Savant SSC-002485-00 Deployment Guide

  • Hello! I am an AI chatbot trained to assist you with the Savant SSC-002485-00 Deployment Guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Copyright © 2020 Savant Systems LLC
-1-
45 Perseverance Way, Hyannis MA 02601
Savant.com | 508.683.2500
Document Number:
Document Date:
Document Supports:
009-1861-01
February 2020
da Vinci 9.1 and higher
Savant - Rollease Shade Motor and Controller Integration Guide
IMPORTANT! Before beginning integration of Rollease® shade systems with Savant, ensure successful communication between the Rollease shade motors
and shade hub, and confirm that the shade system is controllable from the Rollease Automate app. For details on initial Rollease setup, go to www.
rolleaseacmeda.com, select the region and then the AUTOMATE tab to search for and locate the required documents.
Savant - Rollease Shade Motor and Controller Integration Guide
2 of 7
Copyright © 2020 Savant Systems LLC
009-1861-01 | 200228
Contents
To access links to sections within this document, click the corresponding entry in the table of contents below.
1. Wiring ......................................................................................................................................................................................................................................... 3
2. Add Controllers to a Blueprint Configuration ............................................................................................................................................................. 4
2.1. Add Rollease Shade Motor Controller ................................................................................................................................................................... 4
2.2. Add Savant SSC-002485 Controller ...................................................................................................................................................................... 4
2.3. Add UID to Savant Controller ................................................................................................................................................................................... 5
2.4. Make Connections Between Controllers .............................................................................................................................................................. 5
2.5. Generate Services ......................................................................................................................................................................................................... 5
3. Create Data Table Entries ................................................................................................................................................................................................... 6
4. Save Configuration, Generate Services, and Upload Configuration ................................................................................................................... 7
Savant - Rollease Shade Motor and Controller Integration Guide
3 of 7
Copyright © 2020 Savant Systems LLC
009-1861-01 | 200228
1. Wiring
Use the diagram below when making connections between the Savant SSC-002485 controller and the Rollease controller.
Cut the RJ-45 connector o the supplied RJ-9 to RJ-45 cable and strip the jacketing back approximately
½ inch. Strip the black, yellow, and green
wires and install them into the 6-pin screw down terminal supplied with the SSC-002485 controller (6-pin screw terminal not shown in diagram). To
avoid wires from shorting, ensure that no more than
inch of bare wire protrudes from the rear of the 6-pin screw terminal (see diagram above).
Plug opposite end of cable (RJ-9) into the Rollease shade motor controller.
Connect a Cat 5e/6/7 cable between the Ethernet port on the SSC-002485 controller and a local network switch.
Apply power to both the SSC-002485 and Rollease controller (use supplied wall wart power supply).
Ethernet
12 VDC
Relay
GPIO
NC
NO
1C
/ /
NC
NO
2C
/ /
NC
NO
3C
/ /
G G
G A+ B- NC
TERM
RS485-1
1 2 3 4 5 6 7
G A+ B- NC
TERM
RS485-2
RS-485
Rollease Shade Motor Controller
Communicates with
Shade Motor using
the ARC protocol
SSC-002485 Controller
RJ9
Data
Cable
Signal GndBlack
Yellow
Green
+RS485
-RS485
Local Lan
6 pin screw
terminal not
shown
When connecting wires,
leave less than 1/8 inch
bare wire exposed
< 1/8 inch
bare wire
exposed
Savant - Rollease Shade Motor and Controller Integration Guide
4 of 7
Copyright © 2020 Savant Systems LLC
009-1861-01 | 200228
2. Add Controllers to a Blueprint Configuration
1. Open the Savant Application Manager (SAM) .
2. Through SAM, open a Blueprint configuration.
3. Select Show Library from the Blueprint toolbar. This opens the
Components library.
4. Enter rollease into the search bar (see image to the right).
5. Drag and drop the Rollease shade motor controller into a
Shared Equipment zone.
6. In the pop-up window that opens, enter a unique name that
identifies the controller (image not shown).
7. Select Create to add the controller to the Blueprint
configuration (image not shown).
8. Drag the Rollease controller from the component list to the
layout window.
1. Select the Component Library again.
2. Enter SSC-002485 into the Search bar (see image to the right).
3. Drag and drop the controller into a Shared Equipment zone.
4. Enter a unique name that identifies the controller in the pop-up
window that opens.
5. Select Create to add the controller to the Blueprint
configuration (image not shown).
6. Drag the Savant controller from the component list to the
layout window.
Components
?
All Components
Enter SSC-002485
All Manufacturers All Control Types
CommentComponents
1
RatingTL
SmartControl 002485
Savant
“ ”
SSC-002485
Components
?
All Components
Enter rollease
All Manufacturers All Control Types
CommentComponents
1
RatingTL
Automate Pulse Hub [RS232, RS422]
Rollease Acmeda
“ ”
rollease
To add a service for the Rollease shade motor system to the Savant user interface, both the Rollease shade motor controller and the Savant SSC-002485
controller must be added to a RacePoint Blueprint configuration and then uploaded to the Savant Host. The instructions below describe how to add these
controllers and make the required connections.
2.1. Add Rollease Shade Motor Controller
2.2. Add Savant SSC-002485 Controller
Savant - Rollease Shade Motor and Controller Integration Guide
5 of 7
Copyright © 2020 Savant Systems LLC
009-1861-01 | 200228
1. Right-click the Ethernet port on the SSC-002485 and
make connection to a network switch.
2. Right-click one of the RS-485 ports on the SSC-002485
and make connection to the RS-485 port on the
Rollease shade motor controller.
1. Double-click the SSC-002485 to open Inspector.
2. Enter the UID of the SSC-002485 controller into the
Savant UID field.
3. Close Inspector once UID is entered.
HELPFUL! The UID is a 16 character number that the Host
uses to identify the controller. The UID is listed on a
label attached to the bottom of the controller
SSC-002485
Control Ports
RS485 1
Network (Ethernet)
Data
Assigned Data
Network Device
Ethernet Port (Ethernet)
Ethernet Port (Ethernet)
Ethernet Port (Ethernet)
Port 1
Port 2
Port 3
Ethernet Port (Ethernet)
Port 4
Rollease_Shade_Controller
Control Ports
RS232 to RS485 Adapter
RS485
?
?
OPTIONAL: Connection Not Required
2.3. Add UID to Savant Controller
2.4. Make Connections Between Controllers
2.5. Generate Services
Inspecting “SSC_002485”
Edit
D 1.5
Device
Screens
Hide Details
Class: Savant Extender
Add Savant
Unique ID
Manufacturer: Savant
Model: SmartControl 002485
Device Name:
Savant UID:
Notes:
?
SCC_002485
001AAE0003880028
The next section adds shade motors to the Blueprint configuration by adding the motors directly into the shade data table. To do this, the shade
service must first be generated. From the Blueprint toolbar, select Generate Services. The state icon on the Blueprint toolbar will change to either
blue or green. Once Blueprint is in one of these two states, the data table can be modified.
Savant - Rollease Shade Motor and Controller Integration Guide
6 of 7
Copyright © 2020 Savant Systems LLC
009-1861-01 | 200228
3. Create Data Table Entries
Each Rollease shade motor must be added to the Shade Data Table with Blueprint. To access the data table, select Tools > Settings > Shades from the
Blueprint menu bar. To add each entry, do the following:
1. Select the add button
+
.
2. Using the descriptions in the table below, make the required changes to each entry. Each entry corresponds to a shade motor.
3. Select Done once all shade motors have been added.
Shades Settings
Enabled Identifier Location
Master Bed Shade 1
005
Controller Entity
Label
Entity
Show Advanced Columns
Savant App Zone Map
TrueControl Zone Map
Regenerate AllEnable All
Disable All
+
0
Rollease_Shade_Controller Master Bedroom Single Motor Variable Shade
Done
ExportImport
Cancel
Address [2] Address [3] Address [4] Address [5]Address [1]
?
Select + to add an entry to the data table
Field Description (Standard)
Enabled
When checked, the entry (row) is displayed and can be controlled from the Savant user interface.
When unchecked, the entry is not shown in the UI.
Identifier Used by the Host to identify each shade motor. The identifier is automatically populated and can't be changed.
Controller For Rollease shade system, select the Rollease shade motor controller added in section 2.1 above.
Location
Select a Savant zone from the drop-down, or enter a custom location for the shade motor. Note that if using a custom location, the
Savant App Zone Map and/or TrueControl Zone Map must be used to enable the entry in the desired room(s).
Entity
Select Single Motor Variable Shade from the drop-down for all Rollease shades. This entity type adds a slider to the Savant UI that
controls the shade position and movement.
Label Enter a label that identifies the shade. The text entered is displayed next to the button/slider in the Savant UI shade control screen.
Address [1]
Enter the address of the shade motor. The address of each motor is available in the AUTOMATE App. Follow the steps below to locate
the address of each motor. The steps assume the AUTOMATE app is installed on a mobile device and the shade motors have been
discovered and paired with the Rollease shade motor controller.
1. Open the AUTOMATE app.
2. Select the DEVICES tab.
3. Select the shade motor that corresponds to the entry in the Blueprint data table.
4. Select Edit at the top right corner of the SHADE screen.
5. Copy the address listed for the shade motor (SERIAL ADDRESS field), into the Blueprint data table Address 1 field. All
addressing must be entered as a 3-digit number. For example, 5 would be entered as 005, and 12 would be entered as 012.
Savant - Rollease Shade Motor and Controller Integration Guide
7 of 7
Copyright © 2020 Savant Systems LLC
009-1861-01 | 200228
4. Save Configuration, Generate Services, and Upload Configuration
With the controllers added to a Blueprint configuration and the shade data table complete. Follow instructions below to update the services, save, and
upload to the Savant Host.
1. Select Generate Services from the Blueprint toolbar to update realized services with changes made to the configuration. If using TrueControl II
interfaces within the config, select Update All UI Screens to sync with services. The State Icon will change to Green indicating that shade service was
updated with each shade motor and controller added from the previous section.
2. To upload, select the Upload to Master icon in the Blueprint tool bar. See image below.
3. In the Configuration must be saved dialog box that opens, read the dialog and select Save and Upload.
4. The System Monitor application will open as shown below. Verify the path to the Blueprint configuration file is correct. If not, select Browse and locate
the file on your local drive (SDE/MacBook). Select Upload when satisfied and the configuration will upload to the Host.
Select the Upload to Master Icon
Scanner
toNetwork Range
>
>
10.10.0.1 Search
10.10.0.255
Device Name System Name Device Type IP Address OS Version Savant Unique ID Redundancy
Smith Residence
Smith Residence Host 10.10.229.134 8.9.1 10DDB1C60190020 Standalone
1 result
/Users/savant.user/documents/configs
Sync themes
Pre-extract UIs
Browse
Cancel
Edit UIDs
Upload
/