MicroNet SP5220 User manual

Type
User manual

MicroNet SP5220 is a centrally managed solution for Micronet VoIP devices, allowing easy setup and configuration without the need for reconfiguring device settings. It includes EMSClient for uploading configurations and firmware, and EMS Server for collecting logs and controlling the VoIP environment. SP5220 communicates with EMSClient to upload CPE configurations and firmware to the EMS Server, accepts CPE connection requests, and supports various logs and statistics.

MicroNet SP5220 is a centrally managed solution for Micronet VoIP devices, allowing easy setup and configuration without the need for reconfiguring device settings. It includes EMSClient for uploading configurations and firmware, and EMS Server for collecting logs and controlling the VoIP environment. SP5220 communicates with EMSClient to upload CPE configurations and firmware to the EMS Server, accepts CPE connection requests, and supports various logs and statistics.

Users Manual
VoIP EMS Server
Model No.: SP5220
http://www.micronet.info
Table of Contents
CHAPTER 1 INTRODUCTION...........................................................................................................................1
CHAPTER 2 FEATURES...................................................................................................................................2
CHAPTER 3 CONFIGURATION........................................................................................................................3
ENVIRONMENT..................................................................................................................................................3
APPEARANCE DESCRIPTION ..............................................................................................................................3
MONITORING CONNECTING STATUS ....................................................................................................................4
OPERATION ......................................................................................................................................................5
CHAPTER 4 INSTALLING EMSCLIENT...........................................................................................................6
SYSTEM REQUIREMENTS...................................................................................................................................6
INSTALLING EMSCLIENT ...................................................................................................................................6
UNINSTALL EMSCLIENT....................................................................................................................................9
CHAPTER 5 CONFIGURING EMSCLIENT.....................................................................................................11
EMS SERVER SETTING...................................................................................................................................11
EMS SERVER SETTING...................................................................................................................................11
RESET AND RESTART EMS SERVER................................................................................................................12
UPGRADE EMS SERVER.................................................................................................................................12
EMSCLIENT ACCOUNT....................................................................................................................................13
GATEWAY ACCOUNT........................................................................................................................................14
FIRMWARE SETTING........................................................................................................................................15
CONFIGURATION SETTING [SIP] ......................................................................................................................16
CONFIGURATION SETTING [H323]....................................................................................................................18
OPERATION ....................................................................................................................................................19
FILES ON EMS SERVER..................................................................................................................................20
C.P.E STATUS..............................................................................................................................................21
EMS SERVER HISTORY...................................................................................................................................21
Chapter 1 Introduction
What is SP5220?
SP5220 is a centrally managed solution for Micronet VoIP device. When you upgrade the
firmware of Micronet VoIP device, SP5220 can provide you an easy way to set up your
Micronet VoIP device without reconfiguring the device’s setting.
SP5220 includes the following components:
EMSClient: You can use EMSClient to upload your configuration or latest firmware.
EMS Server: It gets resource from the EMSClient, such as configuration and firmware. It
also collects and stores logs, helps you control and manage your VoIP environment.
How does SP5220 work?
The same as FTP server, EMSClient uploads the Firmware and Configuration to EMS
Server. Upgrading your VoIP device without SP5220 function, the configuration will become
the default value, so you have to reconfigure it. But with SP5220 function, you only need to
configure your VoIP device’s EMS Server IP address. After a particular time or rebooting, it
will try to look for the EMS Server and update the latest firmware or configuration. When
EMSClient connects to EMS Server, UDP (User Datagram Protocol) start. The UDP
automatically send EMSClient and C.P.E ‘s actions to EMSClient from EMS Server. User
can easily master the C.P.E ‘s latest status.
Chapter 2 Features
1. Communicate with EMSClient for uploading C.P.E’s configuration and firmware to EMS
Server.
2. Accept C.P.E’s connection request, and allow the C.P.E download the configuration (by
MAC address as the identification) and firmware (by firmware version).
3. Support connection log, upload / download log.
4. Support states
a. Total connections
b. Current connections
c. Files downloaded
d. Files uploaded
e. Failed downloaded
f. Failed uploaded
5. Support remote upgrade EMS Server program.
6. Support dual network interface for public and private network.
7. Support maximum connections limitation.
Chapter 3 Configuration
Environment
EMS Server’s system environment
SP5220
Intel Pentium(R) 4 CPU 2.4GHz
1024MB RAM
512MB ROM
Microsoft Windows XP Embedded
Appearance Description
Front Panel:
Functions:
1: Power LED
2: H/D LCD
3: System Status LED
4: LCD Panel
5: LCD Touch Panel
6: Power Switch
Rear Panel:
Functions:
1: Power Supply
2: Fan
3: Console port
4: Keyboard/Mouse
5: SIP Service Ethernet port
6: Management Ethernet port
7: VGA
8: USB (not used)
Monitoring connecting status
EMS Server will keep track of some events, click [CPE Status], the entries will appear in
right window, which are event information related to EMS Server. You can use this
information to verify that the server is running smoothly and to confirm the connection
between server and client
Total Connections: All of the connection numbers.
Current Online: The current online numbers.
Total files downloaded: All of the numbers were downloaded.
Total files uploaded: All of the numbers were uploaded.
Operation
User can change user account form EMS Server. Select [EMS-Client Account], enter the
new account and password, Press [OK] to save your configuration, press [Cancel] to
cancel it.
Default setting is:
UserName: admin
Password: 1234
Chapter 4 Installing EMSClient
System Requirements
These are the minimum system requirements for PC to install “EMSClient”:
400MHz Pentium II
64MB RAM
10MB Hard Disk Space
Windows 98 or later
Installing EMSClient
To install the Installation Wizard, follow the steps 1~6 on this guide.
STEP 1. OPEN THE [EMSCLIENT] FOLDER TO BEGIN INSTALLATION
Step 2. Double-click [Setup.exe] to begin installation.
Step 3. The Welcome Screen will appear, click [Next] to continue.
Step 4. Choose Destination Location: select the directory that you want to install, and
click [next] to continue.
Step 5. Select Program Folder: type the program name, and click [next] to continue.
Step 6. After installation, the wizard will inform you the installation is successful. Click
[Finish] to exit the installer.
Uninstall EMSClient
Step 1. Click [Start] on the Windows taskbar.
Step 2. Open [Settings] and click [Control Panel] to enter it.
Step 3. Double-click [Add/Remove Programs]
Step 4. Select [SP5220 client] in the list of programs.
Step 5. Click [Add/Remove]
Chapter 5 Configuring EMSClient
Start EMSClient by double-click [EMSClient] icon on the windows desktop. User can
upload files and manage their Home Directory by using EMSClient.
EMS Server Setting
There are three tab-pages for EMS Server Setting: EMSServer Setting, EMS-Client
Account and Gateway Account. When user first uses EMSClient, you must to select EMS
Server Setting to connect between server and client.
EMS Server Setting
There are several parameters for EMSClient to configure the EMS Server. The followings
are the detail of those parameters. When input complete, user can press Test Connection
to test connection between server and client. If you don’t want to attempt to connection, you
can press Apply change to finish modified.
1. EMS Server IP: Enter the IP address of EMS Server.
2. EMS Server port: Enter the FTP port number in this field.
3. User Name: Input the user account, which you got from EMS Server.
4. Password: Input the user password, which you got from EMS Server.
5. After configuring the EMS Server Setting, click [Test connection] to test connection.
6. If connect EMS Server successfully, message will tell user connect successfully.
7. If connect EMS Server unsuccessfully, message will tell user can’t connect EMS Server.
8. If user changes EMS Server setting without tries to connect EMS Server, click [Apply
change] to save EMS Server setting.
Reset And Restart EMS Server
User can remotely reset EMS Server or restart EMS Server Os system from SP5220 Client.
Please click [Reset EMS Server] to reset EMS Server or click [Restart EMS Server] to
restart EMS Server Os system.
Upgrade EMS Server
User can remotely upgrade EMS Server program form EMSClient. The followings are the
detail of those steps.
1. Choose the upgrade bin file, than clicks [open]
2. Clicks [OK] to complete EMS Server program upgrade.
EMSClient Account
User can change EMS Server’s login users name and password for EMSClient’s
connection, select this page and begin to change
1. New Name: Enter the new user name of EMS Server.
2. New Password: Enter the new password of EMS Server.
3. Confirm Password: Enter the new password again to confirm password of EMS Server.
4. After changed user’s name and password, click [OK] to decide, click [Cancel] to cancel
it.
Gateway Account
User can change EMS Server’s login users name and password for C.P.E connection,
select this page than begin to change.
1. New Name: Enter the new user name of C.P.E.
2. New Password: Enter the new password of C.P.E.
3. Confirm Password: Enter the new password again to confirm password of C.P.E.
4. Max connection: Enter the maximum connections limitation.
4. AFTER CHANGED USER’S NAME AND PASSWORD, CLICK [OK] TO DECIDE, CLICK [CANCEL] TO
CANCEL IT.
Note:
EMS Server initial user name is [admin], password is [1234]
The maximum connections are [10].
Firmware Setting
User can use EMSClient to upload firmware’s files. When user wants to upload Firmware
Setting, please follow the steps bellow to upload Firmware Setting.
1. Press [New] to add a new Firmware Setting.
2. Input the firmware name in the Firmware field: The firmware name is the current
firmware name of your VoIP device.
3. Input the firmware path in the File Path field: The file path indicates the firmware path
that you want to upgrade.
Note:
After rebooting or the SP5220 time is out, the VoIP device will try to discover
the EMS Server. While the VoIP device finds out the EMS Server, it will
compare the firmware name with EMS Server, which you import in Firmware.
Then upgrade the latest version that you import in File Path.
4. Press [Save] to save your configuration, and then the firmware name will appear in the
Firmware list.
5. Choose the firmware name then click [Upload] to upload your Firmware Setting.
6. If you want to remove the firmware from Firmware list, click [Delete].
Note:
When user uploads firmware, EMSClient automatically uploads all of the MAC
address in [Configuration Setting] too. It can assure the C.P.E’s firmware
version will be the last.
Configuration Setting [SIP]
After rebooting or the SP5220 time is out, the VoIP device will try to discover the EMS
Server. While the VoIP device finds out the MAC address from EMS Server, which you
import in MAC field. The VoIP device will compare the setting with EMS Server then update
it.
1. Press [New] to add a new Configuration Setting
2. Input MAC address in MAC field.
Note:
User can find MAC address on a label at the bottom of device with format
“0001a8xxxxxx”
3. Configuring your configuration.
4. Press [Apply] to save your configuration, and then the MAC address will appear in the
MAC Address list.
5. User can select only one MAC address or press [Ctrl] to select plural MAC address. If
you want to select all MAC address, click [Select All] to select all of MAC address then
click [Upload] to upload your Configuration Setting.
6. If you want to remove the Mac address from MAC Address list, click [Delete].
Note:
User must to choice PROXY or PEER 2 PEER mode. User can input
Proxy/GK IP when selected PROXY mode. However user can’t input
Proxy/GK IP when selected PEER 2 PEER modes.
Configuration Setting [H323]
After rebooting or the SP5220 time is out, the VoIP device will try to discover the EMS
Server. While the VoIP device finds out the MAC address from EMS Server, which you
import in MAC field. The VoIP device will compare the setting with EMS Server then update
it.
1. Press [New] to add a new Configuration Setting
2. Input MAC address in MAC field.
3. Configuring your configuration.
4. Press [Apply] to save your configuration, and then the MAC address will appear in the
MAC Address list.
Note:
User must to choice GETKEEP or PEER 2 PEER mode. User can input Gk IP
when selected GETKEEP mode. However user can’t input Gk IP when
selected PEER 2 PEER modes.
5. User can select only one MAC address or press [Ctrl] to select plural MAC address. If
you want to select all MAC address, click [Select All] to select all of MAC address then
click [Upload] to upload your Configuration Setting.
6. If you want to remove the Mac address from MAC Address list, click [Delete].
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

MicroNet SP5220 User manual

Type
User manual

MicroNet SP5220 is a centrally managed solution for Micronet VoIP devices, allowing easy setup and configuration without the need for reconfiguring device settings. It includes EMSClient for uploading configurations and firmware, and EMS Server for collecting logs and controlling the VoIP environment. SP5220 communicates with EMSClient to upload CPE configurations and firmware to the EMS Server, accepts CPE connection requests, and supports various logs and statistics.

Ask a question and I''ll find the answer in the document