  • Hello, I'm your chat assistant. I have analyzed the ventilation instructions for Dometic refrigerators, encompassing models like RH430LD, RH436D, and others. This document explains vital ventilation requirements to ensure optimal refrigerator performance. Feel free to ask me any questions related to the installation.
  • What is the minimum open area required for ventilation?
    What is the minimum size of ventilation duct?
    What should I do if installing the refrigerator in a cabinet?
VENT INSTRUCTIONS
Form No. 3308190.002 1/03
©2003 Dometic Corporation
LaGrange, IN 46761
Ventilation
For the refrigeration process to work
properly, the heat that is generated from
the distillation process and the heat that
is extracted from the interior of the
refrigerator must be dissipated through
convection air ciculation across the
cooling unit coils and condenser on the
rear of the unit.
If the refrigerator will be built into a
cabinet or under a counter, there must be ad-
equate ventilation or the absorption unit on the
back of the refrigerator. The open section available
for incoming and outgoing air must be a minimum
of 30 square inches.
Note: Installation should conform with any appli-
cable building and electrical codes.
Note: The refrigerator must be
removable for future servicing.
The ventilation duct must measure at least 4-1/8”
(105mm) x the width of the refrigerator. Ventilation
grills, if used, must have opening of at least 30
square inches.
Recess Dimensions in (mm) inches:
Model Height Width Depth
RH430LD (526) 20-3/4” (388) 15-1/4” (432) 17”
RH436D (526) 20-3/4” (388) 15-1/4” (432) 17”
RH023LDA (465) 18-3/8” (425) 16-3/4” (410) 16-1/8”
RH023LDAG (465) 18-3/8” (425) 16-3/4” (415) 16-3/8”
RH440LD (558) 22” (405) 16” (466) 18-3/8”
RH447D (558) 22” (405) 16” (466) 18-3/8”
RH441LD (558) 22” (405) 16” (469) 18-1/2”
RH456LD/E (662) 26-1/8” (454) 17-7/8” (523) 20-5/8”
RH460LD (567) 22-3/8” (490) 19-1/4” (494) 19-1/2”
RH461LD (567) 22-3/8” (490) 19-1/4” (494) 19-1/2”
If you have any questions please contact Dometic
at 547-294-8665.
Freestanding Casegoods
In this example, a Credenze is shown with “Right”
ventilation views.
Back View
Exhaust open to
Very top of
space opening
30 in.
2
plus
Intake at
very bottom for drawing
cool air, opening
30 in plus
2
Side View
Good air flow
(20mm) 3/4”
D
.) 1
21
~(20mm)
3/4"
3
(80mm)
2-3/8"
1
2
~(20mm) 3/4”
1
3
A.)
1
2
~(20mm) 3/4”
1
3
A.)
1
3
B.)
1
2
~(20mm)
3/4”
1
3
3
C.) 1
3
~(20mm)
3/4”
11
2
/