BENDIX TCH-001-058 is a technical bulletin that provides information on sound emitted by externally unloaded compressors. It explains that the continuous exhaust flow of air from DLU compressors may be mistakenly diagnosed as air system leakage. The bulletin recommends installing an approved vent hose or tube to relocate or redirect the exhaust noise, or installing an approved silencer at the exhaust outlet of the component relieving the pressure.

BENDIX TCH-001-058 is a technical bulletin that provides information on sound emitted by externally unloaded compressors. It explains that the continuous exhaust flow of air from DLU compressors may be mistakenly diagnosed as air system leakage. The bulletin recommends installing an approved vent hose or tube to relocate or redirect the exhaust noise, or installing an approved silencer at the exhaust outlet of the component relieving the pressure.

Technical Bulletin
Bulletin No: Effective Date: Cancels: Page: 1 of
Subject:
TCH-001-058
5-20-2010
N/A
2
Sound Emitted by Externally Unloaded Compressor
This bulletin identi es a concern that can be mistakenly diagnosed as air system leakage.
Unloading air compressors externally, by means of allowing discharge air to be vented to atmosphere
rather than internally unloading the compressor, to stop the building of air system pressure is commonly
referred to as Discharge Line Unloading or DLU. In the unloaded mode DLU compressors provide a
continuous exhaust ow of air to atmosphere. This exhaust ow of air may be mistakenly diagnosed as
air system leakage. Although this ow of air is normal, the concern can be minimized by installing an
approved vent hose, or tube, to relocate or redirect the exhaust noise or by installing an approved silencer
at the exhaust outlet of the component relieving the pressure.
Note that using a DLU purge valve in an air brake system that has a turbo charged air compressor inlet,
will result in loss of turbo pressure out of the dryer thereby, reducing engine power.
Bendix Commercial Vehicle Systems LLC is aware of two common means of externally unloading the air
compressor for air braked systems in use today, either through the air dryer or an external unloader valve.
The rst method is using an air dryer with a discharge line unloading (DLU) style purge valve assembly to
allow the compressor discharge air to be vented to atmosphere under the control of the normal air system
governor. The partial system sketch below illustrates the charging, treatment, and storage portion of an
air brake system utilizing the air dryer as the means of externally unloading the compressor. Note that
most Bendix
®
air dryers typically include a turbo cut-off purge valve design. To use the air dryer in the
manner illustrated, a DLU style purge valve is required.
Discharge Line Unloading with Air Dryer and DLU Style Purge Valve
Continued...
The Silencer Kit for use on AD-9
®
, AD-IP
®
, and AD-IS
®
air dryers is part number 5004224.
FRONT SERVICE
REAR SERVICE
AD-IP
®
AIR DRYER
WITH MUFFLER
SINGLE
CHECK
VALVE
SINGLE
CHECK
VALVE
D-2
®
GOVERNOR
D
S
UNL
RES
SUPPLY
COMPRESSOR
COMPRESSOR
DISCHARGE LINE
Bulletin No: Page: 2 of
TCH-001-058
2
© 2010 Bendix Commercial Vehicle Systems LLC All rights reserved. 5/2010 Printed in U.S.A.
COMPRESSOR
FRONT SERVICE
REAR SERVICE
D-2
®
GOVERNOR
AS PART OF
AD-IS
®
AIR DRYER
UNLOADER VALVE
WITH SILENCER
21
22
S
S
C
UNL
C
COMPRESSOR
DISCHARGE
LINE
Discharge Line Unloading with DRO Unloader Valve
The second method of externally unloading the compressor is by using a separate DRO Unloader Valve.
This valve is also normally controlled by the air system governor and may be installed in parallel or in
series with the air dryer. The partial system sketch below illustrates the charging, treatment, and storage
portion of the system utilizing a DRO unloader valve in parallel as the means of unloading the compressor
in combination with the dryer.
Note the DRO valve can be used with any style Bendix
®
air dryer; however, the DRO valve will not prevent
turbocharged air loss.
The Silencer Kit for use with the DRO Unloader Valve is part number K029328.
  • Page 1 1
  • Page 2 2

BENDIX TCH-001-058 User manual

Type
User manual

BENDIX TCH-001-058 is a technical bulletin that provides information on sound emitted by externally unloaded compressors. It explains that the continuous exhaust flow of air from DLU compressors may be mistakenly diagnosed as air system leakage. The bulletin recommends installing an approved vent hose or tube to relocate or redirect the exhaust noise, or installing an approved silencer at the exhaust outlet of the component relieving the pressure.