Chief CMA115W User manual

Category
Wall & ceiling mounts accessories
Type
User manual

This manual is also suitable for

INSTALLATION INSTRUCTIONS
CMA105
CMA110
CMA115
Ceiling Plates
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
CMA105-110-115
CMA105-110-115 Installation Instructions
2
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
IMPORTANT SAFETY INSTRUCTIONS!
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installers responsibility to make sure all components are
properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installers responsibility to make sure the combined weight of
all components attached to the CMA mount does not exceed
500 lbs (226.8 kg).
NOTE: The weight capacity of the CMA mounts may be
LIMITED to the lowest weight capacity of any other
component located between the ceiling plate and the
projector/display.
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Do not use this product outdoors.
NOTE: CMA105, CMA110, CMA115 are intended to be used
with a 1-1/2" NPT or NPSM following ANSI/ASME
B1.20.1 (Schedule 40, 0.154" minimum thickness
aluminum - ASTM B221) threaded extension column
(not included).
IMPORTANT ! : These CMA mounts are designed to be:
mounted to a 2" x 6" wood framework ceiling
covered with 5/8" drywall;
mounted to an 8" concrete ceiling using either
1/4" x 2-1/2" lag bolts for Toggler AF8 anchors
(not included), or 5/16" x 2-1/2" lag bolts for
Fischer UX10 concrete anchors (not included);
suspended from four 3/8" diameter (minimum)
Grade 2 or better threaded rods with 16 threads
per inch (not included) which are secured to a
framing channel (spanning a maximum of 5 feet
--not included) by Grade 2 or better 3/8" channel
nuts (not included).
NOTE:
These CMA mounts provide vertical adjustments in 3/4"
increments.
NOTE: CMA105, CMA110 and CMA115 may be used with UL
Listed CMA151 1-1/2" to 1" NPT Adapter Accessory.
WARNING: Do NOT attach to vertical mounting surfaces
such as walls or angled ceilings!
--SAVE THESE INSTRUCTIONS--
Installation Instructions CMA105-110-115
3
DIMENSIONS
.68
17.254
1.50
38.100
3.00
76.200
4.00
101.600
4.00
101.600
1.35
34.163
2.690
68.326
4X .44 X .75 SLOT
[11.2 X 19.0]
1 1/2 NPT
DIMENSIONS: INCHES
[MILLIMETERS]
CMA105
.68
17.254
3.25
82.550
6.50
165.100
8.00
203.200
8.00
203.200
.75
19.050
3.09
78.457
6.19
157.226
.91
22.987
4X .44 X .75 SLOT
[11.2 X 19.0]
1 1/2 NPT
DIMENSIONS: INCHES
[MILLIMETERS]
CMA110
CMA105-110-115 Installation Instructions
4
DIMENSIONS (continued)
TOOLS REQUIRED FOR INSTALLATION
PARTS
.68
17.254
4.50
114.300
2.25
57.150
6.00
152.400
6.00
152.400
.75
19.050
2.10
53.213
4.19
106.426
.91
22.987
1 1/2 NPT
4X .44 X .75 SLOT
[11.2 X 19.0]
DIMENSIONS: INCHES
[MILLIMETERS]
CMA115
5/32" (security) (included)
3/32" (included)
A (1)
[ceiling plate - CMA105 shown]
B (1)
#10-24 x 1/4" C (1)
#10-24 x 1/4"
D (1)
[security spinner] F (1)
3/32"
(security)
E (1)
5/32"
Installation Instructions CMA105-110-115
5
LEGEND
Tighten Fastener
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Phillips Screwdriver
Destornillador Phillips
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Open-Ended Wrench
Llave de boca
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Clé à fourche
By Hand
A mano
Von Hand
Com a mão
A mano
Met de hand
À la main
Hex-Head Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Zeskantsleutel
Clé à tête hexagonale
Pencil Mark
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Drill Hole
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Percez un trou
Adjust
Ajustar
Einstellen
Ajustar
Regolare
Afstellen
Ajuster
Remove
Quitar
Entfernen
Remover
Rimuovere
Verwijderen
Retirez
Optional
Opcional
Optional
Opcional
Opzionale
Optie
En option
Security Wrench
Llave de seguridad
Sicherheitsschlüssel
Chave de segurança
Chiave di sicurezza
Veiligheidssleutel
Clé de sécuri
CMA105-110-115 Installation Instructions
6
INSTALLATION AND ASSEMBLY
WARNING: Do NOT attach to vertical mounting surfaces
such as walls or angled ceilings!
WARNING: IMPROPER INSTALLATION CAN LEAD TO
LIFT FALLING CAUSING SEVERE PERSONAL INJURY OR
DAMAGE TO EQUIPMENT! It is the installer’s responsibility
to make certain the structure to which the mount is being
attached is capable of supporting five times the weight of the
CMA mount and all attached equipment. Reinforce the
structure as required before installing the mount.
NOTE: The following instructions assume a suitable mounting
structure and surface exists prior to installation.
Installing to a Wood Framework (Joists)
NOTE: These CMA mounts are designed to be mounted to a
2" x 6" wood framework ceiling covered with 5/8"
drywall.
1. Use 5/16-18" x 2-1/2" (minimum) Grade 2 lag screws (not
included) to secure CMA mount to the joists or wood
framework, using the bolt holes noted. (See Figure 1)
NOTE: If using only two bolt holes for mounting, two opposing
holes must be used.
Installing to a Suspended Ceiling
NOTE: These CMA mounts may be suspended from four 3/8"
diameter (minimum) Grade 2 or better threaded rods
with 16 threads per inch (not included) which are
secured to a framing channel (spanning a maximum of
5 feet--not included) by Grade 2 or better 3/8" channel
nuts (not included).
1. Insert the rods into the four bolt holes in the CMA mount.
(See Figure 1)
2. Secure the threaded rods to the CMA mount with Grade 2
or better 3/8" jam nuts (not included) and washers (one of
each on inside and one of each on outside--not provided).
Installing to a Solid Concrete Ceiling Structure
NOTE: These CMA mounts may be mounted to an 8" concrete
ceiling using either 1/4" x 2-1/2" lag bolts for Toggler
AF8 anchors (not included), or 5/16" x 2-1/2" lag bolts
for Fischer UX10 concrete anchors (not included)
WARNING: Anchors (not included) must be installed into
structurally sound solid concrete. Installation into hollow
concrete block, mortar, or concrete that exhibits cracking,
spalling, or other defects may result in failure of anchor and
serious personal injury or damage to equipment.
1. Use
either 1/4" x 2-1/2" lag bolts for Toggler AF8 anchors
(not included), or 5/16" x 2-1/2" lag bolts for Fischer UX10
concrete anchors (not included)
to secure CMA mount into
solid concrete ceiling. (See Figure 1)
2. Place CMA mount over anchors, placing bolt holes in CMA
mount over anchors.
3. Secure CMA mount to ceiling using four Grade 2 flat
washers (not included) and four Grade 2 nuts (not included)
tightened over anchors.
Figure 1
1.50
[38.100]
3.00
4.00
[101.600]
4.00
[101.600]
1.35
[34.163]
2.690
[68.326]
4X .44 X .75 SLOT
[11.2 X 19.0]
1 1/2 NPT
[114.300]
2.25
[57.150]
6.00
[152.400]
6.00
[152.400]
.75
[19.050]
2.10
[53.213]
4.19
[106.426]
.91
[22.987]
1 1/2 NPT
4X .44 X .75 SLOT
[11.2 X 19.0]
3.25
[82.550]
6.50
[165.100]
8.00
203.200
8.00
[203.200]
.75
[19.050]
3.09
[78.457]
6.19
[157.226]
.91
[22.987]
4X .44 X .75 SLOT
[11.2 X 19.0]
1 1/2 NPT
CMA105
CMA110
CMA115
Installation Instructions CMA105-110-115
7
Attaching Column to CMA Mount (non-security)
1. Install 1-1/2" NPT or NPSM following ANSI/ASME B1.20.1
(Schedule 40, 0.154" minimum thickness steel or aluminum
- ASTM B221) threaded extension column (not included)
into threaded collar until tight, with a minimum of four
threads engaged. (See Figure 2)
2. Install #10-24 1/4" set screw (B) into hole on ceiling plate (A)
to secure pipe to mount. (See Figure 2)
Figure 2
3. Install the ceiling mount and projector to the CMA mount
using installation instructions included with the ceiling
mount.
Attaching Column to CMA Mount (security)
1. Install 1-1/2" NPT or NPSM following ANSI/ASME B1.20.1
(Schedule 40, 0.154" minimum thickness steel or aluminum
- ASTM B221) threaded extension column (not included)
into threaded collar until tight, with a minimum of four
threads engaged. (See Figure 3)
2. Install #10-24 1/4" button head security screw (C) through
security spinner (D) and into hole on ceiling plate (A) to
secure pipe to mount. (See Figure 3)
Figure 3
3. Install the ceiling mount and projector to the CMA mount
using installation instructions included with the ceiling
mount.
(B)
1 1/2 NPT threaded
2
1
(A)
column (not included)
(D)
(C)
2
1
(A)
1 1/2 NPT threaded
column (not included)
CMA105-110-115 Installation Instructions
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P800.582.6480 / 952.225.6000
F877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P+31 (0) 495 580 852
F+31 (0) 495 580 845
Asia Pacific A Office No. 1 on 12/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P852 2145 4099
F852 2145 4477
Chief, a products division of
Milestone AV Technologies
8800-002561 Rev00
2014 Milestone AV Technologies
www.chiefmfg.com
04/14
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Chief CMA115W User manual

Category
Wall & ceiling mounts accessories
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages