Rinnai V94IP Specification

Type
Specification

This manual is also suitable for

Type of Appliance
Rinnai Model Number
Operation / Installation
Minimum/Maximum Gas Rate (Input)
Electrical
Electrical Consumption
Amperage
Ignition System
Hot Water Capacity
Temperature
Temperature (without remote)
Installation
Energy Factor
Service Connections
Water Flow Control
Minimum/Maximum Water Supply Pressure
Temperature controlled, continuous flow, gas hot water system
Certified for installation in manufactured (mobile) homes
Forced combustion / Direct vent
REU-VC2837FFU-US
Forced combustion; indoor only
10,300 - 199,000 BTU/h (3.02-58.3kWh)
Appliance: AC 120 Volts - 60 Hz
Controller: DC 12 Volts
Normal: 97 w Standby: 2 w Anti-frost protection: 120 w
Max : 4A Fuse: 10A
Direct electronic ignition
Minimum flow rate: 0.26 GPM (1 l/min)
Minimum activation flow rate: 0.4 GPM (1.5l /min)
Maximum flow rate: 9.8 GPM (37.1 l/min)
98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable
at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with
the MCC-91-2 controller for hydronic applications
120°F (49°C) (factory default) or 140°F (60°C)
Indoor only
Natural Gas: 0.82 Propane: 0.82
Gas supply: 3/4 inch(19mm) MNPT, Cold water inlet: 3/4 inch(19mm) MNPT
Hot water outlet: 3/4 inch(19mm) MNPT
Water flow sensor, electronic water control device and by-pass
20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for
optimal performance)
© 2015 Rinnai V94i VC SP 8/2015
FLOW TABLE
V94i (VC2837FFU-US)
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Low Lead Content
NSF/ANSI 372
C U
SANITATION
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
0 25 50 75 100 125 150
Water Flow gpm (l/min)
delta T - Temperature Rise (ºF)
25(13.9) 50(27.8) 75(41.6) 100(55.6) 125(69.4)
150(83.3)
0
6.0 (22.7)
1.0 (3.8)
2.0 (7.6)
3.0 (11.4)
0.0
5.0 (19.0)
4.0 (15.1)
7.0 (26.5)
10.0 (37.9)
9.0 (34.1)
8.0 (30.3)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
Water Temperature Control
Controller
Controller Cable
Safety Devices
Clearances from Combustibles
(suitable for closet, attic, and
crawl space installations)
Clearances from Non-combustibles
Min. / Max. Gas Supply Pressure
(sea level)
Manifold Gas Pressure (inches W.C.)
NOx
Simulation feed forward and feedback
MC-91-2US (part of the front panel)
Deluxe controller: MC-100V-1US (optional)
Bathroom controller: BC-100V-1US (optional)
MCC-91-2US (optional; for hydronic and commercial applications)
Non-polarized two-core cable, minimum 22 AWG
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse
Top of heater - 6 inches (152mm)
Front of heater - 6 inches (152mm)
Sides of heater - 2 inches (51mm)
Top of heater - 2 inches (51mm)
Front of heater - 6 inches (152mm)
Sides of heater - 1/2 inch (13mm)
Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar)
Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Natural Gas: high fire 2.9” W.C. (7.22mbar) low fire 0.61” W.C. (1.52mbar)
Propane Gas: high fire 4.7” W.C. (11.71mbar) low fire 0.87” W.C. (2.17mbar)
Complies with South Coast Air Quality Management District 40 ng/J or 55 ppm
NOx emission levels
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Ground / bottom - 12 inches (305mm)
From vent pipe - 0 inches
Back of heater - 0 inches
Ground / bottom - 12 inches (305mm)
From vent pipe - 0 inches
B
C
D
E
F
G
0.4~1.8 (10~45) Variable
14.04 (356.6)
22.95 (583)
9.27 (235.5)
5.05 (128.1)
2.67 (67.8)
A
DIMEN-
SION
Inches (mm)
DIMEN-
SION
Inches (mm)
A (GAS)
1.31 (33.2)
D
4.33 (110)
A (COLD)
1.93 (49)
E
2.89 (73.3)
A (HOT)
1.35 (34.4)
F
1.85 (47)
B
4.21 (106.9)
G
3.44 (87.3)
C
1.17 (29.8)
DIMENSIONS
WEIGHT: 46.3 lb (21.0 kg)
Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if
installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year
(* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water
heater is in series with a circulation system and all circulating water flows through the water heater)
Refer to the manual for complete warranty information.
Limited
Warranty
V94i (VC2837FFU-US)
  • Page 1 1
  • Page 2 2

Rinnai V94IP Specification

Type
Specification
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI