Barco service bulletin
Serial Number: InfoT 627
Date: 03/11/2005
Product: iCon H600
Priority code*: D
A.
”Must” modification, Barco will provide t he necessary components to per form this mo difica tion
at no charge.
B.
Improves the reliability of the product.
C.
Improves the general working conditions of the product.
D.
For information only.
1. ICON ABORTED STARTUP (LOCKED
PROJECTOR)
Problem description
The projector is locked (LED 1 a
nd LED 3 are lighting up red) : in this case first perform
the download via the debug port to unlock the projector (see procedure b elow ). Thereafter
perform the V1.12 upgrade (see InfoT 628).
The upgrade to V1.12 is r
ecommended for all iCon projectors.
1.1 Debug port download : Only in case of a locked situation (aborted
start up)
RedBoot loader
Loads the projector firmware at startup.
When to perform the
debug po rt download ?
This download via the debug port on the PMP is necessary when the projector is locked with
LED1andLED3onthelocalkeypadred.
To perform the download the HyperTerminal program is used. It can be found under Win-
dows
TM
All programs/accessories/Communications.
The connection between th e projector and the PC is done with a D ata cable with RJ12
connectors.
Barco nv Presentations
Noordlaan 5,
8520 Kuurne
www.barco.com
Page 1 of 9