Altronix AL842ULADA Datasheet

Category
Power adapters & inverters
Type
Datasheet

Altronix AL842ULADA is a cost-effective voltage-regulated remote NAC Power Extender that seamlessly integrates with 24V Fire Alarm Control Panels (FACPs). It offers versatile NAC expansion (adhering to ADA requirements), providing auxiliary power for system accessories. With four Class A or B outputs and two Class A or B FACP inputs, it ensures reliable signal distribution. Two NC dry contact trigger inputs and four Class A or B indicating circuits enhance system flexibility. It supports paralleling of two Class B outputs for increased power on indicating circuits. The device includes an Aux.

Altronix AL842ULADA is a cost-effective voltage-regulated remote NAC Power Extender that seamlessly integrates with 24V Fire Alarm Control Panels (FACPs). It offers versatile NAC expansion (adhering to ADA requirements), providing auxiliary power for system accessories. With four Class A or B outputs and two Class A or B FACP inputs, it ensures reliable signal distribution. Two NC dry contact trigger inputs and four Class A or B indicating circuits enhance system flexibility. It supports paralleling of two Class B outputs for increased power on indicating circuits. The device includes an Aux.

•24VDCrated@8ampmax.
•Four(4)ClassAorfour(4)ClassBoutputs.
•Two(2)ClassAortwo(2)ClassBFACPinputs.
•Two(2)NCdrycontacttriggerinputs.
•Four(4)ClassAorfour(4)ClassB
indicatingcircuits.
•Two(2)ClassBoutputsmaybeparalleledformore
poweronanindicatingcircuit.
•One(1)Aux.PowerOutput@1ampsupplycurrent
(w/batterybackup).
•One(1)Aux.PowerOutput@1ampsupplycurrent
(w/obatterybackup).
•SignalCircuitTroubleMemory-facilitatesquickly
locatingintermittentsystemtroubleandeliminates
costlyandunnecessaryservicecalls.LEDsindicatea
priorfault(short,open,ground)hasoccurredonone
ormoresignalingcircuitoutputs.
•2-wireHorn/StrobeSyncmodeallowsaudible
notificationappliances(Horns)tobesilencedwhile
visualnotificationappliances(Strobes)continue
tooperate.
•Horn/Strobesyncprotocolsinclude:Gentex®,
SystemSensor®,Faraday,Amseco.
•TemporalCode3Mode.
•SteadyMode.
•InputtoOutputFollowerMode(maintains
synchronizationofnotificationappliancecircuits).
•MarchTime.
•Compatiblewith24VDCfirepanels.
•Groundfaultdetection.
•Input115VAC.
•ACfailsupervision(form“C”contacts).
•Lowbatterysupervision(form“C”contacts).
•Batterypresencesupervision(form“C”contacts).
•Powersupply,logicboard,redenclosure,camlock,
transformer&batteryleads.
•Enclosure:
- Combinationknockoutsre1/2”and3/4”
- Accommodatesuptotwo(2)
12VDC/12AHbatteries.
AL842ULADAweights:
Productweight:14.8lbs.
Shippingweight:19.15lbs.
AL842ULADA
NAC Power Extenders
Rev.AL842ULADA_A27K
Overview
Specifications
Agency Approvals
TheAL842ULADAareextremelycosteffectivevoltageregulatedremoteNAC
PowerExtenders.Theymaybeconnectedtoany24voltFireAlarmControl
Panel(FACP).PrimaryapplicationsincludeNotificationApplianceCircuit(NAC)
expansion(supportsADArequirements)andwillprovideauxiliarypowertosup-
portsystemaccessories.
ULListedControlUnitsandAccessories
forFireAlarmSystems(UL864),
FactoryMutualApproved.
NYCDepartmentofBuildingsApproved.
CaliforniaStateFireMarshalApproved.
Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com
Enclosure Dimensions
18”Hx14.5”Wx4.625”D
18"
18"
14.5"
14.5"
4.5"
4.5"
4.5"
4.5"
4.5"
1.25"
1.5"
4.0"6.5"1.5"
1.25"
1.5"
4.0"
10.0"
1.25"
2.75"
7.25"
1.0"
1.5"
1.0"
1.0"
1.0"
1.25"
2.75"
1.5"
10"
  • Page 1 1
  • Page 2 2

Altronix AL842ULADA Datasheet

Category
Power adapters & inverters
Type
Datasheet

Altronix AL842ULADA is a cost-effective voltage-regulated remote NAC Power Extender that seamlessly integrates with 24V Fire Alarm Control Panels (FACPs). It offers versatile NAC expansion (adhering to ADA requirements), providing auxiliary power for system accessories. With four Class A or B outputs and two Class A or B FACP inputs, it ensures reliable signal distribution. Two NC dry contact trigger inputs and four Class A or B indicating circuits enhance system flexibility. It supports paralleling of two Class B outputs for increased power on indicating circuits. The device includes an Aux.