  • Hello! I am an AI chatbot trained to assist you with the Paxton Net2 Modem Adaptor User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
0V 12V
Net2 Modem Adaptor
Orange
White/orange
Green
White/green
Do not connect
0V
Wiring
12V DC
power supply
230V AC
input
12V output. Total load
including converter
should not exceed 1A
IMPORTANT: THIS IS
NOT AN INPUT
ALL OTHER SPARE
CORES
The converter can be installed at either end of the data line or anywhere along the data line.
120 ohm terminating resistors must be linked across each data pair at the beginning AND end of the line.
This can be done on many units with a switch or jumpers. If not, free resistors are provided with the
converter. If the data line extends past 1 km an RS485 repeater (447-836/477-844) is required.
Termination
1 km max
Resistor x 2
Ins-30073 Net2 Modem adaptor
Further documentation 'Installing remote sites using modems' and 'Conguring site manager' is available for
download at: http://paxton.info/53 and http://paxton.info/52 respectively. Alternatively call the communications
team on: 01273 811011.
Connection to
modem
Technical Support
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
01273 811011 [email protected]
26/09/2011
Paxton
0V 12V
Net2 Modem Adaptor
Orange
White/orange
Green
White/green
Do not connect
0V
Wiring
12V DC
power supply
230V AC
input
12V output. Total load
including converter
should not exceed 1A
IMPORTANT: THIS IS
NOT AN INPUT
ALL OTHER SPARE
CORES
The converter can be installed at either end of the data line or anywhere along the data line.
120 ohm terminating resistors must be linked across each data pair at the beginning AND end of the line.
This can be done on many units with a switch or jumpers. If not, free resistors are provided with the
converter. If the data line extends past 1 km an RS485 repeater (447-836/477-844) is required.
Termination
1 km max
Resistor x 2
Ins-30073 Net2 Modem adaptor
Further documentation 'Installing remote sites using modems' and 'Conguring site manager' is available for
download at: http://paxton.info/53 and http://paxton.info/52 respectively. Alternatively call the communications
team on: 01273 811011.
Connection to
modem
Technical Support
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
01273 811011 [email protected]
Paxton
/