FEGHI JKLMNOPQRS
n.u. n.u. n.u.
TUV
L1
GND
L2/N
L1
115V
L2/N
NOCNC
CNO
5678910 11 12 13 14 15 16 17 18 19 20 21 22
0-10V 0-10V
4-20mA
GND GNDGNDVDC VDC VDCCOM
GNDOUT PWR
Power
ABCD
[21] →
[20] →
[19] →
[Q] →
[R] →
[S] →
[R] →
[C] →
[D] →
[C] →
← [1]
T°
T°
T°
T°
T°
T°
T°
T°
T°
NH3
← [3]
← [2]
ABGND ABGND
ABGND
ABGND
1234
V-MAX
1234
A
Please scan the QR Code to access the complete manual or
visit the website.
Cumberland: http://www.cumberlandpoultry.com
GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc
Canada J3Z 1G5 • Phone: 1-877-926-2777
WIRING DIAGRAM
V-MAX
#891-00488 REV 05
REV 09
EN
Page 1
Digital input 1
(water meter, feeder or auger)
Digital input 2
(water meter, feeder or auger)
Digital input 3
(water meter, feeder or auger)
Digital input 4
(water meter, feeder or auger)
Digital input 5
(water meter, feeder or auger)
Digital input 7
(water meter, feeder or auger)
Digital input 6
(water meter, feeder or auger)
Digital input 8
(water meter, feeder or auger)
USB Connector
(for memory card)
> Module
Connections:
See Overleaf
Dwyer gauge static
pressure probe (opt.)
0-10V Load 1 (opt.) 0-10V Load 2 (opt.)Relative
humidity sensor
HS-1 (Optional)
115/230 Vac
Voltage Selector 6
Controller
Power Supply
115/230Vac
Alarm
Supply
Inside T°
probe 2
Inside T°
probe 1
Inside T°
probe 3
Inside T°
probe 4
Inside T°
probe 5 (opt.)
Inside T°
probe 6 (opt.)
Inside T°
probe 7 (opt.)
Inside T°
probe 8 (opt.)
Outside T
probe (opt.)
Ammonia
probe (opt.)
1. Mounting Instructions: Leave a
clearance of at least 16ʺ (400 mm) to the left of the
controller box to allow the cover to be removed
for maintenance.
2. Cable Entry: Punch holes at the bottom of
the enclosure to allow wires to be introduced in
the controller. Do not drill the top or side panels
of the enclosure.
3. Alarm System: Installation of a good quality
alarm system is strongly suggested to warn of
power failures and high/low temperatures.
4. Surge Protection: Provide a surge
protection (including lightning protection) from
the power supply to the controller and from
the control to the probes. Consult a certied
electrician if required.
5. Low Voltage Wires: Install low voltage
cables at least 12 inches (300 mm) away from
high voltage cables (120, 230 or 380 Vac or
24 Vdc). Always use twisted shielded cables
to wire low voltage devices and always cross
high and low voltage cables at a 90° angle.
This applies to:
- Sensor cables
- Potentiometer cables
- Communication cables
- Computer link cables
- 0-10V loads
- All other low voltage devices.
6. Voltage Selection: Set the voltage selector
to the proper position : 115 or 230Vac.
7. Water Meter: The water meter output
should be a dry contact and should not pulse
faster than 60 times a second (60Hz). A 22/12
AWG gauge cable no longer than 2000 feet
(0.6 km) can be used to connect the water
meter. Do not use a cable longer than 2000 feet
even if a larger cable is used. Do not run the
meter cable outside the building!
8. SureLink-2 Module: Refer to the user’s
manual of the SureLink-2 module to set the “End
of line (EOL)” selectors properly.
9. Digital Inputs: The function of each digital
input must be dened in the “Digital Input” tab of
the controller.
INSTALLATION NOTES
SureLink-2 module 9
A-BOX (opt.)
Relative
humidity probe
HP1, HS-100
(Old model)