Johnson Controls FlexSys Elan-06R-180 Installation & Operation Manual

Type
Installation & Operation Manual
FlexSys Underoor Air Terminal (Constant Volume)
Élan - 06R - 180
Model:
©2016 Johnson Controls | The performance specications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specications, consult the local
Johnson Controls ofce. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products.
© 2016 AirFixture, LLC
1
Installation / Operation Manual
V160829
TOOLS REQUIRED:
1. Power Screwdriver (low torque setting)
• Phillips #3 Bit - oor panel screws
• Allen-Head Bit (5/32" / 4mm) - retention bar center screw
2. Panel Lifter (suction cups) - remove oor panels
3. Jigsaw - cut opening in oor panel (if panels are not pre-cut)
4. Carpet Knife - cut opening in carpet tile / oor covering
MATERIALS REQUIRED:
1. Élan-06R-180 Underoor Air Terminal
PREPARATION:
1. Verify that the Élan-06R-180 is the correct model, unit count
and location(s) per scheduled placement.
2. Remove the oor covering / oor panel at the desired
location(s) (if installed).
3. Verify that all adjacent oor panels are properly installed.
INSTALLATION:
The Élan-06R-180 is designed for drop-in installation in a oor
panel. If the oor panel was installed with a 6"Ø [+1/8"/-0"]
(152mm [+3.175/-.00]) round hole pre-cut, skip to Step 2. If the
unit is being added to an existing installation, begin with Step 1.
IMPORTANT: When adjusting the center screw to loosen
or tighten the retention bar, a power screw driver on a LOW
TORQUE SETTING is recommended. Overtightening can
warp the sliding damper plate, resulting in the inability to
adjust air ow.
Take care to avoid slippage of the driver bit;
this may result in scratch damage to the diffuser grille.
1. Remove the oor panel and cut a 6"Ø [+1/8"/-0"]
(152mm [+3.175/-.00]) round opening for the Élan terminal.
Cut opening in carpet tile using same dimensions / position.
Replace oor panel / carpet tile when nished.
NOTE: Floor panels with pre-cut openings may be
supplied by ooring manufacturer.
2. Verify that there is enough clearance between the retention
bar and diffuser grille to allow the collapsable arms to fold in
and clear the edge of the opening. If there is not enough
clearance, turn the center screw counter-clockwise to lower
the retention bar.
3. Insert the Élan terminal into the opening in the oor panel.
The collapsable arms of the retention bar should fold back
out to their default position once the opening is cleared.
4. To secure the Élan terminal in place, tighten the
retention bar to the underside of the oor panel
by turning the center screw clockwise.
5. For protection of the grille’s nish during
construction, a Grille Cover is recommended.
REFER TO PAGE 2 FOR ADDITIONAL INFORMATION:
OPERATION / MAINTENANCE / PARTS
ALL DIMENSIONS NOMINAL +/- 0.1" (2.5mm)
6.75
171mm
6ӯ
152mm
5.8
147mm
COLLAPSABLE
RETENTION BAR
5
127mm
FlexSys Underoor Air Terminal (Constant Volume)
Élan - 06R - 180
Model:
©2016 Johnson Controls | The performance specications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specications, consult the local
Johnson Controls ofce. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products.
© 2016 AirFixture, LLC
2
Installation / Operation Manual
V160829
OPERATION:
• Increase Air Flow:
Slide control lever in a counter-clockwise direction to open
the damper plate, increasing air ow.
• Reduce Air Flow:
Slide control lever in a clockwise direction to close the
damper plate, reducing air ow.
MAINTENANCE:
To remove debris that has collected in the catch pan:
1. Turn center screw counter-clockwise to loosen retention bar.
Set retention bar as low as possible, to allow easier access
to the catch pan.
2. Lift unit as far up as possible. Keep unit level; tilting it too far
may cause debris to dump out under the oor.
3. While holding unit, vacuum debris out of the catch pan.
4. Lower unit back down into oor. Using center screw, tighten
retention bar to secure unit back in place.
PARTS:
• Grille Cover: P/N 620.0120.05
  • Page 1 1
  • Page 2 2

Johnson Controls FlexSys Elan-06R-180 Installation & Operation Manual

Type
Installation & Operation Manual

Ask a question and I''ll find the answer in the document