red lion NT24k Series User manual

Category
Network switches
Type
User manual
June 2015
N-Tron
®
Series
NT24k
TM
Compact Industrial Managed Gigabit Ethernet Switches
Hardware Manual
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015)
CHANGE HISTORY
Revised Date Description
February 2015 Initial Release.
June 2, 2015 New models added.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 3
Warnings / Avertissements
GENERAL WARNINGS / AVERTISSEMENTS GÉNÉRAUX
WARNING - Do not remove any of the covers. There are no serviceable parts within the unit.
AVERTISSEMENT - Ne retirez aucun des couvercles. Il n'y a pas des pieces utilisables à l'intérieur de l'appareil.
WARNING - Do not substitute unauthorized parts or make unauthorized modifications to the unit.
AVERTISSEMENT - Ne pas remplacer les pièces non-autorisées ou effectuer des modifications non-autorisées de l'appareil.
WARNING - Do not operate the unit with the top cover removed, as this could create a shock or fire hazard.
AVERTISSEMENT - Ne pas faire fonctionner l'unité avec le couvercle retiré, ceci pourrait créer une décharge électrique ou un incendie.
WARNING - Do not block any air vents on the unit.
AVERTISSEMENT - N'obstruez pas les fentes d'aération de l'unité.
WARNING - Do not operate the equipment in the presence of flammable gasses or fumes. Operating electrical equipment in such an
environment constitutes a definite safety hazard.
AVERTISSEMENT - Ne pas utiliser le matériel en présence de gaz ou de vapeurs inflammables. L'utilisation de matériel électrique dans
un tel environnement constitue un danger certain.
WARNING - Do not operate the equipment in a manner not specified by this manual.
AVERTISSEMENT - Ne pas faire fonctionner l'équipement d'une manière non spécifiée par ce manuel.
GENERAL SAFETY WARNING / AVERTISSEMENTS GÉNÉRAUX DE SÉCURITÉ
WARNING - If the equipment is used in a manner not specified by Red Lion, the protection provided by the equipment may be
impaired.
AVERTISSEMENT - Si l'équipement est utilisé d'une manière non spécifiée par Red Lion, la protection fournie par l'équipement peut
être compromise.
ENVIRONMENTAL SAFETY / SÉCURITÉ ENVIRONMENTALE
WARNING - Disconnect the power and allow to cool 5 minutes before touching.
AVERTISSEMENT - Déconnectez le câble d'alimentation et laisser refroidir 5 minutes avant de la toucher.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 4
ELECTRICAL SAFETY / SÉCURITÉ ÉLECTRIQUE
WARNING - Properly ground the unit before connecting anything else to the unit. Units not properly grounded may result in a safety
risk and could be hazardous and may void the warranty. See the grounding technique section of this manual for proper ways to ground
the unit.
AVERTISSEMENT - L'unité doit être correctement mise à la terre avant tout raccordement à l'unité. Unités pas correctement mise à la
terre peuvent causer un risque de sécurité et pourraient être dangereuses et peuvent annuler la garantie. Voir la section technique de
mise à la terre dans ce mode d'emploi pour des moyens appropriés à la masse de l'appareil.
WARNING - Never install or work on electrical equipment or cabling during periods of lightning activity.
AVERTISSEMENT - Ne jamais installer ou travailler sur équipement électrique ou de câblage pendant les périodes d'activité de la fou-
dre.
WARNING - Do not perform any services on the unit unless qualified to do so.
AVERTISSEMENT - Ne pas effectuer de services sur l'appareil si vous n'êtes pas qualifié pour le faire.
WARNING - Observe proper DC Voltage polarity when installing power input cables. Reversing voltage polarity can cause permanent
damage to the unit and void the warranty.
AVERTISSEMENT - Respectez la polarité correcte de tension DC lors de l'installation des câbles d'alimentation d'entrée. Inversion de
polarité de tension peut causer des dommages permanents à l'appareil et annule la garantie.
HAZARDOUS LOCATION AND INSTALLATION REQUIREMENTS / AVERTISSEMENTS POUR
INSTALLATION ET ENDROITS DANGEREUX
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D, or non-hazardous locations only. Combinations of equip-
ment in your system are subject to investigation by the local authority having jurisdiction at the time of installation.
Cet appareil est adapté pour utilisation en Classe I, Division 2, Groupes A, B, C, D ou endroits non-dangereux seulement. Combinaisons
d'équipements de votre système sont objet d'une enquête par l'autorité locale compétente au moment de l'installation.
These devices are open-type devices that are to be installed in an enclosure suitable for the environment.
Cest appareils sont type ouvert et doivent être installés dans un boîtier adapté à l'environnement.
WARNING – EXPLOSION HAZARD – Substitution of components may impair suitability for Class I, Division 2.
AVERTISSEMENT – RISQUE D’EXPLOSION – La substitution de tout composant peut nuire à la conformité de Classe 1, Division 2.
WARNING – EXPLOSION HAZARD – Do not connect or disconnect any connections while circuit is live, unless area is known to be non-
hazardous.
AVERTISSEMENT – RISQUE D’EXPLOSION – Lorsque dans des endroits dangereux, ne pas brancher ou débrancher les connexions lor-
sque le circuit est sous tension.
WARNING – EXPLOSION HAZARD – Do not replace the device unless power has been switched off or the area is known to be non-haz-
ardous.
AVERTISSEMENT – RISQUE D’EXPLOSION - Ne pas remplacer l’appareil à moins que l’alimentation a été coupée ou que la zone est
connue pour être non-dangereuse.
WARNING - Exposure to some chemicals may degrade the sealing properties of materials used in the Relay U1.
AVERTISSEMENT - L'exposition à certains produits chimiques peut dégrader les propriétés d'étanchéité des matériaux utilisés dans
les Relais U1.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 5
WARNING - Never install or work on electrical equipment or cabling during periods of lightning activity.
AVERTISSEMENT - Ne jamais installer ou travailler sur équipement électrique ou câblage pendant les périodes d'activité de la foudre.
WARNING - Never connect or disconnect power when hazardous gasses are present.
AVERTISSEMENT - Ne jamais brancher ou débrancher l’alimentation lorsqu’en presence de gaz dangereux.
WARNING - Disconnect the power cable before removing any enclosure panel.
AVERTISSEMENT - Débranchez le cable d’alimentation avant de retired le panneau du châssis.
SURROUNDING AIR TEMPERATURE / TEMPERATURE AMBIANTE -
NT24k models without PoE (Power over Ethernet) option: -40 °C to 85 °C
NT24k PoE models: -40 °C to 80 °C
Note - Use 110 °C or higher rated copper wire, (0.22NM) 2lb/in tightening torque for field installed conductors. / Note: Utilisez fil de
cuivre classé 110 °C ou plus, (0.22Nm) 2 pouces/livres couple de serrage pour les connecteurs installés sur le terrain.
LASER SAFETY / SÉCURITÉ POUR LASER
CAUTION- Class 1 Laser Product. Do not stare into the laser.
CAUTION - Produit laser Classe 1. Ne pas regarder dans le laser.
Note - Please reference section 1.24 for all models with lasers present. / S'il vous plaît consulter la section 1.24 pour tous les modèles
avec lasers.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 6
FCC Statement
This product complies with Part 15 of the FCC-A Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful Interference
2. This device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equip-
ment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. Operation of this device in a residential area is likely to cause harmful interfer-
ence in which case the user will be required to correct the interference at his/her own expense.
Déclaration de conformité FCC
Ce produit est conforme à la partie 15 des règles de la FCC -A
Utilisation est soumise aux conditions suivantes:
1. Ce dispositif ne doit pas causer des interférences nuisibles
2. Cet appareil doit accepter toute interférence reçue, y compris les interférences qui peuvent causer un mauvais fonctionne-
ment.
Note: Cet équipement a été testé et jugé conforme aux limites de la classe A des appareils numériques, conformément à la partie 15
des règles de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une
installation résidentielle. Cet équipement génère, utilise et peut émettre de l'énergie radiofréquence et, si il n’est pas installé et utilisé
conformément aux instructions, peut causer des interférences nuisibles aux communications radio. L'utilisation de cet appareil dans
une zone résidentielle est susceptible de provoquer des interférences nuisibles, auquel cas l'utilisateur sera tenu de corriger les inter-
férences à ses propres frais.
Industry Canada / Industrie Canada
This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is sub-
ject to the following two conditions; (1) this device may not cause harmful interference, and (2) this device must accept any interfer-
ence received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant des règlements d'équi-
pement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce dis-
positif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée.
Trademark and Registration Acknowledgments
EtherNet/IP
TM
and CIP
TM
are trademarks of ODVA.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 7
Chapter 1 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.1 NT24kTM Series Common Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.2 NT24k-8TX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.3 NT24k-16TX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.4 NT24k-10FX2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.5 NT24k-10GX2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
1.6 NT24k-11FX3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
1.7 NT24k-11GX3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1.8 NT24k-12FX4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
1.9 NT24k-12GX4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
1.10 NT24k-14FX6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
1.11 NT24k-14GX6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
1.12 NT24k-12SFP-DM4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
1.13 NT24k-8TX-POE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
1.14 NT24k-10FX2-POE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
1.15 NT24k-10GX2-POE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
1.16 NT24k-11FX3-POE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
1.17 NT24k-11GX3-POE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
1.18 NT24k-12FX4-POE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
1.19 NT24k-12GX4-POE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
1.20 NT24k-14FX6-POE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
1.21 NT24k-14GX6-POE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
1.22 NT24k-12SFP-DM4-POE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
1.23 LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
1.24 Transceiver Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
1.25 Ordering Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Chapter 2 Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
2.1 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
2.2 Mounting the NT24k Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
2.3 Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
2.4 Grounding the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
2.5 Configurable Alarm Contact. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
2.6 Connecting the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
2.7 Ethernet Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
2.8 NTCD-CFG Configuration Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
2.9 USB Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
2.10 Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Chapter 3 Accessing the Web Software Interface. . . . . . . . . . . . . . . . . . 92
Service and Support Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 8
NT24kTM Series Common Features
Chapter 1 Product Overview
1.1 NT24k
TM
Series Common Features
Red Lion's N-Tron® series NT24k Compact Gigabit managed industrial Ethernet switches offer a wide array of port
configurations, media types, and Power over Ethernet. Modular NT24k models are also available. Please see the NT24k
Modular Series Hardware Manual for more information.
All NT24k switches offer plug-and-play installation with IGMP auto-configuration, media/port auto-detection and simple
ring configuration, making the NT24k platform one of the easiest to deploy managed switches in the industry. Housed in
rugged hardened enclosures, the NT24k switches feature extended shock and vibration specifications, wide operating
temperature ratings and best-in-class ring technology.
Connectivity
The NT24k compact switches offer a wide array of port configurations, media types and Power over Ethernet models with
10/100/1000 copper, as well as Fast Ethernet and Gigabit fiber options. For maximum flexibility, the compact models are
available with copper only ports or a mix of copper and fiber ports. IEEE 802.3af/at PoE models are also available.
Performance
NT24k managed switches provide uncompromising performance in harsh environments, including network features like
N-Ring, VLAN, Quality of Service (QoS), port mirroring, IGMP, SNTP and SNMP. Additionally the NT24k offers IEEE 802.1x
with RADIUS remote server authentication to ensure port security. These network management features provide best-in-
class visibility, security and uptime performance.
Environmental
The ultra-reliable NT24k compact switches are DIN-Rail mountable, and offer operating temperatures up to -40 °C to
85 °C. With UL Class I, Division 2 listing and CE certifications, these industrial switches are built to last in the most
demanding and hazardous environments.
Monitoring
The N-View
monitoring technology provided with the switch provides 47 different status points on switch and port
conditions and displays that information on any networked computer.
Security
The NT24k series provides a high level of security utilizing IEEE 802.1x with RADIUS remote server authentication and
SNMPv3 communication protocol to ensure the safest networks.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 9
NT24kTM Series Common Features
Available Models
* See section 1.25.6 for available Fast Ethernet and Gigabit SFP transceivers
Part #
Total
Ports
Mounting
Operating
Temperature
10/100/1000
Copper
100 Fiber Gig Fiber SFPs*
10-49 VDC
Redundant
Power Input
22-49 VDC
Redundant
Power Input
NT24k-8TX 8 DIN-Rail -40 °C to 85 °C 8 - - -
NT24k-16TX 16 DIN-Rail -40 °C to 85 °C 16 - - -
NT24k-10FX2 10 DIN-Rail -40 °C to 85 °C 8 2 - -
NT24k-10GX2 10 DIN-Rail -40 °C to 85 °C 8 - 2 -
NT24k-11FX3 11 DIN-Rail -40 °C to 85 °C 8 3 - -
NT24k-11GX3 11 DIN-Rail -40 °C to 85 °C 8 - 3 -
NT24k-12FX4 12 DIN-Rail -40 °C to 85 °C 8 4 - -
NT24k-12GX4 12 DIN-Rail -40 °C to 85 °C 8 - 4 -
NT24k-14FX6 14 DIN-Rail -40 °C to 85 °C 8 6 - -
NT24k-14GX6 14 DIN-Rail -40 °C to 85 °C 8 - 6 -
NT24k-12SFP-DM4 12 DIN-Rail -40 °C to 85 °C 8 - - Up to 4
NT24k-8TX-POE 8 DIN-Rail -40 °C to 80 °C 8 (8 PoE+) - - -
NT24k-10FX2-POE 10 DIN-Rail -40 °C to 80 °C 8 (8 PoE+) 2 - -
NT24k-10GX2-POE 10 DIN-Rail -40 °C to 80 °C 8 (8 PoE+) - 2 -
NT24k-11FX3-POE 11 DIN-Rail -40 °C to 80 °C 8 (8 PoE+) 3 - -
NT24k-11GX3-POE 11 DIN-Rail -40 °C to 80 °C 8 (8 PoE+) - 3 -
NT24k-12FX4-POE 12 DIN-Rail -40 °C to 80 °C 8 (8 PoE+) 4 - -
NT24k-12GX4-POE 12 DIN-Rail -40 °C to 80 °C 8 (8 PoE+) - 4 -
NT24k-14FX6-POE 14 DIN-Rail -40 °C to 80 °C 8 (8 PoE+) 6 - -
NT24k-14GX6-POE 14 DIN-Rail -40 °C to 80 °C 8 (8 PoE+) - 6 -
NT24k-12SFP-DM4-POE 12 DIN-Rail -40 °C to 80 °C 8 (8 PoE+) - - Up to 4
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 10
NT24k-8TX
1.2 NT24k-8TX
The versatile NT24k-8TX managed switch features eight all-Gigabit copper Ethernet ports housed in a hardened metal
DIN-rail enclosure with redundant 10-49 VDC power inputs. Designed to handle the most demanding environments, the
NT24k-8TX offers wire-speed throughput, expanded shock and vibration ratings and wide -40 °C to 85 °C operating
temperature ratings. IGMP auto-configuration, IEEE 802.1x port-based network access control with RADIUS remote
server authentication and Multi-Member N-Ring
TM
fast healing ring technology ensure quick deployment and robust
secure network communications in alternative energy, transportation, water/wastewater and manufacturing
applications.
1.2.1 Features and Benefits
Features and Benefits
> Eight 10/100/1000Base-T(X) RJ45 Ports
Easily transitions to Gigabit network requirements
> Redundant 10 to 49 VDC Power Inputs
Keeps network running in the event of a power supply
failure.
> Extended Environmental Specifications
-40 °C to 85 °C operating temperature range
> 2M hours MTBF
UL/cUL: Class I, Div 2 Groups A, B, C and D
> Plug-and-Play Operation
IGMP auto-configuration
Automatic port detection and setup
Simple network ring configuration
Backup and restore via NTCD-CFG configuration device
or XML
> Safety
ESD Protection: 8KV Contact, 15KV Air
> Fully Managed Features Include:
Jumbo frame support
SNMP v1, v2, v3
Web browser management
Detailed ring map and fault location charting
RSTP - 802.1d, 802.1w, 802.1D
Trunking and port mirroring
802.1Q VLAN Tagging and port VLAN
IEEE 802.1x RADIUS remote server authentication
802.1p QoS, port QoS and DSCP
DHCP client
SNTP (Simple Network Time Protocol)
Multi-Member N-Ring technology with ~30ms
healing
N-Link™ redundant ring technology
N-View monitoring technology
Ethernet/IP™ CIP™ messaging
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 11
NT24k-8TX
1.2.2 Specifications
POWER INPUT
Input Voltage: 10 - 49 VDC
Steady Input Current: 490 mA @ 24 VDC
Inrush: 22 A / .33 ms @ 24 VDC
BTU/HR: 40.14
CONNECTORS
10/100/1000BaseT: Eight RJ45 TX ports
ENVIRONMENTAL
Operating Temperature: -40 °C to 85 °C
Storage Temperature: -40 °C to 85 °C
Operating Humidity: 10% to 95% (non condensing)
Operating Altitude: 0 to 10,000 ft.
Shock: 200 g @ 10 ms (bulkhead mounted)
Vibration: 50 g @ 5-200 Hz, Triaxial (bulkhead mounted)
MECHANICAL
Case Dimensions:
Height: 5.88” (14.92 cm)
Width: 2.22” (5.64 cm)
Depth: 5.54” (14.07 cm)
Weight: 1.68 lbs (0.76 kg)
Mount: 35 mm DIN-Rail
RECOMMENDED WIRING CLEARANCE
Front: 2” (5.08 cm)
Top: 4” (10.16 cm)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 12
NT24k-8TX
1.2.3 Dimensions
All specifications are subject to change. Consult the company website for more information.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 13
NT24k-16TX
1.3 NT24k-16TX
The versatile NT24k-16TX managed switch features 16 all-Gigabit copper Ethernet ports housed in a hardened metal DIN-
rail enclosure with redundant 10-49 VDC power inputs. Designed to handle the most demanding environments, the
NT24k-16TX offers wire-speed throughput, expanded shock and vibration ratings and wide -40 °C to 85 °C operating
temperature ratings. IGMP auto-configuration, IEEE 802.1x port-based network access control with RADIUS remote
server authentication and Multi-Member N-Ring fast healing technology ensure quick deployment and robust secure
network communications in alternative energy, transportation, water/wastewater and manufacturing applications.
1.3.1 Features and Benefits
Features and Benefits
> 16 10/100/1000Base-T(X) RJ45 Ports
Easily transitions to Gigabit network requirements
> Redundant 10 to 49 VDC Power Inputs
Keeps network running in the event of a power supply
failure
> Extended Environmental Specifications
-40 °C to 85 °C operating temperature range
> 2M hours MTBF
UL/cUL: Class I, Div 2 Groups A, B, C and D
> Plug-and-Play Operation
IGMP auto-configuration
Automatic port detection and setup
Simple network ring configuration
Backup and restore via NTCD-CFG configuration device
or XML
> Safety
ESD Protection: 8KV Contact, 15KV Air
> Fully Managed Features Include:
Jumbo frame support
SNMP v1, v2, v3
Web browser management
Detailed ring map and fault location charting
RSTP - 802.1d, 802.1w, 802.1D
Trunking and port mirroring
802.1Q VLAN Tagging and port VLAN
IEEE 802.1x RADIUS remote server authentication
802.1p QoS, port QoS and DSCP
DHCP client
SNTP (Simple Network Time Protocol)
Multi-Member N-Ring technology with ~30ms
healing
N-Link redundant ring technology
N-View monitoring technology
Ethernet/IP CIP messaging
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 14
NT24k-16TX
1.3.2 Specifications
POWER INPUT
Input Voltage: 10 - 49 VDC
Steady Input Current: 710 mA @ 24 VDC
Inrush: 22 A / .33 ms @ 24 VDC
BTU/HR: 58.14
CONNECTORS
10/100/1000BaseT: 16 RJ45 TX ports
ENVIRONMENTAL
Operating Temperature: -40 °C to 85 °C
Storage Temperature: -40 °C to 85 °C
Operating Humidity: 10% to 95% (non condensing)
Operating Altitude: 0 to 10,000 ft.
