EnviroLite EVTR24DI42WD Installation guide

Type
Installation guide

EnviroLite EVTR24DI42WD is a LED direct/indirect troffer light with 42 Watts of power, suitable for damp locations and operating in temperatures ranging from -20°C to 45°C. It can be dimmed using a 0-10V dimmer, and it has a power factor of >0.9. The light is suitable for use in both residential and commercial applications, and it is easy to install and maintain. With its sleek design and energy-efficient LED technology, the EnviroLite EVTR24DI42WD is a great choice for any lighting project.

EnviroLite EVTR24DI42WD is a LED direct/indirect troffer light with 42 Watts of power, suitable for damp locations and operating in temperatures ranging from -20°C to 45°C. It can be dimmed using a 0-10V dimmer, and it has a power factor of >0.9. The light is suitable for use in both residential and commercial applications, and it is easy to install and maintain. With its sleek design and energy-efficient LED technology, the EnviroLite EVTR24DI42WD is a great choice for any lighting project.

INSTRUCTION MANUAL
1
LED DIRECT/INDIRECT TROFFER LIGHT
This product has been manufactured with the highest standards of safety and quality.
CHARACTERISTICS:
Electrical System Input Power: 42 W
Input Voltage: 120-277 VAC
Input Frequency: 50/60 Hz
Power Factor: > 0.9
Dimmable: 0 10 V
Temperature Operating Temperature: -20°C to 45°C
TOOLS REQUIRED:
PARTS INCLUDED FOR ASSEMBLY (parts are not to scale):
2
(1) Luminaire
Phillips
Screwdriver
Wire
Cutter
Wire
Stripper
Pliers
Ladder
Safety
Goggles
Electrical
Tape
2 Wire
Nuts
CAUTION:
1. Before starting installation of this fixture or removal of a previous fixture, disconnect
the power by turning off the circuit breaker or by removing the fuse at the fuse box.
2. CONSULT A QUALIFIED ELECTRICIAN IF YOU HAVE ANY ELECTRICAL
QUESTIONS. If you have any non-electrical questions about this fixture, please call
our Customer Service Team at phone# on carton label.
3. KEEP your receipt and these Instructions for Proof of Purchase.
GENERAL:
1. All electrical connections must be in accordance with local, and national electrical
codes.
2. Prior to installation it is important to follow the following guidelines:
A. Turn off the main power at the circuit breaker before installing the fixture, to
prevent possible shock.
B. Be sure that all wires were not damaged during installation and that there are no
rough or sharp edges in contact with the wires.
WARNING:
Min 75°C supply conductors, Type IC, INHERENTLY PROTECTED.
This product must be installed in accordance with the applicable installation code by a
person familiar with the construction and operation of the product and the hazards
involved.
Blinking light of this thermally protected luminaire may indicate overheating.
Vapor barrier must be suitable for 75°C.
Suitable for damp locations.
3
INSTALLATION AND ASSEMBLY:
1. Turn off the power at the circuit breaker box.
2. Remove the fixture from the packaging.
3. Rest the luminaire on the T-Bar of the ceiling
suspension system in the desired location.
(Fig. 1)
4. From above the ceiling, secure the Troffer to
T-Bar by bending built in T-bar clips (#1) on
all four corners of the fixture. (Fig. 2)
5. If local code requires, tie a wire to at least
two of the four T-bar clips (#1) located near
each corner of the Troffer to a structural
member of the ceiling. (Fig. 2)
6. Remove the access plate (#2) and locate the
black fixture wire and the white fixture wire.
(Fig. 3)
7. Remove the access plate located on end of
fixture (#3) and locate the purple fixture wire
and the grey fixture wire. (Fig. 3)
8. Thread the power supply wires through the
knockout hole in the access plate (#2). (Fig.
3)
9. Connect the black supply wire and the white
supply wire to the quick connector. Connect
the supply ground wire to the fixture ground
screw.
10. If the fixture will not be connected to a
dimmer, cap off the purple and grey fixture
wires individually with a wire nut. (Fig. 4)
11. If the fixture will be connected to a dimmer,
thread the dimming wires through the
knockout hole in the access plate (#3) (Fig.
3) and connect the purple and grey fixture
wires to corresponding wires of the wall 0-
10V dimmer. (Fig. 5)
12. Restore power at the circuit breaker box.
4
Fig. 2
Fig. 4
PURPLE FIXTURE WIRE
GREY FIXTURE WIRE
NO DIMMING
Fig. 5
PURPLE FIXTURE WIRE PURPLE DIMMER WIRE
DIMMING CONNECTIONS
GREY FIXTURE WIRE GREY DIMMER WIRE
Fig. 3
Fig. 1
DIMMING:
5
Brand
Series
Model #
Wiring
Load
Capacity (A)
Dimming
Range
Max # of
Luminaires
@ 120V
Max # of
Luminaires
@ 277V
Leviton
Illumatech
IP710-LFZ
3-Way
10
5% - 100%
34
76
Lutron
Diva
DVSTV
3-Way
8
5% - 100%
27
61
Maestro
MS-Z101
3-Way
8
9% - 100%
27
61
Nova T
NTSTV
single
8
7% - 100%
27
61
Philips
Sunrise
Preset
SR500ZTUNV
3-Way
10
5% - 100%
34
76
Luxdrive
NA
A019
NA
NA
4% - 100%
NA
NA
OPERATION:
Turn on power at the circuit breaker or fuse box.
Turn the light switch on to activate the fixture.
CARE AND CLEANING:
NOTE: Do not use any cleaners with chemicals, solvents, or harsh abrasives. Use only a
dry soft cloth to dust or wipe carefully.
Use a dry or slightly dampened clean cloth and wipe the surface of the fixture.
Disconnect power to the fixture by turning off the circuit breaker or by removing the
fuse at the fuse box.
Use a dry or slightly dampened clean cloth to wipe the interior surface of the fixture.
TROUBLESHOOTING:
FCC NOTICE:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiver antenna.
Increase the separation between the equipment and receiver.
Install the product onto on a circuit different from that to which the receiver is
connected.
Consult with the dealer or an experienced radio/TV technician for help.
CAUTION: Any changes made to the electronics circuit will void this equipment’s
compliance with Part 15 of the FCC Rules and should not be operated.
Problem
Solution
The light will not turn on.
Make sure the power supply is on.
Test or replace the switch.
Check the wiring.
Make sure the grey and purple dimming wires
are not touching each other.
The fuse blows or circuit breaker
trips when light is turned on.
Check the wire connections.
6
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

EnviroLite EVTR24DI42WD Installation guide

Type
Installation guide

EnviroLite EVTR24DI42WD is a LED direct/indirect troffer light with 42 Watts of power, suitable for damp locations and operating in temperatures ranging from -20°C to 45°C. It can be dimmed using a 0-10V dimmer, and it has a power factor of >0.9. The light is suitable for use in both residential and commercial applications, and it is easy to install and maintain. With its sleek design and energy-efficient LED technology, the EnviroLite EVTR24DI42WD is a great choice for any lighting project.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI