HDL HDL-MPS04-RF.18 User manual

Type
User manual
Wireless 4 channels Dry Contact
HDL-MPS04-RF.18
www.hdlautomation.com
User Manual
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual
Version
Date
Description
V1.0
2015.09.06
Create new document
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual
INDEX
1. Overview........................................................................................................................................1
1.1 General Information...........................................................................................................1
1.2 Functionalities Description............................................................................................... 1
1.3 Device Description.............................................................................................................1
2. Safety Instructions....................................................................................................................... 2
3. Technical Data.............................................................................................................................. 2
4. Installation..................................................................................................................................... 3
5. Software Configuration................................................................................................................4
5.1 Wireless Setting via Mesh Gateway...............................................................................4
5.2 Basic Information............................................................................................................... 5
5.2.1 Change the ID of the device.................................................................................6
5.2.2 Remark.....................................................................................................................6
5.3 Configuration...................................................................................................................... 6
5.3.1 Remark.....................................................................................................................6
5.3.2 Switch type.............................................................................................................. 6
5.3.3 Unqualifiedde.......................................................................................................... 9
5.3.4 Delay time................................................................................................................9
5.3.5 Dimming................................................................................................................. 10
5.3.6 Target......................................................................................................................10
5.3.7 Low Limit................................................................................................................11
5.3.8 Setting For Keys................................................................................................... 11
5.4 Security Setting................................................................................................................ 12
6. Online Upgrade.......................................................................................................................... 13
6.1 Automatic Upgrade.......................................................................................................... 13
6.2 Manual Upgrade.............................................................................................................. 14
7 FAQ................................................................................................................................................15
8. Note.............................................................................................................................................. 16
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 1
1. Overview
1.1 General Information
HDL-MPS04-RF.18 wireless dry contact module, it has 4 channels dry contact, can
control target by switch. The module should work in conjunction with wireless gateway.
1.2 Functionalities Description
4 channels dry contact inputs, 4 channels LED outputs
Support electronic switch and mechanical switch, can control the target, has dimming
function
The dry contact supports: mechanical switch, single on, single off, single on/off,
combination on/off, multi-function, parallel switch type.
Each switch type can set switch mode, dimmable two-way, dimmable increase,
dimmable reduce
Control type: scene, sequence, universal switch, single channel lighting control,
broadcast scene, broadcast channel, curtain switch, GPRS control switch, panel
control, security module, z-audio control
Support security function
Support IEEE.802.15.4
Support online upgrading
Support easy programming
1.3 Device Description
36mm
44mm
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 2
2. Safety Instructions
The screw down strength should not exceed 0.1Nm
Mounting position: Indoor.
Never let liquids get into the module, it will damage this device.
3. Technical Data
Electric Parameters
Input voltage
AC85~265V, 50/60Hz
Power consumption
0.44w max.
Wireless transmit power
+10dbm
Wireless receive sensitivity
-90dbm
Indoor communication distance
<=30m(barrier free)
RSSI receive signal intensity
>-80dbm
Wireless central frequency
WPAN (China)
780 to 786 MHz
SRD (Europe)
864 to 870 MHz
ISM (North America)
904 to 928 MHz
Default band
780 MHz
Default PSK
HDL-SecurityKey0
Environmental Conditions
Working temperature
-5~45
Working relative humidity
< 90%
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 3
Storage temperature
-20~+60
Storage relative humidity
< 93%
Approved
CE
RoHS
Production Information
Dimensions
44×36×17 (mm)
Weight
25.5(g)
Housing material
PC
Installation
Wall box
Protection degree
IP20
Fire and null wire
1.5 mm²(the module provides 15cm wire)
Stripping length
5~7 mm
4. Installation
Antenna
Programming button
4 channels Dry contact
LED indicators for 4
channels
L
N
Programming button: if it is
working properly, the green light
will flicker, press the button three
times continuously, the green
light will flicker quickly, enter the
setup mode (the gateway should
enter the setup mode at the same
time, so that can set the wireless
parameters for it)
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 4
5. Software Configuration
5.1 Wireless Setting via Mesh Gateway
Before user can configure the wireless dimmer normally, need to set the wireless
parameters for it via mesh gateway, and the mesh gateway needs to work in mesh mode.
1- Set the free frequency and unique PSK PWD for the gateway
2- For mesh gateway: press the ‘PROG’ button 3 times continuously, the red LED will flash
quickly that means the gateway enters the wireless setup mode.
3- For wireless dry contact: press the ‘PROG’ button 3 times continuously, the LED will
flicker quickly. It means the wireless dry contact enters the wireless setup mode.
4- Click the ‘Search’ button, the wireless device will be shown.
5- Select the node, you will be able to change its ID and remark it. (the Subnet ID must be
same as the gateway’s).
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 5
6- Click ‘Modify Settings of Selection’, and it will show ‘configurate successful’, then all its
wireless parameters will follow the gateway’s (Band, Frequency and PSK).
7- Click ‘all Node Exit Setup’, then the gateway and the panel will exit the wireless setup
mode.
8- Go to the HDL BUS setup tool’s main interface to search and add the wireless dry
contact, then can start to configure it via the gateway.
5.2 Basic Information
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 6
5.2.1 Change the ID of the device
Every wireless device has one Subnet ID and one Device ID, the Device ID should be
unique in its Subnet and the Subnet ID should be kept consistent with the Mesh Gateway
(HDL-MCIP-RF.10).
5.2.2 Remark
Generally set it like “for living room” to indicate some info.
5.3 Configuration
The setting interface is shown above, setting it is same as setting a panel - select mode
for each key, and set targets/objects to each key. Some modes are unique and you cannot
find them in panels.
5.3.1 Remark
Remarks of dry contacts’ switch, you may make remarks according to the installation
places.
5.3.2 Switch type
Two different Switch types - Momentary and Toggle
You can find two different types of switch from the market.
Momentary Switch - When pressed, it is on, when released, it is off.
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 7
If Electrical switch is selected for this kind of switch, a momentary effect can be
produced.
Toggle Switch It is bi-stable switch, you can set it on or off.
Generally select “Mechanic switch” mode for this kind of switch.
Available modes
Mechanic Switch
Send out a command (generally the on command, e.g., light on.) when Switch is
connected, send out another (generally the off command) when the Switch is
disconnected.
Single on
Assign the Switch can turn on one object only (one channel, or one scene, or one
sequence, etc.)
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 8
Single off
Assign the Switch can turn off one object only (one channel, or one scene, or one
sequence, etc.)
Single on/off
Assign the Switch can turn on/off one object only (one channel, or one scene, or one
sequence, etc.)
Combination on
Assign the Switch can turn on multiple objects (channels, scenes, sequence, etc.)
Combination off
Assign the Switch can turn off multiple objects (channels, scenes, sequence, etc.)
Combination on/off
Assign the Switch can turn on/off multiple objects (channels, scenes, sequence, etc.)
Multi-function
Long press – combination off (or dim, if dimming is enabled in the Wireless Dry Contact
module. Dim the first object only, though.)
Short press – single on/off
Double click – Combination on
This mode can be used in, maybe, meeting, by double-click all the lighting can be on, by
long-press, all lighting can be off, this can avoid mishandling and so it is more secure.
Parallel Switch
This key mode is originally designed for retrofit project where the end-users want to
implement HDL wireless system but they want to reserve the existing toggle buttons, the
toggle buttons are to control one public area lighting (e.g., stair lighting) from multiple
places
Wiring
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 9
Connect the two toggle buttons to two different wireless dry contact channels
Setting
Select “Parallel switch” for both wireless dry contact channels.
5.3.3 Unqualifiedde
Each channel can set the mode
Switch mode: on/off control
Dimmable increase: long press to dim up
Dimmable reduced: long press to dim down
Dimmable two-way: long press to dim up, long press again can dim down
5.3.4 Delay time
Only the “Mechanic switch” switch type has the delay time.
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 10
5.3.5 Dimming
Key no. : channel no./ switch no.
Dimming value:
Toggle- when turn on light, the brightness will go to 100%
Memory- save the brightness, when turn on light, the brightness will go to last brightness
before turn off
5.3.6 Target
Can set each channel’s targets.
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 11
5.3.7 Low Limit
Set the dimming lower limit.
The Lower limit is useful if you would like to skip the low level segment and dim from a
certain level, say 50%. You want to skip it because maybe lower than 50% is impractical
for you or maybe the load quality is not so good and trembles when at low level segment.
5.3.8 Setting For Keys
Key Enable: enable/disable the channels.
Panel Lock Key Enable: If be selected, can use panel to lock/unlock this channel.
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 12
5.4 Security Setting
We can use channels of wireless dry contact to trigger security, like the window state, door
state.
If use wireless dry contact 1 to detect the door state for security, the setting steps as
follow:
a) Select ‘key 1’ here and type in the remark.
b) Enable security function.
c) Input the security module’s Subnet/Device ID, totally 8 areas can be selected, here is
area 1.
For further configuration, please turn to security module’s user manual.
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 13
6. Online Upgrade
For the online upgrade, there are two ways, automatic upgrade and manual upgrade.
6.1 Automatic Upgrade
Upgrade steps:
1- Select the online wireless panel that you want to upgrade, click “Read Device Type” to
check its chip type.
2- Select .bin firmware, click “Add Device”, then it will be shown in the upgrade list.
3- Click “Upgrade Selected Device” to start the upgrade.
4- Upgrade finished.
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 14
6.2 Manual Upgrade
For manual upgrade, the panel will enter the wireless setup mode, then the mesh gateway
needs to enter the wireless setup mode also.
Upgrade steps:
1- Press the ‘PROG’ button of wireless gateway 3 times continuously to enter the
wireless setup mode.
2- Power off the wireless dry contact, then keep pressing the programming button when
power on it, it will enter the wireless setup mode, and you will be able to read its ID in
the “Device” line.
3- Select .bin firmware , click “Upgrade”.
4- Upgrade finished.
5- Press the ‘PROG’ button of wireless gateway 1 time to exit the wireless setup mode.
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 15
7 FAQ
7.1 FAQ001
Q:
HDL-MPS04-RF.18 has indicators for four channels output, but where is the appropriate
place to put those indicators?
A:
Some 3rd party panel has a hold, can put the indicator of MPS04-FR.18 in the hold.
7.2 FAQ002
Q:
MPS04-FR.18 has four led output, what’s the type of led can I connect?
A:
Each led channel is 3.3V 10mA, so you can connect the appropriate led.
User Manual
HDL-MPS04-RF.18
Wireless 4 channels Dry Contact – User Manual 16
8. Note
……………………………………………………………………………………………………….
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19

HDL HDL-MPS04-RF.18 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI