APEC ESSENCE R.O. Systems Filter Change Instruction
Changing Stages-1, 2, 3 Pre-Filters: (should be changed at least every 6-12 months)
1) Turn OFF cold water supply to RO system by turning the needle valve stem to the right until it stops. Turn OFF the tank ball
valve by turning the blue handle 90 degrees. Turn on RO faucet lever briefly to relieve the built-up pressure inside the RO
system. This will make opening the housings easier.
2) Open housing: Have the RO standing upright. Slip the plastic wrench onto the #1 housing. Looking down from a top view,
you should open the housing turning clockwise. If necessary, lay RO down on the floor to get a better leverage. If the
housing is too tight, use a hammer and gently tap on the wrench handle to help turn the wrench.
3) Discard 3 used filters, wash housings with mild soap, rinse off. Put 3 new filters into their respective housings: sediment filter
in stage-1, carbon block filters in stages 2 & 3.
4) Close up the housings. Make sure each housing has a black O-ring in the thread groves. Use wrench to tighten each
housing.
5) Remember: Turn ON the cold water supply and OPEN the tank valve after finished changing filters!
6) Check for leaks!
After Taking the housings off, take out the dirty filters and put
the new 3 pre-filters in. Remember, Stage-2 and Stage-3 are
the same carbon filters.
Fig.A
Changing Stage-4 Membrane: (should be changed every 2-3 years)
1) Turn OFF the cold water supply to RO system. Turn OFF the tank ball-valve. Turn on RO faucet lever briefly to relieve the
built-up pressure inside the RO system. This will make opening the housings easier.
2) See Fig. B. Locate the Membrane housing on the system (labeled “Membrane”). Remove the RED or WHITE tubing from
the housing’s cap at point D. For Quick Connect fitting, push IN and hold down on the collet ring square against the
fitting. With the collet held in this position the tube can be removed. For threaded fitting, unscrew the plastic nut (not the
L-shape fitting) and pull out tubing. Open up the cap (turn counter-clockwise). Remove the used membrane. Discard.
Insert the new membrane using a pair of pliers. Push membrane into housing tightly. Avoid touching the Membrane with
your hands to prevent contamination!
3) Important! Make sure the “double-ring” end of the membrane goes into the housing first as shown in Fig. A. above. The
membrane cannot filter water if it’s inserted in the WRONG direction!
4) Close the housing cap. Reconnect the RED or WHITE tubing to the cap. Turn on the cold water supply and open the tank
valve. Let the RO system run to re-fill the tank (takes about 2-3 hours).
5) Check for leaks!
6) Drain the first tanks of water (through faucet) to flush out the new membrane! The 2nd tank of water is ready for use.
Correct direction
Changing Stage-5 or 6 Carbon TCR Filter (should be changed every 3-5 years). The new stage-5 or 6 carbon filter
(FI-ES-TCR-QC) includes a new Tee Fitting on one end. Note: The stage-5 or 6 filter is set up differently for each
model, please follow steps by the model you own.
1) For Model ROES-50 (Stage-5)
Remove the OLD filter: See Fig. B or C. Disconnect the output tubing from point H and tubings at point G & F. To
remove the tubing, Push In and Hold Down on the collet ring square against the fitting. With the collet held in this
position the tube can be removed.
1) For Model ROES-PH75 (Stage-5)
Remove the OLD filter: See Fig. D. Disconnect the output tubing from point H and tubings at point G & F. To
remove the tubing, Push In and Hold Down on the collet ring square against the fitting. With the collet held in this
position the tube can be removed.
1) For Model ROES-UV75 (Stage-6)
Remove the OLD filter: See Fig. E. Disconnect the output tubing from point K and tubing at point H. To remove
the tubing, Push In and Hold Down on the collet ring square against the fitting. With the collet held in this
position the tube can be removed.
2) Unclip the old filter from the membrane housing and discard the used filter.
3) Sanitize: Use some mild bleach solution to rinse the 2 plastic ports of the Tee fitting and the open port of the new filter. This
is to prevent contamination.
NOTE: Only this filter change needs bleach sanitizing. Do Not apply chlorine/ bleach in any way to Membrane for it will
damage the membrane!
Fig. C
Fig. D
C
1
2
43
Fig. E
Fig. B
ROES-50 (Old Model) ROES-50 (New Model)
ROES-PH75 ROES-UV75
To Faucet
To Faucet
To Faucet
Clear Tubing
Clear Tubing
Clear Tubing
Clear Tubing
To Wat e r
Source
To Water
Source
To Wat e r
Source
To Water
Source
To Tank
To Tank
To Tank
To Tank
To Drain
To Drain
To Drain
Membrane Housing
Membrane
Housing
C
1
2
43
D
H
J
K
B
E
F
G
1) Turn OFF cold water supply to RO system. Turn OFF tank ball-valve by turning the blue handle 90 degrees. Turn on RO
faucet briefly to relieve the built-up pressure inside the RO system. This will make removing the tubing easier.
2) Remove the CLEAR outlet tubing at point P See Fig. D. To remove the tubing, Push In and hold down on the collet ring
square against the fitting. With the collet held in this position the tubing can be removed. Once the outlet tubing is discon-
nected, please remove the inlet tubing at point O. Remove old filter and discard.
3) The new PH filter will come with 2 End Plugs. Please remove the plugs before connecting the tubing to the filter.
4) To reconnect the tubing to point O and P , push the tubing into the Quick Connect fitting, then gently pull back on the
tubing to make sure the connection was secure. Make sure “FLOW “ on filter is pointing to the drinking water faucet.
1) Unplug the light Transformer from the power outlet.
2) Do not open the UV light housing.
3) Disconnect the Transformer’s adaptor and UV light’s
adaptor at point M see Fig. F
4) Use a Flat Screwdriver and gently extract the light bulb
on the flat surface at point N.
5) Insert the new light bulb at point N.
6) Make sure the bulb is completely in and secure.
7) Re-connect the 2 adaptors at point M.
8) Power the Transformer.
4) For Model ROES-50 & ROES-PH75 (Stage-5)
Connect New Filter: See Fig. C or D. Attach the new filter onto the clips. Make sure the “FLOW ” arrow on the filter
is pointing towards the pure water output direction. Reconnect the tank yellow tubing and clear tubing from C4 back to
point G & F on the Tee fitting. Then, connect the output tubing to point H.
4) For Model ROES-UV75 (Stage-6)
Connect New Filter: See Fig. E. Attach the new filter onto the clips. Make sure the “FLOW ” arrow on the filter is
pointing towards the pure water output direction. Reconnect the tubings back to point K & H on the new filter.
5) Check for leaks!
Fig. F
For Model ROES-PH75
Changing Stage-6 PH Filter: (should be changed every 6 months).
For Model ROES-UV75
Changing Stage-5 UV Bulb:
(should be changed every 12 months).
Use a Flat Head Screwdriver
M
N
N
©2017 APEC Water Systems. All rights reserved. v.2017.1 www.freedrinkingwater.com
IMPORTANT!
How To Disconnect End Plugs:
Push in and hold down on the collet ring square against the fitting. While holding down the collet ring, pull out the end plug
with your other hand. There are two types of end plugs depending on the model you own. Both types are disconnected the same
way.
NOTE: If end plugs are removed inappropriately, collet rings may come off from QC fittings or elbows.
Make Sure Collet Ring is IN PLACE:
Before inserting tubing, make sure collet ring sits in QC fittings or elbows properly. Leak will occur if collet ring came off or is
missing! Please do not proceed further installation and contact us at: -800-880-4808 if you need further assistance.
2 Types of End Plugs
Soft Plug
for Ultimate
Series
With
Collet Ring
Without
Collet Ring
Hard Plug
for Essence
Series
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

APEC ESSENCE RO Series Operating instructions

Category
Sanitary ware
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI