance in the same niche, use the bracket set 60 W.
Under the second appliance
Depth > 555
Above the second appliance
Depth > 575
Above the warming drawer
Depth > 555
X = height of second appliance
Y = niche height
The drain hose must go around the screw connection of the fixed mains water supply (see picture below).
W
X456
Y
50
min.40
W
450X
Y
50
min. 40
W
450X
Y
50
min. 40
Installation instructions
Combi-steam cooker with fixed water mains connection
Construction type 60-450
J68A.113-1
13.12.11 WIMA
4
Draining
Water connections
1 Hose clamp
2 Reinforced hose inlet
3 Drain hose
Customer installations:
4 Drain trap
5 Plinth
6 Hose in plinth
7 Cold water supply with stopcock
Drain hose length: 3 m
The drain hose must be laid flat and not have any twists.
The drain hose may not be extended or shortened.
The drop from the bottom of the appliance to the drain trap must be
at least 50 mm.
The hose clamp is fitted at a height of 700 mm (see figure “Water
connections”).
Connecting the drain
1. Install the hose clamp 1.
2. Remove the blind cap and non-return valve 2 on the drain trap.
3. Clean the drain trap.
4. Fit the drain hose in the hose clamp.
5. Lay the drain hose without any kinks.
6. Connect the drain hose to the drain trap.
1
4
2 73 56
min. 50
700
2
1
Installation instructions
Combi-steam cooker with fixed water mains connection
Construction type 60-450
J68A.113-1
13.12.11 WIMA
5
Cold water supply
Connecting the drain for the installed dishwasher
1. Install the hose clamp 1.
2. Remove the hose to the dishwasher on the drain trap.
3. Remove the adapter, blind cap and non-return valve 2.
4. Clean the drain trap.
5. Connect the Y-section 3 on the drain trap. Note: The Y-section is NOT
included in the delivery scope.
6. Connect the hose for the dishwasher to the Y-section.
7. Fit the drain hose in the hose clamp.
8. Lay the drain hose without any kinks.
9. Connect the drain hose to the Y-section.
Operating pressure: 0.1–1.0 MPa (1–10 bar)
Long reinforced hose: 2 m
The guidelines of the local water company must be observed.
Any existing hoses must be replaced.
The reinforced hose may not be extended.
The stopcock must be accessible once again after installation.
Connecting the water inlet
1. Clean the sealing surface on the stopcock.
2. Connect the reinforced hose to the stopcock and tighten with pipe pliers.
3. Check the seal.
Connecting the inlet for the installed dishwasher
1. Remove the hose to the dishwasher on the stopcock.
2. Clean the sealing surface on the stopcock.
3. Connect T-section 1. Note: The T-section is NOT included in the delivery
scope.
4. Connect the reinforced hose to the T-section and tighten with pipe pliers.
5. Connect the hose to the dishwasher on the T-section and tighten with pipe
pliers.
6. Check the seal.
3
2
1
1
Installation instructions
Combi-steam cooker with fixed water mains connection
Construction type 60-450
J68A.113-1
13.12.11 WIMA
6
1. Remove accessories from the cooking space.
2. Remove the sealing film over the water outlet in the cooking space.
3. Insert the filter over the water outlet in the cooking space.
- At the end of the process, the appliance releases the steam automatically, which should be checked. The base is then flooded with
water automatically and must be completely drained off until there are only a few drops left.
If the «Check water supply» message appears:
Check whether the water supply is open and water is available.
If the water supply is open, press OK on the display to confirm.
Check that the reinforced hose is free of kinks.
If water still remains in the cooking space, the pumping off process is repeated more than three times at short intervals, the “Check
water outlet” or E77, E78 message appears:
Check the drain hose is free of kinks.
Lay the drain hose so that the hose content does not run back into the appliance.
Checking installation and starting for the first time
4. Appliance with the steamer mode Operate at 100°C for at least 4 minutes.
Draining the water system prior to maintenance work or transport
Draining the water system occurs automatically approx. 20 minutes after it has finished operating and drains the water
system by approx. 90%.
The F27 message indicates an undrained water system.
The main parts of the water system cannot be drained without a power supply.
Special care is needed if the descaling was aborted and descaler still remains in the water system.
Draining the fixed mains water connection
Close the stopcock, hang up the reinforced hose.
Start the hot air mode, then press the Off button after 10 seconds. Wait one minute until it drains.
Disassembling and transport
For removing the device, pull out the hoses continuously from behind.
Avoid contamination from waste water in the reinforced hose.
The appliance must never be tilted more than 45°.
1
.
Sealing film
2.
3.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

V-ZUG 68A Installation guide

Category
Kitchen & houseware accessories
Type
Installation guide

V-ZUG 68A combi-steam cooker offers a range of features for preparing delicious meals. With its steam function, you can gently cook vegetables, fish, and meat while preserving their nutrients and flavors. The hot air mode allows you to roast and bake dishes, while the combination of steam and hot air ensures crispy results. The appliance also features various automatic programs for easy and convenient cooking.

Ask a question and I''ll find the answer in the document