Netgear XSM7224S User manual

Category
Software
Type
User manual
202-10770-01
November 2010
NETGEAR, Inc.
350 Plumeria Dr.
San Jose, CA 95124 USA
ProSafe XSM7224S
Managed Stackable
Switch CLI Manual,
Software Version 9.0
ii
v1.0, November 2010
© 2010 by NETGEAR, Inc. All rights reserved.
Trademarks
NETGEAR and the NETGEAR logo are registered trademarks, and ProSafe is a trademark of NETGEAR, Inc.
Microsoft, Windows, and Windows NT are registered trademarks of Microsoft Corporation.
Other brand and product names are registered trademarks or trademarks of their respective holders. Portions of this
document are copyright Intoto, Inc.
November 2010
Statement of Conditions
In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves the right to
make changes to the products described in this document without notice.
NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or circuit
layout(s) described herein.
EN 55 022 Declaration of Conformance
This is to certify that the ProSafe XSM7224S Managed Stackable Switch is shielded against the generation of radio
interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by
the application of EN 55 022 Class B (CISPR 22).
Certificate of the Manufacturer/Importer
It is hereby certified that the ProSafe XSM7224S Managed Stackable Switch has been suppressed in accordance with the
conditions set out in the BMPT-AmtsblVfg 243/1991 and Vfg 46/1992. The operation of some equipment (for example,
test transmitters) in accordance with the regulations may, however, be subject to certain restrictions. Please refer to the
notes in the operating instructions.
The Federal Office for Telecommunications Approvals has been notified of the placing of this equipment on the market
and has been granted the right to test the series for compliance with the regulations.
Bestätigung des Herstellers/Importeurs
Es wird hiermit bestätigt, daß dasProSafe XSM7224S Managed Stackable Switch gemäß der im BMPT-AmtsblVfg 243/
1991 und Vfg 46/1992 aufgeführten Bestimmungen entstört ist. Das vorschriftsmäßige Betreiben einiger Geräte (z.B.
Testsender) kann jedoch gewissen Beschränkungen unterliegen. Lesen Sie dazu bitte die Anmerkungen in der
Betriebsanleitung.
Das Bundesamt für Zulassungen in der Telekommunikation wurde davon unterrichtet, daß dieses Gerät auf den Markt
gebracht wurde und es ist berechtigt, die Serie auf die Erfüllung der Vorschriften hin zu überprüfen.
Voluntary Control Council for Interference (VCCI) Statement
This equipment is in the Class B category (information equipment to be used in a residential area or an adjacent area
thereto) and conforms to the standards set by the Voluntary Control Council for Interference by Data Processing
Equipment and Electronic Office Machines aimed at preventing radio interference in such residential areas. When used
near a radio or TV receiver, it may become the cause of radio interference. Read instructions for correct handling.
v1.0, November 2010
iii
Product and Publication Details
Model Number: XSM7224S
Publication Date: November 2010
Product Family: managed switch
Product Name: ProSafe XSM7224S Managed Stackable Switch
Home or Business Product: Business
Language: English
Publication Part Number: 202-10770-01
Publication Version Number 1.0
v1.0, November 2010
iv
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
v
v1.0, November 2010
Contents
About This Manual
Audience ...........................................................................................................................ix
About the Software ........................................................................................................... ix
Scope.......................................................................................................................... x
Product Concept ......................................................................................................... x
Chapter 1
Using the Command-Line Interface
Command Syntax ...........................................................................................................1-1
Command Conventions ..................................................................................................1-2
Common Parameter Values ...........................................................................................1-3
Unit/Slot/Port Naming Convention ..................................................................................1-3
Using the “No” Form of a Command ..............................................................................1-4
Managed Switch Modules ..............................................................................................1-5
Command Modes ...........................................................................................................1-5
Command Completion and Abbreviation ........................................................................1-9
CLI Error Messages ........................................................................................................1-9
CLI Line-Editing Conventions .......................................................................................1-10
Using CLI Help .............................................................................................................1-11
Accessing the CLI .........................................................................................................1-12
Chapter 2
Stacking Commands
Dedicated Port Stacking .................................................................................................2-1
Front Panel Stacking Commands .................................................................................2-10
Non-Stop Forwarding Commands ................................................................................2-12
Stack Firmware Synchronization Commands ...............................................................2-14
Chapter 3
Switching Commands
Port Configuration Commands .......................................................................................3-2
Spanning Tree Protocol (STP) Commands ..................................................................3-11
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
vi
v1.0, November 2010
VLAN Commands .........................................................................................................3-32
Double VLAN Commands ............................................................................................3-47
Voice VLAN Commands ...............................................................................................3-50
Provisioning (IEEE 802.1p) Commands .......................................................................3-52
Protected Ports Commands .........................................................................................3-53
Private Group Commands ............................................................................................3-56
GARP Commands ........................................................................................................3-58
GVRP Commands ........................................................................................................3-61
GMRP Commands .......................................................................................................3-63
Port-Based Network Access Control Commands .........................................................3-66
Storm-Control Commands ............................................................................................3-82
Port-Channel/LAG (802.3ad) Commands ....................................................................3-94
Port Mirroring ..............................................................................................................3-115
Static MAC Filtering ....................................................................................................3-118
DHCP Snooping Configuration Commands ...............................................................3-123
Dynamic ARP Inspection Commands ........................................................................3-134
IGMP Snooping Configuration Commands ................................................................3-142
IGMP Snooping Querier Commands ..........................................................................3-151
Port Security Commands ............................................................................................3-157
LLDP (802.1AB) Commands ......................................................................................3-161
LLDP-MED Commands ..............................................................................................3-172
Denial of Service Commands .....................................................................................3-183
MAC Database Commands ........................................................................................3-195
ISDP Commands ........................................................................................................3-197
Priority-Based Flow control commands ......................................................................3-203
Chapter 4
Routing Commands
Address Resolution Protocol (ARP) Commands ............................................................4-1
IP Routing Commands ...................................................................................................4-8
Virtual LAN Routing Commands ...................................................................................4-20
DHCP and BOOTP Relay Commands .........................................................................4-21
IP Helper Commands ...................................................................................................4-24
ICMP Throttling Commands .........................................................................................4-26
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
vii
v1.0, November 2010
Chapter 5
Quality of Service (QoS) Commands
Class of Service (CoS) Commands ................................................................................5-2
Differentiated Services (DiffServ) Commands ................................................................5-9
DiffServ Class Commands ...........................................................................................5-11
DiffServ Policy Commands ...........................................................................................5-20
DiffServ Service Commands ........................................................................................5-25
DiffServ Show Commands ...........................................................................................5-27
MAC Access Control List (ACL) Commands ................................................................5-33
IP Access Control List (ACL) Commands .....................................................................5-38
IPv6 Access Control List (ACL) Commands .................................................................5-45
Auto-Voice over IP Commands ....................................................................................5-49
Chapter 6
Utility Commands
Auto Install Commands ..................................................................................................6-2
Dual Image Commands ..................................................................................................6-4
System Information and Statistics Commands ...............................................................6-6
Logging Commands .....................................................................................................6-18
System Utility and Clear Commands ............................................................................6-23
Simple Network Time Protocol (SNTP) Commands .....................................................6-33
DHCP Server Commands ............................................................................................6-40
DNS Client Commands ................................................................................................6-54
Packet Capture Commands .........................................................................................6-60
Serviceability Packet Tracing Commands ....................................................................6-62
Cable Test Command ...................................................................................................6-82
sFlow Commands .........................................................................................................6-83
Software License Commands .......................................................................................6-88
IP Address Conflict Commands ....................................................................................6-90
Link Local Protocol Filtering Commands ......................................................................6-91
Chapter 7
Management Commands
Configuring the Switch Management CPU .....................................................................7-2
Network Interface Commands ........................................................................................7-4
Console Port Access Commands ...................................................................................7-8
Telnet Commands ........................................................................................................7-11
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
viii
v1.0, November 2010
Secure Shell (SSH) Commands ...................................................................................7-16
Management Security Commands ...............................................................................7-19
Hypertext Transfer Protocol (HTTP) Commands .........................................................7-20
Access Commands .......................................................................................................7-28
User Account Commands .............................................................................................7-29
SNMP Commands ........................................................................................................7-47
RADIUS Commands .....................................................................................................7-59
TACACS+ Commands ..................................................................................................7-73
Configuration Scripting Commands ..............................................................................7-77
Pre-login Banner and System Prompt Commands .......................................................7-79
Switch Database Management (SDM) Templates .......................................................7-80
Chapter 8
Log Messages
Core ................................................................................................................................8-1
Utilities ............................................................................................................................8-4
Management ...................................................................................................................8-6
Switching ......................................................................................................................8-10
QoS ..............................................................................................................................8-16
Routing/IPv6 Routing ....................................................................................................8-17
Multicast .......................................................................................................................8-21
Stacking ........................................................................................................................8-23
Technologies ................................................................................................................8-23
O/S Support ..................................................................................................................8-26
Chapter 9
Captive Portal Commands
Captive Portal Global Commands ..................................................................................9-1
Captive Portal Configuration Commands .......................................................................9-5
Captive Portal Status Commands ................................................................................9-14
Captive Portal Client Connection Commands ..............................................................9-19
Captive Portal Interface Commands .............................................................................9-23
Captive Portal Local User Commands .........................................................................9-24
Captive Portal User Group Commands ........................................................................9-31
Chapter 10
Command List
ix
v1.0, November 2010
About This Manual
This document describes command-line interface (CLI) commands you use to view and configure
XSM7224S software. You can access the CLI by using a direct connection to the serial port or by
using telnet or SSH over a remote network connection.
Audience
This document is for system administrators who configure and operate systems using XSM7224S
software. It provides an understanding of the configuration options of the software.
Software engineers who integrate software into their hardware platform can also benefit from a
description of the configuration options.
This document assumes that the reader has an understanding of the software base and has read the
appropriate specification for the relevant networking device platform. It also assumes that the
reader has a basic knowledge of Ethernet and networking concepts.
Refer to the release notes for the application-level code. The release notes detail the platform-
specific functionality of the Switching, Routing, SNMP, Configuration, Management, and other
packages. The suite of features the packages support is not available on all the platforms to which
software has been ported.
About the Software
The software has two purposes:
Assist attached hardware in switching frames, based on Layer 2, 3, or 4 information contained
in the frames.
Provide a complete device management portfolio to the network administrator.
Note: This document contains both standalone and stacking commands.
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
x
v1.0, November 2010
Scope
The software encompasses both hardware and software support. The software is partitioned to run
in the following processors:
CPU – This code runs the networking device management portfolio and controls the overall
networking device hardware. It also assists in frame forwarding, as needed and specified. This
code is designed to run on multiple platforms with minimal changes from platform to
platform.
Networking device processor – This code does the majority of the packet switching, usually at
wire speed. This code is platform dependent, and substantial changes might exist across
products.
Product Concept
Fast Ethernet and Gigabit Ethernet switching continues to evolve from high-end backbone
applications to desktop switching applications. The price of the technology continues to decline,
while performance and feature sets continue to improve. Devices that are capable of switching
Layers 2, 3, and 4 are increasingly in demand. The software provides a flexible solution to these
ever-increasing needs.
The exact functionality provided by each networking device on which the software base runs
varies depending upon the platform and requirements of the FASTPATH software.
The software includes a set of comprehensive management functions for managing both the
software and the network. You can manage the software by using one of the following three
methods:
Command-Line Interface (CLI)
Simple Network Management Protocol (SNMP)
Web-based
Each of the management methods enables you to configure, manage, and control the software
locally or remotely using in-band or out-of-band mechanisms. Management is standards-based,
with configuration parameters and a private MIB providing control for functions not completely
specified in the MIBs.
Conventions, Formats, and Scope
The conventions, formats, and scope of this manual are described in the following paragraphs:
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
xi
v1.0, November 2010
Typographical Conventions. This manual uses the following typographical conventions:
Formats. This manual uses the following formats to highlight special messages:
Scope. This manual is written for the XSM7224S.
Italic Emphasis, books, CDs, file and server names, extensions
Bold User input, IP addresses, GUI screen text
Fixed Command prompt, CLI text, code
italic URL links
Note: This format is used to highlight information of importance or special interest.
Tip: This format is used to highlight a procedure that will save time or resources.
Warning: Ignoring this type of note may result in a malfunction or damage to the
equipment.
Danger: This is a safety warning. Failure to take heed of this notice may result in
personal injury or death.
Product Version ProSafe XSM7224S Managed Stackable Switch
Manual Publication Date November 2010
Note: Product updates are available on the NETGEAR, Inc. website at
http://kbserver.netgear.com
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
xii
v1.0, November 2010
How to Print This Manual
To print this manual, your computer must have the free Adobe Acrobat reader installed in order to
view and print PDF files. The Acrobat reader is available on the Adobe Web site at
http://www.adobe.com.
Revision History
Part Number
Version
Number
Date Description
202-10770-01 1.0 November 2010 Product update: New firmware and new user Interface
1-1
v1.0, November 2010
Chapter 1
Using the Command-Line Interface
The command-line interface (CLI) is a text-based way to manage and monitor the system. You can
access the CLI by using a direct serial connection or by using a remote logical connection with
telnet or SSH.
This chapter describes the CLI syntax, conventions, and modes. It contains the following sections:
“Command Syntax” on page 1-1
“Command Conventions” on page 1-2
“Common Parameter Values” on page 1-3
“Unit/Slot/Port Naming Convention” on page 1-3
“Using the “No” Form of a Command” on page 1-4
“Managed Switch Modules” on page 1-5
“Command Modes” on page 1-5
“Command Completion and Abbreviation” on page 1-9
“CLI Error Messages” on page 1-9
“CLI Line-Editing Conventions” on page 1-10
“Using CLI Help” on page 1-11
“Accessing the CLI” on page 1-12
Command Syntax
A command is one or more words that might be followed by one or more parameters. Parameters
can be required or optional values.
Some commands, such as show network or clear vlan, do not require parameters. Other
commands, such as network parms, require that you supply a value after the command. You
must type the parameter values in a specific order, and optional parameters follow required
parameters. The following example describes the network parms command syntax:
Format network parms <ipaddr> <netmask> [gateway]
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
Using the Command-Line Interface 1-2
v1.0, November 2010
network parms is the command name.
<ipaddr> and <netmask> are parameters and represent required values that you must
enter after you type the command keywords.
[gateway] is an optional parameter, so you are not required to enter a value in place of the
parameter.
The CLI Command Reference lists each command by the command name and provides a brief
description of the command. Each command reference also contains the following information:
Format shows the command keywords and the required and optional parameters.
Mode identifies the command mode you must be in to access the command.
Default shows the default value, if any, of a configurable setting on the device.
The show commands also contain a description of the information that the command shows.
Command Conventions
In this document, the command name is in bold font. Parameters are in italic font. You
must replace the parameter name with an appropriate value, which might be a name or number.
Parameters are order dependent.
The parameters for a command might include mandatory values, optional values, or keyword
choices. Table 1 describes the conventions this document uses to distinguish between value types.
Table 1. Parameter Conventions
Symbol Example Description
<> angle brackets <value> Indicates that you must enter a value in place of the
brackets and text inside them.
[] square brackets [value] Indicates an optional parameter that you can enter in
place of the brackets and text inside them.
{} curly braces {choice1 |
choice2}
Indicates that you must select a parameter from the list of
choices.
| Vertical bars choice1 | choice2 Separates the mutually exclusive choices.
[{}] Braces within
square brackets
[{choice1 |
choice2}]
Indicates a choice within an optional element.
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
Using the Command-Line Interface 1-3
v1.0, November 2010
Common Parameter Values
Parameter values might be names (strings) or numbers.To use spaces as part of a name parameter,
enclose the name value in double quotes. For example, the expression “System Name with
Spaces” forces the system to accept the spaces. Empty strings (““) are not valid user-defined
strings. Table 2 describes common parameter values and value formatting.
Unit/Slot/Port Naming Convention
Managed switch software references physical entities such as cards and ports by using a unit/slot/
port naming convention. The software also uses this convention to identify certain logical entities,
such as Port-Channel interfaces.
Table 2. Parameter Descriptions
Parameter Description
ipaddr This parameter is a valid IP address. You can enter the IP address in the following
formats:
a (32 bits)
a.b (8.24 bits)
a.b.c (8.8.16 bits)
a.b.c.d (8.8.8.8)
In addition to these formats, the CLI accepts decimal, hexadecimal and octal formats
through the following input formats (where n is any valid hexadecimal, octal or decimal
number):
0xn (CLI assumes hexadecimal format)
0n (CLI assumes octal format with leading zeros)
n (CLI assumes decimal format)
ipv6-address FE80:0000:0000:0000:020F:24FF:FEBF:DBCB, or
FE80:0:0:0:20F:24FF:FEBF:DBCB, or
FE80::20F24FF:FEBF:DBCB, or
FE80:0:0:0:20F:24FF:128:141:49:32
For additional information, refer to RFC 3513.
Interface or
unit/slot/port
Valid slot and port number separated by forward slashes. For example, 0/1 represents
slot number 0 and port number 1.
Logical Interface Represents a logical slot and port number. This is applicable in the case of a port-
channel (LAG). You can use the logical unit/slot/port to configure the port-channel.
Character strings Use double quotation marks to identify character strings, for example, “System Name
with Spaces”. An empty string (“”) is not valid.
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
Using the Command-Line Interface 1-4
v1.0, November 2010
The slot number has two uses. In the case of physical ports, it identifies the card containing the
ports. In the case of logical and CPU ports it also identifies the type of interface or port.
The port identifies the specific physical port or logical interface being managed on a given slot.
Using the “No” Form of a Command
The no keyword is a specific form of an existing command and does not represent a new or
distinct command. Almost every configuration command has a no form. In general, use the no
form to reverse the action of a command or reset a value back to the default. For example, the no
Table 3. Type of Slots
Slot Type Description
Physical slot numbers Physical slot numbers begin with zero, and are allocated up to the maximum
number of physical slots.
Logical slot numbers Logical slots immediately follow physical slots and identify port-channel (LAG) or
router interfaces.
CPU slot numbers The CPU slots immediately follow the logical slots.
Table 4. Type of Ports
Port Type Description
Physical Ports The physical ports for each slot are numbered sequentially starting from zero.
Logical Interfaces Port-channel or Link Aggregation Group (LAG) interfaces are logical interfaces
that are only used for bridging functions.
VLAN routing interfaces are only used for routing functions.
Loopback interfaces are logical interfaces that are always up.
Tunnel interfaces are logical point-to-point links that carry encapsulated packets.
CPU ports CPU ports are handled by the driver as one or more physical entities located on
physical slots.
Note: In the CLI, loopback and tunnel interfaces do not use the unit/slot/port format. To
specify a loopback interface, you use the loopback ID. To specify a tunnel
interface, you use the tunnel ID.
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
Using the Command-Line Interface 1-5
v1.0, November 2010
shutdown configuration command reverses the shutdown of an interface. Use the command
without the keyword no to re-enable a disabled feature or to enable a feature that is disabled by
default. Only the configuration commands are available in the no form.
Managed Switch Modules
Managed switch software consists of flexible modules that can be applied in various combinations
to develop advanced Layer 2/3/4+ products. The commands and command modes available on
your switch depend on the installed modules. Additionally, for some show commands, the output
fields might change based on the modules included in the software.
The software suite includes the following modules:
Switching (Layer 2)
Quality of Service
Management (CLI, Web UI, and SNMP)
IPv6 Management—Allows management of the device through an IPv6 through an IPv6
address without requiring the IPv6 Routing package in the system. The management address
can be associated with the network port (front-panel switch ports), a routine interface (port or
VLAN) and the Service port.
Stacking
Not all modules are available for all platforms or software releases.
Command Modes
The CLI groups commands into modes according to the command function. Each of the command
modes supports specific software commands. The commands in one mode are not available until
you switch to that particular mode, with the exception of the User EXEC mode commands. You
can execute the User EXEC mode commands in the Privileged EXEC mode.
The command prompt changes in each command mode to help you identify the current mode.
Table 5 describes the command modes and the prompts visible in that mode.
Note: The command modes available on your switch depend on the software modules
that are installed. For example, a switch that does not support BGPv4 does not have
the Router BGPv4 Command Mode.
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
Using the Command-Line Interface 1-6
v1.0, November 2010
Table 5. CLI Command Modes
Command Mode Prompt Mode Description
User EXEC Switch> Contains a limited set of commands to view
basic system information.
Privileged EXEC Switch# Allows you to issue any EXEC command, enter
the VLAN mode, or enter the Global
Configuration mode.
Global Config Switch (Config)# Groups general setup commands and permits
you to make modifications to the running
configuration.
VLAN Config Switch (Vlan)# Groups all the VLAN commands.
Interface Config Switch (Interface <unit/slot/port>)#
Switch (Interface Loopback <id>)#
Switch (Interface Tunnel <id>)#
Manages the operation of an interface and
provides access to the router interface
configuration commands.
Use this mode to set up a physical port for a
specific logical connection operation.
Line Config Switch (line)# Contains commands to configure outbound
telnet settings and console interface settings.
Policy Map
Config
Switch (Config-policy-map)# Contains the QoS Policy-Map configuration
commands.
Policy Class
Config
Switch (Config-policy-class-map)# Consists of class creation, deletion, and
matching commands. The class match
commands specify Layer 2, Layer 3, and
general match criteria.
Class Map Config Switch (Config-class-map)# Contains the QoS class map configuration
commands for IPv4.
Ipv6_Class-Map
Config
Switch (Config-class-map)# Contains the QoS class map configuration
commands for IPv6.
Router OSPF
Config
Switch (Config-router)# Contains the OSPF configuration commands.
Router OSPFv3
Config
Switch (Config rtr)# Contains the OSPFv3 configuration commands.
Router RIP Config Switch (Config-router)# Contains the RIP configuration commands.
Router BGP
Config
Switch (Config-router)# Contains the BGP4 configuration commands.
MAC Access-list
Config
Switch (Config-mac-access-list)# Allows you to create a MAC Access-List and to
enter the mode containing MAC Access-List
configuration commands.
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
Using the Command-Line Interface 1-7
v1.0, November 2010
Table 6 explains how to enter or exit each mode.
TACACS Config Switch (Tacacs)# Contains commands to configure properties for
the TACACS servers.
DHCP Pool
Config
Switch (Config dhcp-pool)# Contains the DHCP server IP address pool
configuration commands.
DHCPv6 Pool
Config
Switch (Config dhcp6-pool)# Contains the DHCPv6 server IPv6 address pool
configuration commands.
Stack Global
Config Mode
Switch (Config stack)# Allows you to access the Stack Global Config
Mode.
ARP Access-List
Config Mode
Switch (Config-arp-access-list)# Contains commands to add ARP ACL rules in
an ARP Access List.
Table 6. CLI Mode Access and Exit
Command Mode Access Method Exit or Access Previous Mode
User EXEC This is the first level of access. To exit, enter logout.
Privileged EXEC From the User EXEC mode, enter
enable.
To exit to the User EXEC mode, enter exit or
press Ctrl-Z.
Global Config From the Privileged EXEC mode,
enter configure.
To exit to the Privileged EXEC mode, enter exit,
or press Ctrl-Z.
VLAN Config From the Privileged EXEC mode,
enter vlan database.
To exit to the Privileged EXEC mode, enter exit,
or press Ctrl-Z.
Interface Config From the Global Config mode,
enter
interface <unit/slot/port>
or interface loopback <id>
or interface tunnel <id>
To exit to the Global Config mode, enter exit. To
return to the Privileged EXEC mode, enter Ctrl-
Z.
Line Config From the Global Config mode,
enter
lineconfig.
To exit to the Global Config mode, enter exit. To
return to the Privileged EXEC mode, enter Ctrl-
Z.
Policy-Map
Config
From the Global Config mode,
enter
policy-map <name> in.
To exit to the Global Config mode, enter exit. To
return to the Privileged EXEC mode, enter Ctrl-
Z.
Policy-Class-Map
Config
From the Policy Map mode enter
class.
To exit to the Policy Map mode, enter exit. To
return to the Privileged EXEC mode, enter Ctrl-
Z.
Table 5. CLI Command Modes (continued)
Command Mode Prompt Mode Description
ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0
Using the Command-Line Interface 1-8
v1.0, November 2010
Class-Map
Config
From the Global Config mode,
enter
class-map, and specify the
optional keyword ipv4 to specify
the Layer 3 protocol for this class.
See “class-map” on page 5-12 for
more information.
To exit to the Global Config mode, enter exit. To
return to the Privileged EXEC mode, enter Ctrl-
Z.
Ipv6-Class-Map
Config
From the Global Config mode,
enter
class-map and specify the
optional keyword ipv6 to specify
the Layer 3 protocol for this class.
See “class-map” on page 5-12 for
more information.
To exit to the Global Config mode, enter exit. To
return to the Privileged EXEC mode, enter Ctrl-
Z.
Router OSPF
Config
From the Global Config mode,
enter
router ospf.
To exit to the Global Config mode, enter exit. To
return to the Privileged EXEC mode, enter Ctrl-
Z.
Router OSPFv3
Config
From the Global Config mode,
enter
ipv6 router ospf.
To exit to the Global Config mode, enter exit. To
return to the Privileged EXEC mode, enter Ctrl-
Z.
Router RIP
Config
From the Global Config mode,
enter
router rip.
To exit to the Global Config mode, enter exit. To
return to the Privileged EXEC mode, enter Ctrl-
Z.
Router BGP
Config
From the Global Config mode,
enter
router bgp <asnumber>.
To exit to the Global Config mode, enter exit. To
return to the Privileged EXEC mode, enter Ctrl-
Z.
MAC Access-list
Config
From the Global Config mode,
enter
mac access-list extended
<name>.
To exit to the Global Config mode, enter exit. To
return to the Privileged EXEC mode, enter Ctrl-
Z.
TACACS Config From the Global Config mode,
enter
tacacs-server host
<ip-addr>, where <ip-addr> is
the IP address of the TACACS
server on your network.
To exit to the Global Config mode, enter exit. To
return to the Privileged EXEC mode, enter Ctrl-
Z.
DHCP Pool
Config
From the Global Config mode,
enter
ip dhcp pool <pool-name>.
To exit to the Global Config mode, enter exit. To
return to the Privileged EXEC mode, enter Ctrl-
Z.
Table 6. CLI Mode Access and Exit (continued)
Command Mode Access Method Exit or Access Previous Mode
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342
  • Page 343 343
  • Page 344 344
  • Page 345 345
  • Page 346 346
  • Page 347 347
  • Page 348 348
  • Page 349 349
  • Page 350 350
  • Page 351 351
  • Page 352 352
  • Page 353 353
  • Page 354 354
  • Page 355 355
  • Page 356 356
  • Page 357 357
  • Page 358 358
  • Page 359 359
  • Page 360 360
  • Page 361 361
  • Page 362 362
  • Page 363 363
  • Page 364 364
  • Page 365 365
  • Page 366 366
  • Page 367 367
  • Page 368 368
  • Page 369 369
  • Page 370 370
  • Page 371 371
  • Page 372 372
  • Page 373 373
  • Page 374 374
  • Page 375 375
  • Page 376 376
  • Page 377 377
  • Page 378 378
  • Page 379 379
  • Page 380 380
  • Page 381 381
  • Page 382 382
  • Page 383 383
  • Page 384 384
  • Page 385 385
  • Page 386 386
  • Page 387 387
  • Page 388 388
  • Page 389 389
  • Page 390 390
  • Page 391 391
  • Page 392 392
  • Page 393 393
  • Page 394 394
  • Page 395 395
  • Page 396 396
  • Page 397 397
  • Page 398 398
  • Page 399 399
  • Page 400 400
  • Page 401 401
  • Page 402 402
  • Page 403 403
  • Page 404 404
  • Page 405 405
  • Page 406 406
  • Page 407 407
  • Page 408 408
  • Page 409 409
  • Page 410 410
  • Page 411 411
  • Page 412 412
  • Page 413 413
  • Page 414 414
  • Page 415 415
  • Page 416 416
  • Page 417 417
  • Page 418 418
  • Page 419 419
  • Page 420 420
  • Page 421 421
  • Page 422 422
  • Page 423 423
  • Page 424 424
  • Page 425 425
  • Page 426 426
  • Page 427 427
  • Page 428 428
  • Page 429 429
  • Page 430 430
  • Page 431 431
  • Page 432 432
  • Page 433 433
  • Page 434 434
  • Page 435 435
  • Page 436 436
  • Page 437 437
  • Page 438 438
  • Page 439 439
  • Page 440 440
  • Page 441 441
  • Page 442 442
  • Page 443 443
  • Page 444 444
  • Page 445 445
  • Page 446 446
  • Page 447 447
  • Page 448 448
  • Page 449 449
  • Page 450 450
  • Page 451 451
  • Page 452 452
  • Page 453 453
  • Page 454 454
  • Page 455 455
  • Page 456 456
  • Page 457 457
  • Page 458 458
  • Page 459 459
  • Page 460 460
  • Page 461 461
  • Page 462 462
  • Page 463 463
  • Page 464 464
  • Page 465 465
  • Page 466 466
  • Page 467 467
  • Page 468 468
  • Page 469 469
  • Page 470 470
  • Page 471 471
  • Page 472 472
  • Page 473 473
  • Page 474 474
  • Page 475 475
  • Page 476 476
  • Page 477 477
  • Page 478 478
  • Page 479 479
  • Page 480 480
  • Page 481 481
  • Page 482 482
  • Page 483 483
  • Page 484 484
  • Page 485 485
  • Page 486 486
  • Page 487 487
  • Page 488 488
  • Page 489 489
  • Page 490 490
  • Page 491 491
  • Page 492 492
  • Page 493 493
  • Page 494 494
  • Page 495 495
  • Page 496 496
  • Page 497 497
  • Page 498 498
  • Page 499 499
  • Page 500 500
  • Page 501 501
  • Page 502 502
  • Page 503 503
  • Page 504 504
  • Page 505 505
  • Page 506 506
  • Page 507 507
  • Page 508 508
  • Page 509 509
  • Page 510 510
  • Page 511 511
  • Page 512 512
  • Page 513 513
  • Page 514 514
  • Page 515 515
  • Page 516 516
  • Page 517 517
  • Page 518 518
  • Page 519 519
  • Page 520 520
  • Page 521 521
  • Page 522 522
  • Page 523 523
  • Page 524 524
  • Page 525 525
  • Page 526 526
  • Page 527 527
  • Page 528 528
  • Page 529 529
  • Page 530 530
  • Page 531 531
  • Page 532 532
  • Page 533 533
  • Page 534 534
  • Page 535 535
  • Page 536 536
  • Page 537 537
  • Page 538 538
  • Page 539 539
  • Page 540 540
  • Page 541 541
  • Page 542 542
  • Page 543 543
  • Page 544 544
  • Page 545 545
  • Page 546 546
  • Page 547 547
  • Page 548 548
  • Page 549 549
  • Page 550 550
  • Page 551 551
  • Page 552 552
  • Page 553 553
  • Page 554 554
  • Page 555 555
  • Page 556 556
  • Page 557 557
  • Page 558 558
  • Page 559 559
  • Page 560 560
  • Page 561 561
  • Page 562 562
  • Page 563 563
  • Page 564 564
  • Page 565 565
  • Page 566 566
  • Page 567 567
  • Page 568 568
  • Page 569 569
  • Page 570 570
  • Page 571 571
  • Page 572 572