PREFACE
Preface
The described hard- and software are developments of the KEB Automation KG. The
enclosed documents correspond to conditions valid at printing. Misprint, mistakes and
technical changes reserved.
Signal words and symbols
Certain operations can cause hazards during the installation, operation or thereafter.
There are safety informations in the documentation in front of these operations. Security
signs are located on the device or machine. A warning contains signal words which are
explained in the following table:
DANGER Dangerous situation, which will cause death or serious injury in case of
non-observance of this safety instruction.
WARNING Dangerous situation, which may cause death or serious injury in case of
non-observance of this safety instruction.
CAUTION Dangerous situation, which may cause minor injury in case of non-ob-
servance of this safety instruction.
NOTICE Situation, which can cause damage to property in case of non-obser-
vance.
RESTRICTION
Is used when certain conditions must meet the validity of statements or the result is
limited to a certain validity range.
Is used when the result will be better, more economic or trouble-free by following
these procedures.
More symbols
► Thisarrowstartsanactionstep.
• / - Enumerations are marked with dots or indents.
=> Cross reference to another chapter or another page.
Note to further documentation.
www.keb.de/nc/search
4
PREFACE
Laws and guidelines
KEBAutomationKGconrmswiththeECdeclarationofconformitywiththeCEmark
on the unit name plate, that the device complies with the essential safety requirements.
The EC declaration of conformity can be downloaded on demand via our website. Fur-
therinformationisprovidedinchapter"Certication".
Warranty
The warranty on design, material or workmanship for the acquired device is given in the
current terms and conditions.
Hereyouwillndourcurrenttermsandconditions.
www.keb.de/terms-and-conditions
Furtheragreementsorspecicationsrequireawrittenconrmation.
Support
Through multiple applications not every imaginable case has been taken into ac-
count. If you require further information or if problems occur which are not treated de-
tailed in the documentation, you can request the necessary information via the local
KEB Automation KG agency.
The use of our units in the target products is beyond of our control and therefore
exclusively the responsibility of the machine manufacturer, system integrator or
customer.
Theinformationcontainedinthetechnicaldocumentation,aswellasanyuser-specic
advice in spoken and written and through tests, are made to best of our knowledge and
information about the application. However, they are considered for information only
without responsibility. This also applies to any violation of industrial property rights of a
third-party.
Selection of our units in view of their suitability for the intended use must be done gener-
ally by the user.
Tests can only be done within the application by the machine manufacturer. They
must be repeated, even if only parts of hardware, software or the unit adjustment
are modied.
Copyright
The customer may use the instruction manual as well as further documents or parts from
it for internal purposes. Copyrights are with KEB Automation KG and remain valid in its
entirety.
Other wordmarks or/and logos are trademarks (™) or registered trademarks (®) of their
respectiveownersandarelistedinthefootnoteontherstoccurrence.
5
TABLE OF CONTENTS
Table of Contents
Preface ....................................................................................................................................................3
Signal words and symbols .............................................................................................................3
More symbols .................................................................................................................................3
Laws and guidelines .......................................................................................................................4
Warranty ....................................................................................................................................... 4
Support ....................................................................................................................................... 4
Copyright ........................................................................................................................................4
Table of Contents ................................................................................................................................... 5
List of Figures .........................................................................................................................................8
List of Tables .......................................................................................................................................... 9
Glossary ................................................................................................................................................10
Standards for drive converters / control cabinets .............................................................................12
Product standards that apply directly to the drive converter ........................................................12
Basic standards to which drive converter standards refer directly ............................................... 12
Standards that are used in the environment of the drive converter .............................................13
1 Basic Safety Instructions ............................................ 14
1.1 Target group ...................................................................................................................................14
1.2 Transport, storage and proper use .............................................................................................. 14
1.3 Installation ......................................................................................................................................15
1.4 Electrical connection ....................................................................................................................16
1.4.1 EMC-compatible installation ...............................................................................................17
1.4.2 Voltage test .........................................................................................................................17
1.4.3 Insulation measurement ..................................................................................................... 17
1.5 Start-up and operation .................................................................................................................. 18
1.6 Maintenance ...................................................................................................................................19
1.7 Repair .............................................................................................................................................19
1.8 Disposal ..........................................................................................................................................20
2 Product Description .................................................... 21
2.1 Specied application .....................................................................................................................22
2.1.1 Residual risks ..................................................................................................................... 22
2.2 Unintended use ..............................................................................................................................22
2.3 Part code ........................................................................................................................................23
3 Technical Data .............................................................. 24
3.1 Operating conditions ....................................................................................................................24
3.1.1 Climatic ambient conditions ................................................................................................24
3.1.2 Mechanical ambient conditions ..........................................................................................25
3.1.3 Chemical / mechanical active substances ..................................................................... 25
3.1.4 Electrical operating conditions ............................................................................................26
3.1.4.1 Equipmentclassication ..................................................................................................26
6
TABLE OF CONTENTS
3.1.4.2 Electromagnetic compatibility ..........................................................................................26
4 Unit data ....................................................................... 27
4.1 Accessories ...................................................................................................................................30
4.1.1 AFE,LCLandEMClters ..................................................................................................30
4.1.2 Commonmodelter ........................................................................................................... 31
4.1.3 DC fuses .............................................................................................................................32
4.1.3.1 Alternative DC fuse ..........................................................................................................32
4.1.4 Additional precharging resistor at master-slave operation .................................................33
4.2 Dimensions and weights ..............................................................................................................33
5 Installation .................................................................... 34
5.1 EMC-compatible control cabinet installation .............................................................................. 34
5.2 Installation instructions ................................................................................................................ 34
6 Connection of the COMBIVERT F5-AFE .................... 35
6.1 Description of the input terminals at the drive converter .......................................................... 35
6.2 Terminal blocks of the units .........................................................................................................36
6.3 External fan power supply for housing size P and U ................................................................. 38
6.4 Temperature detection T1, T2 .......................................................................................................39
6.4.1 Use of the temperature input in KTY mode ........................................................................39
6.4.2 Use of the temperature input in PTC mode ........................................................................39
6.5 Input and precharging circuits ..................................................................................................... 40
6.6 Circuit examples ............................................................................................................................41
6.6.1 Instructions to the following circuit example ....................................................................... 41
6.6.2 CircuitexampleforthepowerunitwithAFE/LCLlter .......................................................42
6.6.3 CircuitexampleforthepowerunitwithAFE/LCLlterandcommonmodelter ................ 43
6.6.4 Circuitexampleforthemaster-slaveoperationwithAFE/LCLlterandcommon
modelter .....................................................................................................................44
6.6.5 Circuit example for the control circuit .................................................................................45
6.6.6 Functional description ........................................................................................................46
7 Connection of the Control .......................................... 47
7.1 Control board for F5 AFE units ....................................................................................................47
7.1.1 Assignment of the terminal strip X2A ..................................................................................47
7.1.2 Connection of the control ...................................................................................................48
7.1.3 Digital inputs .......................................................................................................................48
7.1.4 Analog inputs ......................................................................................................................49
7.1.5 Voltage input external power supply ...................................................................................49
7.1.6 Digital outputs .....................................................................................................................49
7.1.7 Relay outputs .....................................................................................................................50
7.1.8 Analog outputs ....................................................................................................................50
7.1.9 Voltage output ....................................................................................................................50
7
TABLE OF CONTENTS
8 Operation of the Control ............................................. 51
8.1 Operation without operator ..........................................................................................................51
8.2 Operation with digital operator ....................................................................................................51
8.2.1 Keyboard operation ............................................................................................................ 52
8.2.1.1 Parameter numbers and / values ....................................................................................52
8.2.1.2 Resetting of error messages ...........................................................................................52
8.2.1.3 Password input ................................................................................................................52
8.3 Interface operator .......................................................................................................................... 53
8.3.1 Description of the diagnostic and parameter interface X6B ...............................................53
8.3.2 Description of the RS232/485 interface X6C ......................................................................54
8.3.3 Connection of the RS232 interface ....................................................................................54
8.3.4 Connection of the RS485 interface ....................................................................................54
8.3.4.1 Wiring RS485 full duplex ................................................................................................. 55
8.3.4.2 Wiring RS485 half duplex ................................................................................................55
8.3.5 Remote control .................................................................................................................. 55
8.3.6 Further operators ................................................................................................................55
9 Dimensioning ............................................................... 56
9.1 Dimensioning Instructions ...........................................................................................................56
9.2 Technical data of KEB COMBIVERT drive converters ...............................................................57
9.3 Technical data of KEB COMBIVERT F5-AFE devices ................................................................59
10 Maintenance ............................................................... 60
10.1 Overload characteristic ...............................................................................................................60
10.2 Maintenance interval ................................................................................................................... 60
10.3 Storage .........................................................................................................................................61
10.3.1 Cooling circuit ...................................................................................................................61
11 Cooling System .......................................................... 62
11.1 Installation of liquid-cooled units ..............................................................................................62
11.1.1 Heat sink and operating pressure .....................................................................................62
11.1.2 Materials in the cooling cicuit ............................................................................................62
11.1.3 Requirements on the coolant ............................................................................................63
11.1.4 Coolant temperature ......................................................................................................... 64
11.1.4.1 Moisture condensation ..................................................................................................64
11.1.4.2 Supply of temper coolant ............................................................................................... 64
11.1.5 Connection to the cooling system .....................................................................................65
11.1.5.1 Fallofpressuredependingontherateofow ..............................................................66
11.1.5.2 Connection scheme for a cooling circuit (series connection) ........................................67
11.1.5.3 Volumeowindependenceoftheheatpowerdissipationandtemperaturedifference 68
11.1.5.4 Connection scheme for a cooling circuit (parallel connection) ......................................69
12 Revision History ........................................................ 70
8
LIST OF FIGURES
List of Figures
Figure 1: External fan power supply for housing size P and U .......................................................38
Figure2: CircuitexampleforthepowerunitwithAFE/LCLlter .....................................................42
Figure3: CircuitexampleforthepowerunitwithAFE/LCLlterandcommonmodelter ............. 43
Figure4: Circuitexampleforthemaster-slaveoperationwithAFE/LCLlterandcommon
modelter ........................................................................................................................44
Figure 5: Circuit example for the control circuit ...............................................................................45
Figure 6: Flow chart switch-on procedure ....................................................................................... 46
Figure 7: Assignment of the terminal strip X2A ............................................................................... 47
Figure 8: Digital inputs ....................................................................................................................48
Figure 9: Analog inputs ...................................................................................................................49
Figure 10: Voltage input external power supply ................................................................................49
Figure 11: Digital outputs ..................................................................................................................49
Figure 12: Relay outputs ................................................................................................................... 50
Figure 13: Analog outputs ................................................................................................................. 50
Figure 14: Voltage output .................................................................................................................. 50
Figure 15: Operation with digital operator ......................................................................................... 51
Figure 16: Password input ................................................................................................................53
Figure 17: Interface operator.............................................................................................................53
Figure 18: Wiring RS485 full duplex..................................................................................................55
Figure 19: Wiring RS485 half duplex ................................................................................................55
Figure 20: Overload characteristic ....................................................................................................60
Figure21: Fallofpressuredependingontherateofow .................................................................66
Figure 22: Coolant connection ..........................................................................................................67
Figure23: Volumeowindependenceoftheheatpowerdissipation ..............................................68
Figure 24: Connection scheme for a cooling circuit ..........................................................................69
9
LIST OF TABLES
List of Tables
Table 1: Part code..........................................................................................................................23
Table 2: Climatic ambient conditions .............................................................................................24
Table 3: Mechanical ambient conditions ........................................................................................25
Table 4: Chemical / mechanical active substances .......................................................................25
Table5: Equipmentclassication ..................................................................................................26
Table 6: Electromagnetic compatibility ..........................................................................................26
Table 7: Unit data...........................................................................................................................27
Table8: AFE,LCLandEMClters ................................................................................................30
Table9: Commonmodelter.........................................................................................................31
Table10: SinusEMCltersandmainschokes ...............................................................................31
Table 11: DC fuses ..........................................................................................................................32
Table 12: Alternative DC fuse .......................................................................................................... 32
Table 13: Dimensions and weights .................................................................................................. 33
Table 14: EMC-compatible control cabinet installation .................................................................... 34
Table 15: Description of the input terminals at the drive converter ..................................................35
Table 16: Description of the RS232/485 interface X6C ...................................................................54
Table 17: Technical data of KEB COMBIVERT drive converters ..................................................... 58
Table 18: Technical data of KEB COMBIVERT F5-AFE devices ..................................................... 59
Table 19: Maintenance interval ........................................................................................................60
Table 20: Heat sink and operating pressure .................................................................................... 62
Table 21: Electro-chemical voltage series / standard potentials against hydrogen .........................63
Table 22: Requirements on the coolant ........................................................................................... 63
Table 23: Coolant inlet temperature is depending on ambient temperature and air humidity .........65
10
GLOSSARY
Glossary
HMI Human machine interface (touch
screen)
HSP5 Fast, serial protocol
HTL Incremental signal with an output
voltage (up to 30V) -> TTL
I²t-monitoring Software function for thermal monito-
ring of the motor winding
IEC International standard
IP xx Degree of protection (xx for level)
KTY Silicium temperature sensor (pola-
rized)
MCM American unit for large wire cross
sections
Modulation Means in drive technology that the
power semiconductors are controlled
MTTF Mean service life to failure
NN Sea level
OC Overcurrent
OH Overheat
OL Overload
OSSD Output signal swithching device; - an
output signal that is checked in regu-
lar intervals on its shutdown. (safety
technology)
PA Potential equalization
PDS Power drive system incl. motor and
measuring probe
PE Protective earth
PELV Protective Extra Low Voltage
PFD Term used in the safety technology
(EN 61508-1...7) for the size of error
probability
PFH Term used in the safety technology
(EN 61508-1...7) for the size of error
probability per hour
PLC Programmable logic controller
Port Part of a network address to the
assignment of TCP and UDP con-
nections
PT100 TemperaturesensorwithR0=100Ω
PT1000 TemperaturesensorwithR0=1000Ω
PTC PTC-resistor for temperature detec-
tion
PWM Pulse width modulation
RJ45 Modular connector with 8 lines
SCL Synchronous sensorless closed loop
SELV Safety Extra Low Voltage (< 60 V)
SFlter Sine-wavelter
0V Earth-potential-free common point
1ph 1-phase mains
3ph 3-phase mains
AC AC current or voltage
AFE Active Front End
AFElter Filter for the AFE device
ASCL Asynchronous sensorless closed
loop
Auto motor
ident.
Automaticallymotoridentication;
calibration of resistance and induc-
tance
AW heat ex-
changer
Air-water heat exchanger
AWG American wire gauge
B2B Business-to-business
BiSS Open source real-time interface for
sensors and actuators (DIN 5008)
CAN Fieldbus system
COMBIVERT KEB drive converters
COMBIVIS KEB start-up and parameterizing
software
DC DC current or voltage
DI Demineralized water, also referred to
as deionized (DI) water
DIN German Institut for standardization
DS 402 CiADS402-CANdeviceprolefor
drives
EMC Electromagnetic compatibility
Emergency
stop
Shutdown of a drive in emergency
case (not de-energized)
Emergency
switching off
Switching off the voltage supply in
emergency case
EN European standard
Encoder emu-
lation
Software-generated encoder output
Endat Bidirectional encoder interface of the
company Heidenhain
EtherCAT Real-time Ethernet bus system of the
company Beckhoff
Ethernet Real-timebussystem-denespro-
tocols, plugs, types of cables
FE Functional earth
FSoE Functional Safety over Ethernet
FU Drive converter
GND Reference potential, ground
GTR7 Braking transistor
HFlter Highfrequencyltertothemains
Hiperface Bidirectional encoder interface of the
company Sick-Stegmann
11
GLOSSARY
SIL The security integrity level is a
measure for quantifying the risk
reduction. Term used in the safety
technology (EN 61508 -1...7).
SS1 Safety function „Safe stop 1“ in ac-
cordance with IEC 61800-5-2
SSI Synchronous serial interface for
encoder
STO Safety function „Safe Torque Off“ in
accordance with IEC 61800-5-2
TTL Incremental signal with an output
voltage up to 5 V
USB Universal serial bus
VARAN Real-time Ethernet bus system
12
STANDARDS FOR DRIVE CONVERTERS / CONTROL CABINETS
Standards for drive converters / control cabinets
Product standards that apply directly to the drive converter
EN 61800-2 Adjustable speed electrical power drive systems - Part 2: General requirements -
Ratingspecicationsforlowvoltageadjustablefrequencya.c.powerdrive
systems (VDE 0160-102, IEC 61800-2)
EN61800-3 Speed-adjustableelectricaldrives.Part3:EMCrequirementsandspecictest
methods (VDE 0160-103, IEC 61800-3)
EN 61800-5-1 Adjustable speed electrical power drive systems - Part 5-1: Safety requirements
- Electrical, thermal and energy (IEC 61800-5-1); German version EN 61800-5-1
EN 61800-5-2 Adjustable speed electrical power drive systems - Part 5-2: Safety Requirements
- Functional (IEC 22G/264/CD)
UL 61800-5-1 American version of the EN 61800-5-1 with „National Deviations“
Basic standards to which drive converter standards refer directly
EN55011 Industrial,scienticandmedicalequipment-Radiofrequencydisturbance
characteristics - Limits and methods of measurement (CISPR 11); German
version EN 55011
EN 55021 Interference to mobile radiocommunications in the presence of impulse noise -
Methods of judging degradation and measures to improve performance (IEC/
CISPR/D/230/FDIS); German version prEN 55021
EN 60529 Degrees of protection provided by enclosures (IP Code) (IEC 60529)
EN 60664-1 Insulation coordination for equipment within low-voltage systems Part 1: Princi-
ples, requirements and tests (IEC 60664-1)
EN60721-3-1 Classicationofenvironmentalconditions-Part3-1:Classicationofgroupsof
environmental parameters and their severities - Section 1: Storage (IEC 60721-
3-1); German version EN 60721-3-1
EN60721-3-2 Classicationofenvironmentalconditions-Part3:Classicationofgroupsof
environmental parameters and their severities - Section 2: Transportation and
handling (IEC 104/670/CD)
EN60721-3-3 Classicationofenvironmentalconditions-Part3:Classicationofgroupsof
environmental parameters and their severities; section 3: Stationary use at
weatherprotected locations; Amendment A2 (IEC 60721-3-3); German version
EN 60721-3-3
EN 61000-2-1 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Descrip-
tion of the environment - Electromagnetic environment for low-frequency
conducted disturbances and signalling in public power supply systems
EN 61000-2-4 Electromagnetic compatibility (EMC) - Part 2-4: Environment; Compatibility
levels in industrial plants for low-frequency conducted disturbances (IEC 61000-
2-4); German version EN 61000-2-4
EN 61000-4-2 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement
techniques - Electrostatic discharge immunity test (IEC 61000-4-2); German
version EN 61000-4-2
EN 61000-4-3 Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement
techniques-Radiated,radio-frequency,electromagneticeldimmunitytest(IEC
61000-4-3); German version EN 61000-4-3
