Kubota KF-C3000 Calibration Manual

  • Hello! I am an AI chatbot trained to assist you with the Kubota KF-C3000 Calibration Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
KUBOTA CONVEYOR SCALE
CALIBRATION MANUAL
Model: KF-C3000
Controller
SAMBO Corporation
Tel : 02-866-3125 Fax : 02-866-3129 E-mail : [email protected] Home Page : http://www.sbcorp.co.kr
#503 Kolon Techno Valley, 60-4 Kasan-Dong, Kumchon-Gu, Seoul, Korea
KFC3-1.00-0
1. Operation Screen Display
2. How to set Parameter
1) The screen like below display 2) By pressing key, move to parameter
when pressing key setting screen
in operation screen
☞ When you select a menu, press a number
1/5
This display mode of Controller.
This display as load rate % a
material loaded in weighing section
on Belt
This display as value(t/h) the
quantity passing through a belt now.
This display accumulated integrated
guantity
This display setting LINE number
'[01]' and internal memory number '
3) Parameter display when pressing key .
4) When you change parameter ,press key, then white input window
will display in bottom line.
when input window display,press a number and key,
it will go to desired parameter
Ex)When parameter 43'setting value want
change to 0.152221
After confirming cursor is located in [No.],
→ → →
→ →
enter the above order.
☞ After parameter change is finished, press key,
operation screen will display.
2/5
parameter
number
parameter setting value
& unit
explanation for
parameter & setting
Blue shaded area is cursor..
Press key to move down ,change the
setting value.
If press key while the cursor is located,
input
window display and you can input a value..
3. CALIBRATION
1) In operation screen, when you press key, below screen will display.
1-1) Integrated Zero Adjustment
It will start when belt is on
No-load state.
① Start belt in No-load state.
② When the belt operated at a steady rate,
press key , and Integrated Zero
adjustment start.
③ When it arrives a standard pulse, Controller
stop calculating automatically.
④ If you press the key after
calculating, integrated Zero value is inputted.
⑤ After doing once more ①~③ ,
when Integrated Zero value is in scope
of ±0.12%,
adjustment is finished.
press key to go former screen.
3/5
press key to go to former screen.
press key to go to Integrated Span
adjustment screen.
1-2) Integrated Span adjustment
After raising a weight to start,
go start.
① After raising a weight, start a belt.
② When the belt operated at a steady rate,
please check the cursor is located in Span
location. And If you press key,
Integrated Span adjustment will be started.
④ On adjustment ,integrated value is
displayed in 'Cal 1',
present Pulse value is displayed in 'Cal 3'
⑤ When it arrives a standard pulse, Controller
stop calculating automatically.
new calculated Span value is displayed in'Cal 3'
press key,new calculated Span value
is inputted.
⑥ After doing 3 times a ①~⑤, when average value is in scope of ±0.25%,
adjustment is finished.
note) Adjustment is completed, you don’t need to press ,
press key, and confirm Integrated value
4/5
4. Error revision
* Need error revision for after material feed
1) By changing parameter No.43, a error can be revised.
Ex) In case real quantity- 100.00 ton, indication value - 99.45 ton ,
Now SPAN(P.43's value) x real quantity (100.00) / indication value (99.45) =
-> 0.151384 x 100.00 / 99.45 = 0.152221
input 0.152221 in P43, and revised
☞ After changing a parameter,press key to go to operation screen.
5/5
parameter Number
parameter setting value
& unit
explanation for