SolarEdge Installation Guide, Errata
MAN-01-00092-1.0
SolarEdge Installation Guide,
Errata
The following explains how to connect Ethernet wires to the inverter Ethernet terminal
block. These instructions replace pages 50-53 of the SolarEdge Installation Guide V2.0
and pages 72-75 of the SolarEdge Installation Guide North America V1.6.
1. Insert the Ethernet CAT5/6 cable through the appropriate communication
gland.
2. Remove the cable’s external isolation using the crimping tool or cable cutter
and expose eight wires. Standard cables have eight wires (four twisted pairs), as
shown in the diagram below.
Figure 1: Preparing Connector Wiring
3. The inverter has an eight-pin terminal block connector for Ethernet
communication. Pull it out, as shown below:
Figure 2: Removing the Ethernet Terminal Block