COL-MET AF-13-08-23-SB-04 is a crossflow spray booth designed for efficient and safe painting applications. It features a non-reverse airflow system that ensures a clean and controlled painting environment by preventing overspray from contaminating the workspace. The booth is constructed with durable galvanized steel panels and includes a variety of components to enhance its functionality, including:

  • Plenum with filter racks for effective air filtration
  • Wall and roof panels for enclosing the workspace
  • Front face with access door for easy entry and exit
  • Electrical components such as lights, fan, and air solenoid valve for convenient operation

COL-MET AF-13-08-23-SB-04 is a crossflow spray booth designed for efficient and safe painting applications. It features a non-reverse airflow system that ensures a clean and controlled painting environment by preventing overspray from contaminating the workspace. The booth is constructed with durable galvanized steel panels and includes a variety of components to enhance its functionality, including:

  • Plenum with filter racks for effective air filtration
  • Wall and roof panels for enclosing the workspace
  • Front face with access door for easy entry and exit
  • Electrical components such as lights, fan, and air solenoid valve for convenient operation
CROSSFLOW INSTALL MANUAL
B
WT:
SCALE: 1:50
SHEET 1 OF 9
DO NOT SCALE DRAWING
WWW.COLMETSB.COM
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
13
2
SIZE
1
REV
WT:
SCALE: 1:50
SHEET 1 OF 9
DO NOT SCALE DRAWING
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
REV
3
2
SIZE
B
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
DWG TITLE
REFER TO THE INCLUDED PACKING LIST FOR MORE
INFORMATION ON PARTS AND PART NUMBERS.
CONTENT PAGE
PLENUM INTRO 2
PLENUM WALLS ASSEMBLY 3
PLENUM FILTER INSTALL 4
WALL INSTALL 5
WALL AND ROOF INSTALL 6
FRONT FACE INSTALL 7
DOOR INSTALL 8
ELECTRICAL INSTALL 9
PLENUM INSTALL INSTRUCTIONS
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:30
SHEET 2 OF 9
DO NOT SCALE DRAWING
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:30
SHEET 2 OF 9
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
1
10
10
5.
6.
AND PANEL 5
ATTACH FAN PANEL 4 TO TIE CHANNEL 10
4 4.
5
ATTACH PANEL 5 TO PANEL 2 AND PANEL 1
ANCHOR TIE CHANNEL 10 TO THE FLOOR1.
ATTACH PANEL 1 TO CHANNEL 10 WITH 2.
SUPPLIED 5/16"Ø NUTS AND BOLTS
ATTACH PANELS 2 TO PANEL 1 ON BOTH 3.
SIDES
ATTACH PANEL 2
2
1
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:35
SHEET 3 OF 9
DO NOT SCALE DRAWING
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:35
SHEET 3 OF 9
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
PLENUM INSTALL INSTRUCTIONS
PLENUM INSTALL INSTRUCTIONS
8
7
3.
ATTACH FILTER RACKS 9 TO PANELS 7 AND 64.
7
7
2.
ATTACH PANEL 6 TO FAN PANEL AND PANELS
PLACE FLOOR CHANNEL 8 ON GROUND1.
ATTACH PANEL 7 TO PANEL 1 ON BOTH SIDES
9
6
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:30
SHEET 4 OF 9
DO NOT SCALE DRAWING
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:30
SHEET 4 OF 9
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:40
SHEET 5 OF 9
DO NOT SCALE DRAWING
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:40
SHEET 5 OF 9
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
17
11
12
19
18
21
16
16
16
26
20
25
27
25
17
16
17
27
WALL AND ROOF INSTALL INSTRUCTIONS
ATTACH PANELS 11 TO PLENUM1.
ATTACH PANEL 12 TO PANEL 11 2.
AND PLENUM
ANCHOR TIE CHANNEL 21 AND26 3.
TO FLOOR
ATTACH PANEL 16 ON LEFT SIDE4.
ATTACH ACCESS DOOR 19 TO 5.
RIGHT SIDE
ATTACH PANEL 18 TO ACCESS 6.
DOOR
ATTACH TIE CHANNEL 25 TO BOTH 7.
SIDES
ATTACH PANEL 20 TO ACCESS 8.
DOOR
ATTACH PANEL 16 ON RIGHT SIDE9.
ATTACH PANEL 17 TO LEFT SIDE10.
REPEAT STEPS 9 & 1011.
ATTACH TIE CHANNEL 27 TO BOTH 12.
SIDES
CONDIT IONS TO B E SU PPLI E D BY OTHE R S .
ADDIT I ONAL DU C T W O R K S U P P ORT TO SU I T FIEL D
ALL ANC H O R B O L T S TO BE SUP P L IED BY OT H ERS.
WALL AND ROOF INSTALL INSTRUCTIONS
REPEAT STEPS 3 & 4 UNTIL YOU HAVE WHAT IS SHOWN HERE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:35
SHEET 6 OF 9
DO NOT SCALE DRAWING
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:35
SHEET 6 OF 9
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:35
SHEET 7 OF 9
DO NOT SCALE DRAWING
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:35
SHEET 7 OF 9
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
15A
13
15 14
WALL AND ROOF INSTALL INSTRUCTIONS
ATTACH PANELS 13 TO BOOTH WALLS ON BOTH 1.
SIDES
ATTACH PANEL 14 TO BOOTH ROOF2.
ATTACH DOOR STOP 15A TO PANEL 143.
ATTACH DOOR 15 (SEE STEPS ON NEXT PAGE)4.
DOOR INSTALL INSTRUCTIONS
ATTACH LEFT DOOR 1.
SIDE BY BOLTING 10
GAUGE DOOR CHANNEL
TO PLENUM PANELS
REPEAT FOR OPPOSITE 2.
SIDE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:30
SHEET 8 OF 9
DO NOT SCALE DRAWING
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:30
SHEET 8 OF 9
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:30
SHEET 9 OF 9
DO NOT SCALE DRAWING
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
D
C
B
A
A
B
C
D
1
23
4
5
678
8
7
6 5
4
3
2
1
SIZE
B
REV
WT:
SCALE: 1:30
SHEET 9 OF 9
DO NOT SCALE DRAWING
COL-MET SPRAY BOOTHS
1635 INNOVATION DR.
ROCKWALL, TX 75032
PHONE (972) 772-1919
FAX (972) 772-1833
WWW.COLMETSB.COM
CROSSFLOW NON REVERSE GUIDE
DWG TITLE
HAVE A CERTIFIED ELECTRICIAN INSTALL THE LIGHTS,
FAN, MANOMETER AND AIR SOLENOID VALVE.
INSTALL ELECTRICS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

COL-MET AF-13-08-23-SB-04 Operating instructions

Type
Operating instructions
This manual is also suitable for

COL-MET AF-13-08-23-SB-04 is a crossflow spray booth designed for efficient and safe painting applications. It features a non-reverse airflow system that ensures a clean and controlled painting environment by preventing overspray from contaminating the workspace. The booth is constructed with durable galvanized steel panels and includes a variety of components to enhance its functionality, including:

  • Plenum with filter racks for effective air filtration
  • Wall and roof panels for enclosing the workspace
  • Front face with access door for easy entry and exit
  • Electrical components such as lights, fan, and air solenoid valve for convenient operation

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI