  • What is the maximum input BTU per hour for the AccuTemp N6 Natural Gas and Propane models?
    What is the minimum gas supply pressure required for the Natural Gas and Propane models?
    What type of electrical connection does the AccuTemp N6 require?
    Does the AccuTemp N6 require water filtration or treatment?
    What is the warranty for the AccuTemp N6?
Standard Features
• Fastcooktimeswithpatent-pending
SteamVectorTechnology,whichutilizes
nomovingparts
• CookmodeandVariableTemperature
Holdmode
• SteamerpoweredbyaHeavyDuty
StainlessSteelBlueFlamePowerBurner
ratedat60,000btu/hr
• Easy-to-usedigitalcontrols,withdigital
temperaturedisplay
• Independentdigitalelectronictimerwith
programmablepreset
• Simplewateranddrainconnections
• Nowaterfiltrationortreatmentrequired
• Nowarrantyexclusionsforwaterquality
• Useslessthan1gallonofwaterperhour
• Front-mounteddrainvalve
• FlushMounttocounter
• SpecifyAltitudeifover2,000ftabovesea
level
• Internalgasregulator
• Noscheduledde-limingormaintenance
• Heavy-duty,field-reversibledoor
• Doorcanbeopenedatanytimeduring
cookingcycle
• Steamercavityconstructedofreinforced
14ga.304stainlesssteel
• Easy-to-cleancontrolpanel
• Automaticaltitudecompensation
• Dishwasher-safeone-piecewirepan
racks
• Dishwasher-safeSVTsteamcollectorand
distributorpanels
• Front-mountedcondensatetray
• EnglishandSpanishoperating
instructionsondoor
• Simplifiedserviceaccesspanel
• Lowwater,highwaterandovertemp
indicatorlights
• 5’powercordwithplugincluded
• Oneyearpartsandlaborwarranty
• LifetimeService&SupportGuarantee
• ULLISTEDSafetyCertification
(ANSIZ83.11)
• ULEPHSanitationCertification
(NSF4)
Optional Features
• BulletFeet
• Stainlesssteelsupportstandavailable
withcasters,bulletfeetorflangedfeet
• Perforatedcookingshelf
• FlangedFeet
• Propane
Environmental Approvals &
Programs
Other Approvals
Pan Capacities
PanSize Qty.
#200fullsize(12x20x2.5”) 6
#400fullsize(12x20x4”) 4
Short Spec
EvolutionsteamerisAccuTempProducts’
connected,boilerlesssteamcookerthat
utilizesAccuTemp’sPatentPending
SteamVectorTechnologyforfastercook
times,improvedenergyefficiency,better
pantopanuniformity,andlesswater
consumption.SteamVectorTechnology
requiresnomovingpartsinsidethe
cookingchamber.Steamtobeproduced
insidethecookingcavitywithnoheating
componentsexposedtowater.Unittobe
poweredbyaHeavyDutyStainlessSteel
BlueFlamePowerburner,Easilyconnects
towater,drain&gaslines.Useslessthan
1gallonofwaterperhour.Unitto
includelowwater,highwater,overtemp
warninglightsandautoshutofffeature.
Evolutiontoincludeheavyduty,field
reversibledoor.Standarddigitalcontrols
withindependenttimer.Nowaterquality
exclusionstowarrantyandnowater
filtrationortreatmentrequired.Unitto
beULSafetyandSanitationCertified,and
EnergyStarqualified.BuiltinUSA.
N6 Fl u s h Mo u N t Co N N e C t e d ev o l u t i o N
6Pan,NaturalGasBoilerlessConvection
FlushMountSteamer
MM4225-1004
Project:___________________________________Location:___________________________________Item#:___________________________________Quantity:___________
AccuTemp Products, Inc.
8415 North Clinton Park Fort Wayne, IN 46825 800-210-5907 260-493-0415 • Fax 260-493-0318 accutemp.net
ANSI 4
N6 Evolution Flush Mount
Model Shown
Gas Steamer Model Specifications
Model #
N61201EF P61201EF
Gas Supply
Natural Gas Propane
Recommended
Gas Feed Rate
5” wc min
14” wc max
12” wc min
14” wc max
Gas operating
Pressure
5.0” wc 10.0” wc
Maximum input
BTU’s/hr
60,000 60,000
Electrical Pow-
ered
120v, Single Phase, 60hz,
1 AMP
NEMA Plug
5-15 three prong plug
Notes:
1.Allow3”betweenfryer,ranges,andotherhotsurfaces.
2.5’powercordwithNEMA5-15threeprongplug,120v,
singlephase,60hz,1AMP.
3.1/2”NPTThreadedNaturalGasConnection.
4.Dimensionsoutsidebracketsareinches,inbracketsaremillimeters.
5.Eachunitequippedwith3/4”malegardenhoseconnector
6.Eachunitequippedwith3/4”barbeddrainlineconnector
7.DONOTplumbasingledrainlinebetweenthe2units.Each
unitmusthaveaseparateopengaptypedrainline.
8.Thisappliancenotintentedforhouseholduse.
9.UnitsequippedwithinternalGasRegulator.
MM4225-1004
AccuTemp Products, Inc.
8415 North Clinton Park Fort Wayne, IN 46825 800-210-5907 260-493-0415 • Fax 260-493-0318 accutemp.net
N6 Fl u s h Mo u N t Co N N e C t e d ev o l u t i o N
6Pan,NaturalGasBoilerlessConvection
FlushMountSteamer
15.43
391.8
43.33
1100.
7
1.49
37.8
1.32
33.4
23.26
590.9
28.61
726.7
REAR SIDE UNIT
COUNTERTOP
MOUNTING HOLES
LOCATION
15.00
381
7.75
MIN
196.9
19.13
485.9
4X
.44
11.1
28.00
MIN
711.2
23.63
600.2
2.7
70.9
2.47
62.7
3/4 IN.
MGH WATER
CONNECTION
AC POWER
3/4 IN. BARB
FOR OPEN-GAP DRAIN
1/2 NPT GAS
CONNECTION
4.97
126.2
1.99
50.6
7.09
180.1
9.76
247.8
/