ENDRESS+HAUSER dosimass Operating Instructions Manual

Category
Measuring & layout tools
Type
Operating Instructions Manual
BA 097D/06/en/12.03
50106488
valid as of software version
Version 1.00.XX
dosimass
Coriolis mass flow measuring
system
For filling applications
Operating Instructions
Dosimass
2Endress+Hauser
Dosimass brief operating instructions
You can commission your device quickly and easily with the following brief operating
instructions:
Safety instructions Page 5 ff.
Installation Page 8 ff.
Wiring Page 13 ff.
Operation Page 17 ff.
Customer-specific configuration
Complex measuring tasks require the configuration of additional functions which
users can individually select, configure and adapt to their process conditions via
the function matrix.
!Note!
A detailed description of all the functions as well as a detailed overview of the
function matrix is provided on Chap. 11, Page 46.
Dosimass Endress+Hauser
Endress+Hauser 3
Table of contents
1 Safety instructions . . . . . . . . . . . . . . 5
1.1 Designated use . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Installation, commissioning and operation . . . 5
1.3 Operational safety . . . . . . . . . . . . . . . . . . . . . . 5
1.4 Return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.5 Notes on safety conventions and icons . . . . . . 6
2 Identification . . . . . . . . . . . . . . . . . . . 7
2.1 Device designation . . . . . . . . . . . . . . . . . . . . . 7
2.1.1 Nameplate . . . . . . . . . . . . . . . . . . . . . . 7
2.2 Certificates and approvals . . . . . . . . . . . . . . . . 7
2.3 Registered trademarks . . . . . . . . . . . . . . . . . . 7
3 Installation. . . . . . . . . . . . . . . . . . . . . 8
3.1 Incoming acceptance, transport, storage . . . . 8
3.1.1 Incoming acceptance . . . . . . . . . . . . . 8
3.1.2 Transport . . . . . . . . . . . . . . . . . . . . . . . 8
3.1.3 Storage . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.2 Installation conditions . . . . . . . . . . . . . . . . . . . 8
3.2.1 Dimensions . . . . . . . . . . . . . . . . . . . . . . 8
3.2.2 Mounting location . . . . . . . . . . . . . . . . . 9
3.2.3 Orientation . . . . . . . . . . . . . . . . . . . . . 11
3.2.4 Heating, heating insulation . . . . . . . . . 12
3.2.5 Inlet and outlet run . . . . . . . . . . . . . . . 12
3.2.6 Vibrations . . . . . . . . . . . . . . . . . . . . . . 12
3.2.7 Limiting flow . . . . . . . . . . . . . . . . . . . . 12
3.3 Post-installation check . . . . . . . . . . . . . . . . . . 12
4 Wiring . . . . . . . . . . . . . . . . . . . . . . . . 13
4.1 Connecting the measuring unit . . . . . . . . . . . 13
4.1.1 Wiring diagram . . . . . . . . . . . . . . . . . . 13
4.1.2 Ground connection . . . . . . . . . . . . . . . 14
4.1.3 Cable specification . . . . . . . . . . . . . . . 14
4.1.4 Connection examples . . . . . . . . . . . . . 15
4.2 Potential equalisation . . . . . . . . . . . . . . . . . . . 16
4.3 Degree of protection . . . . . . . . . . . . . . . . . . . 16
4.4 Post-connection check . . . . . . . . . . . . . . . . . 16
5 Operation . . . . . . . . . . . . . . . . . . . . . 17
5.1 FieldTool operating program . . . . . . . . . . . . . 17
5.2 Structure of the function matrix . . . . . . . . . . . 18
5.2.1 General notes . . . . . . . . . . . . . . . . . . . 19
6 Commissioning . . . . . . . . . . . . . . . . 20
6.1 Function check . . . . . . . . . . . . . . . . . . . . . . . 20
6.2 Switching on the measuring device . . . . . . . . 20
6.3 Zero point adjustment . . . . . . . . . . . . . . . . . . 20
6.3.1 Preconditions for a zero point
adjustment . . . . . . . . . . . . . . . . . . . . . 21
6.3.2 Performing a zero point adjustment . . 21
7 Maintenance . . . . . . . . . . . . . . . . . . . 22
8 Accessories/spare parts. . . . . . . . . . 23
9 Trouble-shooting . . . . . . . . . . . . . . . 24
9.1 Trouble-shooting instructions . . . . . . . . . . . . . 24
9.2 Types of error . . . . . . . . . . . . . . . . . . . . . . . . . 24
9.2.1 Type of error . . . . . . . . . . . . . . . . . . . . 24
9.2.2 Error message types . . . . . . . . . . . . . . 24
9.3 Fault diagnosis via the
light emitting diode (LED) . . . . . . . . . . . . . . . . 25
9.4 System error messages (FieldTool) . . . . . . . . 26
9.5 Process error messages (FieldTool) . . . . . . . . 28
9.6 Process errors without message . . . . . . . . . . 29
9.7 Response of outputs to errors . . . . . . . . . . . . 30
9.8 Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
9.9 Installing/removing the electronics . . . . . . . . . 31
9.10 Replacing the device fuse . . . . . . . . . . . . . . . 32
9.11 Software history . . . . . . . . . . . . . . . . . . . . . . . 32
9.12 Return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
9.13 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
10 Technical data . . . . . . . . . . . . . . . . . 33
10.1 Technical data at a glance . . . . . . . . . . . . . . . 33
10.1.1 Application . . . . . . . . . . . . . . . . . . . . . . 33
10.1.2 Function and system design . . . . . . . . 33
10.1.3 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
10.1.4 Output . . . . . . . . . . . . . . . . . . . . . . . . . 34
10.1.5 Power supply . . . . . . . . . . . . . . . . . . . . 34
10.1.6 Performance characteristics . . . . . . . . 35
10.1.7 Operating conditions: Installation . . . . 36
10.1.8 Operating conditions: Environment . . . 36
10.1.9 Operating conditions: Process . . . . . . 37
10.1.10 Mechanical construction . . . . . . . . . . 39
10.1.11 User interface . . . . . . . . . . . . . . . . . . 39
10.1.12 Certificates and approvals . . . . . . . . . 40
10.1.13 Ordering information . . . . . . . . . . . . . 40
10.1.14 Accessories/spare parts . . . . . . . . . . 40
10.1.15 Supplementary Documentation . . . . . 40
10.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
10.2.1 Dosimass dimensions:
Tri-Clamp connections . . . . . . . . . . . . 41
10.2.2 Dosimass dimensions:
DIN 11851 connections
(sanitary connection) . . . . . . . . . . . . . . 42
10.2.3 Dosimass dimensions :
DIN 11864-1 Form A (threaded joint) . 43
10.2.4 Dosimass dimensions :
ISO 2853 connections (threaded joint) 44
10.2.5 Dosimass dimensions:
SMS 1145 connections
(sanitary connection) . . . . . . . . . . . . . . 45
Dosimass Endress+Hauser
4Endress+Hauser
11 Appendix - Function description . . 46
11.1 Function group "MEASURING VALUES" . . . . 46
11.2 Function group "SYSTEM UNITS" . . . . . . . . . 47
11.3 Function group "PULSE OUTPUT" . . . . . . . . 49
11.4 Function group "STATUS OUTPUT" . . . . . . . 51
11.5 Function group "COMMUNICATION" . . . . . . 51
11.6 Function group "PROCESS PARAMETER" . . 52
11.7 Function group "SYSTEM PARAMETER" . . . . 55
11.8 Function group "SENSOR PARAMETER" . . . 56
11.9 Function group "SUPERVISION" . . . . . . . . . . 57
11.10 Function group "SIMULATION" . . . . . . . . . . . 58
11.11 Function group "SENSOR VERSION" . . . . . . 58
11.12 Function group "AMPLIFIER VERSION" . . . . 58
Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Dosimass Safety instructions
Endress+Hauser 5
1 Safety instructions
1.1 Designated use
The measuring device described in these Operating Instructions is to be used only for
measuring the mass flow or volume flow rate of liquids. Fluids with widely differing
properties can be measured.
Examples:
Additives
Oils, fats
Acids, alkalis
Varnishes, paints
Suspensions
Resulting from incorrect use or from use other than that designated, the operational
safety of the measuring devices can be suspended. The manufacturer accepts no
liability for damages being produced from this.
1.2 Installation, commissioning and operation
Note the following points:
Installation, connection to the electricity supply, commissioning and maintenance of
the device must be carried out by trained, qualified specialists authorised to perform
such work by the facility's owner operator. The specialist must have read and
understood these Operating Instructions and must follow the instructions they contain.
The device must be operated by persons authorised and trained by the facility's
owner-operator. Strict compliance with the instructions in the Operating Instructions
is mandatory.
Endress+Hauser will be happy to assist in clarifying the chemical resistance
properties of parts wetted by special fluids, including fluids used for cleaning.
However the user is responsible for the choice of fluid wetted materials for their in-
process resistance to corrosion. The manufacturer refuses to accept liability.
The installer must ensure that the measuring system is correctly wired in accordance
with the wiring diagrams.
Invariably, local regulations governing the opening and repair of electrical devices
apply.
1.3 Operational safety
Note the following points:
Measuring systems for use in hazardous environments are accompanied by separate
“Ex documentation”, which is an integral part of these Operating Instructions. Strict
compliance with the installation instructions and ratings as stated in this
supplementary documentation is mandatory. The symbol on the front of the
supplementary Ex documentation indicates the approval and the testing body
(0Europe, 2 USA, 1 Canada).
The measuring device complies with the general safety requirements in accordance
with EN 61010, the EMC requirements of EN 61326/A1 and NAMUR recommendation
NE 21.
The manufacturer reserves the right to modify technical data without prior notice. Your
E+H distributor will supply you with current information and updates to these
Operating Instructions.
Safety instructions Dosimass
6Endress+Hauser
1.4 Return
The following procedures must be carried out before a flowmeter requiring repair or
calibration, for example, is returned to Endress+Hauser:
Always enclose a duly completed “Declaration of contamination” form. Only then can
Endress+Hauser transport, examine and repair a returned device.
Enclose special handling instructions if necessary, for example a safety data sheet as
per EN 91/155/EEC.
Remove all residues. Pay special attention to the grooves for seals and crevices which
could contain residues. This is particularly important if the substance is hazardous to
health, e.g. flammable, toxic, caustic, carcinogenic, etc.
!Note!
You will find a preprinted “Declaration of contamination” form at the back of this manual.
#Warning!
Do not return a measuring device if you are not absolutely certain that all traces of
hazardous substances have been removed, e.g. substances which have penetrated
crevices or diffused through plastic.
Costs incurred for waste disposal and injury (burns, etc.) due to inadequate cleaning
will be charged to the owner operator.
1.5 Notes on safety conventions and icons
The devices are designed to meet state-of-the-art safety requirements, have been
tested, and left the factory in a condition in which they are safe to operate. The devices
comply with the applicable standards and regulations in accordance with EN 61010
“Protection Measures for Electrical Equipment for Measurement, Control, Regulation
and Laboratory Procedures”. They can, however, be a source of danger if used
incorrectly or for use other than that designated.
Consequently, always pay particular attention to the safety instructions indicated in
these Operating Instructions by the following icons:
#Warning!
“Warning” indicates an action or procedure which, if not performed correctly, can result
in injury or a safety hazard. Comply strictly with the instructions and proceed with care.
"Caution!
“Caution” indicates an action or procedure which, if not performed correctly, can result
in incorrect operation or destruction of the device. Comply strictly with the instructions.
!Note!
“Note” indicates an action or procedure which, if not performed correctly, can have an
indirect effect on operation or trigger an unexpected response on the part of the device.
Dosimass Identification
Endress+Hauser 7
2 Identification
2.1 Device designation
The “Dosimass” flow measuring system consists of a compact measuring device and is
supplied as a mechanical unit.
2.1.1 Nameplate
F06-8BExxxxx-18-06-xx-xx-000
Fig. 1: Nameplate specifications for the “ Dosimass” transmitter (example)
1 Order code/serial number: see the specifications on the order confirmation for the meanings of the
individual letters and digits.
2 Power supply: 24VDC (20...30 VDC)
Power consumption: 4.3 W
3 Process connection: DN 25, 1" Tri-Clamp
4 Materials: 1.4539 (AISI UNS N 08904)
5 Maximum process temperature: +125°C (+257°F)
6 Flow calibration: calibration factor = 1.000, zero point = 0
7 Reserved for information on special products
8 Ambient temperature range
9 Reserved for additional information on device version (approvals, certificates)
10 Degree of protection
11 Fluid flow direction
2.2 Certificates and approvals
The devices are designed to meet state-of-the-art safety requirements, have been
tested, and left the factory in a condition in which they are safe to operate. The devices
comply with the applicable standards and regulations in accordance with EN 61010
“Protection Measures for Electrical Equipment for Measurement, Control, Regulation
and Laboratory Procedures”.
The measuring system described in these Operating Instructions thus complies with the
statutory requirements of the EC Directives. Endress+Hauser confirms successful
testing of the device by affixing to it the CE mark.
2.3 Registered trademarks
TRI-CLAMP ®
Registered trademark of Ladish & Co., Inc., Kenosha, USA
FieldTool™, FieldCheck™, Applicator™
Registered or registration-pending trademarks of Endress+Hauser Flowtec AG,
Reinach, CH
i
-20°C (-4°F) <Tamb<+60°C (140°F)
DOSIMASS
ENDRESS+HAUSER
Materials:
TMmax.: 125°C/257°F
1.4539/904L
Order Code:
24 VDC nominal (20...30VDC)
TAG No.:
DN25 - 1” TRICLAMP
Ser.No.:
XXXXX-XXXXXXX
12345678901
ABCDEFGHJKLMNP
IP67 / NEMA/Type4X
4.3W
FEK1486
28-03
R
Ta+20°C/68°F
1.000 / 0K-factor:
3.1B, 0.8 / 150gritµm
1
2
3
4
5
6
7
8
9
10
11
Installation Dosimass
8Endress+Hauser
3 Installation
3.1 Incoming acceptance, transport, storage
3.1.1 Incoming acceptance
On receipt of the goods, check the following points:
Check the packaging and the contents for damage.
Check the shipment, make sure nothing is missing and that the scope of supply
matches your order.
3.1.2 Transport
The following instructions apply to unpacking and to transporting the device to its final
location:
Transport the devices in the containers in which they are delivered.
The covers or caps fitted to the process connections prevent mechanical damage to
the sealing faces and the ingress of foreign matter to the measuring tube during
transportation and storage. Consequently, do not remove these covers or caps until
immediately before installation.
#Warning!
Risk of injury if the measuring device slips. The centre of gravity of the assembled
measuring device might be higher than the points around which the slings are slung.
At all times, therefore, make sure that the device does not unexpectedly turn around its
axis or slip.
3.1.3 Storage
Note the following points:
Pack the measuring device in such a way as to protect it reliably against impact for
storage (and transportation). The original packaging provides optimum protection.
The permissible storage temperature is -40...+80 °C (preferably +20 °C).
Do not remove the protective covers or caps on the process connections until you are
ready to install the device.
The measuring device must be protected against direct sunlight during storage in
order to avoid unacceptably high surface temperatures.
3.2 Installation conditions
Note the following points:
No special measures such as supports are necessary. External forces are absorbed
by the construction of the instrument.
The high oscillation frequency of the measuring tubes ensures that the correct
operation of the measuring system is not influenced by plant vibrations.
No special precautions need to be taken for fittings which create turbulence (valves,
elbows, Tpieces, etc.), as long as no cavitation occurs.
3.2.1 Dimensions
The dimensions and the fitting lengths of the transmitter and sensor are on Page 41.
Dosimass Installation
Endress+Hauser 9
3.2.2 Mounting location
Correct measurement is only possible if the pipe is filled. For this reason, avoid the
following mounting locations in the pipe:
At the highest point of the pipeline. Risk of air accumulating.
Directly upstream of a free pipe outlet in a down pipe.
F06-8BExxxxx-11-00-00-xx-004
Fig. 2: Mounting location
The following proposed installation, however, permits installation in an open down pipe.
Pipe restrictors or the use of an orifice with a cross-section smaller than the nominal
diameter prevent the pipe from running empty during measurement.
F06-8BExxxxx-11-00-00-xx-002
Fig. 3: Installation in a down pipe (e.g. for batching applications)
1 Supply tank
2Sensor
3 Orifice plate, pipe restriction
4Valve
5 Batching tank
1
2
3
4
5
Dosimass / DN 81525
Orifice plate, pipe restriction 6 mm 10 mm 14 mm
Installation Dosimass
10 Endress+Hauser
System pressure
It is important to ensure that cavitation does not occur because it would influence the
oscillation of the measuring tube. No special measures need to be taken for fluids which
have properties similar to water under normal conditions.
In the case of liquids with a low boiling point (hydrocarbons, solvents, liquefied gases)
or in suction lines, it is important to ensure that pressure does not drop below the vapour
pressure and that the liquid does not start to boil. It is also important to ensure that the
gases that occur naturally in many liquids do not outgas. Such effects can be prevented
when system pressure is sufficiently high.
Consequently, it is generally best to install the sensor:
downstream from pumps (no danger of vacuum),
at the lowest point in an ascending pipeline.
Dosimass Installation
Endress+Hauser 11
3.2.3 Orientation
Vertical:
Recommended orientation with upward direction of flow. When fluid is not flowing,
entrained solids will sink down and gases will rise away from the measuring tube. The
measuring tubes can be completely drained and protected against solids build-up.
F06-8BExxxxx-11-00-00-xx-000
Fig. 4: Dosimass orientation
Horizontal:
The measuring tubes of Dosimass must be horizontal and beside each other. When
installation is correct, the transmitter housing is above or below the pipe (View 2, 3).
Always avoid having the transmitter housing in a lateral position.
"Caution!
The measuring tubes of Dosimass are slightly curved. The position of the sensor,
therefore, has to be matched to the fluid properties when the sensor is installed
horizontally (Fig. 5).
F06-8BExxxxx-11-00-00-xx-003
Fig. 5: Horizontal installation with Dosimass
1 Not suitable for fluids with entrained solids. Risk of solids accumulating.
2 Not suitable for outgassing fluids. Risk of air accumulating.
Fluid temperature
"Caution!
Hot surface temperatures can arise at the housing of the device if fluid temperatures are
>70°C.
In order to ensure that the maximum permissible ambient temperature for the transmitter
(-20...+60 °C) is not exceeded, we recommend the following orientations:
High fluid temperature
Vertical line: installation as per diagram Fig. 4/ view 1
Horizontal line: installation as per diagram Fig. 4/ view 3
Low fluid temperature
Vertical line: installation as per diagram Fig. 4/ view 1
Horizontal line: installation as per diagram Fig. 4/ view 2
123
12
Installation Dosimass
12 Endress+Hauser
3.2.4 Heating, heating insulation
Some fluids require suitable measures to avoid loss of heat or heat supply at the sensor.
A wide range of materials can be used to provide the required thermal insulation.
Heating can be electric, e.g. with electric band heaters, or by means of hot water or
steam pipes made of copper.
"Caution!
Risk of electronics overheating!
Consequently, make sure that the adapter between sensor and transmitter always
remains free of insulating material. Note that a certain orientation might be required,
depending on the fluid temperature (Chap. 3.2.3 “Fluid temperature”
sectionPage 11).
Information on permissible temperature ranges Page 36.
3.2.5 Inlet and outlet run
There are no installation requirements regarding inlet and outlet runs. If possible, install
the sensor before fittings such as valves, T-pieces, elbows, etc.
3.2.6 Vibrations
The high oscillation frequency of the measuring tubes ensures that the correct operation
of the measuring system is not influenced by pipe vibrations. Consequently, the sensors
require no special measures for attachment.
3.2.7 Limiting flow
See the information on Page 33 and 37.
3.3 Post-installation check
Perform the following checks after installing the measuring device in the pipe:
Device condition and specifications Notes
Is the device damaged (visual inspection)? -
Does the device correspond to specifications at the measuring point,
including process temperature and pressure, ambient temperature,
measuring range, etc.?
seePage33ff.
Installation Notes
Does the arrow on the sensor nameplate match the direction of flow
through the pipe?
-
Are the measuring point number and labelling correct (visual
inspection)?
-
Is the orientation chosen for the sensor correct, in other words suitable
for sensor type, fluid properties (outgassing, with entrained solids) and
fluid temperature?
seePage8ff.
Process environment / process conditions Notes
Is the measuring device protected against moisture and direct sunlight? -
Dosimass Wiring
Endress+Hauser 13
4Wiring
#Warning!
When connecting Ex-certified devices, see the notes and diagrams in the Ex-specific
supplement to these Operating Instructions. Please do not hesitate to contact your E+H
sales office if you have any questions.
4.1 Connecting the measuring unit
#Warning!
The device may only be connected to SELV, PELV or CLASS 2 circuits. This applies
both to the power supply and to the outputs.
!Note!
Switch off the power supply before opening the device. Do not install or wire the
device while it is connected to the power supply.
Earth the device before applying the power supply.
4.1.1 Wiring diagram
The electrical connection of the device is established using a Lumberg connector (type
RSE8 or RSE4, M12x1).
F06-xBxxxxxx-04-xx-xx-xx-000
Fig. 6: Wiring diagram
A = Socket at device
B = Cable connector
1 = (+), power supply (24VDC nominal voltage (20...30 VDC), 4.3 W)
4 = (-), power supply (24VDC nominal voltage (20...30 VDC), 4.3 W)
5 = (+), pulse, status output (max. 30 V)
6 = (-), pulse output (max. 250 mA)
7 = (-), status output (max. 250 mA)
2 = Service interface (may not be connected during normal operation)
3 = Service interface (may not be connected during normal operation)
8 = Service interface (may not be connected during normal operation)
A
A
1
2
3
4
5
6
7
8
1
5
4
6
RSE4
1
2
3
4
5
6
7
8
1
5
4
6
B
B
RSE8
Wiring Dosimass
14 Endress+Hauser
4.1.2 Ground connection
The ground connection is established via a cable lug.
F06-xBxxxxxx-04-xx-xx-xx-001
Fig. 7: Dosimass ground connection
4.1.3 Cable specification
Every suitable cable with a temperature specification at least 20 °C higher than the
ambient temperature in the application. We recommend you use a cable with a
temperature specification of +80 °C.
Dosimass Wiring
Endress+Hauser 15
4.1.4 Connection examples
Eight-pin version
F06-8BExxxxx-04-xx-xx-xx-001
Fig. 8: Connection example (eight-pin version)
a PELV or SELV power supply
b Housing
Four-pin version
F06-8BExxxxx-04-xx-xx-xx-000
Fig. 9: Connection example (four-pin version)
a PELV or SELV power supply
b Housing
+
-
=
PE
a
1
4
5
6
7
b
+
-
=
PE
a
1
4
5
6
7
Wiring Dosimass
16 Endress+Hauser
4.2 Potential equalisation
No special measures are necessary for potential equalisation.
!Note!
For devices for the Ex area, see the notes in the Ex-specific supplement to these
Operating Instructions.
4.3 Degree of protection
The devices fulfil all the requirements for IP 67.
Compliance with the following points is mandatory following installation in the field or
servicing, in order to ensure that IP 67 protection is maintained:
The housing seals must be clean and undamaged when inserted into their grooves.
The seals must be dried, cleaned or replaced if necessary.
All threaded fasteners and screw covers must be firmly tightened.
4.4 Post-connection check
Perform the following checks after completing electrical installation of the measuring
device:
Device condition and specifications Notes
Is the device damaged (visual inspection)? -
Electrical connection Notes
Does the supply voltage match the specifications on the nameplate? 24VDC nominal voltage
(20...30VDC)
Do the cables have adequate strain relief? -
Is the cable type route completely isolated?
Without loops and crossovers?
-
Are the power supply and signal cables correctly connected? -
Is the housing cover installed and firmly tightened? -
Dosimass Operation
Endress+Hauser 17
5Operation
5.1 FieldTool operating program
The Dosimass flow measuring device is operated via the “FieldTool” operating program.
FieldTool is a universal service and configuration software package from
Endress+Hauser. Connection is by means of the PROline service interface (service
connector) with a Commubox FXA 193.
!Note!
You can find more information on FieldTool and how it is operated in the appropriate on-
line help.
The functionality of FieldTool includes the following:
Configuration of device functions
Visualisation of measuring values (including data logging)
Data backup of device parameters
Measuring-point documentation
Operation Dosimass
18 Endress+Hauser
5.2 Structure of the function matrix
Function group Function
MEASURING
VALUES
(Page 46)
MASS FLOW
(Page 46)
VOLUME FLOW
(Page 46)
DENSITY
(Page 46)
TEMPERATURE
(Page 46)
SYSTEM UNITS
(Page 47)
UNIT MASS FLOW
(Page 47)
UNIT MASS
(Page 47)
UNIT VOL. FLOW
(Page 47)
UNIT VOLUME
(Page 48)
UNIT DENSITY
(Page 48)
UNIT
TEMPERATURE
(Page 48)
PULSE OUTPUT
(Page 49)
ASSIGN PULSE
(Page 49)
PULSE VALUE
(Page 49)
PULSE WIDTH
(Page 49)
OUTPUT SIGNAL
(Page 50)
FAILSAFE MODE
(Page 50)
STATUS OUTPUT
(Page 51)
ASSIGN STATUS
(Page 51)
ACTUAL STATUS
(Page 51)
COMMUNICATION
(Page 51)
TAG NAME
(Page 51)
PROCESS
PARAMETER
(Page 52)
ASSIGN LOW-
FLOW CUTOFF
(Page 52)
ON-VAL. LOW-
FLOW CUTOFF
(Page 52)
PRESS. SHOCK
SUPPRESSION
(Page 53)
EPD VALUE LOW
(Page 53)
EPD RESPONSE
TIME
(Page 54)
ZERO ADJUST.
(Page 54)
ZERO POINT
(Page 54)
SYSTEM
PARAMETER
(Page 55)
INSTALL. DIRECT.
SENSOR
(Page 55)
FLOW DAMPING
(Page 55)
SENSOR
PARAMETER
(Page 56)
K-FACTOR
(Page 56)
ZEROPOINT
(Page 56)
NOMINAL
DIAMETER
(Page 56)
C0
(Page 56)
C1
(Page 56)
C2
(Page 56)
C3
(Page 56)
C4
(Page 56)
C5
(Page 56)
MIN.TEMP.
MEAS.
(Page 56)
MAX.TEMP. MEAS.
(Page 56)
SUPERVISION
(Page 57)
ACT. SYS. COND
(Page 57)
PREV. SYS. COND
(Page 57)
ALARM DELAY
(Page 57)
SYSTEM RESET
(Page 57)
SIMULATION
SYSTEM
(Page 58)
SIM. MEASURAND
(Page 58)
VALUE SIM. MEAS.
(Page 58) continued on next page
Dosimass Operation
Endress+Hauser 19
5.2.1 General notes
The function matrix comprises a multiplicity of functions which, for the sake of clarity,
are arranged in a number of function groups.
!Note!
The transmitter continues to measure while data entry is in progress, i.e. the current
measured values are output via the signal outputs in the normal way.
If the supply voltage fails, all preset and configured values remain safely stored in the
EEPROM.
"Caution!
Changing certain parameters such as all sensor characteristics, for example, influences
numerous functions of the entire measuring system, particularly measuring accuracy.
Such parameters normally may not be altered and are thus protected. Please contact
Endress+Hauser if you have any questions.
Function group Function
SENSOR VERSION
(Page 58)
SERIAL NUMBER
(Page 58)
SENSOR TYPE
(Page 58)
SW REV. DAT
(Page 58)
AMPLIFIER VERSION
(Page 58)
SW REV. AMP.
(Page 58)
Commissioning Dosimass
20 Endress+Hauser
6 Commissioning
6.1 Function check
Make sure that all final checks have been completed before you start up your measuring
point:
Checklist for “Post-installation check” Page 12
Checklist for “Post-connection check” Page 16
6.2 Switching on the measuring device
Once the function checks have been successfully completed, it is time to switch on the
supply voltage. The device is now operational.
The measuring device performs a number of power on self-tests. Normal measuring
mode commences as soon as start-up completes.
!Note!
If start-up fails, an error message indicating the cause is displayed in the FieldTool
operating program.
6.3 Zero point adjustment
All Dosimass measuring devices are calibrated with state-of-the-art technology. The
zero point obtained in this way is printed on the nameplate. Calibration takes place
under reference operating conditions (Page 35). Consequently, zero point
adjustment is generally not necessary for Dosimass!
Experience shows that the zero point adjustment is advisable only in special cases:
To achieve highest measuring accuracy also with very small flow rates.
Under extreme process or operating conditions (e.g. very high process temperatures
or very high-viscosity fluids).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64