American Standard CERATHERM T050110 Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

6-11/16"
9-1/8"
1-11/16" to 2-1/2"
CENTRAL THERMOSTAT
LESS VOLUME CONTROL
TRIM KIT
Installation
Instructions
M968265
T050110
T050120
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1M
ASSE 1016
ROUGHING-IN DIMENSIONS
T
O
P
/
O
B
E
N
60
Recommended Tools
Flat Blade Screwdriver
Phillips Screwdriver
Remove as much surface dirt and film using clear
water and soft cotton cloth (as described above).
Use any of the following to remove tough surface
film and build-up:
Mild liquid detergents
Clear ammonia free liquid glass cleaners
Non-acidic, non-abrasive gentle liquid or fully
dissolved powder cleansers mixed according to
manufacturers directions.
Non-abrasive liquid polishers
Once clean, rinse faucet again with clear water to
thoroughly remove cleaner or polish and blot dry with
a soft cotton cloth.
To keep your new faucet looking new, please follow
these simple care instructions:
DO: Simply rinse the faucet clean with clear water.
Dry the faucet with a soft cotton cloth.
DO NOT:
Do not use any abrasive cleaners, cloths, or
paper towels.
Do not use any cleaning agents containing
acids, polish abrasives, or harsh cleaners or
soaps.
Regular and routine cleaning will reduce the need for
heavy cleaning and polishing. If heavy cleaning is
required, the following procedures are recommended:
CARE INSTRUCTIONS:
Failure to follow these care instructions may
damage the Faucet's finish.
FINISHED
WALL
C
L
100
1
1
1
3
5
2
4
3
5
6
1
3
4
5
2
TEMPERATURE CALIBRATION
SET HOT LIMIT STOP
5
Check that arrow marking B points vertically upwards. If not, push the BLACK
CLAMP (1) on the SECURING RING (2) to the right, pull off KNOB MOUNT (3)
and reinstall KNOB MOUNT (3) with arrow "B" pointing upwards.
For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT (3) until the spout
temperature is 100 F. Check that arrow marking A on the KNOB MOUNT (3) still points
upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE (5).
Remove KNOB MOUNT (3) without turning by sliding out as indicated by the arrow.
Reinstall the KNOB MOUNT (3) so that the arrow marking A points upwards.
The maximum mixed water temperature is set at 109 F at the factory.
This setting can be changed if desired.
Remove the TEMPERATURE LIMIT STOP (4) (H shaped Black Plastic part).
Reinstall it at the desired notch as indicated in the diagram to limit the maximum
mixed water temperature to 104 F or 112 F.
Reinstall RED LOCKING DEVICE (5).
ARROW
"A"
ARROW
"B"
104
109
112
M968265
OPERATING THE VALVE
4
1
Push CAP (1) over the O-RING SEAL (2).
TRIM INSTALLATION
Push on ESCUTCHEON (5) and attach with (60mm)
SCREWS (6) to valve body.
100
T
O
P
/
O
B
E
N
GREASE ESCUTCHEON
HOLDER O-RING SEAL
If a temperature over 100 F is desired, pull the RED STOP BUTTON (1) away from the body
of the MIXER UNIT and turn the TEMPERATURE KNOB.
If the system is delivering all Hot or all Cold and no mixed water the pipes are probably transposed.
This will increase the mixed water temperature up to the maximum limit previously
selected in step 4.
Push ESCUTCHEON HOLDER (3) with lightly greased
O-RING SEAL (4) over CAP (1).
SCREW DRIVER GAP
2
HANDLE INSTALLATION
Push TEMPERATURE-CONTROL KNOB (1) (with the red stop on top)
onto KNOB MOUNT (2).
Install HANDLE RING (3) and tighten CONTROL KNOB (1) with
HANDLE RING (3) in place using HANDLE SCREW (4).
Install KNOB CAP (5), (gap for screwdriver for use when
disassembling should point downwards).
1
0
0
2
4
Should the hot and cold water supply pipes have been transposed making
adjustment impossible, proceed as follows:
TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION
3
Remove check stops and re-install them transposed.
Shut off water supply.
Remove handle and rim
CHECK STOP
(RED TO BLUE)
Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE
CHECK STOP is now on the left.
Turn the water supply back on and perform the temperature adjustment in step 4.
CHECK STOP
(BLUE TO RED)
T
O
P
/
O
B
E
N
100
907065-YYY0A
HANDLE CAP
918416-0070A
SCREW
909750-YYY0A
HANDLE RING
953976-YYY0A
TEMPERATURE
CONTROL HANDLE BASE
953961-0070A
ESCUTCHEON
CARRIER
918327-0070A
ESCUTCHEON
CARRIER SCREWS
918378-YYY0A
ESCUTCHEON SCREWS
060441-YYY0A
TEMPERATURE
CONTROL HANDLE
953947-YYY0A
ESCUTCHEON
907090-YYY0A
CAP
913981-0070A
SEAL
MODEL NUMBERS
M968265
CHROME
POLISHED BRASS
SATIN
CHR/POL. BRASS (MIXAGE)
002
099
295
299
Replace the "YYY" with
appropriate finish code
CENTRAL THERMOSTAT
LESS VOLUME CONTROL
TRIM KIT
T050110
T050120
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2003
ROUGH VALVE KIT
CENTRAL THERMOSTAT
LESS VOLUME CONTROL
Installation
Instructions
M968256A
R510
R530
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1M
ASSE 1016
ROUGHING-IN DIMENSIONS
FINISHED FLOOR
FINISHED
WALL
1-11/16"
to
2-1/2"
1/2" NPT OUTLETS FOR R510
3/4" NPT OUTLETS FOR R530
1/2" NPT OUTLETS FOR R510
3/4" NPT OUTLETS FOR R530
5-7/8"
3-3/8"
T
O
P
C
L
NOTE:
TO OPERATE ALL FOUR OUTLETS AT THE SAME
TIME THE MINIMUM REQUIREMENTS ARE:
48" TO 54"
FOR SHOWER ONLY
(OPTIONAL)
32" TO 42"
FOR BATH/SHOWER
AND BATH FILLER
(OPTIONAL)
TUB PORT MUST
BE PLUGGED
HOT
COLD
1/2" or 3/4"
inlet
1/2" or 3/4"
inlet
1/2" or 3/4"
inlet
1/2" or 3/4"
inlet
(2) On/Off
Volume
Control Valves
(3) On/Off
Volume
Control Valves
TUB PORT MUST
BE PLUGGED
HOT
COLD
1/2" or 3/4"
inlet
1/2" or 3/4"
inlet
On/Off
Volume
Control Valve
TUB PORT MUST
BE PLUGGED
HOT
COLD
3/4"
FLOWING PRESSURE OF 40 PSI WITH R510
FLOWING PRESSURE OF 20 PSI WITH R530
INLET AND OUTLET CONNECTIONS ARE
1/2" NPT FOR R510
INLET AND OUTLET CONNECTIONS ARE
3/4" NPT FOR R530
INLET AND OUTLET CONNECTIONS ARE
1/2" NPT FOR R510
INLET AND OUTLET CONNECTIONS ARE
3/4" NPT FOR R530
INLET AND OUTLET CONNECTIONS ARE
1/2" NPT FOR R510
INLET AND OUTLET CONNECTIONS ARE
3/4" NPT FOR R530
THERMOSTATIC SHOWER
INSTALLATION USING ONE
ON/OFF VALVE AND FIXED
SHOWER
THERMOSTATIC SHOWER INSTALLATION
USING TWO ON/OFF VALVES, FIXED
SHOWER AND ADJUSTABLE HAND
HELD SHOWER
THERMOSTATIC SHOWER INSTALLATION
USING THREE ON/OFF VALVES, FIXED
SHOWER, ADJUSTABLE HAND HELD
SHOWER AND TWO BODY SPRAYS
TO
P
T
OP
M968256A
CHECK STOP
(HOT RED)
PLUG TUB
PORT
CHECK STOP
(COLD BLUE)
TEMPERATURE CALIBRATION
3
Unscrew PLASTER GUARD SCREWS and remove PLASTER GUARD.
Check that arrow marking B points vertically upwards. If not, push the BLACK
CLAMP on the SECURING RING to the right, pull off KNOB MOUNT and reinstall
KNOB MOUNT with arrow "B" pointing upwards.
For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT until the spout
temperature is 100 F. Check that arrow marking A on the KNOB MOUNT still points
upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE.
Remove KNOB MOUNT by pulling it towards you while standing directly in front of the valve.
Reinstall the KNOB MOUNT so that the arrow marking A points upwards.
The maximum mixed water temperature is set at 109 F at the factory.
This setting can be changed if desired.
Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Reinstall it
at the desired notch as indicated in the diagram to limit the maximum mixed water
temperature to 104 F or 112 F.
Reinstall RED LOCKING DEVICE.
KNOB
MOUNT
ARROW
"A"
BLACK
CLAMP
ARROW
"B"
RED LOCKING
DEVICE
SECURING
RING
104
109
112
TEMPERATURE
LIMIT STOP
Turn off hot and cold water
supplies before beginning.
CAUTION
WARNING
1
Prepare water supplies per ROUGHING-IN DIMENSIONS. Make sure
the finished wall is between the minimum 1-11/16" and maximum 2-1/2" rough dimension.
ROUGHING-IN THE VALVE
Install VALVE (1) at indicated height and depth. Make sure the "TOP" marking on the PLASTER
GUARD (2) is up. For support, use pipe BRACES (3) secured to wooden braces.
Connect the hot and cold water supplies. Assemble all connecting pipes. Close off the tub
port if it is not needed using a commercially available pipe plug. Connections are 1/2" NPT
or 3/4" NPT.
IMPORTANT! INSTALL ANY REQUIRED SHUT OFF OR DIVERTER VALVE INTO THE PIPING SYSTEM.
DO NOT SOLDER DIRECTLY TO THE VALVE BODY (1); THIS WILL DAMAGE
THE TEMPERATURE CONTROL ELEMENT AND CHECK STOP VALVES.
If the CHECK STOPS (4, 5) were removed during installation, ensure the hot and cold
CHECK STOPS (4, 5) are not reversed. The hot CHECK STOP (4) has a red top and the cold
CHECK STOP (5) has a blue top.
CHECK STOPS (4,5) are supplied in the open position. Closing using 5/32" (4 mm) hex
wrench to pressure test and to check for leaks.
Reassemble PLASTER GUARD (2) and FINISH WALL.
Beware of Freezing. No water should remain in the MIXING VALVE if freezing is a possibility.
Remove the CHECK STOPS (4,5) to completely drain the MIXER UNIT (1).
Remove PLASTER GUARD (2) if still installed. Turn on water supplies and check for leaks.
To flush lines, remove the CHECK STOPS (4,5) and run water. If desired, the TEMPERATURE CONTROL UNIT
can be removed. Reinstall CHECK STOPS (4,5) and CONTROL UNIT (6), if it was removed.
COLD
HOT
COLD
HOT
1
3
2
4
WOOD BRACE
5
6
Should the hot and cold water supply pipes
have been transposed making adjustment
impossible, proceed as follows:
TRANSPOSED SUPPLY PIPING
OR BACK TO BACK INSTALLATION
2
Remove check stops and
re-install them transposed.
Shut off water supply.
Remove handle and rim
CHECK STOP
(RED TO BLUE)
Important note: RED CHECK
STOP is now on the right of the
mixer body and the BLUE
CHECK STOP is now on the left.
Turn the water supply back on
and perform the temperature
adjustment in step 3.
CHECK STOP
(BLUE TO RED)
M968256A
MODEL NUMBERS
CENTRAL THERMOSTAT
LESS VOLUME CONTROL
R510
R530
953963-0070A
HANDLE
EXTENSION
953957-0070A
TEMPERATURE
CALIBRATION
UNIT
A953971-0070A
CHECK STOP R530
(COLD BLUE)
953951-0070A
CHECK STOP R510
(HOT RED)
912647-0070A
O-RING
A954820-0070A
THERMOSTAT CARTRIDGE
R510
954040-0070A
THERMOSTAT CARTRIDGE
R530
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2003
963434-0020A DEEP ROUGH KIT
SOLD SEPARATELY
953950-0070A
CHECK STOP R510
(COLD BLUE)
A953972-0070A
CHECK STOP R530
(HOT RED)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

American Standard CERATHERM T050110 Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI