MyWeigh HD-150 Owner's manual

Type
Owner's manual

This manual is also suitable for

HD-SERIES
ENGLISH
Thank you for purchasing the My Weigh HD Series heavy duty shipping scale. This scale is designed to provide years of accurate
weighing. Please read this entire manual before use. If you have any questions about your scale or have troubleshooting con-
cerns, please visit our website at www.MyWeigh.com.
SPECIFICATIONS
Model HD150 HD300
Capacity 68kg/150lb 136kg/300lb
Accuracy 0.02kg/0.05lb 0.05kg/0.1lb
POWER SUPPLY
The HD Series scale is designed to run with 6.0V / 100 mA AC power (ac adapter included) or optional 4x AA batteries. The AC
adapter plugs into the socket on the rear of the scales weighing indicator. If you want to use batteries, please install them in the
battery compartment on the underside of the base of the scale.
Battery Installation
For battery installation, turn over the scale, you’ll see the battery compartment on the underside of the base of the scale , lift
and open (see the enclosed drawing Fig1) the battery cover, remove and/or install the batteries. Be sure that the batteries are
installed correctly following the polarity indicators in the battery compartment. Reinstall the battery cover.
OPERATION INSTRUCTIONS
on the scale. Either place the remote display box together with the scale on its surface or mount the display box on a wall at a
suitable height with the included wall mounting kit.
Weighing Procedures
Press the key to turn on the scale, the display will show “150.00lb for the HD150 shipping scale or“300.0lb” for the HD300
shipping scale. When the display will shows ”0.00” thhe scale is now ready for use. To begin weighing, follow these steps:
1. Press and release the
2. Press the [M] key to change the weighing unit between “lb” and “kg.
3. Press the [T] key to TARE or Zero the scale.
4. Press the [D] key to transmit the data through the USB port.
Display Messages
150.00: the scales maximum capacity is 150.00lbs, the scale is attempting to locate the proper zero position for accurate
weighing.
300.00: the scales maximum capacity is 300.00lbs, the scale is attempting to locate the proper zero position for accurate
weighing.
Err-Z: zero track range has exceeded
A.0FF.x
CAL-Er: calibration error
CAL-0: the indicator mark of calibration zero
CAL-F: the indicator mark of calibration full capacity
Err-0: overload
Err-S: unstable
1. Press down the [D] key until the indicator displaysA.OFF.X” (X=0.1.2.3.4.5.6.7.8.9 minutes), the display value “X” is the
[M] or [D] key; the X value will increase or decrease by 1, press the [T] key to
key, the display will then reset.
CALIBRATION
Calibration is only for ADVANCED USERS or scale technicians and should only be performed if absolutely necessary.
There are two calibration methods available: one is using standard professional calibration weights, the other is the selection of
1. Press down the [T] key until the indicator displays GE.Uxx”, “GE.oxx” orGE. FAC”; a. GE.Uxx” means: USA geographic
location code “xx” is selected; b. GE. FAC means: Factory geographic location code is selected; c. GE.oxx means:
Other(except for USA and Factory) geographic location code “xx” is selected.
2. Press the [M] or [D] key to change the geographic location code; please refer the geographic location code table and maps at
the end of the manual.
3. After selecting the appropriate geographic location code, press the [T] key, the scale will store your selection and display
“CAL-0” or “Go.on?”
If “CAL-0” is displayed, that means the scale must be calibrated once more by using standard weights and you should proceed
to the next step;
If “Go.on?” is displayed and the key is pressed, the scale will use the selected geographic location code and reset automati-
cally to resume normal weighing mode;
If “Go.on?” is displayed and the [T] key is pressed, the scale will display CAL-0” and you should proceed to the next calibration
step.
4. Remove all weights from the scale platform, press the [T] key , the “0” in “CAL-0”
5. After the reading (0.00) becomes stable, the scale will display “CAL-F”; place the correct standard weight(s) on the platform
(60kg standard weight for HD150, 120kg standard weight for HD300), press the [T] key, the “F” in “CAL-F”
6. After the readings (60.00 for HD150 or 120.00 for HD300) are stable, the indicator will display CAL-0”; remove the weight(s)
from the platform, press the [T] key; the “0” in “CAL-0”
Calibration is now complete.
GRAVITY MODE
The Gravity Mode feature provides a means of adjusting the scales internal calibration factors to compensate for variations in
-
ferent weight at an end-users (local) site than it did at the Calibration (CAL) site.
The scale maintains two gravity setting values: one is local site gravity value; the other is calibration site gravity value. The
scale will use the relationship between calibration and local gravity for its weight calculations.
We have compiled a list of local gravity values for some areas of the world. You only need select the index number of them
scale. It is important to select the proper code. If your location is not listed, select closest one. This kind of adjustment needs no
calibration weights.
However, whenever possible, we strongly recommend that you calibrate the scale by using standard professional calibration
weights.
Europe Geographic Location Codes
Portugal
Morocco
Iceland
Ireland
Spain
Albania
Andorra
Austria
Belarous
Belgium
Bosnia and Herzegovina
Bulgaria
Croatia
Czech Republic
Denmark
Estonia
Faroe Islands
Finland
France
Lyon & North
South of Lyon
Germany
Frankfort & North
South of Frankfort
Gibraltar
Algeria
UK
8
8
9
10
10
8
8
9
9
11
11
12
12
9
8
10
9
7
7
8
9
12
10
8
11
9
11
9
8
7
9
8
10
12
10
7
7
12
10
8
7
8
9
9
8
12
11
9
9
11
10
Netherlands
Belgium
France
Norway
Sweden
Denmark
Germany
Switzerland
Czech Rep.
Slovenia
Italy
13
12
Finland
11 Estonia
Latvia
10
Poland
Slovakia
Hungary
Lithuania
Serbia &
8
9
Bosnia &
Herezgovinia
Belarus
Romania
Montenegro
Albania
Greece
Holy See (Vatican City)
Hungary
Iceland
Ireland
Italy
Latvia
Liechtenstein
Lithuania
Luxembourg
Macedonia
Malta
Moldova
Monaco
Netherlands
Norway
Poland
Portugal
Romania
7
Bulgaria
Macedonia
Greece
6
Ukraine
Moldova
Turkey
Russia
Russia
Moscow & North
South of Moscow
Spain
Madrid & North
South of Madrid
Serbia and Montenegro
Slovakia
Slovenia
San Marino
Sweden
North of Stockholm
Stockholm & South
Switzerland
Ukraine
United Kingdom
North of Newcastle
Newcastle & South
Croatia
Austria
Code Code Code
Country Country Country
Canada Geographic Location Codes
Yukon
Territory
British
Columbia
Northwest
Territories
Alberta
State
Alberta
North of Edmonton
Edmonton & South
British Columbia
North of Prince George
Prince George & South
Manitoba
North of Norway House
Norway House & South
New Brunswick
Newfoundland
North of Hopedail
Between Hopedail & Fleur de lys
Fleur de lys & South
Nova Scotia
Ontario
North of Nakina
Nakina & South
Saskatchewan
11
10
11
10
11
10
9
11
10
9
8
10
9
Nunavut Territory
Manitoba
Ontario
14
13
12
11
10
9
8
Quebec
Ottawa
Newfoundland
Prince
Edward Island
New Brunswick
Prince Edward Island
Quebec
Sept-Iles & South
Saskatchewan
North of Prince Albert
Prince Albert & South
Northwest Territories
Echo bay & North
South of Echo bay
Nunavut Territory
Victoria Island & North
Between Victoria Island &
Baker Lake
South of Baker Lake
Yukon Territory
North of Dawson
Dawson & South
Nova Scotia
9
11
10
9
11
10
13
12
14
13
12
13
21
Code Code
State State
Europe Geographic Location Codes
Europe Geographic Location Codes
Illinois
Bloomington & North
South of Bloomington
Indiana
North of Indianapolis
Indianapolis & South
Iowa
North of Des Moines
Des Moines &South
Kansas
Kentucky
Louisiana
Maine
Maryland
Massachusetts
Michigan
Northwest of Lake Michigan
Southeast of Lake Michigan
Minnesota
16
15
16
15
16
15
15
14
12
18
15
17
17
16
18
Pennsylvania
Rhode Island
South Carolina
South Dakota
Tennessee
Texas
Northeast of Colorado River
Southwest of Colorado River
Utah
Vermont
Virginia
Washington. DC
Washington State
West Virginia
Wisconsin
Green Bay & North
South of Green Bay
Wyoming
North of Casper
Casper & South
16
16
13
17
13
12
11
13
17
14
15
18
15
18
17
15
14
USA Geographic Location Codes
HI
AK
27
26
23
9
State
Alabama
Birmingham & North
South of Birmingham
Alaska
North of Fairbanks
Between Anchorage & Fair-
banks
South of Anchorage
Arizona
Phoenix & North
South of Phoenix
Arkansas
California
Redding & North
Between Redding & Fresno
Fresno & Los Angeles
Los Angeles & South
Colorado
Denver & North
South of Denver
Connecticut
Delaware
Florida
West Palm Beach & North
South of West Palm Beach
Georgia
Hawaii
Idaho
North of Salmon River Mtns
South of Salmon River Mtns
MT ND
WY
WA
OR
CA
NV
AZ
UT CO
NM
TX
SD
NE
19
18
17 MN
16
15
14
IA
OK
KS
WI
MO
AR
13
12
27
26
23
12
11
13
16
15
14
13
13
12
16
15
11
10
12
9
17
61
13
12
11
10
IL
LA
MS
State
Mississippi
Kosciusko & North
South of Kosciusko
Missouri
Montana
Helena & North
South of Helena
Nebraska
Nevada
New Hampshire
New Jersey
New Mexico
New York
Albany & North
South of Albany
North Carolina
Raliegh & North
South of Raliegh
North Dakota
Ohio
Akron & North
South of Akron
Oklahoma
Oregon
Salem & North
Between Oakridge & Salem
South of Oakridge
MI
IN
TN
AL
OH
VT
NY
PA
WV
GA
NC
VA
KY
SC
FL
13
12
15
14
18
17
15
13
17
16
11
17
16
14
13
18
16
15
13
18
17
61
ME
NH
MA
RI
CT
NJ
DE
MD
Code Code
CONNECTING THE HD-300 SCALE VIA USB
1. Connect the HD-300 scale to an available USB port on your computer.
2. Power on the scale.
SETTING UP THE HD-300 FOR USE WITH THE UPS WORLDSHIP SOFTWARE
- USA/CANADA ONLY
** Please note this function will not work in Europe**
1. Open the UPS Worldship software and click on “tools”.
2. Click on “System Preferences”.
3. Click on “Hardware” in the drop-down menu.
4. Click on “Scale Port drop-down menu and choose “USB”.
5. Click on “Scale Type” drop-down menu and choose Toledo PS60-5155 150lb Flat Top”.
6. Click the “Test Scale” button.
7. As you place an item on the scale, you will see the weight displayed in the “weight” -
“OK” to exit this screen. On the next screen, click “OK” again to exit to
the main screen.
8. Finally, ensure that the box next to “Electronic Scale Activated” is checked. Your scale is now set up and ready to use.
USB PORT
AC ADAPTER SOCKET
Fig1: Bottom view of the scale
4 adjust-
able feet
4 over load
protection
screws
Fig 2: Indicators outline and placement positioning
batteries
4 x AA size
Hanging on wall Placed on a table
SPECIFICATIONS
Model HD150 HD300
Capacity 68kg/150lb 136kg/300lb
Accuracy 0.02kg/0.05lb
Units
Platform dimension
Display dimension
Scale Weight
lb, kg
0.05kg/0.1lb
355.5 x 355.5 x 63.5mm (14” x 14” x 2.5”)
165 x 82.5mm (6.5” x 3.25”)
3.4kg
Operating temperature
Power Source
Optimum 10-40°C (50-104°f)
6.0V / 100 mA AC Power adaptor / 4 x AA Batteries
Load
cell
Battery
compartment
and cover
www.myweigh.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

MyWeigh HD-150 Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI