IM703-A

Lincoln Electric IM703-A, PRECISION TIG 375 User manual

  • Hello! I am an AI chatbot trained to assist you with the Lincoln Electric IM703-A User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
PRECISION TIG 375
OPERATOR’S MANUAL
IM703-A
November, 2004
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thoughtful
operation on your part. DO NOT
INSTALL, OPERATE OR REPAIR
THIS EQUIPMENT WITHOUT
READING THIS MANUAL AND
THE SAFETY PRECAUTIONS
CONTAINED THROUGHOUT.
And, most importantly, think before
you act and be careful.
For use with machines having Code Numbers:
10809; 10810; 10894
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
Copyright © 2004 Lincoln Global Inc.
Precision TIG 375 Welding
Package shown with optional
Advanced Control Panel
IP21S
This manual covers equipment which is no
longer in production by The Lincoln Electric Co.
Specications and availability of optional
features may have changed.
FOR ENGINE
powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance
work unless the maintenance work requires it to be running.
____________________________________________________
1.b.Operate engines in open, well-ventilated
areas or vent the engine exhaust fumes
outdoors.
____________________________________________________
1.c. Do not add the fuel near an open flame weld-
ing arc or when the engine is running. Stop
the engine and allow it to cool before refuel-
ing to prevent spilled fuel from vaporizing on
contact with hot engine parts and igniting. Do
not spill fuel when filling tank. If fuel is spilled,
wipe it up and do not start engine until fumes
have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in posi-
tion and in good repair.Keep hands, hair, clothing and tools
away from V-belts, gears, fans and all other moving parts
when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove
guards only when necessary and replace them when the
maintenance requiring their removal is complete.
Always use the greatest care when working near moving
parts.
___________________________________________________
1.f. Do not put your hands near the engine fan.
Do not attempt to override the governor or
idler by pushing on the throttle control rods
while the engine is running.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while
turning the engine or welding generator during maintenance
work, disconnect the spark plug wires, distributor cap or
magneto wire as appropriate.
i
SAFETY
i
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you
purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040,
Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the
Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
WARNING
Mar ‘95
ELECTRIC AND
MAGNETIC FIELDS
may be dangerous
2.a. Electric current flowing through any conductor causes
localized Electric and Magnetic Fields (EMF). Welding
current creates EMF fields around welding cables and
welding machines
2.b. EMF fields may interfere with some pacemakers, and
welders having a pacemaker should consult their physician
before welding.
2.c. Exposure to EMF fields in welding may have other health
effects which are now not known.
2.d. All welders should use the following procedures in order to
minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure
them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right
side, the work cable should also be on your right side.
2.d.4. Connect the work cable to the workpiece as close as
possible to the area being welded.
2.d.5. Do not work next to welding power source.
1.h. To avoid scalding, do not remove the
radiator pressure cap when the engine is
hot.
For Diesel Engines: Diesel engine exhaust and
some of its constituents are known to the State
of California to cause cancer, birth defects, and
other reproductive harm.
For Gasoline Engines: The engine exhaust from
this product contains chemicals known to the
State of California to cause cancer, birth defects,
or other reproductive harm.
CALIFORNIA PROPOSITION 65 WARNINGS
ii
SAFETY
ii
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover
plates to protect your eyes from sparks and
the rays of the arc when welding or observing
open arc welding. Headshield and filter lens
should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant
material to protect your skin and that of your helpers from
the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable
screening and/or warn them not to watch the arc nor expose
themselves to the arc rays or to hot spatter or metal.
ELECTRIC SHOCK can kill.
3.a. The electrode and work (or ground) circuits
are electrically “hot” when the welder is on.
Do not touch these “hot” parts with your bare
skin or wet clothing. Wear dry, hole-free
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation.
Make certain the insulation is large enough to cover your full
area of physical contact with work and ground.
In addition to the normal safety precautions, if welding
must be performed under electrically hazardous
conditions (in damp locations or while wearing wet
clothing; on metal structures such as floors, gratings or
scaffolds; when in cramped positions such as sitting,
kneeling or lying, if there is a high risk of unavoidable or
accidental contact with the workpiece or ground) use
the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode,
electrode reel, welding head, nozzle or semiautomatic
welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical
connection with the metal being welded. The connection
should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical
(earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and
welding machine in good, safe operating condition. Replace
damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of
electrode holders connected to two welders because voltage
between the two can be the total of the open circuit voltage
of both welders.
3.i. When working above floor level, use a safety belt to protect
yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
FUMES AND GASES
can be dangerous.
5.a. Welding may produce fumes and gases
hazardous to health. Avoid breathing these
fumes and gases.When welding, keep
your head out of the fume. Use enough
ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
welding with electrodes which require special
ventilation such as stainless or hard facing (see
instructions on container or MSDS) or on lead or
cadmium plated steel and other metals or coatings
which produce highly toxic fumes, keep exposure as
low as possible and below Threshold Limit Values (TLV)
using local exhaust or mechanical ventilation. In
confined spaces or in some circumstances, outdoors, a
respirator may be required. Additional precautions are
also required when welding on galvanized steel.
5.b.
Do not weld in locations near chlorinated hydrocarbon
vapors
coming from degreasing, cleaning or spraying operations.
The heat and rays of the arc can react with solvent vapors
to
form phosgene, a highly toxic gas, and other irritating
products.
5.c. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation,
especially in confined areas, to insure breathing air is safe.
5.d. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the
material safety data sheet (MSDS) and follow your
employer’s safety practices. MSDS forms are available from
your welding distributor or from the manufacturer.
5.e. Also see item 1.b.
Mar ‘95
FOR ELECTRICALLY
powered equipment.
8.a. Turn off input power using the disconnect
switch at the fuse box before working on
the equipment.
8.b. Install equipment in accordance with the U.S. National
Electrical Code, all local codes and the manufacturer’s
recommendations.
8.c. Ground the equipment in accordance with the U.S. National
Electrical Code and the manufacturer’s recommendations.
CYLINDER may explode
if damaged.
7.a. Use only compressed gas cylinders
containing the correct shielding gas for the
process used and properly operating
regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for
the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely
chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
Away from areas where they may be struck or subjected to
physical damage.
A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other
electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet
when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand
tight except when the cylinder is in use or connected for
use.
7.g. Read and follow the instructions on compressed gas
cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.
iii
SAFETY
iii
Mar ‘95
WELDING SPARKS can
cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
the welding sparks from starting a fire.
Remember that welding sparks and hot
materials from welding can easily go through small cracks
and openings to adjacent areas. Avoid welding near
hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site,
special precautions should be used to prevent hazardous
situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the
equipment being used.
6.c. When not welding, make certain no part of the electrode
circuit is touching the work or ground. Accidental contact can
cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the
proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances
inside. They can cause an explosion even
though
they have
been “cleaned”. For information, purchase “Recommended
Safe Practices for the
Preparation
for Welding and Cutting of
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or
welding. They may explode.
6.f.
Sparks and spatter are thrown from the welding arc. Wear oil
free protective garments such as leather gloves, heavy shirt,
cuffless trousers, high shoes and a cap over your hair. Wear
ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a
welding area.
6.g. Connect the work cable to the work as close to the welding
area as practical. Work cables connected to the building
framework or other locations away from the welding area
increase the possibility of the welding current passing
through lifting chains, crane cables or other alternate circuits.
This can create fire hazards or overheat lifting chains or
cables until they fail.
6.h. Also see item 1.c.
vv
Thank You
for selecting a QUALITY product by Lincoln Electric. We want you
to take pride in operating this Lincoln Electric Company product •••
as much pride as we have in bringing this product to you!
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it
handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.
The level of seriousness to be applied to each is explained below:
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or
loss of life.
This statement appears where the information must be followed to avoid minor personal injury or damage to
this equipment.
CAUTION
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims
for material damaged in shipment must be made by the purchaser against the transportation company at the time
the shipment is received.
Please record your equipment identification information below for future reference. This information can be found
on your machine nameplate.
Product _________________________________________________________________________________
Model Number ___________________________________________________________________________
Code Number or Date Code_________________________________________________________________
Serial Number____________________________________________________________________________
Date Purchased___________________________________________________________________________
Where Purchased_________________________________________________________________________
Whenever you request replacement parts or information on this equipment, always supply the information you
have recorded above. The code number is especially important when identifying the correct replacement parts.
On-Line Product Registration
- Register your machine with Lincoln Electric either via fax or over the Internet.
• For faxing: Complete the form on the back of the warranty statement included in the literature packet
accompanying this machine and fax the form per the instructions printed on it.
• For On-Line Registration: Go to our
WEB SITE at www.lincolnelectric.com. Choose “Quick Links” and then
“Product Registration”. Please complete the form and submit your registration.
TABLE OF CONTENTS
Page.
Installation ..........................................................................................................Section A
Technical Specifications ........................................................................................A-1,A-2
Safety Precautions
.. ............................................................................................................................................... .A-3
Select Suitable Location........................................................................................A-3
Grinding .................................................................................................................A-3
Stacking.................................................................................................................A-3
Undercarriage Lifting and Moving .........................................................................A-3
Tilting .....................................................................................................................A-3
Environmental Rating ............................................................................................A-3
Machine Grounding and High F
REQUENCY INTERFERENCE PROTECTION ...................A-3,A-4
Input and Grounding Connections ..............................................................................A-4
Output Cable, Connections and Limitations ................................................................A-5
Work Cable Connection ..................................................................................A-5
Stick Electrode Cable Connection ..................................................................A-5
TIG Torch Connection .....................................................................................A-6
Auxiliary Power Connections ..........................................................................A-7
Remote Control (If Used) ................................................................................A-7
Robotic Interface Connection ..................................................................A-7, A-8
________________________________________________________________________
O
PERATION .........................................................................................................................................................Section B-1
Safety Precautions.......................................................................................................B-1
Product Description......................................................................................................B-1
Pipe Thawing.........................................................................................................B-1
Duty Cycle: ............................................................................................................B-1
Recommended Processes and Equipment ...........................................................B-2
Controls and Settings ..........................................................................B-3 THRU B-6
Internal Set Up Controls ........................................................................................B-7
Sick Welding Features...........................................................................................B-7
TIG Welding Features ...........................................................................................B-7
2 Step Trigger Modes......................................................................................B-8
4 Step Trigger Modes ....................................................................................B-9
TIG Welding Cycle Chart ....................................................................................B-10
Setup Guidelines for TIG Welding with an Amptrol.....................................B-10, B11
Making a TIG Weld with an Amptrol....................................................................B-12
________________________________________________________________________
Accessories
............................................................................................................................................... .......Section C
Optional Equipment .....................................................................................................C-1
________________________________________________________________________
Maintenance
......................................................................................................................................................Section D
Safety Precautions.......................................................................................................D-1
Routine and Periodic Maintenance..............................................................................D-1
Overload Protection .....................................................................................................D-1
Service Procedures, Component Access,Spark Gap Adjustment ...............................D-2
Under-Cooler Service ..................................................................................................D-2
________________________________________________________________________
Troubleshooting
.............................................................................................................................................Section E
Safety Precautions.......................................................................................................E-1
How To Use TroubleShooting Guide............................................................................E-1
Troubleshooting.................................................................................................E-2 to E-7
________________________________________________________________________
Diagrams
..............................................................................................................................................................Section F
Wiring Diagrams..............................................................................................................................................F-1, F-2
Dimension Prints.............................................................................................................................................F-3, F-4
________________________________________________________________________
Parts List
........................................................................................................................................................................P404
vivi
A-1
INSTALLATION
PRECISION TIG 375
A-1
TECHNICAL SPECIFICATIONS-
PRECISION TIG 375 (K1903-1 Domestic Package*-60Hz)
(K1833-1 Domestic,K1833-2 Canadian-60Hz) (K1834-1 Export-50/60Hz)
Voltage + 10%
208/230/460
230/460/575
220-230/
380-400/415
Max. Amps With Power Factor Capacitor
112/102/51
139/126/63
102/92/46
128/116/58
80/72/36
104/92/47
68/62/31
102/51/41
125/63/50
92/46/37
116/58/46
72/36/29
94/47/38
62/31/25
.86 min.
1.0KW
119/69/63
118/68/62
110/64/59
97/56/52
88/51/47
73/42/39
48/28/25
.67 min.
.8KW
Duty Cycle-Applications
40%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
60%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
100%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
Idle Amps
40%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
60%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
100%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
Idle Amps
Rated Power Factor (Stick)
Idle Power
40%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
60%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
100%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
Idle Amps
Rated Power Factor (Stick)
Idle Power
RATED INPUT - SINGLE PHASE ONLY
K
Number
K1833-1
K1903-1
K1833-2
K1834-1
RATED OUTPUT - NEMA EW1 Class ll (40) K1903-1,K1833-1,K1833-2
Duty Cycle-Applications
40%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
60%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
100%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
Volts at Rated Amperes
35.0
17.2
34.0
16.9
32.0
16.3
Amps
375
350
350
325
300
275
*Shown on Front of this IM manual with Under-Cooler Cart and Advanced Control Panel (Refer to Optional Equipment)
#
Exceeds NEMA Unbalanced Load Specification comparable for Auto-Balance.
R
R
NRTL/C
NRTL/C
IEC 60974-1
N80
K1833-1, -2
K1834-1
K1903-1
A-2
INSTALLATION
PRECISION TIG 375
A-2
ADDITIONAL OUTPUT CAPACITY
Output Current
Range
2Amps DC
to
420Amps AC-DC
*
Type of Output
CC (Constant Current)
AC/DC (GTAW)
Stick (SMAW)
Maximum Open
Circuit Voltage
(STICK AND TIG)
AC/DC OCV: 80
Auxiliary Power
K1903-1, K1833-1, K1833-2
15Amp Circuit Breaker and NEMA 5-15R Duplex
Receptacle for up to:
115VAC 8 Amp Auxiliary Power Receptacle
115VAC 5 Amp weld Switched Cooler Receptacle
K1834-1
5 Amp Circuit Breaker
and grounded 220VAC
Euro(Schuko) receptacle
Height Width Depth Weight
31.0 in. 22.0 in. 26.0 in. 507 lbs.
787 mm 559 mm 660 mm 230 kgs.
49.7 in. 28.0 in. 41.0 in. 751 lbs.
1262 mm 711 mm 1041 mm 341 kgs.
PHYSICAL DIMENSIONS
1
ALSO CALLED INVERSE TIME" OR "THERMAL/MAGNETIC " CIRCUIT BREAKERS; CIRCUIT BREAKERS WHICH HAVE A DELAY IN TRIPPING ACTION THAT DECREASES AS
THE MAGNITUDE OF CURRENT INCREASES.
*50/60HZ IEC Max. range exceeds 310A.
TEMPERATURE RANGES
OPERATING TEMPERATURE RANGE
-20°C to +40°C (-04° to +104°F)
TRANSFORMER INSULATION CLASS 180°C (H)
STORAGE TEMPERATURE RANGE
-40°C to +85°C (-40° to +185°F)
For all Stick, DC TIG, and Balanced AC TIG Welding
at 375A/40% Duty Cycle with out Standard Power
Factor Correction Capacitors
Based on the 1999 U.S. National Electrical Code
For Unbalanced AC TIG Welding Above 275 Amps:
350A/40% Duty Cycle, Auto-Balance Penetration with
out Standard Power Factor Correction Capacitors
Based on the 1999 U.S. National Electrical Code
RECOMMENDED INPUT WIRE AND FUSE SIZES
Input
Voltage /
phase/
Frequency
208/1/60
230/1/60
460/1/60
575/1/60
220-230/1/50/60
380-400/1/50/60
415/1/50/60
Input
Ampere
Rating
Rating on
Nameplate
112
102
51
41
119
69
63
Input
Ampere
Rating
139
126
63
50
118
68
62
Type 75°C
Copper
Ground Wire in
Conduit AWG
(IEC) Sizes
6 (13.3 mm
2
)
6 (13.3 mm
2
)
8 (8.4 mm
2
)
10 (5.3mm
2
)
6 (13.3 mm
2
)
6 (13.3 mm
2
)
6 (13.3 mm
2
)
Type 75°C
Copper
Ground Wire in
Conduit AWG
(IEC) Sizes
6 (13.3 mm
2
)
6 (13.3 mm
2
)
8 (8.4 mm
2
)
8 (8.4 mm
2
)
6 (13.3 mm
2
)
6 (13.3 mm
2
)
6 (13.3 mm
2
)
Fuse
(Super Lag)
or Breaker
Size
1
150
150
80
50
150
110
110
Fuse
(Super Lag)
or Breaker
Size
1
200
175
80
70
150
110
110
Type 75°C
Copper Wire in
Conduit AWG
(IEC) Sizes
40°C (104°F)
Ambient
3 (26.7 mm
2
)
3 (26.7 mm
2
)
6 (13.3mm
2
)
8 (8.4 mm
2
)
3 (26.7 mm
2
)
4 (21.2 mm
2
)
4 (21.2 mm
2
)
Type 75°C
Copper Wire in
Conduit AWG
(IEC) Sizes
40°C (104°F)
Ambient
1 (42.4 mm
2
)
2 (33.6 mm
2
)
6 (13.3 mm
2
)
6 (13.3 mm
2
)
3 (26.7 mm
2
)
4 (21.2 mm
2
)
4 (21.2 mm
2
)
RATED OUTPUT - IEC 60974-1 (K1834-1)
Duty Cycle-Applications
40%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
60%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
100%
AC/DC Stick / Balance TIG
Unbalance (70% Penetration
#
) AC TIG
Volts at Rated Amperes
35.0
24.0
34.0
23.0
32.0
21.0
Amps
375
350
350
325
300
275
A-3
INSTALLATION
PRECISION TIG 375
A-3
SAFETY PRECAUTIONS
SELECT SUITABLE LOCATION
Place the welder where clean cooling air can freely cir-
culate in through the top rear vents and out through the
bottom rear vents. Dirt, dust or any foreign material
that can be drawn into the welder should be kept at a
minimum. Failure to observe these precautions can
result in excessive operating temperatures and nui-
sance trips.
GRINDING
Do not direct grinding particles towards the welder. An
abundance of conductive material can cause mainte-
nance problems.
STACKING
The Precision TIG 375's cannot be stacked .
UNDERCARRIAGE LIFTING AND MOVING
When the Precision TIG 375 is purchased as a weld-
ing package, or used with any of the available
Undercarriage optional accessories, proper installation
makes the Precision TIG 375 lift bale nonfunctional.
Do not attempt to lift the power source with an under-
carriage attached. The undercarriage is designed for
hand moving only; mechanized movement can lead to
personal injury and/or damage to the Precision TIG
375.
TILTING
Each machine must be placed on a secure, level sur-
face, either directly or on a recommended undercar-
riage. The machine may topple over if this precaution
is not followed.
ENVIRONMENTAL RATING
Precision TIG 375 power sources carry an IP21S
Environmental rating. They are rated for use in damp,
dirty rain-sheltered environments.
MACHINE GROUNDING AND HIGH FRE-
QUENCY INTERFERENCE PROTECTION
The frame of the welder must be grounded. A ground screw
marked with the symbol is located on the input connection
panel (Figure A.1) for this purpose. See your local and nation-
al electrical codes for proper grounding methods.
The spark gap oscillator in the high frequency genera-
tor, being similar to a radio transmitter, can be blamed
for many radio, TV and electronic equipment interfer-
ence problems. These problems may be the result of
radiated interference. Proper grounding methods can
reduce or eliminate radiated interference.
The Precision TIG 375 has been field tested under rec-
ommended installation conditions and has been found
to comply with F.C.C. allowable radiation limits. This
welder has also been found to comply with NEMAstan-
dards for high frequency stabilized power sources.
Radiated interference can develop in the following four
ways:
Direct interference radiated from the welder.
Direct interference radiated from the welding leads.
Direct interference radiated from feedback into the
power lines.
Interference from re-radiation of "pickup" by
ungrounded metallic objects.
Keeping these contributing factors in mind, installing
the equipment per the following instructions should
minimize problems.
1. Keep the welder power supply lines as short as pos-
sible and completely enclose them in rigid metallic
conduit or equivalent shielding for a minimum dis-
tance of 50 feet (15.2 m). There must be good elec-
trical contact between this conduit and the welder.
Both ends of the conduit must be connected to a
driven ground and the entire length must be contin-
uous.
2. Keep the work and electrode leads as short as pos-
sible and as close together as possible. Lengths
should not exceed 25 feet (7.6 m). Tape the leads
together when practical.
Read entire installation section before starting
installation.
ELECTRIC SHOCK can kill.
Only qualified personnel should
perform this installation.
Turn the input power OFF at the
disconnect switch or fuse box
before working on this
equipment.
Do not touch electrically hot
parts.
Always connect the Precision TIG 375 grounding screw (behind
the reconnect panel cover located near the back of the left case
side) to a good electrical earth ground.
Always connect the Precision TIG 375 to a power supply
grounded in accordance with the National Electrical Code and
all local codes.
WARNING
INPUT and GROUNDING CONNECTIONS
Be sure the voltage, phase, and frequency of the input
power is as specified on the rating plate, located on the
rear of the machine.
Remove the reconnect panel cover located near the
back of the left case side to reveal the reconnect panel.
Welder supply line entry provision is in the case rear
panel. Entry is through a 1.75 inch (44 mm) diameter
hole in the case back. Appropriate supply line strain
relief clamp is provided by installer. (See Figure A.1)
All connections should be made in accordance
with all local codes and national electrical codes.
Installation by a qualified electrician is recom-
mended.
1. Connect the terminal marked (below the recon-
nect panel) to an earth ground.
2. Connect the input leads to terminals marked L1 (U)
and L2 (V) on the reconnect panel. Use a single
phase line or one phase of a two or three phase line.
3. On multiple input voltage welders, be sure the
reconnect panel is connected for the voltage being
supplied to the welder.
Failure to follow these instructions can cause
immediate failure of components within the welder.
------------------------------------------------------------------------
A-4
INSTALLATION
PRECISION TIG 375
A-4
3. Be sure the torch and work cable rubber coverings
are free of cuts and cracks that allow high frequen-
cy leakage. Cables with high natural rubber content,
such as Lincoln Stable-Arc® better resist high fre-
quency leakage than neoprene and other synthetic
rubber insulated cables.
4. Keep the torch in good repair and all connections
tight to reduce high frequency leakage.
5. The work terminal must be connected to a ground
within ten feet of the welder, using one of the fol-
lowing methods:
A metal underground water pipe in direct contact
with the earth for ten feet or more.
A 3/4" (19 mm) galvanized pipe or a 5/8" (16 mm)
solid galvanized iron, steel or copper rod driven at
least eight feet into the ground.
The ground should be securely made and the ground-
ing cable should be as short as possible using cable of
the same size as the work cable, or larger. Grounding
to the building frame electrical conduit or a long pipe
system can result in re-radiation, effectively making
these members radiating antennas. (This is not rec-
ommended).
6. Keep all access panels and covers securely in
place.
7. All electrical conductors within 50 feet (15.2 m) of
the welder should be enclosed in grounded rigid
metallic conduit or equivalent shielding. Flexible
helically-wrapped metallic conduit is generally not
suitable.
8. When the welder is enclosed in a metal building,
several good earth driven electrical grounds (as in 5
above) around the periphery of the building are rec-
ommended.
Failure to observe these recommended installation
procedures can cause radio or TV interference prob-
lems and result in unsatisfactory welding performance
resulting from lost high frequency power.
WARNING
ELECTRIC SHOCK can kill.
Turn the input power OFF at the
disconnect switch or fuse box
before working on this
equipment.
FIGURE A.1
CONNECT INPUT
POWER LEADS
CONNECT INPUT
VOLTAGE LEVEL
CONNECT INPUT
GROUND LEAD
CAUTION
A-5
INSTALLATION
PRECISION TIG 375
A-5
Recommended Cable Sizes for Combined Lengths of
Copper Work and Electrode Cables using 75
o
C Wire:
Machine Rating 0 to 100 Ft. 101 to 200 Ft 201 to 250 Ft
375A/40% #1 (42.4 mm
2
) 1/0 (53.5 mm
2
) 2/0 (67.4 mm
2
)
WORK CABLE CONNECTION
A15 (2/0) weld cable with clamp is available (K2150-1), or
included with the Precision TIG Welding Package model.
Otherwise, it is user provided.
With power source off, connect a separate work cable
to the 1/2-13 threaded "WORK" stud of the welder, and
secure a tight connection with the flange nut provided.
The work cable should be routed through the cable
strain relief hole provided in the base directly below the
welding output terminal.
Note: If the Precision TIG is equipped with an Under-
Cooler or Under-Storage unit, the coiled work cable
and clamp, or excess work cable length, may be con-
veniently stored in the drawer while remaining con-
nected.
STICK ELECTRODE CABLE CONNECTION
If manual stick welding is desired, with power source
off, connect a stick electrode cable to the 1/2-13
threaded "STICK Electrode" stud of the welder, and
secure a tight connection with the flange nut provided.
The electrode cable should be routed through the
cable strain relief hole provided in the base directly
below the welding output terminal.
DISCONNECT STICK ELECTRODE WELDING
CABLE WHEN TIG WELDING.
EVEN THOUGH HI-FREQ IS NOT APPLIED TO THE
PRECISION TIG STICK TERMINAL, IT WILL BE
ELECTRICALLY "HOT" TO WORK WHEN TIG
WELDING.
------------------------------------------------------------------------
Welders are shipped connected for the highest input
voltage as listed on the rating plate. To change this
connection, designations on the reconnect panel LOW,
MID, and HIGH correspond to the name plated input
voltages of a triple voltage welder. Dual voltage
welders use only LOW and HIGH.
EXAMPLE: On a 208/230/460 volt welder, LOW is
208V, MID is 230V, and HIGH is 460V.
Note: Export model has a voltage range for LOW and
MID connections: LOW is 220-230V, MID is
380-400V and High is 415V.
Reconnect the jumper strap to the terminal stud corre-
sponding to the input voltage level used. Make sure all
connections are tight.
Fuse the input circuit with the recommended super lag
fuses or delay type1 circuit breakers. Choose an input
and grounding wire size according to local or national
codes or use Section A-2. Using fuses or circuit break-
ers smaller than recommended may result in "nui-
sance" tripping from welder inrush currents even if not
welding at high currents.
Unbalanced AC TIG welding draws higher input cur-
rents than those for Stick, DC TIG, or Balanced AC TIG
welding. The welder is designed for these higher input
currents. However, where unbalanced AC TIG welding
above 275 amps is planned, the higher input currents
require larger input wire sizes and fuses per Section A-
2.
OUTPUT CABLES, CONNECTIONS AND
LIMITATIONS
To avoid being startled by a high frequency
shock, keep the TIG torch and cables in good
condition
Turn the power switch of the power source OFF
before installing adapters on cable or when con-
necting or disconnecting adapter plugs to power
source.
-----------------------------------------------------------------------
Refer to Figure A.2 for the location of the WORK and
STICK terminals, as well as the TIG Torch connection
panel.
WARNING
WARNING
A-6
INSTALLATION
PRECISION TIG 375
A-6
TIG TORCH CONNECTION
The Precision TIG torch connection box, located on the
right side of the machine, provides all the input and
output connections for the installation of both air-
cooled and water-cooled TIG torches with fittings con-
forming to Compressed Gas Association (CGA) stan-
dards:
Note: The Precision TIG provides an insulated Torch
Reel and Holster for handy and safe storage of con-
nected torch when not welding, and excess torch cable
length while welding.
Combination connectors (Power/Water and
Power/Gas) are electrically "hot" while welding in
STICK or TIG modes.
If using an Air-Cooled Torch be sure coolant is
shut off and/or Cooler is unplugged from the
Precision TIG Water Cooler Receptacle on the
torch side of the upper case back.
Observe the safety precautions necessary for han-
dling and using compressed gas containers.
Contact your supplier for specifics.
CYLINDER could explode
if damaged.
• Keep cylinder upright and
chained to a support.
• Keep cylinder away from areas
where it could be damaged.
• Never allow the torch to touch the cylinder.
• Keep cylinder away from live electrical cir-
cuits.
• Maximum inlet pressure 150 psi.
-----------------------------------------------------------------
The Precision TIG machines do not have Hi-Freq.
available at the Stick electrode stud, therefore stud
connection adapters (such as LECO. S19257-series)
cannot be used for torch connection.
Single-piece cable air-cooled torches with a 3/8-24 RH
connector fitting (such as the Magnum PTA-9/-17, or LA-
9/-17) require the provided S20403-4 Torch Connector,
while those with a 7/8-14 RH connector fitting (such as
the Magnum PTA-26, or LA-26) require the available
K2166-1 Torch Connector. (See Figure A.3)
Two-piece cable air-cooled torches (such as PTA-, or LA-
torches) can be used with the available K2166-2 1/2
Stud Connector with with a 7/8-14 LH male fitting.
Magnum PTW-18/-20 (or LW-) water-cooled Torches
require no adapter for Precision TIG connection.
WARNING
WORK
STICK
WORK
STICK
STICK
ELECTRODE
STUD
WORK
STUD
TIG TORCH
CONNECTIO
N
PANEL
FIGURE A
(Shown without hinged stud cover)
REMOTE
CONTROL
RECEPTACLE
CABLE
STRAIN
RELIEF HOLES
FIGURE A.2
A-7
INSTALLATION
PRECISION TIG 375
A-7
AUXILIARY POWER CONNECTIONS
The Precision TIG machines provide a standard NEMA
5-15R duplex receptacle, located on the upper case
back on the torch side of the machine:
The bottom outlet of this duplex receptacle provides
switched 115VAC power for the Under-Cooler, or
Water Solenoid accessory. This Cooler receptacle
turns on when the arc starts and remains on for about
8 minutes after the arc goes out (with the Fan-As-
Needed machine cooling fan, see Maintenance
Section), so the Coolers fan and water pump will not
run continuously in idle, but will run while welding.
The top outlet of this duplex receptacle provides at
least 8 amps at 115VAC, whenever the Precision TIG
Power switch is ON. This auxiliary circuit is intended
for running 115VAC accessories or small power tools.
Note: Some types of equipment, especially pumps
and large motors, have starting currents which are
significantly higher than their running current. These
higher starting currents may cause the circuit breaker
to open. (See next paragraph)
Both the receptacle circuits are protected from shorts
and overloads by a 15 amp circuit breaker, located
above the receptacle. if the breaker trips its button
pops out exposing a red ring. When the circuit break-
er cools the button can be reset by pressing it back
in.
Note: When the breaker trips not only will the auxil-
iary and cooler power be interrupted, but so will the
power to the shielding gas solenoid and machine
cooling fan.
The Precision TIG Export models also provide a
grounded 220vac Euro type Schuko receptacle and a
5 amp circuit breaker, located on the upper case back
on the reconnect side of the machine, intended for use
with a 220vac water cooler.
REMOTE CONTROL (If Used)
The Foot Amptrol (included with the Precision TIG
Welding Package), or other Remote accessory, is
installed by routing the plug of its control cable up
through the left cable strain relief hole provided in the
base (see Figure A.2), then connecting the 6-pin plug
to the mating Remote receptacle behind the stud panel
cover. (See Operation Section B-2 for mating plug
wiring.)
Note: If the Precision TIG is equipped with an Under-
Cooler or Under-Storage unit, the Foot Pedal (or other
remote control accessory) and coiled control cable, or
excess cable length, may be conveniently stored in the
drawer while remaining connected.
FIGURE A.3
For Gas Supply hose
with 5/8-18RH male
(Provided with Weld
Package model)
For Coolant Supply
Hoses
with 5/8-18LH male
(Provided with Weld
Package model
or
Under-Cooler Cart)
1/2-13
Stud
A-8
INSTALLATION
PRECISION TIG 375
A-8
ROBOTIC INTERFACE CONNECTION
Robotic interface can be made at the Remote
Receptacle (See Operation Section B-2). The machine
is shipped with the remote receptacle circuit internally
connected to receptacle J5 of the Control board for
standard Amptrol operation. In order to enable the
remote receptacle for robotic interface its connection
plug must be moved from J5 to J5A on the Control
board. (Refer to the machine Wiring Diagram.)
The robotic interface functions with the Precision TIG
set to either TIG or STICK mode, but must be in
REMOTE switch position for the Preset Control inter-
face to function. When in the REMOTE position with
robotic interface neither the MAXIMUM OUTPUT nor
the MINIMUM OUTPUT panel controls limit the inter-
face control setting over the rated output range of the
machine.
The diagram in Figure A.4 below shows the remote
receptacle plug connections and signals for robotic
interface:
+V
CC
= 70Vdc max.
R = V
CC
/ 5ma
5ma
Robotic
Common
A
B
C
D
E
F
REMOTE RECEPTACLE
(Front View)
For 18-12P Plug
(LECO S12020-27)
ARC START
INPUT FROM ROBOT
(18Vac,10ma switch)
*
+
PRESET CONTROL
INPUT FROM ROBOT
(0 -10Vdc = Rated Output Range)
ARC ESTABLISHED
OUTPUT TO ROBOT
(High = Not Welding)
(Low = Welding)
* Precision TIG Control Common.
Note: The Interface connection
cable may pick up noise
interference. Additional
bypass/filtering circuits may be
needed for the external circuits.
FIGURE A.4
B-1
OPERATION
B-1
PRODUCT DESCRIPTION
The Precision TIG 375 is part of a new family of indus-
trial arc welding power sources providing constant cur-
rent, single range square wave AC/DC TIG (GTAW)
with new patented (pending) Micro-Start
TM
Technology,
Presettable Min. and Max. Output controls, and built-in
high frequency stabilization for continuous AC TIG and
DC TIG starting. It also has AC/DC Stick (SMAW)
capability, with adjustable Arc Force availability. A TIG
Pulse Panel, Power Factor Capacitors and a Water
Solenoid are available as field installed optional kits.
Also, a new Undercarriage (with double gas bottle
rack) is available for field installation, as well as a new
Under-Cooler Cart, which is also included in an avail-
able efficiently integrated entire TIG Welding Package
with convenient built-in storage provisions for welding
equipment and components.
The Precision TIG 375 includes advanced features
such as a Digital Meter, Presettable control, Auto
Balance
TM
, Fan As Needed (F.A.N.) fixed Preflow, vari-
able Postflow shielding gas and Timers. In addition, 2-
Step/4-Step and Pulse TIG operation with adjustable
Downslope Time control are included with an available
field installed kit. It also features a Stick stud panel and
a universal TIG torch connection box for simultaneous,
but separated, electrode outputs.
PIPE THAWING
The Precision TIG 375 is not recommended for pipe
thawing.
Duty Cycle
The duty cycle is based upon a 10-minute time period;
i.e., for 40% duty cycle, it is 4 minutes welding and 6
minutes idling. If the rated duty cycle is significantly
exceeded, the thermostatic protection will shut off the
output until the machine cools to a normal operating
temperature. (Refer to Specification Section A-1)
PRECISION TIG 375
ELECTRIC SHOCK can kill.
Only qualified personnel should
perform this installation.
Turn the input power OFF at the
disconnect switch or fuse box.
Do not touch electrically live parts
or electrode with skin or wet cloth-
ing.
Insulate yourself from work and
ground.
Always wear dry insulating gloves.
Read and follow “Electric Shock
Warnings” in the Safety section if weld-
ing must be performed under electrical-
ly hazardous conditions such as weld-
ing in wet areas or on or in the work-
piece.
FUMES AND GASES
can be dangerous.
Keep your head out of fumes.
Use ventilation or exhaust to
remove fumes from breathing
zone.
WELDING SPARKS
can cause fire or
explosion
Keep flammable material away.
Do not weld on containers that
have held combustibles.
ARC RAYS
can burn.
Wear eye, ear and body
protection.
SAFETY PRECAUTIONS
Read and understand this entire section before operat-
ing the machine.
Observe additional Safety Guidelines detailed in
the beginning of this manual.
WARNING
B-2
OPERATION
B-2
RECOMMENDED PROCESSES AND
EQUIPMENT
RECOMMENDED PROCESSES
The Precision TIG 375 is recommended for the TIG
(GTAW) and Stick (SMAW) welding processes within
its output capacity range of 2 amps DC, or 5 amps AC,
to 420 amps AC/DC. It is compatible with most
Magnum TIG accessories (refer Equipment
Limitations), as well as many industry standard items,
such as TIG torches, hoses, and water coolers.
PROCESS LIMITATIONS
Precision TIG machines are not recommended for arc
gouging due to it's limited output capacity, and are also
not recommended for pipe thawing.
EQUIPMENT LIMITATIONS
The Precision TIG machines are protected from over-
loads beyond the electrical ratings and duty cycles, per
the Specifications Section A-1, A-2, with Thermostat
protection of the primary and secondary transformer
coils.
The Precision TIG machines do not have Hi-Freq.
available at the Stick electrode stud, therefore stud
connection adapters (such as LECO. S19257-series)
cannot be used for torch connection.
PRECISION TIG 375
RECOMMENDED EQUIPMENT/INTERFACE
TIG (water cooled) TIG (air cooled)
Machine: PT375 Welding Package (K1903-1) PT275(K1833-1, -2, K1834-1)
Input Cable/Clamp: User provided User provided
Gas Reg./Hose: (included) LE/Harris 3100211
Magnum Torch: (PTW20 included) PTA9 or PTA17
Magnum Parts: (KP510 and K918-2 included) KP507 or KP508
Work Clamp/Lead: (15 ft. included) K2150-1 Work Lead Assembly
Foot Amptrol: (K870 included) K870 or K870-1
B-3
OPERATION
B-3
1. POWER SWITCH - Input line switch turns input
power ON or OFF, as indicated by the on or off sta-
tus of the front panel displays.
2. POLARITY SWITCH The 3-position rotary power
switch has detente positions for DC-, AC and DC+
selections for the Electrode output welding polarity.
3. MODE SWITCH – The mode switch allows vertical-
ly positioned selection of the two machine welding
modes. The selected mode is indicated by a lit col-
ored panel light which permits viewing the machine
setting from a distance:
3.a STICK mode (Top position) Red panel light
ELECTRIC SHOCK can kill.
When the Power Source is ON in
STICK mode the Electrode circuits of
both the Stick and TIG torch cables
are electrically HOT to Work.
------------------------------------------------------------------------
The CC Stick mode may be used for general pur-
pose stick welding (SMAW ) within the capacity of
the machine. The capacity is too limited for arc air
carbon (AAC) gouging.
In this mode; the output terminals are activated
electrically HOT, gas flow is not activated and HOT
START and ARC FORCE levels are fixed, or
Advanced Panel selectable (See Section B-7 ), with
no front panel adjustment.
3.b TIG mode (Bottom position) No panel light.
When the Polarity Switch is set to AC, the TIG
mode provides continuous high frequency to stabi-
lize the arc for AC TIG welding.
Hi-Freq. turns on after preflow time with the arc
start switch closure, and turns off when the arc
goes out* after the arc start switch opens.
* Arc voltage and current are sensed to determine if
the arc is established or out.
PRECISION TIG 375
CONTROLS AND SETTINGS
The Front Control Panel contains the knobs and switches necessary for adjusting the operation of the Precision
TIG 375, with function indicator lights and an electronic display for volts and amps. The components are
described below:
FIGURE B.1 - CONTROL PANEL
WARNING
1. POWER SWITCH
2. POLARITY SWITCH
3. MODE SWITCH
4. AC BALANCE CONTROL
5. LOCAL/REMOTE
CURRENT CONTROL
SWITCH
6. MAXIMUM OUTPUT CONTROL
7. MINIMUM OUTPUT CONTROL AND
DISPLAY SWITCH
8.
DIGITAL METER AND DISPLAY
SWITCH
9. POSTFLOW TIME
10. THERMAL SHUTDOWN LIGHT
11. REMOTE RECEPTACLE
12. TRIGGER SWITCH
13. PULSE MODE SWITCH
14. PULSE FREQUENCY CONTROL
15. PULSE % ON TIME CONTROL
16. PULSE BACKGROUND CURRENT
CONTROL
17. DOWNSLOPE TIME
18. HIGH FREQUENCY INTENSITY
CONTROL (NOT SHOWN LOCATION
ONLY)
18
B-4
OPERATION
B-4
When the Polarity Switch is set to DC (- or +), the
TIG mode provides high frequency only for starting.
Hi-Freq. turns on after pre-flow time with the arc
start switch closure, and turns off when the arc is
established*
Also functions for DC+ polarity to permit "balling" of
tungsten for AC TIG welding.
4. AC BALANCE CONTROL The potentiometer
control permits AC wave balance adjustment from
Max. Penetration (~85% negative wave) with the
control at Max. full CW position, to Max. Cleaning
(~65% positive wave) with the control set near min-
imum CCW position.
Full minimum CCW position is the Auto Balance
position which is indicated by the Green panel light
turning on. This feature automatically provides the
proper amount of cleaning and penetration for nor-
mal AC TIG welding
The mid position is the Balanced position (~50%
positive and negative waves).
The Balance control is only functional if the machine
is set to AC polarity and TIG mode.
5. LOCAL/REMOTE
CURRENT CONTROL SWITCH
A
2-position switch selects how the welding output is
controlled for both Stick and TIG Modes:
LOCAL (Top position) selects output control only by
the machine panel Output Control. (See Item 6)
REMOTE (Bottom position) selects output control to
also be by an Amptrol (See Item 6), or other remote
(10K pot) control connected to the Remote recepta-
cle (See Item 11) This switch selection is indicted by
the Green panel light turning on.
In either position the arc start switch functions when
connected to the Remote receptacle (See Item 11).
6. MAXIMUM OUTPUT CONTROL The large knob
is used to set the output welding current over the
rated output range of the machine.
With the Current Control switch to LOCAL position,
this knob sets the welding output level.
* Arc voltage and current are sensed to determine if
the arc is established or out.
With the Current Control switch to REMOTE posi-
tion, this knob sets the maximum welding level that
the Peak output can be set with the remote Amptrol.
The new MicroStart
TM
Technology minimum current
circuit provides for low end welding (down to 2
amps) previously unobtainable on an SCR platform
TIG machine.
7. MINIMUM OUTPUT CONTROL AND DISPLAY SWITCH
A smaller knob is used to preset the minimum cur-
rent level only for TIG mode. Pressing the Display
(momentary) switch toggle left to Minimum Set posi-
tion displays the Minimum control level setting on the
Digital meter. (See Item 8)
This knob sets the Start output level. When the arc
lights (using a new built-in TIG start pulse) this level
upslopes quickly (0.5 sec.) and smoothly to the weld
output level. The setting range for this Start control
is the 2 amp minimum range of the machine up to
about 50 amps, but no more than the level set by
the Maximum Output control knob (See Item 6), but
otherwise is independent of the Maximum setting.
This setting also serves as the Crater-fill level, it can
also be selected (see Section B-7) to be either the
Minimum Output control setting (same as Start set-
ting) as shipped, or the minimum rating of the
machine (2 amps).
The Remote Amptrol range of control is between
this Minimum setting and the Maximum Output con-
trol knob setting, so these knobs can set the resolu-
tion of the Amptrol. Also, the Minimum setting
serves as both the minimum Amptrol start level
when the arc start switch is closed, as well as the
minimum Amptrol crater-fill level before the arc start
switch is opened to help prevent premature arc out
and Hi-Freq re-initiation.
In STICK mode the Start control is not functional
since Hot Start level is fixed, or internal Advanced
Panel adjustable (see Section B-7). Pressing the
Display (momentary) switch toggle left to Minimum
Output position displays minimum amps rating of
the machine.
PRECISION TIG 375
B-5
OPERATION
B-5
8. DIGITAL METER AND DISPLAY SWITCH A3-
digit LED meter is used to monitor the preset and
actual welding procedure based on the Display
(momentary) switch position:
Before welding with Display switch in center (nor-
mal) position, the digital meter displays the preset
welding amps set by Maximum Output control knob
(See Item 6). If in Stick mode using REMOTE (See
Item 5.), the digital meter displays the preset weld-
ing amps set by the Remote control. (See Item 11)
While welding with Display switch in center (normal)
position, the digital meter displays the actual weld-
ing amps with one amp resolution (XXX) and accu-
racy within 4%+/-2A of reading.
Any time in TIG mode and while pressing the
Display switch to left, the digital meter displays the
amps preset by the Minimum Output control knob
(See Item 7).
Any time in Stick mode and while pressing the
Display switch to left, the digital meter displays the
minimum amps rating of the machine (See Item 7).
Any time, in either mode, while pressing the Display
switch right to Volts position, the digital meter dis-
plays actual output volts. Volts is displayed with 0.1
volt resolution (XX.X) and accuracy within 3%+/-1V
of reading.
9. POSTFLOW TIME This knob is used to set the
TIG mode shielding gas postflow time over the
range of about 2 to 60 seconds after the arc is shut
off. The postflow on time status is indicated by the
Green panel light.
Gas preflow time for TIG mode is fixed at 0.5 sec-
ond, with no panel control.
Both time ranges are x2 extendable, if needed, by
internal control box selection. (See Section B-7)
10. THERMAL SHUTDOWN LIGHT This yellow LED
panel light turns on if the machine output is shut-
down because internal overheating has occurred,
and turns off when the thermostat resets.
11. REMOTE RECEPTACLE A 6-socket receptacle
is provided for the connection of an Amptrol, or
other, remote control: (See Figure B.2)
When the Current Control Switch, (See Item 5), is
in the REMOTE position the Amptrol, or other
remote (10K pot), connected to the Remote recep-
tacle controls the TIG or Stick mode output within
the range preset by the Maximum and Minimum
Output controls. (See Item 6 and Item 7, also 8 for
meter display)
When the Current Control Switch is in either LOCAL
or REMOTE positions the arc start switch functions
when connected to the Remote receptacle.
ADVANCED PANEL CONTROLS
The following Advanced Control Panel controls are
standard on the Precision TIG 375 : (Refer to Section
B-10 Tig Weld Cycle Chart for graphic illustration of
these TIG welding functions.)
12. TRIGGER SWITCH This 2-position switch
selects how the arc start switch ( connected to the
above Remote receptacle) functions; in 2-Step or
4-Step mode:
DO NOT USE 4-STEP IF USING AN AMPTROL
REMOTE.
Neither the arc start switch nor the output con-
trol in the amptrol will function normally to shut
off or control the out put. ONLY USE 2-STEP.
------------------------------------------------------------------------
In 2-Step position the arc start switch functions the
same as without the Advanced Panel:
1. Closing switch starts preflow, then a fixed
(0.5 sec.) ramp time from Minimum (Start)
setting level (See Item 7) to Weld setting.
2. Opening switch initiates Downslope ramp
time setting (See Item 17), from Weld set-
ting to Crater-fill level (See Item 7), which
then stops the arc and initiates Postflow
time (See Item 9).
Note: See Section B-7 for 2-Step operation during
Downslope with Restart feature selected to be dis-
abled, instead of enabled (as shipped).
PRECISION TIG 375
A
B
C
D
E
F
Max
10K ohm
Min
REMOTE RECEPTACLE*
(Front View)
REMOTE OUTPUT
CONTROL
ARC START
SWITCH
*For 18-12P Plug
(LECO S12020-27)
CAUTION
FIGURE B.2
B-6
OPERATION
B-6
In 4-Step position allows welding without continu-
ously holding the start switch trigger. The arc start
switch functions in the following manner:
1. Closing switch starts preflow, then arc starts
at Minimum (Start) setting level (See Item
7). If the trigger is maintained closed after
preflow time the output remains at the Start
level until it is released.
2. Opening switch initiates fixed (0.5 sec.)
ramp time from Start setting level to Weld
setting.
3. Reclosing switch initiates Downslope ramp
time setting (See item 17) from Weld setting
down to the Crater-fill level (See Item 7) of
the machine.
4. Reopening switch after Downslope time
holds Crater-fill level until switch opens,
then stops the arc and initiates the Postflow
Time (See Item 9). Or, reopening switch
during Downslope time immediately stops
the arc and initiates the Postflow.
Note: See Section B-7 for 4-Step operation during
Downslope with Restart feature selected to be
enabled, instead of disabled (as shipped).
13. PULSE MODE SWITCH Turns on the Pulse
Mode as indicated by the Green panel light turning
on.
Pulsing provides a Peak current level set by
REMOTE and/or LOCAL control of the output cur-
rent (See Item5), for a time determined by the Pulse
Frequency Control setting (See Item 14) and the %
ON Time (See Item 15). The balance of the cycle
time is at the Background Current level (See Item
16).
Pulsing begins after upslope when the output cur-
rent rises above the Background Current level and
ends when the output current drops below this level.
14. PULSE FREQUENCY CONTROL This knob is
used to set the Pulse Frequency over the peak
pulse range of about 0.1 pps to 20 pps. (One pulse
cycle time = 1/pps = 10 to .05 sec. range.)
15. PULSE % ON TIME CONTROL This knob con-
trols the duration of the peak current as a percent-
age (5% to 95%) of one pulse cycle. The balance
of the cycle time will be at the Background Current
setting. (See Item 16)
16. PULSE BACKGROUND CURRENT CONTROL
This knob controls the level of the Background
Current as a percentage (MIN.-100%) of the Peak
(REMOTE and/or LOCAL) output level (See Item
6) down to the Minimum Output setting (See Item
7).
17. DOWNSLOPE TIME This knob is used to set the
time, over the range of zero to about 10 seconds,
to ramp down from weld setting to Crater-fill level
(See Item 7).
If the arc goes out after the Downslope time is initi-
ated, the Downslope time is interrupted and the
Postflow time is initiated. This prevents Hi-Freq re-
initiation during ramp down crater fill
When using an Amptrol remote control, where the
downslope is controlled by the operator down to the
crater-fill level, the Downslope time should be set to
zero so as not to have the Downslope time delay
when the arc start switch is opened.
18.HIGH FREQUENCY INTENSITY CONTROL (NOT
SHOWN) Allows setting the lowest intensity which
still gives good TIG arc starting with minimized
Radio Frequency Interference (RFI). Control knob
is located on a recessed panel near the easy acces-
sible spark gap side panel. As shipped, the control
is set to minimum.
PRECISION TIG 375
/