Magnescale LH72 Owner's manual

Type
Owner's manual

Magnescale LH72 is a versatile and accurate length and angle measurement device. With its high resolution and durability, it is designed to meet the demands of various industrial applications. Here are some key capabilities of the LH72:

  • Multi-axis measurement: The LH72 can simultaneously measure the length and angle of up to three axes, making it ideal for complex measurement tasks.

  • High resolution: The LH72 offers high resolution measurement, enabling precise and detailed data capture.

  • Polarity change: The display polarity can be reversed, allowing for easy adaptation to different measurement configurations and applications.

Magnescale LH72 is a versatile and accurate length and angle measurement device. With its high resolution and durability, it is designed to meet the demands of various industrial applications. Here are some key capabilities of the LH72:

  • Multi-axis measurement: The LH72 can simultaneously measure the length and angle of up to three axes, making it ideal for complex measurement tasks.

  • High resolution: The LH72 offers high resolution measurement, enabling precise and detailed data capture.

  • Polarity change: The display polarity can be reversed, allowing for easy adaptation to different measurement configurations and applications.

1/3
LH72 Change of display resolution (polarity)
When the display is , press key to select the addition display.
Press key to select a condition.
When you have made your selection, press key to save your settings.
To finish the basic settings, follow steps and below.
Set to basic setting mode.
Turn key "ON" while the AC adapter is energized.
Press and hold key for 3 seconds after the lamp changes from blinking to off.
The display will be . (additional display).
LH72 Change of display resolution (polarity)
Ver.3 (2021.1) CS&S
LH72-3
* If you do not know the output resolution of the measurement unit, refer to the separate "Initial setup manual".
Purpose of change Operation Explanation
Change the polarity for each input axis
while using the addition function
Change the selection of addition display in the basic
settings
Change the measurement unit resolution Change the length measurement unit resolution in
the basic settings. And check the display resolution
in the detailed settings.
Change the display resolution Change the display resolution in the detailed
settings
Change the display polarity
(Counting direction is reversed)
Change the display resolution in the detailed
settings
Diameter display (double count value) Change to diameter display with display resolution
in the detailed settings
Detailed settings Display resolution Change
Detailed settings Display resolution Diameter display
The operation method for changing the display resolution differs depending on the purpose and conditions of the change.
Select the purpose and conditions to be changed from the table below and perform the operation.
Basic setting Measurement unit resolution Change
Basic settings Addition display Change
Detailed settings Display resolution Change polarity
Basic settings Addition display Change
Input 3 - Input 2
Input 2
Input 3
Input 2 + Input 3
Input 2 - Input 3
- (input 2 + Input 3)
Addition display (input conditions to
be displayed on the Z axis)
If you press key once, it will automatically enter the advanced setting mode and display.
Press key to enter normal count mode.
Switch from basic settings to normal count mode.
Press key once and the display will change to .
Press key once and the display will change to .
About 2 sec
Power ON
2/3
LH72 Change of display resolution (polarity)
Press key twice.
The display will be (measurement unit resolution).
Press key to check the current measurement unit resolution.
Set to basic setting mode.
Turn key “ON” while the AC adapter is energized.
Press and hold key for 3 seconds after the lamp changes from blinking to off.
The display will be . (additional display).
LH72-3
Basic setting Measurement unit resolution Change
About 2 sec
Press key of the axis you want to change and select
the measurement unit resolution.
When you have made your selection, press key to save your settings.
Display of measurement unit resolution
(LH72-3)
Input 1
Input 2
Input 3
Standard Expansion
Extended key
Selection of measurement
unit resolution
Press key once to automatically switch to advanced settings mode. The display will be .
Press key, the display becomes the normal display.
Switch from basic settings to normal count mode.
Press key once and the display will change to .
Press key once and the display will change to .
Diameter display
Angle display
Length display
NOTE 1: Selection of a value smaller than the basic setting measurement unit
resolution is not displayed.
NOTE 2: The angle display can be set when the angle resolution is selected in
the basic settings.
NOTE 1 NOTE 2
Selection of display resolution
Expansion
Extended key
Detailed settings Display resolution Change
Press key once to display the display resolution of each axis.
Press key of the axis you want to change and select the resolution.
Please note that the lamp lights up once every two times and the diameter display is set.
When you have made your selection, press key to save your settings.
Press key to return to the normal counting state.
Set to the detailed settings mode.
Press key while the normal count mode is energized.
The display will be . (Detailed setting mode)
3/3
LH72 Change of display resolution (polarity)
Set to advanced mode.
Press key in normal count mode
The display will be .
Press key once to get the display resolution of each axis.
Press key of the axis you want to change to the diameter display and turn on the lamp.
If the resolution changes, press key again.
When you have made your selection, press key to save your settings.
Press key to return to the normal counting state.
Detailed settings Display resolution Diameter display
Press key once to get the display resolution of each axis.
Press key for the axis for which you want to change the polarity,
and then press key.
When you have made your selection, press key to save your settings.
Press key to return to the normal counting state.
Detailed settings Display resolution Change polarity
Set to advanced mode.
Press key in normal count mode
The display will be .
Diameter display
Before After
Change polarity
Example of changing the polarity of the display in the middle row
  • Page 1 1
  • Page 2 2
  • Page 3 3

Magnescale LH72 Owner's manual

Type
Owner's manual

Magnescale LH72 is a versatile and accurate length and angle measurement device. With its high resolution and durability, it is designed to meet the demands of various industrial applications. Here are some key capabilities of the LH72:

  • Multi-axis measurement: The LH72 can simultaneously measure the length and angle of up to three axes, making it ideal for complex measurement tasks.

  • High resolution: The LH72 offers high resolution measurement, enabling precise and detailed data capture.

  • Polarity change: The display polarity can be reversed, allowing for easy adaptation to different measurement configurations and applications.

Ask a question and I''ll find the answer in the document