Shock: 200 g @ 10 ms (bulkhead mounted)
Vibration: 50 g @ 5-200 Hz, Triaxial (bulkhead mounted)
MECHANICAL
Case Dimensions:
Height: 5.88” (14.92 cm)
Width: 3.10” (7.87 cm)
Depth: 5.54” (14.07 cm)
Weight: 1.97 lbs (0.89 kg)
Mount: 35 mm DIN-Rail
RECOMMENDED WIRING CLEARANCE
Front: 2” (5.08 cm)
Top: 4” (10.16 cm)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 15
NT24k-16TX
1.3.3 Dimensions
All specifications are subject to change. Consult the company website for more information.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 16
NT24k-10FX2
1.4 NT24k-10FX2
The versatile NT24k-10FX2 managed switch features 10 Ethernet ports (eight Gigabit copper ports and two 100Base fiber
ports) and is housed in a compact, hardened metal DIN-rail enclosure with redundant 10-49 VDC power inputs. Designed
to handle the most demanding environments, the NT24k-10FX2 offers wire-speed throughput, expanded shock and
vibration ratings and wide -40 °C to 85 °C operating temperature rating. IGMP auto-configuration, IEEE 802.1x with
RADIUS remote server authentication and N-Ring fast healing ring technology ensure quick deployment and robust
secure network communications in alternative energy, factory automation applications, transportation and water/
wastewater.
1.4.1 Features and Benefits
Features and Benefits
> 10 Copper and Fiber Ports
Eight 10/100/1000Base-T(X) copper ports
Two 100BaseFX fiber ports
> Redundant 10 to 49 VDC Power Inputs
Keeps network running in the event of a power supply
failure
> Extended Environmental Specifications
-40 °C to 85 °C operating temperature range
> 2M hours MTBF
UL/cUL: Class I, Div 2 Groups A, B, C and D
> Plug-and-Play Operation
IGMP auto-configuration
Automatic port detection and setup
Simple network ring configuration
Backup and restore via NTCD-CFG configuration device
or XML
> Safety
ESD Protection: 8KV Contact, 15KV Air
> Fully Managed Features Include:
Jumbo frame support
SNMP v1, v2, v3
Web browser management
Detailed ring map and fault location charting
RSTP - 802.1d, 802.1w, 802.1D
Trunking and port mirroring
802.1Q VLAN Tagging and port VLAN
IEEE 802.1x RADIUS remote server authentication
802.1p QoS, port QoS and DSCP
DHCP client
SNTP (Simple Network Time Protocol)
Multi-Member N-Ring technology with ~30ms
healing
N-Link redundant ring technology
N-View monitoring technology
Ethernet/IP CIP messaging
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 17
NT24k-10FX2
1.4.2 Specifications
POWER INPUT
Input Voltage: 10 - 49 VDC
Steady Input Current: 750 mA @ 24 VDC
Inrush: 21 A / .30 ms @ 24 VDC
BTU/HR: 61.44
CONNECTORS
10/100/1000BaseT: Eight RJ45 copper ports
100BaseFX: Two SC or ST duplex fiber ports
ENVIRONMENTAL
Operating Temperature: -40 °C to 85 °C
Storage Temperature: -40 °C to 85 °C
Operating Humidity: 10% to 95% (non condensing)
Operating Altitude: 0 to 10,000 ft.
Shock: 200 g @ 10 ms (bulkhead mounted)
Vibration: 50 g @ 5-200 Hz, Triaxial (bulkhead mounted)
MECHANICAL
Case Dimensions:
Height: 5.88” (14.92 cm)
Width: 3.10” (7.87 cm)
Depth: 5.54” (14.07 cm)
Weight: 1.95 lbs (0.89 kg)
Mount: 35 mm DIN-Rail
RECOMMENDED WIRING CLEARANCE
Front: 4” (10.16 cm)
Top: 4” (10.16 cm)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 18
NT24k-10FX2
1.4.3 Dimensions
All specifications are subject to change. Consult the company website for more information.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 19
NT24k-10GX2
1.5 NT24k-10GX2
The versatile NT24k-10GX2 managed switch features 10 Ethernet ports (eight Gigabit copper ports and two 1000Base
fiber ports) housed in a hardened metal DIN-rail enclosure with redundant 10-49 VDC power inputs. Designed to handle
the most demanding environments, the NT24k-10GX2 offers wire-speed throughput, expanded shock and vibration
ratings and wide -40 °C to 85 °C operating temperature ratings. IGMP auto-configuration, IEEE 802.1x port-based network
access control with RADIUS remote server authentication and Multi-Member N-Ring fast healing technology ensure quick
deployment and robust secure network communications in alternative energy, transportation, water/wastewater and
manufacturing applications
1.5.1 Features and Benefits
Features and Benefits
> 10 Copper and Fiber Ports
Eight 10/100/1000Base-T(X) copper ports
Two 1000BaseFX fiber ports
> Redundant 10 to 49 VDC Power Inputs
Keeps network running in the event of a power supply
failure
> Extended Environmental Specifications
-40 °C to 85 °C operating temperature range
> 2M hours MTBF
UL/cUL: Class I, Div 2 Groups A, B, C and D
> Plug-and-Play Operation
IGMP auto-configuration
Automatic port detection and setup
Simple network ring configuration
Backup and restore via NTCD-CFG configuration device
or XML
> Safety
ESD Protection: 8KV Contact, 15KV Air
> Fully Managed Features Include:
Jumbo frame support
SNMP v1, v2, v3
Web browser management
Detailed ring map and fault location charting
RSTP - 802.1d, 802.1w, 802.1D
Trunking and port mirroring
802.1Q VLAN Tagging and port VLAN
IEEE 802.1x RADIUS remote server authentication
802.1p QoS, port QoS and DSCP
DHCP client
SNTP (Simple Network Time Protocol)
Multi-Member N-Ring technology with ~30ms
healing
N-Link redundant ring technology
N-View monitoring technology
Ethernet/IP CIP messaging
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
NT24k Compact Series - Hardware Manual (Revised 06-02-2015) 20
NT24k-10GX2
1.5.2 Specifications
POWER INPUT
Input Voltage: 10 - 49 VDC
Steady Input Current: 780 mA @ 24 VDC
Inrush: 22.6 A / .30 ms @ 24 VDC
BTU/HR: 63.89
CONNECTORS
10/100/1000BaseT: Eight RJ45 copper ports
1000BaseFX: Two SC duplex fiber ports
ENVIRONMENTAL
Operating Temperature: -40 °C to 85 °C
Storage Temperature: -40 °C to 85 °C
Operating Humidity: 10% to 95% (non condensing)
Operating Altitude: 0 to 10,000 ft.
Shock: 200 g @ 10 ms (bulkhead mounted)
Vibration: 50 g @ 5-200 Hz, Triaxial (bulkhead mounted)
MECHANICAL
Case Dimensions:
Height: 5.88” (14.92 cm)
Width: 3.10” (7.87 cm)
Depth: 5.54” (14.07 cm)
Weight: 1.95 lbs (0.89 kg)
Mount: 35 mm DIN-Rail
RECOMMENDED WIRING CLEARANCE
Front: 4” (10.16 cm)
Top: 4” (10.16 cm)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95

red lion NT24k Series User manual

Category
Network switches
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI