Cisco UCS-CPU-E5-4650L= Datasheet

Category
Processors
Type
Datasheet

This manual is also suitable for

CISCO SYSTEMS PUBLICATION HISTORY
170 W
EST TASMAN DR.
S
AN JOSE, CA, 95134 REV A.13 MAY 27, 2013
WWW.CISCO.COM
Cisco UCS B420 M3
Blade Server
Cisco UCS B420 M3 Blade Server
2
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Blade Server Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 5
CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
STEP 1 VERIFY SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
STEP 2 CHOOSE CPU(S) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
STEP 3 CHOOSE MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
STEP 4 CHOOSE DISK DRIVES (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
STEP 5 CHOOSE ADAPTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
STEP 6 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . 19
STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS . . . . . . . . . . . . . . . . . . . . 20
STEP 8 ORDER INTERNAL USB 2.0 DRIVE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . 21
STEP 9 ORDER FLASH-BACKED WRITE CACHE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . 22
STEP 10 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . 23
STEP 11 CHOOSE OPERATING SYSTEM MEDIA KIT (OPTIONAL) . . . . . . . . . . . . . . . . . . . . 26
STEP 12 CHOOSE SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
STEP 13 CHOOSE LOCAL KVM I/O CABLE* (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . 32
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
System Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
DIMM and CPU Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
DIMM Population Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Network Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
VIC 1240 and Port Expander for VIC 1240 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Connectivity Using the Cisco UCS 2208XP Fabric Extender . . . . . . . . . . . . . . . . . . . . 43
Connectivity using the Cisco UCS 2204XP Fabric Extender . . . . . . . . . . . . . . . . . . . . 52
Connectivity using the Cisco UCS 2104XP Fabric Extender . . . . . . . . . . . . . . . . . . . . 61
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Cisco UCS B420 M3 Blade Server
OVERVIEW
3
OVERVIEW
Designed for enterprise performance and scalability, the Cisco® UCS B420 M3 Blade Server combines the
advantage of 4-socket computing with the cost-effective Intel® Xeon® processor E5-4600 product family,
for demanding virtualization and database workloads.
With industry-leading compute density, I/O bandwidth and me
mory footprint, the UCS B420 M3 is a
balanced, high-performance platform that complements the UCS blade server portfolio. The full-width UCS
B420 M3 supports 1.5 TB of memory and leverages UCS VIC technology for up to 160 Gb aggregate I/O
bandwidth.
The UCS B420 M3 is part of the Cisco Unified Computing System
(UCS) that combines blade and rack servers
with networking and storage access into a single unified system. Centrally configured through unified,
model-based management, Cisco UCS simplifies and speeds deployment of enterprise-class applications
running in bare-metal, virtualized and cloud-computing environments.
Figure 1 Cisco UCS B420 M3 Blade Server
Cisco UCS B420 M3 Blade Server
4
DETAILED VIEWS
DETAILED VIEWS
Blade Server Front View
Figure 2 is a detailed front view of the Cisco UCS B420 M3 Blade Server.
Figure 2 Blade Server Front View
1 Drive bay 1 8 Power button and LED
2 Drive bay 2 9 Network link status LED
3 Drive bay 3 10 Blade health LED
4 Drive bay 4 11
Console connector
1
Notes
1. For information about the KVM local I/O cable that plugs into the console connector (a cable is included with
every Cisco UCS 5100 Series blade server chassis accessory kit), see CHOOSE LOCAL KVM I/O CABLE*
(OPTIONAL) on page 32.
5 Blade ejector handle 12 Reset button access
6 Asset pull handle
(a blank asset tag is provided on which
you can add your own label or sticker or
you
can use a marker to write your asset
information on the tag)
13 Beaconing LED and button
7 Blade ejector handle - -







Cisco UCS B420 M3 Blade Server
BASE SERVER STANDARD CAPABILITIES and FEATURES
5
BASE SERVER STANDARD CAPABILITIES and FEATURES
Table 1 lists the capabilities and features of the base server. Details about how to configure the server for
a particular feature or capability (for e
xample, number of processors, disk drives, or amount of memory)
are provided in CONFIGURING the SERVER on page 7.
NOTE: The B420 M3 blade server requires UCS Manager 2.0 (4b) or later to operate
as part of the UCS system.
Table 1 Capabilities and Features
Capability/Feature Description
Blade server chassis The full-width UCS B420 M3 Blade Server mo
unts in a Cisco UCS 5100 series
blade server chassis
CPU Up to four Intel® E5-4600 series processor family CPUs.
2- and 4-CPU configurations are supported
on the UCS B420 M3.
Chi
pset Intel® C600 series chipset
Memory 48 total slots for registered ECC DIMMs
I/O 3 configurable adapter slots:
One slot supports the Cisco VIC 1240 adapter only.
Two slots support Cisco adapters, Emulex and QLogic adapters, and Cisco
UCS Storage Accelerator adapters.
Storage controller Integrated LSI Logic SAS 2208R controller
SAS/SATA/SSD support
RAID 0, 1, 5, 10
Optional 1 GB flash-backed write cache
Internal storage devices Four hot-plug 2.5” SFF drive bays
One internal USB 2.0 port
Two Cisco Flexible Flash secure digital card slots (future support)
Video The Cisco Integrated Management Co
nt
roller (CIMC) provides video:
Matrox G200e video controller
Integrated 2D graphics core with hardware acceleration
Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at
60 Hz
24-bit color depth for all resolutions less than 1600x1200
Up to 256 MB video memory
Cisco UCS B420 M3 Blade Server
6
BASE SERVER STANDARD CAPABILITIES and FEATURES
Interfaces Front panel
One console connector
(see CHOOSE LOCAL KVM I/O CABLE* (OPTIONAL) on page 32)
Power subsystem Integrated in the Cisco UCS 5100 series blade server c
hassis
Fans Integrated in the Cisco UCS 5100 series blade server c
hassis
Integrated management
proces
sor
The built-in Cisco Integrated Management Controller (CIMC) GUI or CLI
interface enables you to monitor the server inventory, health, and system
event logs.
Table 1 Capabilities and Features (continued)
Capability/Feature Description
Cisco UCS B420 M3 Blade Server
CONFIGURING the SERVER
7
CONFIGURING the SERVER
Follow these steps to configure the Cisco UCS B420 M3 Blade Server:
STEP 1 VERIFY SERVER SKU, page 8
STEP 2 CHOOSE CPU(S), page 9
STEP 3 CHOOSE MEMORY, page 10
STEP 4 CHOOSE DISK DRIVES (OPTIONAL), page 13
STEP 5 CHOOSE ADAPTERS, page 15
STEP 6 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL), page 19
STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS, page 20
STEP 8 ORDER INTERNAL USB 2.0 DRIVE (OPTIONAL), page 21
STEP 9 ORDER FLASH-BACKED WRITE CACHE (OPTIONAL), page 22
STEP 10 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 23
STEP 11 CHOOSE OPERATING SYSTEM MEDIA KIT (OPTIONAL), page 26
STEP 12 CHOOSE SERVICE and SUPPORT LEVEL, page 27
STEP 13 CHOOSE LOCAL KVM I/O CABLE* (OPTIONAL), page 32
Cisco UCS B420 M3 Blade Server
8
CONFIGURING the SERVER
STEP 1 VERIFY SERVER SKU
Verify the product ID (PID) of the server as shown in Table 2.
The base Cisco UCS B420 M3 blade server does not include the following co
mponents. They must
be selected during product ordering:
CPUs
Memory
Disk drives
Cisco adapters (such as the VIC 1240, VIC 1280, and Port Expander for VIC 1240)
Emulex and QLogic network adapters
Cisco UCS Storage Accelerators (such as the LSI Logic adapter)
Table 2 PID of the Base UCS B420 M3 Blade Server
Product ID (PID) Description
UCSB-B420-M3 UCS B420 M3 Blade Server with no CPU, me
mory, HDD, SSD, mLOM, or adapter
card
NOTE: Use the steps on the following pages to order servers with the
configurable components that you want configured in your servers.
Cisco UCS B420 M3 Blade Server
CONFIGURING the SERVER
9
STEP 2 CHOOSE CPU(S)
The standard CPU features are:
Intel Xeon processor E5-4600 series CPUs
Core counts of 4, 6, or 8
Cache sizes of 10, 12, 15, 16, or 20 MB
Select CPUs
The supported Intel Xeon E5-4600 series CPUs on the UCS B420 M3 are listed in Table 3.
Supported Configurations
(1) Two-CPU Configuration
Choose two identical CPUs from any one of the rows of Table 3. CPUs 1 and 2 will be
populated.
(2) Four-CPU Configuration
Choose four identical CPUs from any one of the rows of Table 3.
Notes
The system will run at the lowest CPU or DIMM clock speed. For example, when using
1600-MHz DIMMs with an E5-4603 CPU (which can only support up to 1066-MHz DIMMs), the
system will run at the lower speed of 1066 MHz.
System speed is also dependent on how many DIMMs are populated per channel.
For 2-CPU systems, only 24 DIMM slots are functional (channels A - H). See Table 9 on page
17 for supported adapter combinations in 2-CPU systems.
For 4-CPU systems, all 48 DIMM slots are functional.
Table 3 Supported Intel CPUs: E5-4600 Ser
ies Processor Family CPUs
Product ID (PID)
Intel
Number
Clock
Freq
(GHz)
Power
(W)
Cache Size
(MB)
Cores QPI
Highest DDR3 DIMM
Clock Support (MHz)
UCS-CPU-E5-4650 E5-4650 2.70 130 20 8 8 GT/s 1600
UCS-CPU-E5-4650L E5-4650L 2.60 115 20 8 8 GT/s 1600
UCS-CPU-E5-4640 E5-4640 2.40 95 20 8 8 GT/s 1600
UCS-CPU-E5-4620 E5-4620 2.20 95 16 8 7.2 GT/s 1333
UCS-CPU-E5-4610 E5-4610 2.40 95 15 6 7.2 GT/s 1333
UCS-CPU-E5-4607 E5-4607 2.20 95 12 6 6.4 GT/s 1066
UCS-CPU-E5-4603 E5-4603 2.00 95 10 4 6.4 GT/s 1066
Cisco UCS B420 M3 Blade Server
10
CONFIGURING the SERVER
STEP 3 CHOOSE MEMORY
The standard memory features are:
DIMMs
Clock speed: 1600 MHz
Ranks per DIMM: 1 or 2
Operational voltage: dual (1.5 or 1.35 V); default = 1.5 V
—Registered
DDR3 ECC registered DIMMs (RDIMMs) or load-reduced DIMMS (LRDIMMS)
Memory is organized with four memory channels per CPU, with up to three DIMMs per
channel (DPC), as shown in Figure 3.
Figure 3 UCS B420 M3 Memory Organization
CPU 1 CPU 2
48 DIMMS
4 memory channels per CPU
3 DIMMs per channel
CPU 3 CPU 4
Channel A
Channel B
Channel C
Channel D
Channel E
Channel F
Channel G
Channel H
Channel M
Channel N
Channel O
Channel P
Channel I
Channel J
Channel K
Channel L
A0A1A2
B2
C2
D2
I2
J2
K2
I2
M2
N2
O2
P2
E2
F2
G2
H2
B0B1
C0C1
D0D1
Bank 0
Bank 1
Bank 2
E0 E1
F0 F1
G0 G1
H0 H1
Bank 0
Bank 1
Bank 2
Bank 0
Bank 1
Bank 2
M0 M1
N0 N1
O0 O1
P0 P1
I0I1
J0J1
K0K1
I0I1
Bank 0
Bank 1
Bank 2
Cisco UCS B420 M3 Blade Server
CONFIGURING the SERVER
11
Choose DIMMs and Memory Mirroring
Select the memory configuration and whether or not you want the memory mirroring option.
The supported memory DIMMs and the mirroring option are listed in Table 4.
When memory mirroring is enabled, the memory subsystem si
multaneously writes identical data
to two adjacent channels. If a memory read from one of the channels returns incorrect data due
to an uncorrectable memory error, the system automatically retrieves the data from the other
channel. A transient or soft error in one channel does not affect the mirrored data, and
operation continues unless there is a simultaneous error in exactly the same location on a DIMM
and its mirrored DIMM. Memory mirroring reduces the amount of memory available to the
operating system by 50% because only one of the two populated channels provides data.
Notes
DIMM configuration rules:
The minimum configuration is 1 DIMM per CPU
The order in which DIMMs must be installed in a channel is Bank 0 (blue socket),
then Bank 1
(black so
cket), then Bank 2 (white socket).
You cannot mix DIMM cap
a
cities within a bank
You can mix DIMM capacities within a channel
You cannot mix RDIMMs with LRDIMMs
LRDIMMs run at a maximum of 1333 MHz
DIMMs default to performance mo
de (1
.5 V). To run DIMMs in power-savings mode
(1.35 V), change the server BIOS settings.
To optimize memory performance:
Configure DIMMs identically for each CPU
Table 4 Supported DDR3 DIMMs and Memory Mirroring Option
Product ID (PID) PID Description Voltage
Ranks
/DIMM
DIMM Options
UCS-ML-1X324RY-A 32 GB DDR3-1600-MHz LRDIMM/PC3-12800/4R/x4/1.35v/35nm 1.35/1.5 V 4
UCS-MR-1X162RY-A 16 GB DDR3-1600-MHz RDIMM PC3-12800/2R/x4/1.35v/35nm 1.35/1.5 V 2
UCS-MR-1X082RY-A 8GB DDR3-1600-MHz RDIMM PC3-12800/2R/x4/1.35v/35nm 1.35/1.5 V 2
UCS-MR-1X041RY-A 4GB DDR3-1600-MHz RDIMM PC3-12800/1R/x4/1.35v/35nm 1.35/1.5 V 1
Memory Mirroring Option
N01-MMIRROR Memory mirroring option
Cisco UCS B420 M3 Blade Server
12
CONFIGURING the SERVER
Fill banks equally across the CPU. See DIMM population guidelines in Table 23,
Table 24, and Table 25.
—Populate less than 3 DPC
Select DIMMs with the highest clock speed
for a given processor
For 3 DPC configurations:
Maximum memory speed is 1066 MHz
Memory always runs at 1.5 V regardless if the BIOS setting is low-p
o
wer mode
(1.35 V) or performance mode (1.5 V)
For more information regarding memory, see DIMM and CPU Layout on page 35.
Supported Configurations
(1) Without memory mirroring:
Select from 1 to 12 DIMMs per CPU (note that there are 12 DIMM slots per CPU). There must
be at least 1 DIMM per CPU.
(2) With memory mirroring:
Select 4 DIMMs per CPU (installed in bank 0), 8 DIMMs per CPU (installed in banks 0, 1), or 12
DIMMs per CPU (installed in banks 0, 1, 2).
Cisco UCS B420 M3 Blade Server
CONFIGURING the SERVER
13
STEP 4 CHOOSE DISK DRIVES (OPTIONAL)
The UCS B420 M3 can be ordered with or without drives. The B420 M3 provides:
Four hot plug 2.5” SFF drive bays
An embedded LSI 2208R RAID controller to provide RAID 0/1/5/10.
Choose Drives
The supported drives in the UCS B420 M3 are listed in Table 5.
NOTE: The UCS B420 M3 blade server meets the external storage target and switch
certifications as described in the following link:
http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/interopera
bilit
y/matrix/Matrix8.html#wp323852
Table 5 Supported Hot Plug Drives
Product ID (PID) PID Description
Drive
Type
Capacity
HDDs
UCS-HDD900GI2F106 900 GB 6Gb SAS 10K RPM SFF HDD SAS 900 GB
A03-D600GA2 600 GB 6Gb SAS 10K RPM SFF HDD SAS 600 GB
UCS-HDD300GI2F105 300 GB 6Gb SAS 15K RPM SFF HDD SAS 300 GB
A03-D300GA2 300 GB 6Gb SAS 10K RPM SFF HDD SAS 300 GB
A03-D146GC2 146 GB 6Gb SAS 15K RPM SFF HDD SAS 146 GB
A03-D1TBSATA 1 TB 6Gb SATA 7.2K RPM SFF HDD SATA 1 TB
A03-D500GC3 500 GB 6Gb SATA 7.2K RPM SFF HDD SATA 500 GB
SSDs
UCS-SD400G0KA2-G 400 GB SATA 2.5" Enterprise Value SSD SATA 400 GB
UCS-SD300G0KA2-E 300 GB Std Height 15mm SATA SSD SATA 300 GB
UCS-SD200G0KA2-E 200 GB Std Height 15mm SATA SSD SATA 200 GB
UCS-SD100G0KA2-G 100 GB SATA 2.5" Enterprise Value SSD SATA 100 GB
UCS-SD100G0KA2-E 100 GB Std Height 15mm SATA SSD SATA 100 GB
Cisco UCS B420 M3 Blade Server
14
CONFIGURING the SERVER
Supported Configurations
Select 1, 2, 3, or 4 of the drives listed in Table 5.
Notes
When creating a RAID volume, mixing different capacity drives causes the system to use the
lowest-capacity drive.
Mixing of drive types is supported, but performance may be impacted. RAID volumes should
use the same media type.
Cisco UCS B420 M3 Blade Server
CONFIGURING the SERVER
15
STEP 5 CHOOSE ADAPTERS
The adapter offerings are:
Cisco Virtual Interface Cards (VICs)
Cisco-developed Virtual Interface Cards (VICs) provid
e flexibility to create multiple NIC and HBA
devices. The VICs also support UCS Fabric Extender technologies.
Converged Network Adapters (CNAs)
Emulex and QLogic Converged Network Adap
ters (CNAs) consolidate Ethernet and Storage (FC)
traffic on the Cisco Unified Fabric.
Cisco UCS Storage Accelerator Adapters
Cisco UCS Storage Accelerator adapters are designed specifically fo
r the Cisco UCS B-series M3
blade servers and integrate seamlessly to allow improvement in performance and relief of I/O
bottlenecks.
Table 6 shows supported adapter slot configurations.
Y
ou must install at least one adapter in one of the three ad
apter slots. Also see Network
Connectivity on page 40 for more information.
To help ensure that your operating system is compati
ble with the cards you have selected,
please check the Hardware Compatibility List at this URL:
http://www.cisco.com/en/US/products/ps10477/prod_technical_referenc
e_list.html
Choose an Adapter
The supported adapters are listed in Table 6.
Table 6 Supported Adapters
Product ID (PID) PID Description
Virtual Interface Cards (VICs)
UCSB-MLOM-40G-01 VIC 1240. Dual 2x10 Gb for UCS M3 Blade Servers.
Insta
lled in adapter slot 1
only.
UCSB-MLOM-PT-01 Cisco UCS Port Expander for VIC 1240. Ena
b
les an additional dual 2x10 Gb for
the VIC 1240, installed in adapter slot 2 only.
UCS-VIC-M82-8P VIC 1280. Dual 4x10 Gb Virtual Interface Card
Converged Network Adapter (CNAs)
UCSB-MEZ-QLG-03 Cisco UCS CNA M73KR-Q QLogic Adapter (dual-port 10 Gb)
UCSB-MEZ-ELX-03 Cisco UCS CNA M73KR-E Emulex (dual-port 10 Gb)
Cisco UCS Storage Accelerators
UCSB-F-FIO-365M Cisco UCS 365 GB MLC Fusion ioDrive2
UCSB-F-LSI-400S LSI 400 GB SLC WarpDrive
Cisco UCS B420 M3 Blade Server
16
CONFIGURING the SERVER
“Adapter 1,” “Adapter 2,” and “Adapter 3” refer to the UCSM naming convention for the
adapter slots (this document uses the UCSM naming convention). In the server BIOS and on the
motherboard, the corresponding slots are labeled as “mLOM,” “Mezz 1,” and “Mezz 2,”
respectively. See
Table 7.
Supported Configurations
(1) 4-CPU System Configuration
Select an adapter combination in accordance with Table 8.
Table 7 Adapter Slot Naming
Server BIOS and Motherboard Slot Naming UCSM Slot Naming
mLOM (VIC 1240 only) Adapter 1
Mezz1 Adapter 2
Mezz2 Adapter 3
Table 8 Supported Adapter
1
Combinations (4-CPU Configuration)
Adapter Slot 1 Adapter Slot 2 Adapter Slot 3 Total Available Bandwidth
2 x 2208 XP 2 x 2204 XP 2 x 2104 XP
VIC 1240 Not populated Not populated 40 Gb
Figure 11 on
page 44
20 Gb
Figure 23 on
page 53
20 Gb
Figure 35 on
page 62
VIC 1240 Not populated VIC 1280 120 Gb
Figure 12 on
page 44
60 Gb
Figure 24 on
page 53
40 Gb
Figure 36 on
page 62
Not populated Not populated VIC 1280 80 Gb
Figure 13 on
page 45
40 Gb
Figure 25 on
page 54
20 Gb
Figure 37 on
page 63
VIC 1240 Not populated Emulex or QLogic
adapter
60 Gb
Figure 14 on
page 45
40 Gb
Figure 26 on
page 54
40 Gb
Figure 38 on
page 63
VIC 1240 Port Expander Card
fo
r VIC 124
0
Not populated 80 Gb
Figure 15 on
page 46
40 Gb
Figure 27 on
page 55
Network I/O
not supported
2
Not populated Not populated Emulex or QLogic
adapter
20 Gb
Figure 16 on
page 47
20 Gb
Figure 28 on
page 55
20 Gb
Figure 39 on
page 64
Not populated Emulex or QLogic
ada
p
ter
Emulex or QLogic
adapter
40 Gb
Figure 17 on
page 47
40 Gb
Figure 29 on
page 56
Network I/O
not supported
2
VIC 1240 Port Expander Card
for VIC 1240
VIC 1280 160 Gb
Figure 18 on
page 48
80 Gb
Figure 30 on
page 57
Network I/O
not supported
2
VIC 1240 Not populated Cisco UCS Storage
Accelerator
3
40 Gb
Figure 19 on
page 49
20 Gb
Figure 31 on
page 58
20 Gb
Figure 40 on
page 64
Cisco UCS B420 M3 Blade Server
CONFIGURING the SERVER
17
(1) 2-CPU System Configuration
Select an adapter combination in accordance with Table 9.
VIC 1240 Cisco UCS Storage
Accelerator
3
Cisco UCS Storage
Accelerator
3
40 Gb
Figure 20 on
page 49
20 Gb
Figure 32 on
page 58
20 Gb
Figure 41 on
page 65
Not populated Cisco UCS Storage
Accelerator
VIC 1280 80 Gb
Figure 21 on
page 50
40 Gb
Figure 33 on
page 59
20 Gb
Figure 42 on
page 65
VIC 1240 Cisco UCS Storage
Accelerator
VIC 1280 120 Gb
Figure 22 on
page 51
60 Gb
Figure 34 on
page 60
40 Gb
Figure 43 on
page 66
Notes
1. In the server BIOS and on the motherboard, “Adapter 1,” “Adapter 2,” and “Adapter 3” are labeled as “mLOM,”
“Mezz 1,” and “Mezz 2,” respectively
2. The 2104XP fabric extender is not compatible with any network I/O card installed in adapter slot 2. However, a
Cisco UCS Storage Accelerator may be installed in adapter slot 3 if it is available.
3. This combination requires that both Storage Accelerators be identical.
Table 9 Supported Adapter
1
Combinations (2-CPU Configuration)
Adapter Slot 1
Adapter Slot 2
2
Adapter Slot 3 Total Available Bandwidth
2 x 2208XP 2 x 2204 XP 2 x 2104 XP
VIC 1240 Not populated Not populated 40 Gb
Figure 11 on
page 44
20 Gb
Figure 23 on
page 53
20 Gb
Figure 35 on
page 62
VIC 1240 Not populated VIC 1280 120 Gb
Figure 12 on
page 44
60 Gb
Figure 24 on
page 53
40 Gb
Figure 36 on
page 62
VIC 1240 Not populated Emulex or QLogic
ada
pter
60
Gb
Figure 14 on
page 45
40 Gb
Figure 26 on
page 54
40 Gb
Figure 38 on
page 63
VIC 1240 Port Expander
Card f
o
r VIC
1240
Not populated 80 Gb
Figure 15 on
page 46
40 Gb
Figure 27 on
page 55
Network I/O not
sup
ported
3
Not populated Not populated Emulex or QLogic
adapter
20 Gb
Figure 16 on
page 47
20 Gb
Figure 28 on
page 55
20 Gb
Figure 39 on
page 64
VIC 1240 Port Expander
Card f
o
r VIC
1240
VIC 1280 160 Gb
Figure 18 on
page 48
80 Gb
Figure 30 on
page 57
Network I/O not
sup
ported
3
VIC 1240 Not populated Cisco UCS
Storage
Ac
celerator
40 Gb
Figure 19 on
page 49
20 Gb
Figure 31 on
page 58
20 Gb
Figure 40 on
page 64
Table 8 Supported Adapter
1
Combinations (4-CPU Configuration) (continued)
Adapter Slot 1 Adapter Slot 2 Adapter Slot 3 Total Available Bandwidth
Cisco UCS B420 M3 Blade Server
18
CONFIGURING the SERVER
Notes
1. In the server BIOS and on the motherboard, “Adapter 1,” “Adapter 2,” and “Adapter 3” are labeled as
“mLOM,” “Mezz 1,” and “Mezz 2,” respectively
2. Only the Port Expander for VIC 1240 is functional in adapter slot 2 in 2-CPU configurations
3. The 2104XP fabric extender is not compatible with any network I/O card installed in adapter slot 2.
Cisco UCS B420 M3 Blade Server
CONFIGURING the SERVER
19
STEP 6 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL)
Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store
artifacts used to authenticate the platform (server). These artifacts can include passwords,
certificates, or encryption keys. A TPM can also be used to store platform measurements that
help ensure that the platform remains trustworthy. Authentication (ensuring that the platform
can prove that it is what it claims to be) and attestation (a process helping to prove that a
platform is trustworthy and has not been breached) are necessary steps to ensure safer
computing in all environments.
The TPM ordering information is listed in Table 10.
Table 10 Trusted Platform Module
Product ID (PID) PID Description
UCSX-TPM1-001 Truste d P l a tform M o d u l e for UCS
Cisco UCS B420 M3 Blade Server
20
CONFIGURING the SERVER
STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS
Dual SDHC flash card sockets are provided on the front left side of the server.
The SDHC card ordering information is listed in Table 11.
Future Supported Configurations
(1) Select one or two Cisco Flexible Flash secure digital cards
NOTE: Cisco Flexible Flash secure digital cards are currently orderable; however,
they will be enabled only with future firmware and software updates.
Table 11 Future Supported Configurations - Secure Digital Card(s)
Product ID (PID) PID Description
UCS-SD-16G 16GB SD Card module for UCS Servers
NOTE: The SD card transfer rates are:
Sequential reads: 23 MB/s
Sequential writes: 20 MB/s
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68