13
STANDARDS FOR DRIVE CONVERTERS / CONTROL CABINETS
EN 61000-4-4 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement
techniques - Electrical fast transient/burst immunity test (IEC 61000-4-4);
German version EN 61000-4-4
EN 61000-4-5 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement
techniques - Surge immunity test (IEC 61000-4-5); German version EN 61000-4-5
EN 61000-4-6 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement
techniques - Immunity to conducted disturbances, induced by radio-frequency
elds(IEC61000-4-6);GermanversionEN61000-4-6
EN 61000-4-34 Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement
techniques - Voltage dips, short interruptions and voltage variations immunity
tests for equipment with mains current more than 16 A per phase (IEC 61000-4-
34); German version EN 61000-4-34
EN 61508-1...7 Functional safety of electrical/electronic/programmable electronic safety-related
systems – Part 1...7 (VDE 0803-1…7, IEC 61508-1…7)
EN 62061 Safety of machinery - functional safety of electrical, electronic and program-
mable electronic safety-related systems (VDE 0113-50, IEC 62061)
EN ISO 13849-1 Safety of machinery - safety-related parts of control systems - Part 1: General
principles for design (ISO 13849-1); German version EN ISO 13849-1
Standards that are used in the environment of the drive converter
DGUV regulation 3 Electrical installations and equipment
DIN 46228-1 Wire-end ferrules; Tube without plastic sleeve
DIN 46228-4 Wire-end ferrules; Tube with plastic sleeve
DIN IEC 60364-5-54 Low-voltage electrical installations - Part 5-54: Selection and erection of
electrical equipment - Earthing arrangements, protective conductors and protec-
tive bonding conductors (IEC 64/1610/CD)
DIN VDE 0100-729 Low-voltage electrical installations - Part 7-729: Requirements for special
installations or locations - Operating or maintenance gangways (IEC 60364-7-
729:2007,modied);GermanimplementationHD60364-7-729:2009
DNVGL-CG-0339 Environmentaltestspecicationforelectrical,electronicandprogrammable
equipment and systems
EN 1037 Safety of machinery - Prevention of unexpected start-up; German version EN 1037
EN 12502-1...5 Protection of metallic materials against corrosion - Part 1...5
EN 60204-1 Safety of machinery - electrical equipment of machines Part 1: General require-
ments (VDE 0113-1, IEC 44/709/CDV)
EN 60439-1 Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and
partially type-tested assemblies (IEC 60439-1); German version EN 60439-1
EN 61373 Railway applications - Rolling stock equipment - Shock and vibration tests (IEC
61373); German version EN 61373
EN 61439-1 Low-voltage switchgear and controlgear assemblies - Part 1: General rules (IEC
121B/40/CDV); German version FprEN 61439-1
VGB R 455 P Water treatment and use of materials in cooling systems
14
GRUNDLEGENDE SICHERHEITSHINWEISE
1 Grundlegende Sicherheitshinweise
Der COMBIVERT ist nach dem Stand der Technik und anerkannten sicherheitstechni-
schen Regeln entwickelt und gebaut. Dennoch können bei der Verwendung funktions-
bedingt Gefahren für Leib und Leben des Benutzers oder Dritter bzw. Schäden an der
Maschine und anderen Sachwerten entstehen.
Die folgenden Sicherheitshinweise sind vom Hersteller für den Bereich der elektrischen
Antriebstechnik erstellt worden. Sie können durch örtliche, länder- oder anwendungs-
spezische Sicherheitsvorschriften ergänzt werden. Sie bieten keinen Anspruch auf
Vollständigkeit. Nichtbeachtung führt zum Verlust von Schadensersatzanspruch.
ACHTUNG Gefahren und Risiken durch Unkenntnis.
Lesen Sie die Gebrauchsanleitung !
Beachten Sie die Sicherheits- und Warnhinweise !
Fragen Sie bei Unklarheiten nach !
1.1 Zielgruppe
Diese Anleitung ist ausschließlich für Elektrofachpersonal bestimmt. Elektrofachperso-
nalimSinnedieserAnleitungmussüberfolgendeQualikationenverfügen:
Kenntnis und Verständnis der Sicherheitshinweise.
Fertigkeiten zur Aufstellung und Montage.
Inbetriebnahme und Betrieb des Produktes.
Verständnis über die Funktion in der eingesetzten Maschine.
Erkennen von Gefahren und Risiken der elektrischen Antriebstechnik.
Kenntnis über DIN IEC 60364-5-54.
Kenntnis über nationale Unfallverhütungsvorschriften (z.B. DGUV regulation 3).
1.2 Transport, Lagerung und sachgemäße Handhabung
Der Transport ist durch entsprechend unterwiesene Personen unter Beachtung der in
dieser Anleitung angegebenen Umweltbedingungen durchzuführen. Die Antriebsstrom-
richter sind vor unzulässiger Beanspruchung zu schützen.
Transport von Antriebsstromrichtern mit einer Kantenlänge >75 cm
Der Transport per Gabelstapler ohne geeignete Hilfsmittel kann zu einer
Durchbiegung des Kühlkörpers führen. Dies führt zur vorzeitigen Alterung bzw.
Zerstörung interner Bauteile.
Antriebsstromrichter auf geeigneten Paletten transportieren.
Antriebsstromrichter nicht stapeln oder mit anderen schweren Gegenstän-
den belasten.
15
GRUNDLEGENDE SICHERHEITSHINWEISE
ESD
Antriebsstromrichter enthalten elektrostatisch gefährdete Bauelemente.
Berührung vermeiden.
ESD-Schutzkleidung tragen.
Lagern Sie Antriebsstromrichter nicht
in der Umgebung von aggressiven und/oder leitfähigen Flüssigkeiten oder Gasen.
mit direkter Sonneneinstrahlung.
außerhalb der angegebenen Umweltbedingungen.
1.3 Einbau und Aufstellung
GEFAHR Nicht in explosionsgefährdeter Umgebung betreiben !
EX
Der COMBIVERT ist nicht für den Einsatz in explosionsgefährdeter
Umgebung vorgesehen.
VORSICHT Bauartbedingte Kanten und hohes Gewicht !
Quetschungen und Prellungen!
Nie unter schwebende Lasten treten.
Sicherheitsschuhe tragen.
Antriebsstromrichter beim Einsatz von Hebewerkzeugen entspre-
chend sichern.
Um Schäden am und im Gerät vorzubeugen:
Darauf achten, dass keine Bauelemente verbogen und/oder Isolationsabstände ver-
ändert werden.
Bei mechanischen Defekten darf das Gerät nicht in Betrieb genommen werden. Die
Einhaltung angewandter Normen ist nicht mehr gewährleistet.
Es darf keine Feuchtigkeit oder Nebel in das Gerät eindringen.
Das Eindringen von Staub ist zu vermeiden. Bei Einbau in ein staubdichtes Gehäu-
se ist auf ausreichende Wärmeabfuhr zu achten.
Einbaulage und Mindestabstände zu umliegenden Elementen beachten. Lüftungs-
öffnungen nicht verdecken.
Antriebsstromrichter entsprechend der angegebenen Schutzart montieren.
Achten Sie darauf, dass bei der Montage und Verdrahtung keine Kleinteile (Bohr-
späne, Schrauben usw.) in den COMBIVERT fallen. Dies gilt auch für mechanische
Komponenten, die während des Betriebes Kleinteile verlieren können.
Geräteanschlüsse auf festen Sitz prüfen, um Übergangswiderstände und Funken-
bildung zu vermeiden.
Antriebsstromrichter nicht begehen.
Die Sicherheitshinweise sind aufzubewahren !
16
GRUNDLEGENDE SICHERHEITSHINWEISE
1.4 Elektrischer Anschluss
GEFAHR Elektrische Spannung an Klemmen und im Gerät !
Lebensgefahr durch Stromschlag !
Niemals am offenen Gerät arbeiten oder offen liegende Teile berüh-
ren.
Bei jeglichen Arbeiten am Gerät Versorgungsspannung abschalten
und gegen Einschalten sichern.
Trotz fehlender Versorgungsspannung kann das Active-Front-End
weiter modulieren, z.B. im generatorischen Betrieb. Die Spannungs-
freiheit ist zu überprüfen.
Warten bis alle Antriebe zum Stillstand gekommen sind, damit keine
generatorische Energie erzeugt werden kann.
Kondensatorentladezeit (5 Minuten) abwarten, ggf. DC-Spannung
an den Klemmen messen.
Sofern Personenschutz gefordert ist, für Antriebsstromrichter geeig-
nete Schutzvorrichtungen einbauen.
Vorgeschaltete Schutzeinrichtungen niemals, auch nicht zu Testzwe-
cken überbrücken.
Schutzleiter immer an Antriebsstromrichter und Motor anschließen.
Zum Betrieb alle erforderlichen Abdeckungen und Schutzvorrichtun-
gen anbringen.
Schaltschrank im Betrieb geschlossen halten.
Für einen störungsfreien und sicheren Betrieb sind folgende Hinweise zu beachten:
Die elektrische Installation ist nach den einschlägigen Vorschriften durchzuführen.
Leitungsquerschnitte und Sicherungen sind entsprechend der angegebenen Mini-
mal-/ Maximalwerte für die Anwendung durch den Anwender zu dimensionieren.
Antriebsstromrichter sind für einen festen Anschluss bestimmt. Querschnitte von
Schutzleitern sind gemäß DIN IEC 60364-5-54 auszulegen.
Stromversorgungssysteme bei denen ein Außenleiter geerdet ist (z.B. Deltanetze)
sind für das Active-Front-End nicht zulässig.
Der Errichter von Anlagen oder Maschinen hat sicherzustellen, dass bei einem vor-
handenen oder neu verdrahteten Stromkreis mit PELV die Forderungen erfüllt bleiben.
Bei Antriebsstromrichtern ohne sichere Trennung vom Versorgungskreis (gemäß
EN 61800-5-1) sind alle Steuerleitungen in weitere Schutzmaßnahmen (z.B. doppelt
isoliert oder abgeschirmt, geerdet und isoliert) einzubeziehen.
Bei Verwendung von Komponenten, die keine potenzialgetrennten Ein-/Ausgänge
verwenden, ist es erforderlich, dass zwischen den zu verbindenden Komponenten
Potenzialgleichheit besteht (z.B. durch Ausgleichsleitung). Bei Missachtung können
die Komponenten durch Ausgleichströme zerstört werden.
Ausschließlich die von KEB angegebenen AFE-/LCL-Filter verwenden.
Bei Anschluss von mehreren Antriebsstromrichtern an das COMBIVERT F5-AFE
sind die maximal zulässigen Zwischenkreiskapazitäten oder die Ladeströme aller
angeschlossenen Antriebsstromrichter, sowie deren Verschaltung zu beachten.
17
GRUNDLEGENDE SICHERHEITSHINWEISE
Wenn beim Errichten von Anlagen Personenschutz gefor-
dert ist, müssen für Antriebsstromrichter geeignete Schutz-
vorrichtungen benutzt werden.
https://www.keb.de/leadmin/media/Manuals/knowledge/04_techinfo/00_
general/ti_rcd_0400_0002_deu.pdf
Anlagen, in die Antriebsstromrichter eingebaut sind, müssen ggf. mit zusätzlichen Über-
wachungs- und Schutzeinrichtungen gemäß den jeweils gültigen Sicherheitsbestim-
mungen, z.B. Gesetz über technische Arbeitsmittel, Unfallverhütungsvorschriften usw.
ausgerüstet werden. Diese Hinweise sind auch bei CE gekennzeichneten Antriebs-
stromrichtern stets zu beachten.
1.4.1 EMV-gerechte Installation
Die Einhaltung der durch die EMV-Gesetzgebung geforderten Grenzwerte liegt in der
Verantwortung des Herstellers der Anlage oder Maschine.
Hinweise zur EMV-gerechten Installation sind hier zu n-
den.
https://www.keb.de/leadmin/media/Manuals/emv/0000ndb0000.pdf
1.4.2 Spannungsprüfung
Eine Prüfung mit AC-Spannung (gemäß EN 60204-1 Kapitel 18.4) darf nicht durchge-
führt werden, da eine Gefährdung für die Leistungshalbleiter im Antriebsstromrichter
besteht.
Auf Grund der Funkentstörkondensatoren wird sich der Prüfgenerator sofort
mit Stromfehler abschalten.
Nach EN 60204-1 ist es zulässig, bereits getestete Komponenten abzuklem-
men. Antriebsstromrichter der KEB Automation KG werden gemäß Produkt-
norm zu 100% spannungsgeprüft ab Werk geliefert.
1.4.3 Isolationsmessung
Eine Isolationsmessung (gemäß EN 60204-1 Kapitel 18.3) mit DC 500 V ist zulässig,
wenn alle Anschlüsse im Leistungsteil (netzgebundenes Potenzial) und alle Steuer-
anschlüsse mit PE gebrückt sind. Bei jedem Gerät ist mit einem Isolationswiderstand
>5MΩzurechnen!
18
GRUNDLEGENDE SICHERHEITSHINWEISE
1.5 Inbetriebnahme und Betrieb
Die Inbetriebnahme (d.h. die Aufnahme des bestimmungsgemäßen Betriebes) ist solan-
ge untersagt, bis festgestellt wurde, dass die Maschine den Bestimmungen der Maschi-
nenrichtlinie entspricht; EN 60204-1 ist zu beachten.
WARNUNG Softwareschutz und Programmierung !
Gefährdung durch ungewolltes Verhalten des Antriebes !
Insbesondere bei Erstinbetriebnahme oder Austausch des Antriebs-
stromrichters prüfen, ob Parametrierung zur Applikation passt.
Die alleinige Absicherung einer Anlage durch Softwareschutzfunktio-
nen ist nicht ausreichend. Unbedingt vom Antriebsstromrichter unab-
hängige Schutzmaßnahmen (z.B. Endschalter) installieren.
Motoren gegen selbsttätigen Anlauf sichern.
VORSICHT Hohe Temperaturen an Kühlkörper und Kühlüssigkeit !
Verbrennung der Haut !
► HeißeOberächenberührungssicherabdecken.
Falls erforderlich, Warnschilder an der Anlage anbringen.
► OberächeundKühlwasserleitungenvorBerührungprüfen.
Vor jeglichen Arbeiten Gerät abkühlen lassen.
Während des Betriebes sind alle Abdeckungen und Türen geschlossen zu halten.
Nur für das Gerät zugelassenes Zubehör verwenden.
Anschlusskontakte, Stromschienen oder Kabelenden nie berühren.
Sofern ein Antriebsstromrichter mit Elektrolytkondensato-
ren im Gleichspannungszwischenkreis (siehe technische
Daten) länger als ein Jahr nicht in Betrieb war, beachten
Sie folgende Hinweise.
www.keb.de/leadmin/media/Manuals/knowledge/04_techinfo/00_gene-
ral/ti_format_capacitors_0400_0001_deu.pdf
19
GRUNDLEGENDE SICHERHEITSHINWEISE
Schalten am Eingang
Bei Applikationen, die zyklisches Aus- und Einschalten des Antriebsstromrichters erfor-
dern, muss nach dem letzten Einschalten eine Zeit von mindestens 5 min vergangen sein.
Werden kürzere Taktzeiten benötigt, setzen Sie sich bitte mit der KEB Automation KG
in Verbindung.
Kurzschlussfestigkeit
Die Antriebsstromrichter sind bedingt kurzschlussfest. Nach dem Zurücksetzen der in-
ternen Schutzeinrichtungen ist die bestimmungsgemäße Funktion gewährleistet.
Ausnahmen:
Treten am Eingang wiederholt Erd- oder Kurzschlüsse auf, kann dies zu einem De-
fekt am Gerät führen.
Der COMBIVERT F5-AFE ist am Netzeingang bei einem Fehler oder im Status
nOP nicht kurzschlussfest! Mit einer Halbleitersicherung ist ein bedingter Schutz am
Netzeingang möglich.
Der Kurzschlussschutz am DC-Ausgang ist durch externe aR bzw. gR-Sicherungen
sicher zu stellen.
1.6 Wartung
Die folgenden Wartungsarbeiten sind nach Bedarf, mindestens jedoch einmal pro Jahr,
durch autorisiertes und eingewiesenes Personal durchzuführen.
Anlage auf lose Schrauben und Stecker überprüfen und ggf. festziehen.
Antriebsstromrichter von Schmutz und Staubablagerungen befreien. Dabei beson-
ders auf Kühlrippen und Schutzgitter von Ventilatoren achten.
► Ab-undZuluftltervomSchaltschranküberprüfenbzw.reinigen.
Funktion der Ventilatoren des Antriebsstromrichters überprüfen. Bei hörbaren Vibra-
tionen oder Quietschen sind die Ventilatoren zu ersetzen.
► BeiüssigkeitsgekühltenAntriebsstromrichternisteineSichtprüfungdesKühlkreis-
laufs auf Dichtigkeit und Korrosion durchzuführen.
1.7 Instandhaltung
Bei Betriebsstörungen, ungewöhnlichen Geräuschen oder Gerüchen informieren Sie
eine dafür zuständige Person !
GEFAHR Unbefugter Austausch, Reparatur und Modikationen !
Unvorhersehbare Fehlfunktionen !
Die Funktion des Antriebsstromrichters ist von seiner Parametrie-
rung abhängig. Niemals ohne Kenntnis der Applikation austauschen.
► ModikationoderInstandsetzungistnurdurchvonder
KEB Automation KG autorisiertem Personal zulässig.
Nur originale Herstellerteile verwenden.
Zuwiderhandlung hebt die Haftung für daraus entstehende Folgen
auf.
20
GRUNDLEGENDE SICHERHEITSHINWEISE
Im Fehlerfall wenden Sie sich an den Maschinenhersteller. Nur dieser kennt die Parame-
trierung des eingesetzten Antriebsstromrichters und kann ein entsprechendes Ersatzge-
rät liefern oder die Instandhaltung veranlassen.
1.8 Entsorgung
Antriebsstromrichter mit Sicherheitsfunktion sind auf eine Nutzungsdauer von 20 Jahren
begrenzt. Danach sind die Geräte zu ersetzen.
Antriebsstromrichter der KEB Automation KG sind professionelle, elektronische Gerä-
te ausschließlich für die gewerbliche Weiterverarbeitung (sog. B2B-Geräte). Die Kenn-
zeichnung erfolgt daher nicht mit dem Symbol der durchgestrichenen Mülltonnen, son-
dern durch die Wortmarke und das Herstellungsdatum.
Im Gegensatz zu überwiegend in privaten Haushalten genutzten Geräten dürfen diese
nicht bei den Sammelstellen der öffentlich rechtlichen Entsorgungsträger abgegeben
werden, sondern müssen nach Nutzungsbeendigung zur Entsorgung gemäß national
geltendem Recht der umweltverträglichen Entsorgung von Elektro- und Elektronikgerä-
ten zugeführt werden.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

KEB COMBIVERT F5 Instructions For Use Manual

Type
Instructions For Use Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI