American Standard 2064.451.002 Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

American Standard 2064.451.002 is a wall-mount faucet designed for lavatories, offering precise water control and a stylish addition to any bathroom. Its durable construction ensures longevity, while the 2-handle design provides easy and independent temperature and volume adjustment. The faucet features a spout reach of 4 inches, allowing for ample sink coverage. The included aerator promotes a water-saving flow rate of 1.2 gallons per minute without compromising water pressure. Installation is made convenient with the in-wall lavatory fitting, providing a clean and seamless look.

American Standard 2064.451.002 is a wall-mount faucet designed for lavatories, offering precise water control and a stylish addition to any bathroom. Its durable construction ensures longevity, while the 2-handle design provides easy and independent temperature and volume adjustment. The faucet features a spout reach of 4 inches, allowing for ample sink coverage. The included aerator promotes a water-saving flow rate of 1.2 gallons per minute without compromising water pressure. Installation is made convenient with the in-wall lavatory fitting, providing a clean and seamless look.

Certified to comply with ASME A112.18.1M
U.S. Patent No. 5,819,789
HOT
COLD
Turn off hot and cold water
supplies before beginning.
CAUTION
Installation
Instructions
2064.451
ROUGHING-IN DIMENSIONS
1
2" D.
(52mm)
1"
(25mm)
2" MIN.
(51mm)
3" MAX.
(76mm) MAX.
FINISHED
WALL
FINISHED
WALL
2" D.
(52mm)
9-1/4"
(235mm)
1/2" NPT INLETS
8"
(203mm)
4"
(102mm)
CROSS
HANDLE
1
INSTALL VALVE BODY
Determine where the finished wall location will be. This measurement
is very important! Note: The rough-in measurement from the finished
wall is; 2" minimum and 3" maximum. This is a 1" tolerance. See
rough-in illustration above.
Secure FAUCET BODY (1) to cross brace of wall structure
at required height using two wood screws.
Turn valves to off position. Turn hot and cold supplies on and
check fitting connections for leaks .
Complete wall construction.
WOOD SCREWS
HOT
COLD
CROSS BRACE
WALL STUDS
16"
M
A
X
W
A
L
L
M
I
N
1
-
5
/
8
"
D
E
E
P
M
A
X
W
A
L
L
M
I
N
1
-
5
/
8
"
D
E
E
P
Connect HOT water supply to left VALVE inlet and COLD water
supply to right VALVE inlet. Use pipe sealant or Teflon tape for
all threaded connections. For sweat connections, do not make
sweat connections directly to valve body. Damage to seals and
and valve cartridge may occur.
Required Tools
Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
2-1/8" D.
(54mm)
2" MAX. (51mm) MAX.
1-1/4" O.D.
(32mm) O.D.
Pipe Wrench
Teflon Tape
Plumbers' Putty or
Caulking
Tubing Cutter
WALL MOUNT FAUCET
IN-WALL LAVATORY FITTING
To ensure that your installation proceeds smoothly-please
read these instructions carefully before you begin.
Thank you for selecting American-Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--
please read these instructions carefully before you begin.
M968852 Rev.1.6 (5/19)
SERIN
®
M968852 Rev.1.6 (5/19)
4
3
INSTALL HANDLES
GROOVE
GROOVE
FINISHED WALL
1
1
4
8
9
5
6
7
4
2
DRAIN INSTALLATION
Assembly GASKET (2) WASHER (3) and LOCKNUT (4) onto DRAIN BODY (1).
Tighten LOCKNUT (4) firmly.
Apply Teflon Tape to TAILPIECE (5) and thread onto DRAIN BODY (1).
Apply a bead of PUTTY to underside of FLANGE on DRAIN BODY (1).
Feed DRAIN BODY (1) down through lavatory.
LAVATORY
PUTTY
2
3
4
5
1
2
INSTALL WALL SPOUT
Remove PLASTER GUARDS (1) from valve bodies.
Inspect that SPOUT NIPPLE O-RING (2) is seated in groove of SPOUT NIPPLE (3).
Thread SPOUT MOUNT (4) onto SPOUT NIPPLE (3). Align groove on SPOUT MOUNT (4)
with face of finished wall. See Figure A.
Install SEAL (5) into SPOUT ESCUTCHEON (6). Place SPOUT
ESCUTCHEON (6) with SEAL (5) onto SPOUT MOUNT (4).
Push SPOUT (7) onto SPOUT MOUNT (4). Align SPOUT (7)
and tighten SPOUT SET SCREW (8) with 3mm HEX WRENCH
(9) supplied.
Figure A
1
M
A
X
W
A
L
M
I
N
1
-
5
/
8
"
D
E
M
A
X
W
A
L
L
M
I
N
1
-
5
/
8
"
D
E
E
P
3
1
5
2
3
4
Thread HANDLE BASE (4) onto HANDLE ESCUTCHEON (3)
until seated tightly against HANDLE ESCUTCHEON (3).
Place O-RING (2) into HANDLE ESCUTCHEON (3).
Thread HANDLE ESCUTCHEON (4) onto VALVE (5) until
snug against finished wall.
Turn VALVE STEMS (1) to off position.
M968852 Rev.1.6 (5/19)
6
TEST INSTALLED FAUCET
7
Turn HANDLES to "off" position.
Remove AERATOR (1) using TOOL (2) supplied.
Check all drain connections for leaks.
Turn handles to OFF position. Replace AERATOR (1).
Turn hot and cold water supplies on. Operate
both HANDLES to flush water lines thoroughly.
Check spout connections for leaks.
TO REMOVE
HANDLE
90˚
5
To change direction of handle rotation,
proceed as follows:
Turn valve to OFF position.
Thread counter-clock wise HANDLE BASE (1) to remove
HANDLE ASSEMBLY (2) from ESCUTCHEON BASE (3).
Use a flat blade screw driver to remove SPRING CLIP (4).
Lift STOP WASHER (5), turn 90˚ and replace.
Replace SPRING CLIP (4).
Reinstall HANDLE ASSEMBLY (2).
If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.
SERVICE
3
2
5
1
1
4
2
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
M968852 Rev.1.6 (5/19)
SERIN
®
WALL MOUNT
LAVATORY FAUCET
MODEL NUMBER
M950245-YYY0A
HANDLE ASSEMBLY
M962424-YYY0A
HANDLE ESCUTCHEON KIT
015025-YYY0A
DRAIN COMPLETE
070532-0040A
TAILPIECE
M962423-YYY0A
SPOUT ESCUTCHEON KIT
918555-0070A
HANDLE SCREW
617852-0070A
ADAPTER
994053-0070A
CARTRIDGE
621423-0070A
VALVE HOUSING
CHROME
SATIN NICKEL
002
295
Replace the "YYY" with
appropriate finish code
2064.451
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST
Saturday 10:00 a.m. to 4:00 p.m. EST
IN CANADA 1-800-387-0369
(TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
M970004-0070A
AERATOR KIT
(1.2 GPM)
M968852 FR Rév.1.6 (5/19)
SERIN
®
MONTAGE MURAL
POUR LAVABO
NUMÉRO DU MODÈLE
M950245-YYY0A
POIGNÉE
M962424-YYY0A
ROSACE DE POIGNÉE
015025-YYY0A
ÉVACUATION COMPLÈTE
070532-0040A
PIÈCE DE
RACCORDEMENT
M962423-YYY0A
ENSEMBLE ROSACE POUR BEC
918555-0070A
VIS DE LA POIGNÉE
617852-0070A
ADAPTATEUR
994053-0070A
CARTOUCHE
621423-0070A
BOÎTIER DE VANNE
CHROME
NICKEL SATINÉ
002
295
Remplacer les lettres « YYY »
par le code de fini approprié
2064. 451
LIGNE D’URGENCE
Pour obtenir des renseignements ou une réponse à vos questions,
composez sans frais le :
1 (800) 442-1902
Du lundi au vendredi de 8 h à 20 h, HNE
Samedi 8 h à 16 h, HNE
AU CANADA 1-800-387-0369
(TORONTO 1-905-306-1093)
En semaine de 8 h à 19 h, HNE
AU MEXIQUE 01-800-839-1200
M970004-0070A
TROUSSE DE LA
AÉRATEUR
(1.2 GPM)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

American Standard 2064.451.002 Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

American Standard 2064.451.002 is a wall-mount faucet designed for lavatories, offering precise water control and a stylish addition to any bathroom. Its durable construction ensures longevity, while the 2-handle design provides easy and independent temperature and volume adjustment. The faucet features a spout reach of 4 inches, allowing for ample sink coverage. The included aerator promotes a water-saving flow rate of 1.2 gallons per minute without compromising water pressure. Installation is made convenient with the in-wall lavatory fitting, providing a clean and seamless look.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI