Benchmark BMK 750

Aerco Benchmark BMK 750, Benchmark BMK 1000, BMK 1500, BMK 2000, BMK 2500, BMK 3000, BMK 5000, BMK 6000, BMK Series Installation And Start-Up Manual

  • Hello! I am an AI chatbot trained to assist you with the Aerco Benchmark BMK 750 Installation And Start-Up Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Inst
Be
n
Wi
t
Natu
Mod
u
Mod
e
Other
d
OMM
OMM
OMM
TAG-
TAG-
TAG-
TAG-
Applie
s
G-19
-
N-19
-
OMM-13
6
allation
n
ch
m
t
h Ed
ral Gas,
u
lating
&
e
ls 750
t
d
ocuments f
o
-0137, GF-2
1
-0138, GF-2
1
-0139, GF-2
1
0019, GF-20
7
0022, GF-20
5
0047, GF-20
3
0048, GF-20
6
s
to serial n
u
0300 and ab
-
0100 and ab
o
6
_D • GF-210
and St
m
ark
®
ge C
o
Propan
e
&
Conde
n
t
hrough
6
o
r this prod
u
1
1 Operation
-
1
2 Reference
1
3 Edge Con
t
7
0 Boiler Ap
p
5
0 Vent-Co
m
3
0 Benchma
r
6
0 Benchma
r
u
mbers:
ove – BMK 7
o
ve – BMK 5
0
7/16/2019
artup
M
Plati
n
o
ntro
l
e
Gas a
n
n
sing B
o
6
000
u
ct include:
-
Service Man
Manual
t
roller Manua
p
lication Guid
e
bustion Air
G
r
k Gas Guide
r
k Power Gui
d
50 – 3000
0
00 & 6000
M
anual
n
um
B
l
ler
n
d Dual
o
ilers
ual
l
e
G
uide
d
e
B
oile
r
Fuel
r
s
Bench
m
CONTE
N
OMM-13
6
Tabl
e
FORE
W
SECTIO
N
1.1 WA
R
1.2 EME
1.3 PRO
1.4 IMP
O
SECTIO
N
2.1 INT
R
2.2 REC
2.3 UNP
A
2.4 SITE
2.4.1I
n
2.4.2S
e
2.5 LIFT
I
2.5.1B
M
2.5.2B
M
2.5.3B
M
2.6 SUP
P
2.6.1B
M
2.6.2B
M
2.6.3B
M
2.6.4D
2.7 PRE
S
2.8 CON
2.9 GAS
2.9.1G
a
2.9.2E
x
2.9.3
M
2.10 AC
2.10.1
E
2.10.2
P
2.10.3
E
2.11 FIE
2.11.1I
2.12 FL
U
2.12.1
M
2.13 CO
M
2.13.1
D
2.14 BS
T
SECTIO
N
3.1 INT
R
3.1.1C
o
3.1.2C
o
m
ark Plat
i
N
TS
6_
D • GF-210
e
ofC
o
W
ORD.....
N
1:
SA
F
R
NINGS &
C
RGENCY S
LONGED S
O
RTANT –
F
N
2:
INS
T
R
ODUCTIO
N
EIVING TH
E
A
CKING .....
PREPARA
T
n
stallationCl
e
e
ttingtheUn
i
I
NG PROVI
S
M
K75010
0
M
K15003
0
M
K500060
0
P
LY AND R
M
K75010
0
M
K15003
0
M
K50006
0
u
alInletRet
u
S
SURE RE
L
DENSATE
D
SUPPLY P
I
a
sSupplySp
e
x
ternalGasS
u
M
anualGasS
h
ELECTRIC
A
E
lectricalPo
w
P
owerPanel
E
lectricalPo
w
LD CONTR
O
/OBoardCo
n
U
E GAS VE
N
M
ASSACHUS
E
M
BUSTION
D
UCTEDCO
M
T
SEQUEN
C
N
3:
ON
A
R
ODUCTIO
N
o
nnectingth
e
o
nfirmingth
e
i
num wit
h
7/16/2019
o
ntent
s
...............
.
F
ETYPREC
A
C
AUTIONS ..
HUTDOWN
HUTDOWN
F
OR MASS
A
T
ALLATIO
N
N
.................
E
UNIT ........
...................
T
ION ..........
e
arances.......
i
t..................
S
IONS ........
0
0LiftingPro
v
0
00LiftingPr
o
0
0LiftingPro
v
ETURN PI
P
0
0Supplyan
d
0
00Supplya
n
0
00Supplya
n
u
rnPiping.....
L
IEF VALV
E
D
RAIN
A
N
D
I
PING .........
e
cifications...
u
pplyRegula
t
h
utoffValve..
A
L POWER
w
erRequire
m
L
ocations.....
w
erPanelInt
e
O
L WIRING
n
nections.....
N
T INSTAL
L
E
TTSINSTALL
AIR ............
M
BUSTIONAI
R
C
ING ISOL
A
A
ERSETU
P
N
.................
e
EthernetC
a
e
EthernetCo
h
Edge C
o
Technical S
u
s
.
...............
A
UTIONS.
..................
.
..................
.
..................
.
A
CHUSETT
S
N
.............
..................
.
..................
.
..................
.
..................
.
....................
.
....................
.
..................
.
v
isions.........
.
o
visions.......
.
v
isions..........
.
P
ING ...........
.
d
ReturnPipi
n
n
dReturnPip
n
dReturnPip
....................
.
E
INSTALLA
D
PIPING ....
.
..................
.
....................
.
t
or...............
.
....................
.
WIRING ....
.
m
ents............
.
....................
.
e
rnalCompo
n
– I/O BOA
R
....................
.
L
ATION ......
.
ATIONS.......
.
..................
.
R
..................
.
A
TION VAL
V
P
..............
..................
.
a
ble..............
.
nnection.....
.
o
ntroller: I
u
pport (800) 5
...............
.
...............
.
.
..................
.
..................
.
..................
S
INSTALL
A
...............
.
.
..................
.
..................
.
..................
.
..................
.
....................
.
.
....................
.
.
..................
.
....................
.
.
....................
.
.
....................
.
.
..................
n
g.................
.
ing...............
.
ing...............
.
.
....................
.
TION .........
.
..................
.
..................
.
....................
.
.
....................
.
.
....................
.
.
..................
.
....................
.
.
....................
.
n
ents............
.
R
D ..............
.
....................
.
.
..................
.
....................
.
.
..................
.
....................
.
V
E INST
A
LL
A
...............
.
.
..................
.
....................
.
.
....................
.
nstallatio
5
26-0288 Mon
-
...............
.
...............
.
...................
...................
...................
A
TIONS ......
...............
.
...................
...................
...................
...................
.....................
.....................
...................
.....................
.....................
.....................
...................
.....................
.....................
.....................
.....................
...................
...................
...................
.....................
.....................
.....................
...................
.....................
.....................
.....................
...................
.....................
...................
.....................
...................
.....................
A
TION........
...............
.
...................
.....................
.....................
o
n Manual
-
Fri, 8 am - 5 pm
.
...............
.
...............
..................
.
..................
.
..................
.
..................
.
.
...............
..................
.
..................
.
..................
.
..................
.
....................
.
....................
.
..................
.
....................
.
....................
.
....................
.
..................
.
....................
.
....................
.
....................
.
....................
.
..................
.
..................
.
..................
.
....................
.
....................
.
....................
.
..................
.
....................
.
....................
.
....................
.
..................
.
....................
.
..................
.
....................
.
..................
.
....................
.
..................
.
.
...............
..................
.
....................
.
....................
.
EST Page
2
...............
...............
.
..................
.
..................
.
..................
.
..................
...............
.
..................
.
..................
.
..................
.
..................
.
....................
.
.
....................
.
.
..................
.
....................
.
.
....................
.
.
....................
.
.
..................
.
....................
.
.
....................
.
.
....................
.
.
....................
.
.
..................
.
..................
.
..................
.
....................
.
.
....................
.
.
....................
.
.
..................
.
....................
.
.
....................
.
.
....................
.
.
..................
.
....................
.
.
..................
.
....................
.
.
..................
.
....................
.
.
..................
...............
.
..................
.
....................
.
.
....................
.
2
of 54
.....5
.....9
...... 9
.... 10
.... 10
.... 11
...13
.... 13
.... 13
.... 13
.... 14
.....14
.....17
.... 19
.....19
.....20
.....20
.... 21
.....21
.....22
.....23
.....23
.... 24
.... 25
.... 27
.....27
.....27
.....30
.... 30
.....30
.....30
.....32
.... 33
.....34
.... 38
.....38
.... 39
.....39
.... 40
...43
.... 43
.....43
.....44
Bench
m
CONTE
N
OMM-13
6
3.1.3C
o
APPEN
D
m
ark Plat
i
N
TS
6_
D • GF-210
o
nfirmEther
n
D
IXA:
DI
M
i
num wit
h
7/16/2019
n
etDHCPCo
n
M
ENSION
A
h
Edge C
o
Technical S
u
n
figuration...
.
A
LANDCL
E
o
ntroller: I
u
pport (800) 5
.
....................
.
E
ARANCE
D
nstallatio
5
26-0288 Mon
-
.....................
D
RAWING
o
n Manual
-
Fri, 8 am - 5 pm
....................
.
S.............
EST Page
3
.
....................
.
...............
3
of 54
.....45
...47
Bench
m
CONTE
N
OMM-13
6
m
ark Plat
i
N
TS
6_
D • GF-210
i
num wit
h
7/16/2019
h
Edge C
o
Technical S
u
(This page
o
ntroller: I
u
pport (800) 5
intentionall
y
nstallatio
5
26-0288 Mon
-
y
blank)
o
n Manual
-
Fri, 8 am - 5 pm
EST Page
4
4
of 54
Bench
m
FORWA
R
OMM-13
6
FOR
The AE
R
modulati
of today
'
hydronic
fluctuati
n
are ideal
IMPO
R
Unless
o
Platinum
The Be
n
measur
e
Benc
h
MODE
L
BMK75
0
BMK10
0
BMK15
0
BMK20
0
BMK25
0
BMK30
0
BMK50
0
BMK60
0
The out
p
tempera
t
When in
s
and 500
0
Manage
m
the Bay
A
Whether
flexibility
positive
p
the follo
w
R
o
D
u
These b
o
addition,
(excludi
n
m
ark Plat
i
R
D
6_
D • GF-210
EWO
R
R
CO Bench
m
n
g and con
d
'
s energy a
system, t
h
n
g system l
o
ly suited for
R
TANT!
o
therwise s
p
Series of b
o
n
chmark
m
ments appl
y
markPlat
L
I
MIN
0
50,000(
1
0
0 50,000(
1
0
0 75,000(
2
0
0 100,000
0
0 167,000
0
0 200,000
0
0 400,000
0
0 400,000
p
ut of the b
o
t
ure.
s
talled and
0
& 6000 co
m
m
ent Distri
c
A
rea Air Q
u
used in sin
g
with minim
p
ressure ap
w
ing vent co
o
om Comb
u
o Vertic
a
o Horiz
o
u
cted Com
b
o Vertic
a
o Horiz
o
o
ilers are ca
the BMK
7
n
g the state
o
i
num wit
h
7/16/2019
R
D
m
ark (BMK
)
d
ensing unit
s
nd environ
m
h
e Bench
m
o
ads. Thes
e
modern lo
w
p
ecified all
d
o
iler.
m
odels ope
r
y
to both na
t
inumBoil
e
I
NPUTRAN
G
IMUM
1
4.6kW)
1
4.6kW)
2
2kW)
(29.3kW)
(48.9kW)
(58.6kW)
(117kW)
(117kW)
o
iler is a fu
n
operated in
m
ply with th
c
t (SCAQM
u
ality Mana
g
g
ular or mo
d
um installat
pliances. Si
nfigurations
u
stion Air:
a
l Discharg
e
o
ntal Discha
r
b
ustion Air:
a
l Discharg
e
o
ntal Discha
r
pable of bei
7
50 & 1000
o
f Massach
u
h
Edge C
o
Technical S
u
)
750 throu
g
s
. They rep
r
m
ental con
c
m
ark's mod
u
e
BMK mod
e
w
temperatu
r
d
escriptions
r
ate within
t
ural gas an
d
e
rIntake
a
G
E(BTU/HR
MAXI
M
750,000(22
0
1,000,000(2
9
1,500,000(4
4
2,000,000(5
8
2,500,000(7
3
3,000,000(8
7
5,000,000(1
4
6,000,000(1
7
n
ction of th
e
accordanc
e
e NO
x
emis
s
D), Rule 11
g
ement Di
s
d
ular arrang
i
on space r
e
ngle and/or
:
e
r
ge
e
r
ge
ng vented u
models ar
e
u
setts) .
o
ntroller: I
u
pport (800) 5
g
h 6000 nat
u
r
esent a tru
e
c
erns. Desi
g
u
lating cap
a
e
ls provide
r
e, as well a
s
provided in
the input
d
propane
m
a
ndOutpu
.)
M
UM
0
kW)
4
9
3kW)
4
4
0kW)
6
8
6kW)
8
3
2kW)
1
7
9kW)
1
4
65kW)
3
7
58kW)
3
e
unit’s firin
e
with this I
n
s
ion standa
r
46.2. In ad
d
s
trict regul
a
e
ments, the
e
quirement
s
multiple br
e
tilizing Poly
p
e
also appr
o
nstallatio
5
26-0288 Mon
-
u
ral gas an
d
e
industry a
d
g
ned for ap
p
a
bility relat
e
extremely
h
s
, conventio
this docu
m
and outpu
t
m
odels, unle
s
tRanges
OUTP
U
MINIMU
M
4
7,750(14.0
k
4
8,300(14.2
k
6
4,500(18.9
k
8
6,000(25.2
k
1
44,000(42.
2
1
74,000(51.
0
3
48,000(102
3
48,000(102
g rate (valv
n
struction
M
r
ds outlined
d
ition, the B
M
a
tion 9, Rul
e
e
BMK boile
r
s
. These bo
e
eched unit
s
p
ropylene a
n
o
ved for PV
o
n Manual
-
Fri, 8 am - 5 pm
d
propane f
u
d
vance that
p
lication in
e
s energy
h
igh efficien
c
nal heating
m
ent apply t
o
t ranges l
i
s
s otherwis
e
U
TRANGE(
M
k
W) 716,
2
k
W) 968,
0
k
W) 1,39
5
k
W) 1,86
0
2
kW) 2,39
5
0
kW) 2,87
4
kW) 4,75
0
kW) 5,70
0
v
e position)
M
anual, the
B
in: South
C
M
K 2500 –
6
e
7.
r
s offer the
m
ilers are C
a
s
are capab
n
d AL29-4C
C and CP
V
EST Page
5
u
eled boile
r
meets the
n
any closed
input direc
t
c
y operatio
n
systems.
o
the Benc
h
i
sted belo
w
e
specified.
BTU/HR.)
MAXIMUM
2
50(210kW)
0
00(284kW)
5
,000(409k
W
0
,000(545k
W
5
,000(702k
W
4
,000(842k
W
0
,000(1392k
0
,000(1670k
and return
w
B
MK 750 –
C
oast Air Q
u
6
000 compl
y
m
aximum v
e
a
tegory II a
n
le of operat
i
vent syste
m
V
C, vent sy
s
5
of 54
r
s are
n
eeds
loop
t
ly to
n
and
h
mark
w
. All
W
)
W
)
W
)
W
)
W)
W)
w
ater
2000
u
ality
y
with
e
nting
n
d IV,
i
on in
m
s. In
s
tems
Bench
m
FORWA
R
OMM-13
6
The Ben
offering
t
AERCO
T
TER
M
A (Amp)
ACS
ADDR
AGND
ALRM
ANSI
ASME
AUX
BAS
Baud R
a
BMK (B
e
BMS or
BLDG (
B
BST
BTU
BTU/HR
CCS
C-More
C
CFH
CO
COMM (
C
Cal.
CNTL
CPU
DBB
DIP
ECU
EMS
FM
GF-xxxx
m
ark Plat
i
R
D
6_
D • GF-210
chmark's a
d
t
he most effi
T
echnical
T
M
INOLOGY
te
e
nchmark)
BMS II
B
ldg)
C
ontrolle
r
C
omm)
i
num wit
h
7/16/2019
d
vanced ele
cient opera
t
T
erminolog
y
A
mper
A
ERC
O
A
ddre
s
A
nalo
g
Alarm
A
meri
c
A
meri
c
A
uxilia
Buildin
(see b
e
Symb
o
(signal
secon
d
A
ERC
O
A
ERC
O
Buildin
A
ERC
O
British
heat r
e
BTUs
p
Combi
n
A
con
t
Bench
m
Cubic
F
Carbo
n
Comm
Calibr
a
Contro
Centra
Doubl
e
Valves
Dual I
n
Electr
o
Energ
y
Factor
y
Gas Fi
h
Edge C
o
Technical S
u
ctronics ar
e
t
ing method
s
y
Meaning
s
e
O
Control S
y
s
s
g
Ground
c
an National
c
an Society
o
ry
g Automati
o
e
low)
o
l rate, or
s
ing events)
d
, unless ea
c
O
’s Benchm
O
Boiler Ma
n
g
O
on-board
Thermal U
n
e
quired to ra
p
er Hou
r
(1
n
ation Cont
r
t
rol system
m
ark, Innov
a
F
eet per Ho
u
n
Monoxide
unication
a
tion
l
l Processin
g
e
Block and
(SSOVs) a
n
n
-Line Pack
a
o
nic Control
y
Managem
e
y
Mutual. U
s
red (an AE
R
o
ntroller: I
u
pport (800) 5
e
available i
n
s
and energ
y
s
M
y
stem, AER
C
Standards
o
f Mechani
c
o
n System,
o
s
imply the
transmitted
c
h symbol i
s
ark series b
n
agement
S
Boiler Sequ
e
n
it. A unit
o
ise 1 pound
BTU/hr = 0.
2
r
ol System
developed
a
tion and K
C
ur
(1 CFH =
g
Unit
Bleed, a g
n
d a soleno
i
a
ge, a type
o
Unit (O
2
se
n
e
nt System;
s
ed to defin
e
R
CO docum
e
nstallatio
5
26-0288 Mon
-
n
several s
e
y
managem
e
M
EANING
C
O’s boiler
Institute,
c
al Engineer
s
often used
number of
per second
s
1 bit long.
b
oilers
S
ystems
e
ncing Tec
h
o
f energy a
(0.45 kg) o
f
2
9 W)
by AERCO
C
1000 Seri
e
0.028 m
3
/h
r
g
as trains c
o
i
d operated
v
o
f switch
n
sor)
often used
i
e
boiler gas
t
e
nt numberi
o
n Manual
-
Fri, 8 am - 5 pm
e
lectable m
o
e
nt system i
manageme
n
r
s
interchange
distinct sy
. It is not e
q
h
nology
pproximatel
y
f
water 1°F
(
and curre
n
e
s product li
n
r
)
o
ntaining 2
vent valve.
i
nterchange
a
trains.
ng system)
EST Page
6
o
des of ope
r
ntegration.
n
t systems
ably with E
M
mbol chan
g
q
ual to bits
p
y
equal to
t
(
0.55 °C)
n
tly used in
n
es.
Safety Shu
t
a
bly with B
A
6
of 54
r
ation
M
S
g
es
p
er
t
he
all
t
off
A
S
Bench
m
FORWA
R
OMM-13
6
AERCO
T
TER
M
GND
HDR
Hex
HP
HX
Hz
I.D.
IGN
IGST Bo
INTLK (I
N
I/O
I/O Box
IP
ISO
Lbs.
LED
LN
MA (mA
)
MAX (M
a
MBH
MIN (Mi
n
Modbus
®
NC (N.C
NO (N.O
NO
x
NPT
O
2
O.D.
OMM, O
&
onAER
PCB
PMC Bo
a
P/N
POC
PPM
PSI
m
ark Plat
i
R
D
6_
D • GF-210
T
echnical
T
M
INOLOGY
ard
N
TL’K)
)
a
x)
n
)
®
.)
.)
&
M
a
rd
i
num wit
h
7/16/2019
T
erminolog
y
Groun
d
Heade
Hexad
e
Horse
Heat
E
Hertz (
Inside
Ignitio
n
Ignitio
n
Interlo
c
Input/
O
Input/
O
Intern
e
Intern
a
Pound
s
Light
E
Low N
i
Millia
m
Maxim
1000
B
Minim
u
A
seri
a
Modic
o
Norma
Norma
Nitrog
e
Nation
a
Oxyge
n
Outsid
e
Opera
t
A
ERC
O
Printe
d
Primar
y
Contro
Part N
u
Proof
o
Parts
p
Pound
s
h
Edge C
o
Technical S
u
y
Meaning
s
d
r
e
cimal Num
Powe
r
E
xchange
r
Cycles Per
S
Diamete
r
n
n
/Stepper B
o
c
k
O
utput
O
utput (I/O)
B
e
t Protocol
a
tional Orga
n
s
(1 lb = 0.4
E
mitting Dio
d
i
trogen Oxid
m
pere (1 tho
u
um
B
TUs per H
o
u
m
a
l, hal
f
-dupl
e
o
n
lly Closed
lly Open
e
n Oxide
a
l Pipe Thr
e
n
e
Diamete
r
t
ion and Mai
O
’s on-line
r
d
Circuit Bo
a
y
Micro-Co
n
lle
r
u
mbe
r
o
f Closure
p
er Million
s
per Squar
e
o
ntroller: I
u
pport (800) 5
s
M
ber (0 – 9,
A
S
econd)
o
ard, contai
n
B
ox currentl
n
ization for
S
5 kg)
d
e
e
u
sand
th
of a
n
o
u
r
e
x data tran
e
ad
ntenance M
r
emote moni
a
rd
n
troller (P
M
e
Inch (1 P
S
nstallatio
5
26-0288 Mon
-
M
EANING
A
– F)
n
ed in the C
y used on
B
S
tandardiza
t
n
ampere)
n
smission p
r
M
anual
toring syste
M
C) board,
S
I = 6.89 kP
a
o
n Manual
-
Fri, 8 am - 5 pm
C
ontrolle
r
B
enchmark
b
tion
r
otocol dev
e
m
contained i
a
)
EST Page
7
b
oilers
e
loped by A
E
n the C-M
o
7
of 54
E
G
o
re
Bench
m
FORWA
R
OMM-13
6
AERCO
T
TER
M
PTP
P&T
ProtoNo
d
PVC
PWM
REF (R
e
RES.
RS232
(or EIA-
2
RS485
(or EIA-
4
RTN (Rt
n
SETPT (
SHLD (
S
SPDT
SSOV
TEMP (
T
Termina
t
Tip-N-T
e
UL
VAC
VDC
VFD
VPS
W
W.C.
µA
m
ark Plat
i
R
D
6_
D • GF-210
T
echnical
T
M
INOLOGY
d
e
f)
2
32)
4
85)
n
)
Setpt)
S
hld)
T
emp)
t
ing Resisto
r
e
ll
i
num wit
h
7/16/2019
T
erminolog
y
Point-t
o
Press
u
Hardw
a
Poly V
i
Pulse
W
Refere
Resisti
A
stan
on the
A
stan
d
on the
Return
Setpoi
n
Shield
Single
Safety
Temp
e
r
A
resi
s
in ord
e
comm
u
A
devi
c
A
busi
n
Volts,
A
Volts,
D
Variab
l
Valve
P
Watt
Water
Micro
a
h
Edge C
o
Technical S
u
y
Meaning
s
o
-Point (us
u
u
re and Tem
a
re interfac
e
i
nyl Chlorid
e
W
idth Modu
l
nce
ve
dard for se
r
RS232 Sta
n
d
ard for ser
RS485 Sta
n
n
t Tempera
t
Pole Doubl
e
Shut Off V
a
e
rature
s
tor placed
a
e
r to preve
n
u
nication
c
e that indic
a
n
ess that te
s
A
lternating
C
D
irect Curre
l
e Frequenc
P
roving Sys
t
Column, a
u
a
mp (1 milli
o
o
ntroller: I
u
pport (800) 5
s
M
u
ally over R
S
perature
e
between
B
e
, a commo
n
l
ation
r
ial, full-dupl
n
dard
ial, hal
f
-dup
n
dard
t
ure
e
Throw, a t
y
a
lve
a
t each end
n
t reflection
s
a
tes if a pa
c
s
ts and vali
d
C
urrent
nt
y Drive
t
em
u
nit of press
u
o
n
th
of an a
m
nstallatio
5
26-0288 Mon
-
M
EANING
S
232 netwo
r
B
AS and a b
o
n
synthetic
p
l
ex (FDX) t
r
lex (HDX) t
r
y
pe of switc
h
of a daisy-
c
s
that may
c
kage was ti
d
ates produ
c
u
re (1 W.C.
m
pere)
o
n Manual
-
Fri, 8 am - 5 pm
r
ks)
o
iler or wat
e
p
lastic
r
ansmission
r
ansmission
h
c
hain or mul
t
cause inva
pped durin
g
c
ts
= 249 Pa)
EST Page
8
e
r heate
r
of data ba
s
of data ba
s
t
i-drop netw
o
lid data in
t
g
shipping
8
of 54
s
ed
s
ed
o
rk
t
he
Bench
m
SECTIO
N
OMM-13
6
SEC
T
1.1
W
Installer
s
following
precauti
o
A
ERCO
in the a
b
for gas-
f
equipme
A
pplianc
which s
h
consulte
d
See se
c
Commo
n
IMPO
This In
s
conditi
o
referen
W
AR
N
Do
Flui
rel
e
de
c
Bef
o
inp
u
Th
e
mu
s
Ele
c
25
0
us
e
uni
t
A s
i
ins
t
acc
to
u
CAU
T
Ma
n
rin
s
DO
tec
h
m
ark Plat
i
N
1 – SAFE
T
6_
D • GF-210
T
ION
1
W
ARNI
N
s
and oper
a
warnings
a
o
ns include
d
Instruction
M
b
sence of lo
c
f
ired boiler
s
nt shall be
es and Eq
u
h
ould be c
a
d
before ins
t
c
tion 1.4
n
wealth of
M
RTANT!
s
truction M
a
o
n. It must
b
ce.
N
ING!
not use ma
t
ds under pr
e
e
ased. Be s
u
c
rease all tr
a
o
re attempti
u
ts to the u
n
e
exhaust v
e
s
t be compl
e
c
trical volta
g
0
0/3000) O
R
e
d in this eq
u
t
’s front pan
e
i
ngle-pole (
1
alled on the
essible posi
u
nit sheet m
e
T
ION!
n
y soaps u
s
s
ed thoroug
h
NOT use
h
nician to in
s
i
num wit
h
T
Y PRECA
U
7/16/2019
1
: SA
F
N
GS&C
A
a
ting perso
n
a
nd caution
s
d
in these i
n
M
anual, the
c
al codes,
A
s
and AN
S
installed in
u
ipment, C
S
a
refully
f
oll
o
t
allations ar
e
for import
a
M
assachuset
t
a
nual is an
i
b
e given to
t
ches, candl
e
e
ssure may
u
re to shut o
f
a
pped press
u
ng to perfor
m
n
it.
e
nt pipe of t
h
e
tely sealed
g
es up to 12
R
208, 460 o
r
u
ipment. Th
e
e
l) must be i
20 VAC uni
electrical s
u
tion to quic
k
e
tal enclosu
r
s
ed for gas
h
ly with clea
n
this boiler
s
pect and r
e
h
Edge C
o
U
TIONS
Technical S
u
F
ETYP
R
A
UTION
S
n
nel MUST,
s
are gener
a
n
structions.
installation
o
A
NSI Z223.1
S
I/NFPASB
accordance
S
A B149.1,
a
o
wed in all
e
made.
a
nt inform
a
t
s.
i
ntegral par
t
the user b
y
e
s, flames,
o
cause injur
y
f
f all incomi
n
u
res to zero
m
any main
t
h
e unit may
o
to prevent l
e
0 VAC (BM
K
r
575
V
AC (
e
refore the
c
nstalled at
a
ts) or three-
u
pply line of
k
ly and safel
r
es.
pipe leak t
e
n
water afte
r
if any part
e
place any
p
o
ntroller: I
u
pport (800) 5
R
ECAU
T
S
at all tim
e
a
l and must
In addition
o
f units MU
S
(National F
u
for LP ga
with the c
u
a
nd applica
cases. A
u
a
tion regar
d
t
of the pro
d
y
the install
o
r other sou
r
y
to person
n
n
g and outg
o
before perf
o
t
enance on
t
o
perate und
e
e
akage of c
o
K
750 – 20
0
BMK 5000
&
c
over on the
a
ll times, ex
c
pole (220 V
A
the unit. Th
y disconne
c
e
sting are c
o
r
leak chec
k
has been
p
art that has
nstallatio
5
26-0288 Mon
-
T
IONS
e
s, observe
be given th
to all the r
e
S
T conform
uel Gas Co
d
s-fired boil
e
u
rrent Instal
l
ble Provinc
i
u
thorities h
a
d
ing install
d
uct and m
u
er and kep
t
rces of ignit
i
n
el or dama
g
o
ing water
s
o
rming mai
n
t
he unit, sh
u
e
r a positiv
e
o
mbustion
p
0
0) AND 20
8
&
6000) AN
D
unit’s pow
e
c
ept during
m
A
C and hig
h
e switch m
u
c
t electrical
s
o
rrosive to
m
k
s have bee
n
under wat
e
been unde
r
o
n Manual
-
Fri, 8 am - 5 pm
all safety
e same att
e
equirement
s
with local b
u
d
e Publicati
o
e
rs. Where
l
ation Code
ial regulatio
a
ving jurisd
i
ation of
u
u
st be main
t
t
in a safe
p
i
on to chec
k
g
e to equip
m
s
hutoff valve
n
tenance.
u
t off all gas
e
pressure a
p
roducts int
o
8
OR 460
VA
D 24 VOLT
S
e
r panel (loc
a
m
aintenanc
e
h
er units) s
w
u
st be install
e
s
ervice. Do
n
m
etals. The
n
completed
e
r. Call a q
r
water.
EST Page
9
regulations.
e
ntion as s
p
s
included i
n
uilding cod
e
o
n No. NFP
A
applicable
for Gas B
u
ns for the
c
i
ction shoul
u
nits within
t
ained in le
g
p
lace for fu
t
k
for gas lea
k
m
ent when
s. Carefully
and electri
c
nd therefor
e
o
living spac
e
A
C (BMK
S
AC may b
a
ted behind
e
and servic
w
itch must b
e
e
d in an ea
s
n
ot affix swi
t
piping mus
t
.
ualified ser
v
9
of 54
The
p
ecific
n
this
e
s, or,
A
-54)
, the
u
rning
c
lass;
d be
the
g
ible
t
ure
k
s.
c
al
e
e
s.
e
the
ing.
e
s
ily
t
ch
t
be
v
ice
Bench
m
SECTIO
N
OMM-13
6
1.2
E
If overh
e
(Figure 1
NOTE
The In
s
valve t
o
In additi
o
points s
h
F
o
m
a
o
u
s
h
F
o
p
r
id
e
D
e
i
m
F
o
p
r
i
m
1.3
P
If there i
s
manual
g
shut-off
d
If the un
i
the instr
u
Platinu
m
When r
e
instructi
o
Benchm
a
perform
e
V
CL
O
m
ark Plat
i
N
1 – SAFE
T
6_
D • GF-210
E
MERGE
e
ating occu
r
-1) located
e
:
s
taller must i
o
operating
p
o
n, to ensur
e
h
ould be de
s
o
r automati
c
a
nually op
e
u
tside each
h
utdown swi
t
o
r automati
c
ovide a ma
n
e
ntification
a
e
sign the s
y
m
mediately s
o
r boilers
m
ovide an
e
m
mediately s
P
ROLON
G
s
an emerg
e
g
as valve l
o
d
evice.
i
t is being s
h
u
ctions in S
m
-Edge: OP
E
e
turning a
u
o
ns in Secti
o
a
rk Platin
u
e
d to verify t
h
V
ALVE
O
SED
i
num wit
h
T
Y PRECA
U
7/16/2019
NCYSH
U
r
s or the g
a
e
xternal to t
dentify and
p
ersonnel.
Figu
r
e
safety an
e
s
igned and i
m
c
ally opera
t
e
rated rem
o
boiler roo
m
t
ch or circui
t
c
ally operat
e
n
ually oper
a
a
t a location
y
stem so ac
t
hut off the f
u
m
onitored a
e
mergency
s
hut off the f
u
G
EDSH
U
e
ncy, turn o
f
o
cated upst
r
h
ut down fo
r
ection 8.11
:
E
RATIO
N
-S
E
u
nit to serv
i
o
n 4: Initial
S
u
m-Edge:
O
h
at all syste
m
h
Edge C
o
U
TIONS
Technical S
u
U
TDOW
a
s supply fa
he unit.
indicate the
r
e 1-1: Ma
n
e
mergency
s
m
plement a
t
t
ed unatten
o
te shutdow
m
door. D
e
t
breaker wil
e
d unatten
d
a
ted remote
readily acc
e
t
ivation of th
u
el.
nd/or oper
a
s
hutdown
s
u
el upon ac
t
U
TDO
W
f
f the electri
c
r
eam from
t
r
an extend
e
:
Shutting
B
E
RVICE Ma
n
i
ce after a
S
tartup Pro
c
O
PERATIO
N
m
-operating
o
ntroller: I
u
pport (800) 5
2
N
ils to shut
o
location of
t
n
ual Gas
S
s
hutdown pr
o
t
the site:
ded boiler
s
n switch o
r
e
sign the s
y
l immediate
l
d
ed boilers
i
shutdown s
e
ssible in th
e
e emergen
c
a
ted from
a
s
witch in t
h
t
ivation.
W
N
c
al power s
u
t
he unit. Th
e
d period of
B
oiler Down
n
ual (OMM-
prolonged
s
c
edures and
N
-SERVICE
parameter
s
nstallatio
2
6-0288 Mon-
F
o
ff, close t
h
t
he emerge
n
S
hutoff Va
l
r
ocedure th
a
s
located i
n
r
circuit br
e
y
stem so
a
l
y shut off t
h
in a locatio
s
witch or cir
c
e
event of b
o
c
y shutdown
a
continuou
h
e control
r
u
pply to the
e installer
m
f
time, such
For Extend
e
-
0137, GF-2
shutdown,
i
Section 5:
E
Manual
s
are correc
t
VALVE
OPEN
o
n Manual
F
ri, 8 am - 5 pm
E
h
e manual
g
n
cy shutdo
w
l
ve
a
t addresse
s
n
a boiler
r
e
aker locat
e
a
ctivation o
f
h
e fuel suppl
n other tha
c
uit breaker
o
iler mis-op
e
n
switch or c
u
sly occupi
e
r
oom that
AERCO bo
i
m
ust identif
y
as a year o
e
d Period i
n
11).
i
t is recom
m
Safety Dev
i
(OMM-013
7
t
.
E
ST Page 1
g
as shutoff
w
n manual g
a
s
the followi
n
r
oom, provi
e
d just insi
d
f
the emer
g
y to the uni
t
n a boiler
r
marked for
e
ration.
c
ircuit break
e
e
d control
r
is hard-wir
e
i
ler and clo
s
y
the emer
g
r more, co
m
n
the Benc
h
m
ended th
a
i
ce Testing
o
7
, GF-211
)
0 of 54
valve
a
s
n
g
de a
d
e or
g
ency
t
(s).
r
oom,
easy
e
r will
r
oom,
e
d to
s
e the
g
ency
m
plete
h
mark
a
t the
o
f the
)
be
Bench
m
SECTIO
N
OMM-13
6
1.4I
M
Requir
e
BoilerIn
s
followin
g
Boile
Com
m
Prior
teste
The
v
side
w
requ
i
(a)For
building
operate
d
seven(7
)
andpor
c
1. I
N
side
w
obse
r
insta
insta
mon
o
build
be t
h
prof
e
a.I
cra
w
bac
k
b.
co
m
the
bat
t
2. A
requ
i
ANSI
/
3.S
I
exte
r
with
equi
p
VEN
T
m
ark Plat
i
N
1 – SAFE
T
6_
D • GF-210
M
PORT
A
e
ments f
o
s
tallations
w
g
requireme
r must be i
n
m
onwealth
o
tounit op
e
dusingan
o
v
enttermin
a
w
all ventin
i
rementsex
t
all side w
a
orstructure
d
bytheCo
m
)
feetabove
c
hes,thefoll
N
STALLATIO
N
w
all horizo
n
r
vethatah
lled on the
lling plumb
e
o
xide detec
ingorstruc
t
h
e responsi
b
e
ssionalsfor
ntheevent
w
lspaceor
a
k
upmayb
e
In the even
t
m
pletionofi
n
above req
u
t
eryoperat
e
PPROVED
C
i
red in acc
o
/
UL2034lis
t
I
GNAGE: A
r
ior of the
b
theexhaus
t
p
ment. The
T
DIRECTLY
B
i
num wit
h
T
Y PRECA
U
7/16/2019
A
NTF
O
o
r Massa
c
w
ithintheC
o
nts:
n
stalled by
o
fMassach
u
e
ration, the
o
ncorrosive
a
tionmust
b
g is used,
t
ractedfro
m
a
ll horizont
a
usedinwh
o
m
monwealt
h
finishedgr
a
owingrequ
i
N
OF CARB
O
n
tal vented
ardwiredc
a
floor level
e
r or gasfitt
e
tor with a
n
t
ureserved
b
ility of th
e
theinstalla
t
thatthesid
a
nattic,th
e
e
installedo
n
t
that the r
e
n
stallation,
t
u
irements;
p
e
dcarbonm
o
C
ARBON
M
o
rdance wit
h
t
edandIAS
metal or pl
a
b
uilding at a
t
venttermi
sign shall r
e
B
ELOW.KE
E
h
Edge C
o
U
TIONS
Technical S
u
O
RMA
S
c
husetts I
n
o
mmonweal
a plumber
o
u
setts.
completeg
a
soap.
b
elocated
a
the instal
l
m
248CMR
5
a
lly vented
o
leorinpa
r
h
andwher
e
a
deinthea
r
i
rementssh
a
O
N MONO
X
gas fueled
e
a
rbonmon
o
where the
e
r shall obs
n
alarm is i
bytheside
w
e
property
o
t
ionofhard
ewallhoriz
o
e
hardwire
d
n
thenexta
d
e
quirement
s
t
heowners
p
rovided, h
o
o
noxidedet
M
ONOXIDE
D
h
the abov
e
certified.
a
stic identif
i
minimum
h
nalforthe
e
ad, in prin
t
E
PCLEARO
F
o
ntroller: I
u
pport (800) 5
2
S
SACHU
S
n
stallatio
n
thofMassa
o
r a gas fitt
a
s trainand
a
minimum
o
l
ation mus
t
5
.08(2):
gas fueled
r
tforreside
n
e
theside w
r
eaofthev
e
a
llbesatisfi
e
X
IDE DETEC
T
e
quipment,
o
xidedetect
gas equip
m
erve that a
nstalled on
w
allhorizon
o
wner to s
e
wiredcarb
o
o
ntallyvent
d
carbonm
o
d
jacentfloo
r
s
of this su
b
hallhavea
p
o
wever, th
a
ectorwith
a
D
ETECTORS
e
provision
s
i
cation plat
e
h
eight of ei
g
h
orizontally
t
size no le
s
F
ALLOBSTR
nstallatio
2
6-0288 Mon-
F
S
ETTSI
N
n
s
chusettsm
u
t
er who is li
all connec
t
o
f4feet ab
t
conform
equipment
n
tialpurpos
e
allexhaust
v
e
nting,inclu
d
e
d:
T
ORS: At th
e
the installi
n
orwithan
a
m
ent is to
b
battery op
e
each addi
t
talvented
g
e
cure the s
e
o
nmonoxid
e
edgasfuel
e
o
noxidedet
e
rlevel.
b
division ca
n
p
eriodofth
a
t during s
a
a
nalarmsha
S
: Each car
b
s
shall com
e
shall be p
g
ht (8) feet
ventedgas
s
s than one
UCTIONS".
o
n Manual
F
ri, 8 am - 5 pm
E
N
STALL
A
u
stconform
censed wit
h
t
ions must
b
b
ovegradel
e
to the fol
installed i
n
es,includin
g
v
enttermin
dingbutno
t
e time of i
n
n
g plumber
a
larmandb
b
e installed.
e
rated or h
a
t
ional level
g
asfuelede
q
e
rvices of
q
e
detectors.
e
dequipme
n
e
ctorwitha
n
not be m
e
irty(30)da
y
a
id thirty (3
a
llbeinstall
e
r
bon mono
x
ply with N
F
ermanently
above gra
d
fueledhea
t
half (1/2) i
n
(Continued
E
ST Page 1
A
TIONS
tothe
h
in the
b
e leak
e
vel.If
lowing
n
every dw
e
g
thoseown
ationisless
t
limitedto
d
n
stallation
o
or gasfitter
atteryback
In additio
n
a
rd wired c
a
of the dw
e
q
uipment.I
t
q
ualified lic
e
n
tisinstalle
d
larmandb
a
e
t at the ti
m
y
stocompl
y
0) day peri
o
e
d.
x
ide detect
o
F
PA 720 a
n
mounted t
o
d
e directly i
n
t
ingapplian
n
ch in size,
)
1 of 54
e
lling,
edor
than
d
ecks
o
f the
shall
upis
n
, the
a
rbon
e
lling,
t
shall
e
nsed
d
ina
a
ttery
m
e of
y
with
o
d, a
o
r as
n
d be
o
the
n
line
ceor
"GAS
Bench
m
SECTIO
N
OMM-13
6
Requir
e
4.I
N
fuele
obse
r
provi
(b)EXE
M
1.
T
the
2.
roo
m
par
t
(c)MA
N
theman
u
venting
s
provide
d
include:
1.
D
syste
2.A
(d)MA
N
When t
h
equipm
e
systems
"
1.T
h
ore
q
2.
T
instr
u
(e)Aco
gasfuel
e
venting
d
theinsta
m
ark Plat
i
N
1 – SAFE
T
6_
D • GF-210
e
ments f
o
N
SPECTION
:
d equipme
n
r
ves carbo
n
sionsof24
8
M
PTIONS:T
h
T
heequipm
e
mostcurre
n
Product Ap
m
or struct
u
t
forresiden
N
UFACTURE
R
u
facturero
f
s
ystem des
i
d
by the ma
D
etailed inst
mcompon
e
completep
a
N
UFACTUR
E
h
e manufa
c
e
ntdoesnot
"
,thefollow
h
ereferenc
e
q
uipmentin
s
T
he "specia
u
ctionsfort
p
yofall ins
t
e
dequipme
n
d
esigninstr
u
llation.
……………….
[
i
num wit
h
T
Y PRECA
U
7/16/2019
o
r Massa
c
The state
o
n
t shall not
n
monoxid
e
8
CMR5.08(
2
h
efollowin
g
e
ntlistedin
n
teditionof
proved sid
e
u
re separat
e
tialpurpos
e
R
REQUIRE
M
f
ProductA
p
i
gn or venti
nufacturer
f
ructions fo
r
e
nts;and
a
rtslistfort
E
R REQUIRE
M
c
turer of a
provideth
e
ingrequire
m
e
d"specialv
s
tallationin
s
l venting s
y
hatsystem
s
t
allationins
t
n
t,allventi
n
u
ctionsshal
l
[
EndofExtr
a
h
Edge C
o
U
TIONS
Technical S
u
c
husetts I
n
o
r local gas
approve th
e
e
detectors
2
)(a)1throu
g
g
equipment
Section10
e
NFPA54as
e
wall horiz
o
e
from the
e
s.
M
ENTS‐GA
p
provedsid
e
ng system
f
or installat
i
r
the install
a
heventing
s
M
ENTS‐G
A
Product A
p
e
partsforv
m
entsshall
b
entingsyst
e
s
tructions;a
y
stems" sh
a
s
hallinclud
e
t
ructionsfo
r
n
ginstructi
o
l
remainwi
t
a
ctedInfor
m
o
ntroller: I
u
pport (800) 5
2
n
stallatio
n
inspector
o
e
installatio
n
and sign
a
g
h4.
isexemptf
e
ntitled"Eq
adoptedby
o
ntally vent
dwelling, b
u
S EQUIPME
e
wallhoriz
o
component
s
on of the
e
a
tion of th
e
s
ystemdesi
g
A
S EQUIPM
E
p
proved sid
entingthef
b
esatisfied
b
e
m"instruct
i
nd
a
ll be Prod
e
apartslist
r
allProduc
t
o
ns,allpart
s
t
htheappli
a
m
ationFro
m
nstallatio
2
6-0288 Mon-
F
n
s
o
f the side
w
n
unless, up
a
ge installe
rom248C
M
uipmentN
o
y
theBoard;
ed gas fuel
e
u
ilding or s
t
NT VENTIN
G
o
ntallyvent
e
s
with the
e
quipment
a
e
venting s
y
g
norventin
g
ENT VENTI
N
d
e wall hor
i
f
luegases,b
b
ytheman
u
i
onsshallb
e
d
uct Appro
v
anddetaile
d
t
Approved
s
s
lists forve
n
a
nceorequ
m
248CMR
5
o
n Manual
F
ri, 8 am - 5 pm
E
w
all horizo
n
p
on inspecti
o
d in accor
M
R5.08(2)(a
)
o
tRequired
T
and
ed equipm
e
t
ructure us
e
G
SYSTEM
P
e
dgasequi
p
equipment,
a
nd the ven
t
y
stem desig
g
system.
N
G SYSTEM
izontally v
e
utidentifie
s
u
facturer:
e
included
w
v
ed by the
d
installatio
n
s
idewallh
o
ntinginstru
c
ipmentatt
h
5
.08(2)]……
E
ST Page 1
n
tally vente
d
o
n, the insp
dance wit
h
)
1through
4
T
oBeVent
e
e
nt installe
d
e
d in whole
P
ROVIDED.
W
p
mentprovi
the instru
c
t
ing system
n or the v
e
NOT PROV
e
nted gas f
u
s
"specialv
e
w
iththeappl
Board, an
d
n
instructio
n
o
rizontallyv
e
c
tions,and
/
h
ecomple ti
…………
2 of 54
d
gas
ector
h
the
4
:
e
d"in
d
in a
or in
W
hen
desa
c
tions
shall
e
nting
IDED.
u
eled
e
nting
iance
d
the
n
s.
e
nted
/
orall
onof
Bench
m
SECTIO
N
OMM-13
6
SEC
T
2.1I
N
This sec
t
A
ERCO
2.2
R
Each Be
BMK mo
B
B
B
B
B
The unit
damage.
shipmen
t
signed.
CAU
T
While
p
from th
e
NOTE
indicat
o
during
s
inform
a
adjust
e
be ma
d
2.3
U
Carefull
y
packagi
n
A
fter un
p
damage
immedia
t
The follo
the unit’
s
P
r
A
S
C
o
A
o
n
m
ark Plat
i
N
2 – INST
A
6_
D • GF-210
T
ION
2
N
TROD
U
t
ion provide
s
Benchmark
R
ECEIVI
N
nchmark B
o
dels is appr
o
B
MK 750:
B
MK 1000:
B
MK 1500/2
0
B
MK 2500/3
0
B
MK 5000/6
0
must be m
o
The unit
t
completen
T
ION!
p
ackaged in
e
front onl
y
:
A
ERCO is
o
r on the ou
t
s
hipment. If
a
tion on the
c
r before pro
d
e clear to t
h
U
NPACK
y
unpack th
e
n
g materials
p
acking, m
a
not indica
t
t
ely if any d
a
wing acces
s
s
shipping c
o
r
essure/Te
m
S
ME Press
u
o
ndensate
D
1”, 1-1/2”
o
n
Propane
a
i
num wit
h
A
LLATION
7/16/2019
2
: INST
A
U
CTION
s
the descri
Platinum B
o
N
GTHE
U
o
iler System
o
ximately a
s
1100
1200
0
00: 1800
0
00: 2200
0
00: 3,53
0
o
ved with t
h
s
hould be
ess at the
t
the shippin
g
y
.
not respon
s
t
side of the
c
the Tip-N-T
e
c
arrier’s pa
p
ceeding. A
n
h
e deliverin
g
ING
e
unit takin
a
ke a close
t
ed by the
a
mage is de
s
ories come
o
ntainer or
a
m
perature
G
u
re Relief
V
D
rain Trap
o
r 2” Natu
r
a
nd Dual F
u
h
Edge C
o
Technical S
u
A
LLATI
ptions and
p
o
ile
r
s.
U
NIT
is shipped
a
s
follows:
lbs. (499 k
g
lbs. (544 k
g
lbs. (817 k
g
lbs. (1000
k
0
lbs. (1601
k
h
e proper ri
g
completely
t
ime of rec
e
g
container,
s
ible for lost
c
rate, which
e
ll indicator
p
erwork and
y other visu
carrier.
g care not
inspection
Tip-N-Tell
tected.
standard w
i
a
re factory i
n
G
auge
V
alve
(P/N 24441
)
r
al Gas Su
p
u
el units
o
ntroller: I
u
pport (800) 5
2
ON
p
rocedures
n
a
s a single
c
g
)
g
)
g
).
k
g)
k
g)
g
ging equip
inspected
f
e
ipt from th
e
the unit mu
s
or damage
d
indicates if
is tripped, d
request a f
r
al damage t
to damage
of the unit
indicator.
T
i
th each uni
t
n
stalled on t
h
)
p
ply Shuto
ff
nstallatio
2
6-0288 Mon-
F
necessary t
o
c
rated unit.
T
ment for sa
f
or evidenc
e
e
carrier an
d
s
t be moved
d
freight. Ea
c
the unit has
d
o not sign f
o
r
eight claim
a
t
o the packa
the unit e
n
to ensure
t
T
he freight
t
and are ei
t
h
e unit:
f
f Valve, an
d
o
n Manual
F
ri, 8 am - 5 pm
E
o
unpack, i
n
T
he shippin
g
fety and to
e
of shippi
d
before th
e
by pallet ja
c
c
h unit has
A
been turne
d
o
r the ship
m
and inspect
i
ging materi
a
n
closure w
h
t
hat there i
s
carrier sh
t
her packed
d a Propa
n
E
ST Page 1
n
spect and i
g
weight for
t
avoid equi
p
ng damag
e
e
bill of lad
i
c
k or forklift
A
Tip-N-Tell
d
on its sid
e
m
ent. Note t
h
i
on by a clai
a
ls should a
l
h
en cutting
s
no eviden
ould be n
o
separately
w
n
e Shutoff
V
3 of 54
nstall
t
hese
p
ment
e
and
i
ng is
e
h
e
ms
l
so
away
ce of
o
tified
w
ithin
V
alve
Bench
m
SECTIO
N
OMM-13
6
When o
containe
standard
until rea
d
2.4
S
Ensure t
h
A
s
A
G
A
Bench
m
concrete
inch (10
In additi
o
such tha
t
Figures
2
2.4.1
I
All Ben
c
installed
minimu
m
if Local
B
require
m
The min
i
F
S
R
T
A
ll gas
p
interfere
In multip
space fo
into con
s
NOTE
:
Bench
m
cleara
n
If installi
n
combina
t
have a
p
Boilers i
n
Section
SERVIC
E
m
ark Plat
i
N
2 – INST
A
6_
D • GF-210
ptional acc
e
r
, factory in
or optional
d
y for install
a
S
ITEPRE
h
at the site
s
A
ccess to
a
s
pecified in
t
A
ccess to A
C
G
uide (TAG
-
A
level conc
r
m
ark 750/10
0
“housekee
p
.2 to 20.3 c
m
o
n, to ensur
e
t
the conde
n
2
-1a – 2-1d.
I
nstallati
o
c
hmark mod
with the pr
e
m
clearance
B
uilding Co
d
m
ents.
i
mum acce
p
BMK 75
0
F
ront: 24 in
c
S
ides: 24 in
c
R
ear: 24 in
c
T
op: 18 in
c
p
iping, wate
r
with the re
m
le unit instal
r piping co
n
s
ideration.
A
:
m
ark units
m
n
ces still ap
p
n
g a Combi
t
ion mode,
b
p
anel want
n
advance
a
6.6: Combi
n
E
Manual (
G
i
num wit
h
A
LLATION
7/16/2019
e
ssories a
r
stalled on
t
accessorie
s
a
tion or use
.
PARATI
O
s
elected for
a
natural ga
t
he Benchm
a
C
input po
w
-
0048, GF-2
r
ete housek
e
0
0 units mu
s
p
ing” pad.
B
m
) concrete
e
proper co
n
n
sate asse
m
o
nClear
a
els are the
e
scribed cle
a
dimensions
,
d
es require
p
table clea
r
0
- 3000
c
hes (61 cm
)
c
hes (61 cm
)
c
hes (61 cm
)
c
hes (45.7 c
m
piping and
m
oval of any
lations, it is
n
nections a
n
A
ll piping m
u
m
ay be instal
p
ly. See dra
w
nation Cont
b
ut can still
to continue
nd place th
e
n
ation Con
t
G
F-211).
h
Edge C
o
Technical S
u
e ordered,
t
he unit, or
s
shipped l
o
.
O
N
installation
o
s and/or p
r
a
rk Pre-Inst
a
w
e
r
specifie
d
060).
e
eping pad,
s
t be installe
d
B
enchmark
1
housekeep
n
densate dr
a
m
bly is not lo
c
a
nces
same heig
a
rances for
,
r
equired b
y
additional
c
r
ances req
u
)
)
)
m
)
F
S
R
T
electrical c
o
panels, or i
important t
o
n
d future se
r
u
st include a
led with zer
o
w
ings in Ap
p
rol System
be used if
to use it),
e
m in the pr
t
rol System
o
ntroller: I
u
pport (800) 5
2
they may
packed an
d
o
ose should
o
f the Benc
h
r
opane gas
a
llation Gas
d
in the Ben
as describ
e
d
on a level
1
500 – 6000
ing pad to e
a
inage, you
m
c
ated over t
ht, but var
y
service as
s
y
AERCO,
a
c
learances,
u
ired are as
f
BMK 50
0
ront : 48 in
c
S
ides: 24 in
c
R
ear: 24 in
c
T
op: 18 in
c
o
nduit or ca
b
nhibit servi
c
o
plan the p
o
r
vice/mainte
mple provis
i
o
side clear
a
p
endix A: Di
m
(
CCS) usin
g
installing w
i
it is import
o
per physic
a
of the Be
n
nstallatio
2
6-0288 Mon-
F
be packe
d
d
shipped i
n
be identifie
h
mark Plati
n
supply tha
t
Supply Gui
d
chmark Pre
e
d below:
4 to 6 inch
units must
nsure prop
e
must ensur
e
he houseke
y
in depth
b
s
hown in Fi
g
a
re listed be
these code
s
follows:
0
0-6000
c
hes (122 c
m
c
hes (61 cm
c
hes (61 cm
c
hes (45.7 c
b
le must be
c
e or mainte
n
o
sition of ea
c
nance requ
i
ions for exp
a
a
nces in pai
m
ensions a
n
g
an ACS p
a
i
th a legac
y
t
ant to iden
t
a
l location.
F
n
chmark P
l
o
n Manual
F
ri, 8 am - 5 pm
E
d
within th
e
n
a separat
e
d and store
d
n
um Boiler i
n
t
conforms
t
i
de (TAG-00
4
-Installation
(10.2 to 15
.
be installed
e
r condensa
t
e
that the u
n
eping pad,
a
b
y model.
T
g
ure 2-1a t
h
low for all
m
s shall sup
e
m
)
)
)
m)
arranged s
o
n
ance of th
e
c
h unit in a
d
i
rements m
u
a
nsion.
rs only. The
n
d Clearanc
e
anel (
A
CS i
y
BMK unit,
t
ify the Co
m
F
or more in
f
l
atinum-Edg
e
E
ST Page 1
e
unit’s shi
p
e
container
.
d
in a safe
n
cludes:
t
o the pres
s
47, GF-203
0
Electrical
P
.
2 cm) a
on a level
4
t
e drainage.
n
it is positio
n
a
s shown in
T
he unit mu
h
rough 2-1d
m
odels. Ho
w
e
rsede AE
R
o
that they
d
e
unit.
d
vance. Suf
f
u
st also be
t
perimeter
e
Drawings.
s not need
e
or if you al
r
m
bination
M
f
ormation re
e
: OPERA
T
4 of 54
p
ping
.
Any
place
s
ures
0
).
P
ower
4
to 8
n
ed
st be
. The
w
ever,
R
CO’s
d
o not
f
icient
t
aken
e
d for
r
eady
M
ode
fer to
T
IO
N
-
Bench
m
SECTIO
N
OMM-13
6
m
ark Plat
i
N
2 – INST
A
6_
D • GF-210
NOT
E
Ensure
t
conden
s
assembl
not loca
over t
h
houseke
e
p
ad.
4
i
num wit
h
A
LLATION
7/16/2019
Figur
e
Figure
E
:
t
hat
s
ate
y is
t
ed
h
e
e
ping
4
” High Pad
h
Edge C
o
Technical S
u
e
2
-1a: B
M
2
-1b: BM
K
NOT
E
Ensure t
h
condens
a
assembl
y
not locat
e
over th
e
housekee
p
p
ad.
o
ntroller: I
u
pport (800) 5
2
M
K 750/100
0
K
1500/20
0
E
:
h
at
a
te
y
is
e
d
e
p
ing
nstallatio
2
6-0288 Mon-
F
0
Clearan
c
0
0 Cleara
n
o
n Manual
F
ri, 8 am - 5 pm
E
c
es
n
ces
E
ST Page 1
5 of 54
Bench
m
SECTIO
N
OMM-13
6
m
ark Plat
i
N
2 – INST
A
6_
D • GF-210
Fig
u
i
num wit
h
A
LLATION
7/16/2019
Figure
u
re
2
-1d:
B
Housekee
p
NOTE:
Ensure th
a
condensa
t
assembly
i
not locate
d
over the
housekeepi
p
ad.
h
Edge C
o
Technical S
u
2
-1c: BM
K
B
enchmar
k
p
ing Pad.
a
t
t
e
i
s
d
ng
o
ntroller: I
u
pport (800) 5
2
K
2500/30
0
k
Model 50
0
nstallatio
2
6-0288 Mon-
F
0
0 Cleara
n
00 & 6000
o
n Manual
F
ri, 8 am - 5 pm
E
n
ces
Clearanc
e
E
ST Page 1
e
s
6 of 54
Bench
m
SECTIO
N
OMM-13
6
W
AR
N
Keep t
h
liquids
.
FOR M
For Mas
s
within th
e
require
m
2.4.2
S
If ancho
r
A
A
m
ark Plat
i
N
2 – INST
A
6_
D • GF-210
N
ING!
h
e unit area
ASSACH
U
s
achusetts i
n
e
Common
w
m
ents specifi
e
S
ettingt
h
r
ing the unit,
A
ll holes are
A
ll dimensio
n
F
i
num wit
h
A
LLATION
7/16/2019
clear and fr
e
U
SETTS
O
n
stallations,
w
ealth of Ma
s
e
d in Sectio
n
h
eUnit
refer to Fig
u
flush with t
h
n
s shown ar
e
F
igure
2
-2a
h
Edge C
o
Technical S
u
e
e from all
c
O
NLY:
the unit mu
s
sachusett
s
n
1.4, abov
e
u
re 2-2a thr
o
h
e bottom s
u
e
in inches [
m
:
BMK 75
0
/
o
ntroller: I
u
pport (800) 5
2
c
ombustible
st be install
e
s
. In addition
e
.
o
ugh 2-2d f
o
u
rface of the
m
illimeters]
0
/
1000 Anc
h
nstallatio
2
6-0288 Mon-
F
materials a
n
e
d by a plu
m
, the install
a
o
r anchor lo
c
frame.
h
or Bolt L
o
o
n Manual
F
ri, 8 am - 5 pm
E
n
d flammabl
m
ber or gas-
a
tion must c
o
c
ations.
o
cations
E
ST Page 1
e vapors or
fitter licens
e
o
mply with
a
7 of 54
e
d
a
ll
Bench
m
SECTIO
N
OMM-13
6
m
ark Plat
i
N
2 – INST
A
6_
D • GF-210
Fi
g
Fi
g
Figure
2
i
num wit
h
A
LLATION
7/16/2019
g
ure
2
-2b:
g
ure
2
-2c:
2
-2d. Ben
c
FRONT
h
Edge C
o
Technical S
u
BMK 150
0
BMK 250
0
c
hmark 50
0
o
ntroller: I
u
pport (800) 5
2
0/
2000 An
c
0
/3000 An
c
0
0 and 60
0
nstallatio
2
6-0288 Mon-
F
c
hor Bolt
L
c
hor Bolt
L
0
0 Anchor
o
n Manual
F
ri, 8 am - 5 pm
E
L
ocations
L
ocations
Bolt Loca
t
E
ST Page 1
t
ions
REAR
8 of 54
Bench
m
SECTIO
N
OMM-13
6
2.5
L
W
AR
N
When l
i
train or
2.5.1
B
Unpack
shipping
provided
exchang
e
shipped,
lifting ta
b
the liftin
g
W
AR
N
When
u
Attach
i
1. Rem
o
A
).
R
2. Rem
o
exch
a
3.
A
tta
c
(Fig
u
posit
i
4. Usin
g
posit
i
5.
A
fter
the t
o
LIFTING
BAR IN
SHIPPIN
G
POSITIO
N
LIFTI
N
TAB
V
m
ark Plat
i
N
2 – INST
A
6_
D • GF-210
L
IFTING
P
N
ING!
i
fting or mo
v
blower.
B
MK750
and inspec
t
pallet. The
in the bas
e
e
r. A lifting
b
this bar is
a
b
is provide
d
g
bar to the
u
N
ING!
u
sing the lifti
i
ng the Li
f
o
ve the lifti
n
R
etain the tw
o
ve the top
a
nger.
c
h the lifting
re 2-3a, Vi
e
i
oned over t
h
g
proper rig
i
on it on the
the boiler i
s
o
p of the uni
Fi
g
G
N
N
G
V
IEW A - S
H
i
num wit
h
A
LLATION
7/16/2019
P
ROVISI
v
ing the boil
e
1000
L
t
the unit, t
h
boiler can
e
of the uni
t
b
ar (P/N 59
1
a
ttached to
d
at the top
o
u
nit, as des
c
ng tab and
b
f
ting Bar:
n
g bar from
o (2) hex h
e
shroud fro
m
bar to the h
e
e
w B). The
u
h
e top of th
e
ging equip
m
housekeepi
s
properly s
e
t, but retain
g
ure
2
-3a:
B
H
IPPING PO
h
Edge C
o
Technical S
u
ONS
e
r, DO NO
T
L
iftingPr
o
h
en remove
be lifted an
d
t
, or it can
b
1
74), with a
t
the rear of
o
f the unit’s
h
c
ribed belo
w
b
ar, ensure
BMK 750
its shipping
e
ad cap scr
e
m
the boiler
a
e
at exchan
g
u
pper end o
f
e
heat exch
a
m
ent capabl
ng pad.
e
t on the pa
the lifting b
a
B
MK 750/
1
SITION
o
ntroller: I
u
pport (800) 5
2
T
attempt to
m
o
visions
the four (
4
d
moved b
y
b
e lifted by
t
taching ha
r
the unit as
s
h
eat excha
n
w
.
t
here is no l
o
/1000 Ins
t
location at
e
ws, hex nut
s
a
nd locate t
g
er lifting ta
b
f
the lifting b
a
nger as sh
o
e of lifting
1
d, detach t
h
a
r for possi
b
1
000 Boile
r
LIFTING B
A
IN LIFTING
POSITION
V
I
E
nstallatio
2
6-0288 Mon-
F
m
anipulate t
4
) lag scre
w
y
inserting f
o
attaching a
r
dware, is s
u
s
hown in Fi
n
ger as sho
w
oad placed
o
t
ructions
the rear of
s
and flat w
a
he lifting ta
b
b
using the
h
ar containin
o
wn.
1
200 lbs. (
5
h
e lifting bar
b
le reuse at
t
r
Lifting P
r
A
R
G
E
W B - LIF
T
o
n Manual
F
ri, 8 am - 5 pm
E
t
he boiler us
w
s securing
o
rklift tines
lifting bar
t
u
pplied with
gure 2-3a (
V
w
n. This tab
on the gas t
the unit (Fi
g
a
shers.
b
at the top-
h
ardware re
m
g the oval
c
5
44 kg), lif
t
r
and replac
e
t
he installati
o
r
ovisions
T
ING POSI
T
E
ST Page 1
ing the gas
the boiler t
o
in the front
t
o the unit’s
each unit.
W
V
iew A). O
n
is used to
a
t
rain or blow
g
ure 2-3a,
V
rear of the
h
m
oved in st
e
c
utout shoul
d
t
the boiler
e
the shrou
d
o
n site.
T
ION
9 of 54
o
the
slots
heat
W
hen
n
e (1)
a
ttach
er.
V
iew
h
eat
e
p 1
d
be
and
d
on
T
r
l
Bench
m
SECTIO
N
OMM-13
6
2.5.2
B
Three lif
t
Remove
(4) lag
s
position
i
in the de
2.5.3
B
Two (2) l
location
o
Remove
remove
t
it on the
W
AR
N
When l
i
blower.
excess
i
LI
N
T
he front to
p
r
emoved to
l
ifting lug.
m
ark Plat
i
N
2 – INST
A
6_
D • GF-210
B
MK150
t
ing lugs are
the front to
s
crews sec
u
i
t on the 4 i
n
sired locati
o
Figure
2
B
MK500
ifting lugs a
r
o
f the lifting
the four (4)
t
he front To
p
(required) c
o
N
ING!
i
fting or mo
v
A spreade
r
i
ve force on
FTING LU
G
O
TE:
p
panel mu
s
access the
f
i
num wit
h
A
LLATION
7/16/2019
03000
provided a
t
p
panel fro
m
u
ring the un
n
ch to 8 in
c
o
n.
2
-3b: Boil
e
06000L
i
r
e provided
tabs is mar
k
lag screws
s
p
Panel. Lif
t
o
ncrete Ho
u
v
ing the boil
e
r
bar is requi
the unit an
d
Fi
g
G
S
s
t be
f
ront
h
Edge C
o
Technical S
u
LiftingP
r
t
the top of t
h
m
the unit t
o
it to the s
h
c
h (10.2 c
m
e
r Lifting
P
i
ftingPr
o
a
t the top o
f
k
ed on the s
s
ecuring th
e
t
the unit off
u
sekeeping
P
e
r, do not at
t
red for all v
e
d
can cause
g
ure
2
-3c:
L
o
ntroller: I
u
pport (800) 5
2
r
ovision
s
h
e primary
h
o
provide ac
c
ipping skid.
m
to 20.3 c
m
P
rovisions
o
visions
f
the primar
y
hrink-wrap
c
e
unit to the
s
the shippin
g
P
ad in the d
e
t
empt to ma
e
rtical lifts.
F
boiler failur
e
L
ifting Lug
nstallatio
2
6-0288 Mon-
F
s
h
eat exchan
c
ess to the
.
Lift the u
n
m
) houseke
e
– BMK 15
0
y
heat exch
a
c
oving the u
s
hipping ski
g
skid using
e
sired locat
i
nipulate the
F
ailure to us
e
e
.
Locations
LIFTING L
U
YELL
O
o
n Manual
F
ri, 8 am - 5 pm
E
ger as sho
w
lifting lugs.
n
it off the s
h
e
ping concr
e
0
0/2000 S
h
a
nger (see
F
nit for shipp
d, and, if sti
l
a spreader
i
on.
unit using t
e
a spreade
U
GS (3 POSI
T
O
W ARROW
S
E
ST Page
2
w
n in Figure
Remove th
e
h
ipping ski
d
e
te pad (req
u
h
own
F
igure 2-3c).
ing.
l
l in place,
bar and po
s
he gas train
r bar can p
u
T
IONS)
S
2” NATU
R
GAS OR
PROPA
N
INLET
2
0 of 54
2-3b.
e
four
d
and
u
ired)
The
s
ition
or
u
t
R
AL
1”
N
E GAS
/