Kichler Lighting 44249NILED40 User manual

Type
User manual

This manual is also suitable for

We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
IS-44249LED-US
This device complies with part 15 of the FCC Rules. Operaon is
subject to the following two condions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including
interference that may cause undesired operaon.
Note: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protecon
against harmful interference in a residenal installaon. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instrucons,
may cause harmful interference to radio communicaons.
However, there is no guarantee that interference will not occur
in a parcular installaon. If this equipment does cause harmful
interference to radio or television recepon, which can be
determined by turning the equipment o and on, the user is
encouraged to try to correct the interference by one or more of
the following measures:
Reorient or relocate the receiving antenna.
Increase the separaon between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent
from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for
help.
FCC Informaon:
*Note: Due to the mounng hole conguraon in many joist-
mounted 3” round juncon boxes, square Zeo xtures (44245,
44247 and 44249) may not mount square with the walls of the
room.
Installaon Instrucons
1) Check to make sure xture will be oriented correctly
once installaon is complete. Mounng plate can be
adjusted to suit posion of xture.
2) Remove decorave trim[I] by carefuly pressing on rear
edge unl the snap clips disengage.
3) Connect xture ground to outlet box ground using
supplied connector.
4) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw then thread into
mounng strap.
If xture is provided with ground wire. Connect xture
ground wire to outlet box ground wire with wire
connector (Not provided) aer following the above
steps. Never connect ground wire to black or white
power supply wires.
5) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
6) Posion the xture[D] over the outlet box[B] making
sure the center of the xture is centered over the outlet
box. Align spring clips[E] and tabs[F] in mounng
bracket and insert unl spring clips pull the xture
to ceiling surface. NOTE: Be certain wires do not get
pinched between xture and ceiling.
7) Push the drywall anchor screws[H] through the anchor
holes[G] in the xture then screw them into the ceiling
to secure the xture in place.
8) Install decorave trim by pressing trim rmly against
xture unl snap clips engage.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
Warning:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Fixture Diagram
Parts List
[A] Mounting
Plate
[B] Outlet Box
[C] Mounting
Screws
[D] Fixture
[E] Spring Clips
[F] Installation
Bracket Tabs
[G] Anchor Holes
[H] Drywall
Anchors
Screws
[I] Decorative
Ring
Cauons
Kichler Zeo Juncon Box Requirements
To comply with the Naonal Electric Code (NEC), Kichler Zeo
light xtures require a juncon box with a minimum internal
volume of 18 cubic inches (in3) for installaon (internal
volume is typically called out on the inside panel).
The juncon boxes listed below meet the minimum
requirements. Be sure to select a size and shape that has a
depth greater than or equal to the specied minimum depth.
Juncon
Box Shape
and
Diameter
4”
Square
4”
Octagonal
3”
Round*
4”
Round
Minimum
Depth
1-1/2 2-1/8 3” 2-1/4
B
C
A
E
D
I
G
F
H
  • Page 1 1
  • Page 2 2
  • Page 3 3

Kichler Lighting 44249NILED40 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI