SMAR ISD600P is an auxiliary module for the CD600 / CD600 Plus Multi-loop Digital Controller, which converts the open-collector digital outputs into relays outputs. This increases the rating of outputs, allowing the connections of higher loads. It has 2 groups of 4 outputs SPST NO (Normally Open) with a maximum current per output of 5A and a maximum total current of 10A per group. The power supply is 24 Vdc. The device is easy to install and can be used in a variety of applications, such as industrial automation, process control, and manufacturing.

SMAR ISD600P is an auxiliary module for the CD600 / CD600 Plus Multi-loop Digital Controller, which converts the open-collector digital outputs into relays outputs. This increases the rating of outputs, allowing the connections of higher loads. It has 2 groups of 4 outputs SPST NO (Normally Open) with a maximum current per output of 5A and a maximum total current of 10A per group. The power supply is 24 Vdc. The device is easy to install and can be used in a variety of applications, such as industrial automation, process control, and manufacturing.

DIGITAL OUTPUT ISOLATOR
FOR CD600 / CD600 Plus
ISD600P
MAR / 05
VERSION 01
FOUNDATION
I SD600PME
TECHNICAL INFORMATIO
N
web: www.smar.com/contactus.asp
www.smar.com
Specifications and information are subject to change without notice.
Up-to-date address information is available on our website.
sma
r
Digital Output Isolator for CD600 / CD600 Plus
3
DIGITAL OUTPUT ISOLATOR FOR CD600
/ CD600 Plus
The ISD600P Digital Output Isolator is an auxiliary module for the CD600 / CD600 Plus Multi-loop
Digital Controller, which converts the open-collector digital outputs into relays outputs. This
increases the rating of outputs, allowing the connections of higher loads.
Technical Characteristics
POWER SUPPLY
24 Vdc ± 10%
MAXIMUM CONSUMPTION
170 mA
OUTPUTS
2 groups of 4 outputs SPST NO (Normally Open)
Max. Current per Output 5A
Max. Total Current 10A per group
CD600 / CD600 Plus
Power Supply
ISD600P
VEXT
SD
GND D
Digital Ground
24 Vdc
-+ 24V
SD1
1B
2B
3B
4B
5B
6B
7B
8B
9B
10B
SD2
10A
9A
GND
SD8
4A
1A
2A
3A
SD3
5A
6A
7A
8A
SD4
SD5
SD6
SD7
Figure 1 – Connection Diagram (CD600 / CD600 Plus / ISD600P)
Digital Output Isolator for CD600 / CD600 Plus
4
Figure 2 – Terminal Block Figure 3 - Dimensions
Appendix A
A.1
SRF – Service Request Form
ISD600 – Digital Output Isolator for CD600 / CD600 Plus Proposal Nº:
COMPANY INFORMATION
Company:
_____________________________________________________________________________________________________
Unit: ________________________________________________________________________________________________________
Invoice: _______________________________________________________________________________________________________
COMMERCIAL CONTACT
Full Name:
____________________________________________________________________________________________________
Phone: _________ _________________________ _________ _________________________ Fax: _______________________
E-mail: _______________________________________________________________________________________________________
TECHNICAL CONTACT
Full Name: ________________________________________________________________________________________________
Phone: _________ _________________________ _________ _________________________ Extension: ____________________
E-mail: _______________________________________________________________________________________________________
EQUIPMENT DATA
Model:
______________________________________________________________________________________________________
Serial Number: ________________________________________________________________________________________________
PROCESS DATA
Process Type (Ex. boiler control): __________________________________________________________________________
Operation Time: ____________________________________________________________________________________________
Failure Date: __________________________________________________________________________________________________
FAILURE DESCRIPTON
(Please, describe the failure. Can the error be reproduced? Is it repetitive?)
______________________________________________________________________________________________________________
______________________________________________________________________________________________________________
______________________________________________________________________________________________________________
______________________________________________________________________________________________________________
NOTES
______________________________________________________________________________________________________________
______________________________________________________________________________________________________________
______________________________________________________________________________________________________________
______________________________________________________________________________________________________________
USER INFORMATION
Company: _____________________________________________________________________________________________________
Contact: _______________________________________________________________________________________________________
Section: _______________________________________________________________________________________________________
Title: ________________________________________________ Signature:_______________________________________________
Phone: _________ _________________________ _________ _________________________ Extension: ___________________
E-mail: ________________________________________________________________________ Date: ______/ ______/ _________
For warranty or non-warranty repair, please contact your representative.
Further information about address and contacts can be found on www.smar.com/contactus.asp
Digital Output Isolator for CD600 / CD600 Plus
A.2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

SMAR ISD600P User manual

Type
User manual

SMAR ISD600P is an auxiliary module for the CD600 / CD600 Plus Multi-loop Digital Controller, which converts the open-collector digital outputs into relays outputs. This increases the rating of outputs, allowing the connections of higher loads. It has 2 groups of 4 outputs SPST NO (Normally Open) with a maximum current per output of 5A and a maximum total current of 10A per group. The power supply is 24 Vdc. The device is easy to install and can be used in a variety of applications, such as industrial automation, process control, and manufacturing.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI