- 3 -
suitability or not.
3. Insert the top of the DIN-Rail into the slot just below the
stiff metal spring.
4. The DIN-Rail attachment unit will snap into place as shown
below.
Wiring Requirements
Cable laying need to meet the following requirements,
1. It is needed to check whether the type, quantity and
specification of cable match the requirement before cable
laying;
2. It is needed to check the cable is damaged or not, factory
records and quality assurance booklet before cable laying;
3. The required cable specification, quantity, direction and
laying position need to match construction requirements, and
cable length depends on actual position;
4. All the cable cannot have break-down and terminal in the
middle;
5. Cables should be straight in the hallways and turning;
6. Cable should be straight in the groove, and cannot beyond the
groove in case of holding back the inlet and outlet holes.
Cables should be banded and fixed when they are out of the
groove;
7. User cable should be separated from the power lines. Cables,
power lines and grounding lines cannot be overlapped and
mixed when they are in the same groove road. When cable is
too long, it cannot hold down other cable, but structure in the
middle of alignment rack;
8. Pigtail cannot be tied and swerved as less as possible.
Swerving radius cannot be too small (small swerving causes
terrible loss of link). Its banding should be moderate, not too
tight, and should be separated from other cables;
9. It should have corresponding simple signal at both sides of the
cable for maintaining.
Specification
Technology
Standard: IEEE802.3, IEEE802.3u, IEEE802.3x, IEEE802.3ab
Flow control: IEEE802.3x, back pressure control
Exchange attribute
100M forward speed: 148810pps
1000M forward speed: 1488100pps
Transmit mode: store and forward
System exchange bandwidth: 16Gbps
MAC address table: 8K
Memory: 1Mbit
Interface
Gigabit Ethernet port: 10Base-T/100Base-TX/1000 Base-TX auto
speed control
Transfer distance
Twisted cable: 100M (standard CAT5/CAT5e cable)
LED indicator
Interface indicator: Link/ACT (G1~G8)
Power supply indicator: PWR
Power supply
Input Voltage: 24VDC (12~48VDC)
Type of input: 3 bits 7.62mm terminal block
Support non-polarity
Overload current protect: 4.0A
Consumption
No-load power consumption: 0.82W@24VDC
Full-load power consumption: 3.65W@24VDC
Working environment
Working temperature: -25 70
Storage temperature: -40 85
Relative Humidity: 5%~95 %( no condensation)
Mechanical Structure
Shell: IP40 protect grade, metal shell
Installation: DIN-Rail
Weight: 0.62kg
Size (W×H×D): 53mm×138mm×110mm
Industry Standard
EMI: FCC Part 15, CISPR (EN55022) class A
EMS: EN61000-4-2 (ESD), Level 2
EN61000-4-3 (RS), Level 2
EN61000-4-4 (EFT), Level 2
EN61000-4-5 (Surge), Level 2
EN61000-4-6 (CS), Level 2
EN61000-4-8, Level 2
Shock: IEC 60068-2-27
Free fall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Certification
CE, FCC, RoHS, UL508 (Pending)
Warranty: 3 years