Raymarine SeaTalk hs is an ethernet-based network that allows you to connect up to eight HS instruments together for data sharing.

Possible use cases:

  • Share data between instruments, such as depth, speed, and wind data.
  • Control instruments from a central location.
  • Monitor system performance and diagnostics.

Benefits:

  • Improved situational awareness and safety.
  • Increased efficiency and productivity.
  • Reduced installation and maintenance costs.

Raymarine SeaTalk hs is an ethernet-based network that allows you to connect up to eight HS instruments together for data sharing.

Possible use cases:

  • Share data between instruments, such as depth, speed, and wind data.
  • Control instruments from a central location.
  • Monitor system performance and diagnostics.

Benefits:

  • Improved situational awareness and safety.
  • Increased efficiency and productivity.
  • Reduced installation and maintenance costs.
SeaTalk
Network
Switch
Tie-wraps x (10)
No8 x 3/4 inch
pan-head self-
tapping screw
(x2)
Philips
screwdriver
3mm
(1/8 in)
Drill
Power
drill
HS
SeaTalk Network Switch
Installation Guide
www.raymarine.com
Welcome to the SeaTalk HS Network Switch
What's in the box?....
Tools Required
Intended Use
The intended application is for leisure marine boats and
workboats not covered by IMO/SOLAS carriage requirements.
HS
Where can I install the unit?
10˚ 10˚
MIN
MAX
-10
55
14
130
or
This guide shows how to install the Raymarine SeaTalk
Network Switch, which enables you to connect up to eight
instruments together using SeaTalk , an ethernet-based network,
for data sharing.
HS
HS
D7558_1
87046_2.fm Page 1 Thursday, January 24, 2008 2:53 PM
Important Information
Safety notices
WARNING: Navigation aid
Although this product has been designed to be accurate and reliable, many factors can affect its
performance. As a result, it should only be used as an aid to navigation and should never replace
common sense and navigational judgement. Always maintain a permanent watch so you can
respond to situations as they develop.
WARNING: Product installation
This equipment must be installed and operated in accordance with the instructions contained in
this guide. Failure to do so could result in poor product performance, personal injury and/or
damage to your boat.
WARNING: Electrical safety
Make sure the power supply is switched off before you make any electrical connections.
EMC conformance
All Raymarine equipment and accessories are designed to the best industry standards for use in the recreational
marine environment. The design and manufacture of Raymarine equipment and accessories conforms to the
appropriate Electromagnetic Compatibility (EMC) standards, but correct installation is required to ensure that
performance is not compromised. For full details and installation guidelines refer to or web site at
www.raymarine.com/support.
CE conformity
This product is labeled with the CE conformity mark:
Warranty
To register your new Raymarine product, please take a few minutes to fill out the warranty card.It is important that
you complete the owner information and return the card to us to receive full warranty benefits.
Your product can also be registered via our web site www.raymarine.com
.
HS
D7559_1
Vertical
Installing the unit
x2
Check
1
2
3
x2
x2
a
b
c
6 mm
minimum
D7599_1
87046_2.fm Page 2 Thursday, January 24, 2008 2:53 PM
Connecting the unit
LED diagnostics
Your network switch can be operated at either 12 V or 24 V DC. If you do not have a dedicated fused
breaker in the power circuit, an in-line 1A quick blow fuse should be fitted to the positive (red) lead of
the power cable.
SeaTalk system cables can be fitted to any connector. Push-fit the connectors until they clip into position.
SeaTalk cables
HS
Use a flat-blade scrwdriver to open the connector. Insert the cable,
and remove the screwdriver, this will make the connection.
Each of the switch sockets has 2 green LED's.
These indicate the status of the connection to the network switch
as follows:
a
a a
a
b
b
b
b
a - low speed connection
b - high speed connection
a - flashing, b - no light - low speed data transfer
a - flashing, b - steady - high speed data transfer
HS
CGND
NEG
POS
Use a cable-tie to secure cables in position
Power
cable
CGND
NEG
POS
D7560_1
87046_2.fm Page 3 Thursday, January 24, 2008 2:53 PM
Raymarine Incorporated
21 Manchester Street
Merrimack, New Hampshire 03054 - 4801
USA
Tel: 603-881-5200
Fax: 603-864-4756
www.raymarine.com
Document No: 87046_2
Date: March 2006
Raymarine 2006
Raymarine UK Limited
Quay Point, Northarbour Road,
Portsmouth, Hampshire
England PO6 3TD
Tel: + 44 (0)23 9269 3611
Fax: + 44 (0)23 9269 4642
www.raymarine.com
Maintenance and disposal....
Maintenance
This product does not contain any user serviceable parts. Maintenance is limited to the following checks:
Make sure all cables and connectors are firmly attached.
Examine all cables for signs of wear or damage.
Replace any damaged or worn cables.
To get Technical Support....
www.raymarine.com
United States
Raymarine Technical Services
1-800-539-5539 extension 2333, or
(603)-881-5200
Raymarine Technical Support
1-800-539-5539 extension 2444, or
(603) -881-5200
Product Repair and Service
Raymarine Product Repair Center
21 Manchester Street,
Merrimack, NH03654 - 4801
1-800-539-5539
Opening hours:
Monday through Friday 0815 - 1700 Eastern Standard or Eastern Daylight Savings Time.
Europe
Technical Support
Services
Accessories
Raymarine Limited
Anchorage Park
Portsmouth
PO3 5TD
England
Tel:
+44(0)23 9271 4713
Fax:
+44(0)23 9266 1228
D7561_1
Help us to help you
When requesting service, please quote the following product information:
Equipment type Model number Serial number
The Waste Electrical and Electronic Equipment (WEEE) Directive requires the recycling of waste
electrical and electronic equipment. Whilst the WEEE Directive does not apply to some of Raymarine's
products, we support its policy and ask you to be aware of how to dispose of this product. The crossed
out wheelie bin symbol, illustrated above, and found on our products signifies that this product should
not be disposed of in general waste or landfill. Please contact your local dealer, national distributor or
Raymarine Technical Services for information on product disposal.
Waste Electrical and Electronic Equipment Directive
87046_2.fm Page 4 Thursday, January 24, 2008 2:53 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Raymarine SeaTalk hs Installation guide

Type
Installation guide

Raymarine SeaTalk hs is an ethernet-based network that allows you to connect up to eight HS instruments together for data sharing.

Possible use cases:

  • Share data between instruments, such as depth, speed, and wind data.
  • Control instruments from a central location.
  • Monitor system performance and diagnostics.

Benefits:

  • Improved situational awareness and safety.
  • Increased efficiency and productivity.
  • Reduced installation and maintenance costs.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI