Rohde&Schwarz VSE User manual

Type
User manual
R&S®VSE-K7
AM/FM/PM Modulation Analysis
Application
User Manual
1176893902
Version 13
(;ÚçW2)
This manual applies to the following software, version 2.30 and later:
R&S®VSE Enterprise Edition base software (1345.1105.06)
R&S®VSE Basic Edition base software (1345.1011.06)
The following software options are described:
R&S VSE-K7 (1320.7539.xx)
R&S®CMA-K310 (1320.7945.xx)
R&S VSE-KT7 (1345.1928.02)
© 2023 Rohde & Schwarz GmbH & Co. KG
Muehldorfstr. 15, 81671 Muenchen, Germany
Phone: +49 89 41 29 - 0
Internet: www.rohde-schwarz.com
Subject to change – data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
All other trademarks are the properties of their respective owners.
1176.8939.02 | Version 13 | R&S®VSE-K7
Throughout this manual, products from Rohde & Schwarz are indicated without the ® symbol, e.g. R&S®VSE is indicated as
R&S VSE.
Contents
R&S®VSE-K7
3User Manual 1176.8939.02 ─ 13
Contents
1 Preface.................................................................................................... 9
1.1 About this manual.........................................................................................................9
1.2 Typographical conventions........................................................................................10
2 Welcome to the R&S VSE AM/FM/PM Modulation Analysis applica-
tion.........................................................................................................11
2.1 Starting the R&S VSE AM/FM/PM Modulation Analysis application.......................11
2.2 Understanding the display information.................................................................... 12
3 Measurements and result displays.................................................... 15
4 Measurement basics............................................................................25
4.1 Demodulation process............................................................................................... 25
4.2 Demodulation bandwidth........................................................................................... 27
4.3 Sample rate and demodulation bandwidth...............................................................27
4.4 AF filters.......................................................................................................................28
4.5 Time domain zoom......................................................................................................28
4.6 Working with spectrograms.......................................................................................30
4.6.1 Time frames.................................................................................................................. 32
4.6.2 Color maps....................................................................................................................33
5 Configuration........................................................................................36
5.1 Configuration according to digital standards.......................................................... 36
5.2 Configuration overview.............................................................................................. 38
5.3 Input and frontend settings........................................................................................40
5.3.1 Input source settings..................................................................................................... 40
5.3.1.1 Radio frequency input................................................................................................... 40
5.3.1.2 I/Q file input................................................................................................................... 47
5.3.2 Amplitude...................................................................................................................... 48
5.3.3 Frequency..................................................................................................................... 52
5.4 Trigger source settings.............................................................................................. 54
5.5 Data acquisition.......................................................................................................... 58
5.5.1 Bandwidth settings........................................................................................................ 58
5.5.2 Capture settings............................................................................................................ 59
Contents
R&S®VSE-K7
4User Manual 1176.8939.02 ─ 13
5.6 Demodulation.............................................................................................................. 62
5.6.1 Basic demodulation measurement parameters (Demod)..............................................62
5.6.2 Demodulation spectrum................................................................................................ 65
5.6.2.1 AF evaluation................................................................................................................ 66
5.6.2.2 RF evaluation................................................................................................................ 67
5.6.3 AF filter..........................................................................................................................69
5.6.4 Scaling.......................................................................................................................... 71
5.6.4.1 AF evaluation................................................................................................................ 72
5.6.4.2 RF evaluation................................................................................................................ 74
5.6.5 Units.............................................................................................................................. 76
5.6.6 Result table settings......................................................................................................77
5.6.7 Settling time.................................................................................................................. 79
5.7 Adjusting settings automatically...............................................................................80
6 Analysis................................................................................................ 84
6.1 Trace settings.............................................................................................................. 84
6.2 Trace / data export configuration.............................................................................. 88
6.3 Spectrogram settings................................................................................................. 90
6.3.1 General spectrogram settings....................................................................................... 90
6.3.2 Color map settings........................................................................................................ 92
6.4 Working with markers in the R&S VSE AM/FM/PM Modulation Analysis applica-
tion................................................................................................................................94
6.4.1 Marker settings..............................................................................................................95
6.4.1.1 Individual marker setup................................................................................................. 95
6.4.1.2 General marker settings................................................................................................98
6.4.2 Marker search settings and positioning functions....................................................... 100
6.4.2.1 Marker search settings................................................................................................101
6.4.2.2 Positioning functions................................................................................................... 102
6.4.3 Marker function configuration......................................................................................103
6.4.3.1 Measuring characteristic bandwidths (n db down marker)..........................................104
6.4.3.2 Phase noise measurement marker............................................................................. 106
6.4.3.3 Marker peak list...........................................................................................................109
6.4.3.4 Deactivating all marker functions.................................................................................111
6.5 Working with limit lines in the R&S VSE AM/FM/PM Modulation Analysis applica-
tion..............................................................................................................................112
Contents
R&S®VSE-K7
5User Manual 1176.8939.02 ─ 13
6.5.1 Basics on limit lines..................................................................................................... 112
6.5.2 Limit line settings and functions...................................................................................115
6.5.2.1 Limit line management................................................................................................ 116
6.5.2.2 Limit line details...........................................................................................................119
6.5.3 How to define limit lines.............................................................................................. 121
6.6 Zoom functions......................................................................................................... 124
7 How to perform measurements in the R&S VSE AM/FM/PM Modula-
tion Analysis application...................................................................126
8 Optimizing and troubleshooting the measurement........................ 128
9 Remote commands for analog modulation analysis...................... 129
9.1 Introduction............................................................................................................... 130
9.1.1 Conventions used in descriptions............................................................................... 130
9.1.2 Long and short form.................................................................................................... 131
9.1.3 Numeric suffixes..........................................................................................................131
9.1.4 Optional keywords.......................................................................................................131
9.1.5 Alternative keywords................................................................................................... 132
9.1.6 SCPI parameters.........................................................................................................132
9.1.6.1 Numeric values........................................................................................................... 132
9.1.6.2 Boolean....................................................................................................................... 133
9.1.6.3 Character data............................................................................................................ 134
9.1.6.4 Character strings.........................................................................................................134
9.1.6.5 Block data................................................................................................................... 134
9.2 Common suffixes...................................................................................................... 134
9.3 Activating AM/FM/PM Modulation Analysis measurements................................. 135
9.4 Configuring the measurement................................................................................. 135
9.4.1 Restoring the default configuration (preset)................................................................ 135
9.4.2 Managing standard settings........................................................................................ 136
9.4.3 Configuring data input................................................................................................. 137
9.4.3.1 RF input.......................................................................................................................137
9.4.3.2 Configuring oscilloscope baseband input....................................................................148
9.4.3.3 Using external mixers..................................................................................................151
Basic settings.............................................................................................................. 151
Mixer settings.............................................................................................................. 153
Contents
R&S®VSE-K7
6User Manual 1176.8939.02 ─ 13
Programming example: working with an external mixer..............................................159
9.4.3.4 Remote commands for external frontend control........................................................ 160
Commands for initial configuration..............................................................................160
9.4.3.5 Working with power sensors....................................................................................... 167
Configuring power sensors......................................................................................... 167
Configuring power sensor measurements.................................................................. 168
9.4.4 Frequency settings......................................................................................................175
9.4.5 Configuring the vertical axis (amplitude, scaling)........................................................176
9.4.5.1 Amplitude settings.......................................................................................................176
9.4.5.2 Configuring the attenuation......................................................................................... 178
9.4.5.3 Configuring a preamplifier........................................................................................... 181
9.4.5.4 Scaling the Y-axis........................................................................................................182
9.4.6 Configuring data acquisition........................................................................................185
9.4.7 Triggering.................................................................................................................... 188
9.4.7.1 Configuring the triggering conditions...........................................................................189
9.4.7.2 Configuring the trigger output......................................................................................197
9.4.8 Configuring demodulation........................................................................................... 198
9.4.8.1 Basic demodulation settings....................................................................................... 199
9.4.8.2 Time domain zoom settings........................................................................................ 201
9.4.8.3 Configuring the demodulation spectrum..................................................................... 203
AF evaluation.............................................................................................................. 203
RF evaluation.............................................................................................................. 205
9.4.8.4 (Post-processing) AF filters.........................................................................................206
9.4.8.5 Defining the scaling and units......................................................................................211
9.4.8.6 Scaling for AF evaluation.............................................................................................211
9.4.8.7 Scaling for RF evaluation............................................................................................ 212
9.4.8.8 Units............................................................................................................................ 212
9.4.8.9 Relative demodulation results..................................................................................... 213
9.4.8.10 Settling time................................................................................................................ 216
9.4.9 Adjusting settings automatically.................................................................................. 217
9.4.10 Configuring standard traces........................................................................................ 221
9.4.11 Configuring spectrograms........................................................................................... 227
9.4.11.1 Configuring a spectrogram measurement...................................................................227
Contents
R&S®VSE-K7
7User Manual 1176.8939.02 ─ 13
9.4.11.2 Configuring the color map........................................................................................... 231
9.5 Configuring the result display................................................................................. 233
9.5.1 Global layout commands.............................................................................................233
9.5.2 Working with windows in the display...........................................................................236
9.5.3 General window commands........................................................................................243
9.6 Retrieving results......................................................................................................243
9.6.1 Retrieving trace results............................................................................................... 244
9.6.2 Exporting trace results................................................................................................ 247
9.6.3 Retrieving result summary values............................................................................... 249
9.7 Analyzing results...................................................................................................... 254
9.7.1 Working with markers remotely...................................................................................254
9.7.1.1 Setting up individual markers...................................................................................... 254
9.7.1.2 General marker settings..............................................................................................261
9.7.1.3 Marker search (spectrograms).................................................................................... 263
Using markers............................................................................................................. 263
Using delta markers.................................................................................................... 267
9.7.1.4 Marker search settings................................................................................................272
9.7.1.5 Positioning the marker................................................................................................ 272
Positioning normal markers.........................................................................................273
Positioning delta markers............................................................................................275
9.7.1.6 Configuring special marker functions.......................................................................... 278
Fixed reference marker settings..................................................................................278
Marker peak lists......................................................................................................... 280
N db down marker.......................................................................................................284
Phase noise measurement marker............................................................................. 287
9.7.2 Defining limit checks................................................................................................... 289
9.7.2.1 Configuring limit lines.................................................................................................. 289
9.7.2.2 Managing limit lines.....................................................................................................298
9.7.2.3 Checking the results of a limit check...........................................................................301
9.7.2.4 Programming example: using limit lines......................................................................302
Example: configuring limit lines...................................................................................302
Example: performing a limit check.............................................................................. 303
9.7.3 Zooming into the display............................................................................................. 304
Contents
R&S®VSE-K7
8User Manual 1176.8939.02 ─ 13
9.7.3.1 Using the single zoom.................................................................................................304
9.7.3.2 Using the multiple zoom..............................................................................................306
9.8 Programming example............................................................................................. 308
Annex.................................................................................................. 311
A Reference............................................................................................311
A.1 Menu reference..........................................................................................................311
A.1.1 Common R&S VSE menus..........................................................................................311
A.1.1.1 File menu.....................................................................................................................311
A.1.1.2 Window menu............................................................................................................. 312
A.1.1.3 Help menu...................................................................................................................313
A.1.2 Analog demodulation menus.......................................................................................313
A.1.2.1 Edit menu.................................................................................................................... 314
A.1.2.2 Input & output menu....................................................................................................314
A.1.2.3 Meas setup menu........................................................................................................314
A.1.2.4 Trace menu................................................................................................................. 315
A.1.2.5 Marker menu............................................................................................................... 315
A.1.2.6 Limits menu.................................................................................................................316
A.2 Reference of toolbar functions................................................................................ 316
A.3 Predefined standards and settings......................................................................... 320
A.4 Formats for returned values: ASCII format and binary format............................. 322
A.5 Reference: ASCII file export format.........................................................................322
List of Remote Commands (Analog Modulation Analysis)............ 325
Index....................................................................................................335
Preface
R&S®VSE-K7
9User Manual 1176.8939.02 ─ 13
1 Preface
1.1 About this manual
This R&S VSE AM/FM/PM Modulation Analysis User Manual provides all the informa-
tion specific to the application. All general software functions and settings common
to all applications and operating modes are described in the R&S VSE Base Software
User Manual.
The main focus in this manual is on the measurement results and the tasks required to
obtain them. The following topics are included:
Welcome to the R&S VSE AM/FM/PM Modulation Analysis application Appli-
cation
Introduction to and getting familiar with the application
Measurements and Result Displays
Details on supported measurements and their result types
Measurement Basics
Background information on basic terms and principles in the context of the mea-
surement
Configuration + Analysis
A concise description of all functions and settings available to configure measure-
ments and analyze results with their corresponding remote control command
How to Perform Measurements in the R&S VSE AM/FM/PM Modulation Analy-
sis application Application
The basic procedure to perform each measurement and step-by-step instructions
for more complex tasks or alternative methods
Measurement Examples
Detailed measurement examples to guide you through typical measurement sce-
narios and allow you to try out the application immediately
Optimizing and Troubleshooting the Measurement
Hints and tips on how to handle errors and optimize the measurement configura-
tion
Remote Commands for R&S VSE AM/FM/PM Modulation Analysis application
Measurements
Remote commands required to configure and perform R&S VSE AM/FM/PM Modu-
lation Analysis application measurements in a remote environment, sorted by tasks
(Commands required to set up the environment or to perform common tasks in the
software are provided in the R&S VSE Base Software User Manual)
Programming examples demonstrate the use of many commands and can usually
be executed directly for test purposes
List of remote commands
Alphabetical list of all remote commands described in the manual
Index
About this manual
Preface
R&S®VSE-K7
10User Manual 1176.8939.02 ─ 13
1.2 Typographical conventions
The following text markers are used throughout this documentation:
Convention Description
"Graphical user interface ele-
ments"
All names of graphical user interface elements on the screen, such as
dialog boxes, menus, options, buttons, and softkeys are enclosed by
quotation marks.
[Keys] Key and knob names are enclosed by square brackets.
Filenames, commands,
program code
Filenames, commands, coding samples and screen output are distin-
guished by their font.
Input Input to be entered by the user is displayed in italics.
Links Links that you can click are displayed in blue font.
"References" References to other parts of the documentation are enclosed by quota-
tion marks.
Typographical conventions
Welcome to the R&S VSE AM/FM/PM Modulation Analysis application
R&S®VSE-K7
11User Manual 1176.8939.02 ─ 13
2 Welcome to the R&S VSE AM/FM/PM Mod-
ulation Analysis application
The (optional) R&S VSE AM/FM/PM Modulation Analysis application converts the
R&S VSE into an analog modulation analyzer for amplitude-, frequency- or phase-
modulated signals. It measures not only characteristics of the useful modulation, but
also factors such as residual FM or synchronous modulation.
The digital signal processing in the R&S VSE is also ideally suited for demodulating
AM, FM, or PM signals. The R&S VSE AM/FM/PM Modulation Analysis application
provides the necessary measurement functions. This application is optional and
requires an additional license.
The R&S VSE AM/FM/PM Modulation Analysis application features:
AM, FM, and PM demodulation, with various result displays:
Modulation signal versus time
Spectrum of the modulation signal (FFT)
RF signal power versus time
Spectrum of the RF signal
Determining maximum, minimum and average or current values in parallel over a
selected number of measurements
Error-free AM to FM conversion and vice versa, without deviation errors, frequency
response or frequency drift at DC coupling
Relative demodulation, in relation to a user-defined or measured reference value
This user manual contains a description of the functionality that the application pro-
vides, including remote control operation.
All functions not discussed in this manual are the same as in the base unit and are
described in the R&S VSE User Manual.
2.1 Starting the R&S VSE AM/FM/PM Modulation Analysis
application
The R&S VSE AM/FM/PM Modulation Analysis application is a separate application on
the R&S VSE. It is activated by creating a new measurement channel in "Analog
Demod" mode.
To activate the R&S VSE AM/FM/PM Modulation Analysis application
1.
Select the "Add Channel" function in the Sequence tool window.
A dialog box opens that contains all operating modes and applications currently
available in your R&S VSE.
Starting the R&S VSE AM/FM/PM Modulation Analysis application
Welcome to the R&S VSE AM/FM/PM Modulation Analysis application
R&S®VSE-K7
12User Manual 1176.8939.02 ─ 13
2. Select the "Analog Demodulation" item.
The R&S VSE opens a new measurement channel for the R&S VSE AM/FM/PM
Modulation Analysis application.
2.2 Understanding the display information
The following figure shows a measurement diagram during Analog Modulation Analy-
sis . All different information areas are labeled. They are explained in more detail in the
following sections.
Understanding the display information
Welcome to the R&S VSE AM/FM/PM Modulation Analysis application
R&S®VSE-K7
13User Manual 1176.8939.02 ─ 13
1 = Color coding for windows of same channel
2 = Channel bar with measurement settings
3 = Window title bar with diagram-specific (trace) information
4 = Diagram area
5 = Diagram footer with diagram-specific information, depending on result display
Channel bar information
In the R&S VSE AM/FM/PM Modulation Analysis application, the R&S VSE shows the
following settings:
Table 2-1: Information displayed in the channel bar in the R&S VSE AM/FM/PM Modulation Analysis
application
Ref Level Reference level
m.+el.Att Mechanical and electronic RF attenuation
Offset Reference level offset
AQT Measurement time for data acquisition.
RBW Resolution bandwidth
DBW Demodulation bandwidth
Freq Center frequency for the RF signal
Window title bar information
For each diagram, the header provides the following information:
Understanding the display information
Welcome to the R&S VSE AM/FM/PM Modulation Analysis application
R&S®VSE-K7
14User Manual 1176.8939.02 ─ 13
Figure 2-1: Window title bar information in the R&S VSE AM/FM/PM Modulation Analysis application
0 = Color coding for windows of same channel
1 = Edit result display function
2 = Channel name
3 = Window number
4 = Window type
5 = Trace color, trace number, detector type, trade mode
6 = AF coupling (AC/DC), only in AF time domains, if applicable
7 = Reference value (at the defined reference position)
8 = Dock/undock window function
9 = Close window function
Diagram footer information
The diagram footer (beneath the diagram) contains the following information, depend-
ing on the evaluation:
RF Spectrum
CF: Center frequency
of input signal
Sweep points Span: measured span
RF Time domain
CF: Center frequency
of input signal
Sweep points Time per division
AF Spectrum
AF CF: center fre-
quency of demodula-
ted signal
Sweep points AF Span: evaluated span
AF Time domain
CF: Center frequency
of input signal
Sweep points Time per division
For most modes, the number of sweep points shown in the display are indicated in the
diagram footer. In zoom mode, the (rounded) number of currently displayed points are
indicated.
Understanding the display information
Measurements and result displays
R&S®VSE-K7
15User Manual 1176.8939.02 ─ 13
3 Measurements and result displays
Access: "Overview" > "Display Config"
Or: [MEAS] > "Display Config"
The data that was measured by the R&S VSE can be evaluated using various different
methods. In the Analog Modulation Analysis application, up to six evaluation methods
can be displayed simultaneously in separate windows. The results can be displayed as
absolute deviations or relative to a reference value or level.
The abbreviation "AF" (for Audio Frequency) refers to the demodulated AM, FM or PM
signal.
Result display windows
For each measurement, a separate channel is activated. Each channel can provide
multiple result displays, which are displayed in individual windows. The measurement
windows can be rearranged and configured in the R&S VSE to meet your require-
ments. All windows that belong to the same measurement (including the channel bar)
are indicated by a colored line at the top of the window title bar.
To add further result displays for the AM/FM/PM Modulation Analysis channel,
select the "Add Window" icon from the toolbar, or select the "Window" > "New
Window" menu item.
For details on working with channels and windows, see the "Operating Basics"
chapter in the R&S VSE Base Software User Manual.
Basis for evaluation
All evaluations are based on the I/Q data set acquired during the measurement. The
spectrum of the modulated signal to be evaluated is determined by the demodulation
bandwidth. However, it can be restricted to a limited span ("AF Span") if only part of the
signal is of interest. Furthermore, the time base for evaluations in the time domain can
be restricted to analyze a smaller extract in more detail, see Chapter 4.5, "Time
domain zoom", on page 28.
Spectrograms
Spectrograms are not configured as separate result displays, but as a subwindow of
any existing graphical result display window. They are activated and deactivated in the
"Spectrogram" tab of the "Traces" settings (see Chapter 6.3, "Spectrogram settings",
on page 90).
AM Time Domain...........................................................................................................16
FM Time Domain...........................................................................................................16
PM Time Domain...........................................................................................................17
AM Spectrum................................................................................................................ 17
FM Spectrum.................................................................................................................18
PM Spectrum................................................................................................................ 19
Measurements and result displays
R&S®VSE-K7
16User Manual 1176.8939.02 ─ 13
RF Time Domain........................................................................................................... 20
RF Spectrum.................................................................................................................21
Result Summary............................................................................................................21
Marker Table................................................................................................................. 23
Marker Peak List........................................................................................................... 23
AM Time Domain
Displays the modulation depth of the demodulated AM signal (in %) versus time.
Optionally, the settling time can be evaluated and displayed, see Chapter 5.6.7, "Set-
tling time", on page 79.
Remote command:
LAY:ADD? '1',RIGH,'XTIM:AM:REL'
(See LAYout:ADD[:WINDow]? on page 237)
FM Time Domain
Displays the frequency spectrum of the demodulated FM signal versus time.
Measurements and result displays
R&S®VSE-K7
17User Manual 1176.8939.02 ─ 13
Optionally, the settling time can be evaluated and displayed, see Chapter 5.6.7, "Set-
tling time", on page 79.
Remote command:
LAY:ADD? '1',RIGH,'XTIM:FM'
(See LAYout:ADD[:WINDow]? on page 237)
PM Time Domain
Displays the phase deviations of the demodulated PM signal (in rad or °) versus time.
Optionally, the settling time can be evaluated and displayed, see Chapter 5.6.7, "Set-
tling time", on page 79.
Remote command:
LAY:ADD? '1',RIGH,'XTIM:PM'
(See LAYout:ADD[:WINDow]? on page 237)
AM Spectrum
Displays the modulation depth of the demodulated AM signal (in % or dB) versus AF
span. The spectrum is calculated from the demodulated AM signal in the time domain
via FFT.
Measurements and result displays
R&S®VSE-K7
18User Manual 1176.8939.02 ─ 13
Note: If a high pass or low pass AF filter is defined, the filter is indicated by a vertical
red line in the spectrum display.
Remote command:
LAY:ADD? '1',RIGH,'XTIMe:AM:REL:AFSPectrum1'
(see LAYout:ADD[:WINDow]? on page 237)
FM Spectrum
Displays the frequency deviations of the demodulated FM signal (in Hz or dB) versus
AF span. The spectrum is calculated from the demodulated AM signal in the time
domain via FFT.
Measurements and result displays
R&S®VSE-K7
19User Manual 1176.8939.02 ─ 13
Note: If a high pass or low pass AF filter is defined, the filter is indicated by a vertical
red line in the spectrum display.
Remote command:
LAY:ADD? '1',RIGH,'XTIMe:FM:AFSPectrum1'
(see LAYout:ADD[:WINDow]? on page 237)
PM Spectrum
Displays the phase deviations of the demodulated PM signal (in rad, ° or dB) versus
AF span. The spectrum is calculated from the demodulated AM signal in the time
domain via FFT.
Note: If a high pass or low pass AF filter is defined, the filter is indicated by a vertical
red line in the spectrum display.
Measurements and result displays
R&S®VSE-K7
20User Manual 1176.8939.02 ─ 13
Remote command:
LAY:ADD? '1',RIGH,'XTIMe:PM:AFSPectrum1'
(see LAYout:ADD[:WINDow]? on page 237)
RF Time Domain
Displays the RF power of the input signal versus time. The level values represent the
magnitude of the I/Q data set.
Optionally, the settling time can be evaluated and displayed, see Chapter 5.6.7, "Set-
tling time", on page 79.
Remote command:
LAY:ADD? '1',RIGH,'XTIM:AM'
(see LAYout:ADD[:WINDow]? on page 237)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341

Rohde&Schwarz VSE User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI