TOA TS-918 Expansion Unit, TS-918 CE/CE-AU/CE-GB/CN/KR/US User manual

  • Hello! I am an AI chatbot trained to assist you with the TOA TS-918 Expansion Unit User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
TS-918EXPANSION UNIT
INSTRUCTION MANUAL
Thank you for purchasing TOA’s Expansion Unit.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
1. SAFETY PRECAUTIONS
•Before installation or use, be sure to carefully read all the instructions in this section for
correctandsafeoperation.
•Besuretofollowalltheprecautionaryinstructionsinthissection,whichcontainimportant
warningsand/orcautionsregardingsafety.
•Afterreading,keepthismanualhandyforfuturereference.
Indicatesapotentiallyhazardoussituationwhich,ifmishandled,
couldresultindeathorseriouspersonalinjury.
WARNING
Indicatesapotentiallyhazardoussituationwhich,ifmishandled,could
resultinmoderateorminorpersonalinjury,and/orpropertydamage.
CAUTION
WARNING
When Installing the Unit
•Do not expose the unit to rain or an
environmentwhereit maybe splashedby
water or other liquids, as doing so may
resultinreorelectricshock.
•Usetheunitonlywiththevoltagespecied
on the unit. Using a voltage higher than
thatwhichisspeciedmayresultinreor
electric shock.
•Do not cut, kink, otherwise damage nor
modifythepowersupplycord.Inaddition,
avoid using the power cord in close
proximitytoheaters,andneverplaceheavy
objects--includingtheunititself--onthe
powercord,asdoingsomayresultinreor
electric shock.
•Avoid installing or mounting the unit in
unstable locations, such as on a rickety
table or a slanted surface. Doing so may
resultin the unitfalling downandcausing
personalinjuryand/orpropertydamage.
When the Unit is in Use
•Should the following irregularity be found
during use, immediately disconnect the
powersupply plugfromtheACoutletand
contactyournearestTOAdealer.Makeno
further attempt to operate the unit in this
conditionasthismaycausereorelectric
shock.
·If you detect smoke or a strange smell
coming from the unit.
·Ifwateroranymetallicobjectgetsintothe
unit
· If the unit falls, or the unit case breaks
·If the power supply cord is damaged
(exposureofthecore,disconnection,etc.)
·Ifitismalfunctioning(notonesounds.)
•To prevent a re or electric shock, never
open nor remove the unit case as there
are high voltage components inside the
unit.Referallservicingtoqualiedservice
personnel.
•Do not place cups, bowls, or other
containers of liquid or metallic objects on
topoftheunit.Iftheyaccidentallyspillinto
the unit, this may cause a re or electric
shock.
•Do not touch a power supply plug during
thunderandlightning,asthismayresultin
electric shock.
When Installing the Unit
•Be sure to follow the instructions below
whenrack-mountingtheunit.Failuretodo
somaycauseareorpersonalinjury.
· Install the equipment rack on a stable,
hardoor.Fixitwithanchorboltsortake
other arrangements to prevent it from
fallingdown.
·When connecting the unit’s power cord
to an AC outlet, use the AC outlet with
current capacity allowable to the unit.
·The supplied rack-mounting screws can
beusedfortheTOAequipmentrackonly.
Donotusethemforotherracks.
•Neverpluginnorremovethepowersupply
plugwithwethands,asdoingsomaycause
electric shock.
•When unplugging the power supply cord,
be sure to grasp the power supply plug;
neverpullonthecorditself.Operatingthe
unit with a damaged power supply cord
maycauseareorelectricshock.
•When moving the unit, be sure to remove
its power supply cord from the wall outlet.
Moving the unit with the power cord
connectedtotheoutletmaycausedamage
tothepowercord,resultinginreorelectric
shock.Whenremovingthepowercord,be
suretoholditsplugtopull.
•Avoid installing the unit in humid or dusty
locations,inlocationsexposedtothedirect
sunlight, near the heaters, or in locations
generatingsootysmokeorsteamasdoing
otherwise may result in re or electric
shock.
When the Unit is in Use
•Donotplaceheavyobjectsontheunitas
this may cause it to fall or break which may
result in personal injury and/or property
damage. In addition, the object itself may
falloffandcauseinjuryand/ordamage.
•If dust accumulates on the power supply
plug or in the wall AC outlet, a re may
result. Clean it periodically. In addition,
insertthepluginthewalloutletsecdurely.
•UnplugthepowersupplyplugfromtheAC
outlet for safety purposes when cleaning
or leaving the unit unused for 10 days or
more.Doingotherwisemaycauseareor
electric shock.
•Use the supplied AC adapter for the unit.
Note that the use of other adapter may
causeare.
CAUTION
2. GENERAL DESCRIPTION
TheTS-918isaninterfaceforincorporatingtheWiredConferenceunit(s)intheconferencesystem.
ItisconnectedtotheTS-910CentralunitwithacoaxialcableandtotheTS-919B1or919B4Bridge
unitwithaCat-5LANcable.
The TS-918 (1U size) can be mounted on an EIA equipment rack by using the optional rack-
mounting bracket.
3. FEATURES
•Connection between the TS-918 and the Bridge unit can be made using a single CAT-5 LAN
cable,facilitatinginstallationandconstructionwork.
•Upto24ConferenceunitsperTS-918ExpansionunitcanbeconnectedviatheBridgeunits.
•Upto8TS-918ExpansionunitscanbeconnectedtotheCentralunitbyusingtheYW-1022or
YW-1024Distributors.
4. SPECIFICATIONS
PowerSource 100–240VAC,50/60Hz(useofthesuppliedACadapter)
Power Consumption 74.4W
Current Consumption Max. 3.1ADC (when24VDC issuppliedfromthesuppliedAC
adapter)
Gain Upstream: +16.5dB
Downstream:+12.5dB
Connection Terminal Centralunitconnectionterminal: BNCjack
Bridgeunitconnectionterminal: RJ45connector
LEDIndicator Connectionstatusindicators(3LEDseachonthefrontandrear
panels),Powerindicator
NumberofConnectable
Chairman/DelegateUnits
Upto24units(whenusing21unitsofTS-919B1or6unitsofTS-
919B4,bothoptionalBridgeunits)
Operating Temperature 0to40ºC(32to104ºF)
OperatingHumidity 90%RHorless(nocondensation)
Finish Panel:Aluminum,black,30%gloss,melamine-bakedpaint
Case:Pre-coatedsteelplate,black
Dimensions 210(w)x44(h)x296.5(d)mm(8.27"x1.73"x11.67")
Weight 1.6kg(3.53lb)
Note: Thedesignandspecicationsaresubjecttochangewithoutnoticeforimprovement.
Accessories
ACadapter*(DCcord:1.8mor5.91ft,DetachableACcord:2mor6.56ft) ..............................1
BNCplug-toBNCplugcord(50cmor1.64ft) ..............................................................................1
* NotsuppliedwiththeTS-918(KR).FortheusablepowersupplycordandACadapter,consult
yournearestTOAdealer.
• Optional products
Rackmountingbracket:MB-15B-BK(forrackmountingoneTS-918unit)
MB-15B-J(forrackmountingtwoTS-918units)
Traceability Information for Europe
Manufacturer:
TOA Corporation
7-2-1,Minatojima-Nakamachi,Chuo-ku,Kobe,Hyogo,
Japan
Authorizedrepresentative:
TOAElectronicsEuropeGmbH
Suederstrasse282,20537Hamburg,
Germany
URL:http://www.toa.jp/
133-02-00129-01
/